Biochrom Bio 30+ General Lab Use Amino Acid Analyzer Systems
Vendor: Biochrom
SKU: 80-6000-50
Regular price
0.00 NIS
Sale price
Regular price
Unit price
/per
Quote Required
In stock
A Dedicated Amino Acid Analysis System
| Accurate: | Superb separation, accurately identifies and quantifies free amino acids, as well as the amino acid composition of proteins and peptides. |
| Reliable: | Minimal matrix interference and near baseline separation. Automated derivatization of amino acids maximizes reproducibility. |
| Fast: | Rapid protocols that increase sample throughput by cutting analysis time. |
| Economical: | The column cleaning and repacking service, gives columns an almost indefinite life and cuts the cost of ownership. |
| Fully Automated: | Total PC control allows 24/7 operations. |
| Versatile: | Wide variety of sample types compatible: Protein hydrolysates from various food and feedstuff samples or synthetic drugs, nutraceuticals, beverages. |
| Easy to implement: | No lengthy method development is required as this well characterized system is established worldwide. All customers have their instrument optimized to their application directly from the factory. |
| Convenient: | Interchangeable sample trays allow samples to be prepared in advance and stored refrigerated. |
| Robust: | Advanced fluidics and robust hardware mean easy maintenance for users, backed by the reassurance of Biochrom's dedicated service and support team. |
| Flexible: | Integrated software, choice of different methods to adapt to the user's needs. Automatic sample set-up. Networking and exporting of data. |
| Compact: | Bench top design requiring minimum lab space. |
Screening Methods
Choose from 3 full screening methods according to your business needs:
| Choice of Screening Methods | ||
| System | Use | Minutes (to Arginine) |
| Biochrom Bio 30+ Physiological Accelerated LC System | When speed is a decisive factor, with little compromise on the peak resolution | 120 min |
| Biochrom Bio 30+ Physiological High Performance LC System | The best compromise between speed, resolution and column life | 170 min |
| Biochrom Bio 30+ Physiological High Resolution LC System | When 100% baseline separation and a maximum number of amino acids separated are required. Ideal for research and low sample throughputs | 210 min |
Instrument Typical Package
The instrument package consists of the Analyzer (electronics unit, pumps, and detection system) plus:
- Cooled Autosampler
- Column kit: analytical column and top-up ion exchange resin, prewash column and top-up ion exchange resin
- Ninhydrin
- Buffer Chemical Kit suitable for up to 170 analyses (high performance method)
- Spare parts and consumables kit
- Calibration Standard
- Hardware control and data handling software
- Desktop PC, Windows 10 64-bit Professional, LED widescreen monitor
- User Manual (PDF format)
- Power cables
For buffer and chemicals information, consult the Consumables tab below.
Specifications
- Reproducibility: Area: <0.5% RSD at 10 nanomoles Retention time: <0.1% RSD
- Pumps: Two dual piston pumps with integrated pressure transducer and drain valve Ceramic pump head, sapphire pistons and valves Electronically controlled piston wash
- Operating Pressures: Buffer pressure: maximum 150 bar Ninhydrin pressure: maximum 24 bar
- Analytical Column: High pressure PEEK column packed with Ultropac 8 cation exchange resin Peltier heating/cooling system
- Sample Injection: 3 injection modes (full loop, partial loop and micro), 84 position autosampler Sample volumes from 1 µL to 5000 µL (200 µL loop supplied as standard)
- Temperatures: Column temperature variable between 20°C and 99°C Reaction Coil temperature adjustable between 40°C and 145°C (135°C is optimum)
- Software: Phoenix Integrated Control Software Agilent OpenLAB CDS EZChrom Edition
- Photometer: Single flow cell with optical beam splitter with detection at 440 nm and 570 nm
- Weight and Dimensions: Main System: 50 kg (110 lb.) 48 x 59 x 57 cm (19 x 23 x 22 in.) Autosampler: 21kg (46 lb.) 30 x 57.5 x 36 cm (12 x 23 x 14 in.)
- Required Services: Oxygen free Nitrogen gas (99.99%) or Argon gas regulated to 5 bar Drainage facility 240V/100V, 50Hz/60Hz, 300VA mains supply
- Safety Systems: Automatic shut down and reaction coil flushing in the event of: Power failure Photometer lamp failure Low ninhydrin, low buffer, low coil or low nitrogen pressures High coil or column temperatures, high ninhydrin, high buffer or high coil pressures
Documents
- Bio 30+ Amino Acid Analyzer System brochure
- Biochrom Phoenix Software Brochure
- Material Safety Data Sheet (MSDS)
- Certificates of Analysis
- Ordering Guide
Ordering Information
| Catalogue No. | Configuration | Description |
|---|---|---|
| 80-6000-50 | Physiological Accelerated, Cooled Autosampler | BIO 30+ SYSTEM PHYSIO ACCEL |
| 80-6000-51 | Physiological Accelerated, Autosampler (no cooling) | BIO 30+ PHYSIO ACCELERATED |
| 80-6000-52 | Physiological Accelerated, without Autosampler | BIO 30+ PHYSIO ACCEL W/O A/S |
| 80-6000-53 | Physiological High Performance, Cooled Autosampler | BIO 30+ SYSTEM PHYSIO HP |
| 80-6000-54 | Physiological High Performance, Autosampler (no cooling) | BIO 30+ PHYSIO HIGH PERFORMANC |
| 80-6000-55 | Physiological High Performance, without Autosampler | BIO 30+ PHYSIO W/O A/S HP |
| 80-6000-56 | Physiological High Resolution, Cooled Autosampler | BIO 30+ SYSTEM PHYSIO HR |
| 80-6000-57 | Physiological High Resolution, Autosampler (no cooling) | BIO 30+ PHYSIOLOGICAL HR |
| 80-6000-58 | Physiological High Resolution, without Autosampler | BIO 30+ PHYSIO W/O A/S HR |
| 80-6004-10 | Lithium Accelerated, Cooled Autosampler, Phoenix (no chemicals) | BIO30+ LI ACC COOL A/S PHX NC |
| 80-6004-11 | Lithium High Performance, Cooled Autosampler, Phoenix (no chemicals) | BIO30+ LI HP COOL A/S PHX NC |
| 80-6004-12 | Lithium High Resolution, Cooled Autosampler, Phoenix (no chemicals) | BIO30+ LI HR COOL A/S PHX NC |
Specifications
- Analytical column High pressure PEEK column packed with Ultropac 8 cation exchange resin Peltier heating/cooling system
- Dimensions Main System: 50 kg (110 lb.) 48 x 59 x 57 cm (19 x 23 x 22 in.) Autosampler: 21kg (46 lb.) 30 x 57.5 x 36 cm (12 x 23 x 14 in.)
- Operating pressures Buffer pressure: maximum 150 bar Ninhydrin pressure: maximum 24 bar
- Sample injection 3 injection modes (full loop, partial loop and micro), 84 position autosampler Sample volumes from 1 µL to 5000 µL (200 µL loop supplied as standard)
- Software Phoenix Integrated Control Software Agilent OpenLAB CDS EZChrom Edition
links and documants
- Datasheet url Click here
- Msds url Click here
- Ordering guide url Click here
- Source url Click here
Couldn't load pickup availability
Biochrom Bio 30+ General Lab Use Amino Acid Analyzer Systems
Regular price
0.00 NIS
Sale price
Regular price
Unit price
/per
Quick order list
Free shipping on almost everything
Free Shipping
All orders over $500 are delivered to your doorstep at no extra charge.
30-Days Free Returns
Enjoy the freedom of stress-free shopping with our hassle-free and return policy.
Secure Payment
Shop with confidence knowing your payments are secure and your information