Skip to content
Lentiviral vector

Collection: Viral Vectors & Reporter Systems

Lenti-X and Retro-X vector systems, fluorescent protein plasmids and secreted reporter assays from Takara Bio, held in stock in Israel.

Compare (0/5)

148 products

Ad5-CMV-eGFP TBS7401 - Life Science - TriBioScience

Life Science

Ad5-CMV-eGFP

Regular price 0.00 NIS
Sale price Regular price
Lenti-X™ Concentrator 631231 - Gene function - Takara Bio

Gene function

Lenti-X™ Concentrator

Regular price 1,596.00 NIS
Sale price Regular price
Lenti-X™ GoStix™ Plus 631280 - Gene function - Takara Bio

Gene function

Lenti-X™ GoStix™ Plus

Regular price 3,211.00 NIS
Sale price Regular price
Lenti-X™ qRT-PCR Titration Kit 631235 - Gene function - Takara Bio

Gene function

Lenti-X™ qRT-PCR Titration Kit

Regular price 3,243.00 NIS
Sale price Regular price
Lenti-X™ Concentrator 631232 - Gene function - Takara Bio

Gene function

Lenti-X™ Concentrator

Regular price 5,099.00 NIS
Sale price Regular price
Living Colors® ZsGreen Monoclonal Antibody 632598 - Gene function - Takara Bio

Gene function

Lenti-X™ 293T Cell Line

Regular price 2,643.00 NIS
Sale price Regular price
AAVpro® Purification Kit Maxi (All Serotypes) 6666 - Gene function - Takara Bio

Gene function

AAVpro® Purification Kit Maxi (All Serotypes)

Regular price 3,725.00 NIS
Sale price Regular price
Retro-X™ Concentrator 631455 - Gene function - Takara Bio

Gene function

Retro-X™ Concentrator

Regular price 1,604.00 NIS
Sale price Regular price
Lenti-X™ p24 Rapid Titer Kit 632200 - Gene function - Takara Bio

Gene function

Lenti-X™ p24 Rapid Titer Kit

Regular price 3,745.00 NIS
Sale price Regular price
Lenti-X™ GoStix™ Plus 631281 - Gene function - Takara Bio

Gene function

Lenti-X™ GoStix™ Plus

Regular price 6,541.00 NIS
Sale price Regular price
AAVpro® Titration Kit (for Real Time PCR) Ver.2 6233 - Gene function - Takara Bio

Gene function

AAVpro® Titration Kit (for Real Time PCR) Ver.2

Regular price 2,635.00 NIS
Sale price Regular price
AAVpro® 293T Cell Line 632273 - Gene function - Takara Bio

Gene function

AAVpro® 293T Cell Line

Regular price 2,643.00 NIS
Sale price Regular price
Lenti-X™ p24 Rapid Titer Kit 632200 - Gene function - Takara Bio

Gene function

Lenti-X™ p24 Rapid Titer Kit (Single Wash)

Regular price 3,930.00 NIS
Sale price Regular price
Retro-X™ Concentrator 631456 - Gene function - Takara Bio

Gene function

Retro-X™ Concentrator

Regular price 5,305.00 NIS
Sale price Regular price
AAVpro® Cell & Sup. Purification Kit Maxi (All Serotypes) 6676 - Gene function - Takara Bio

Gene function

AAVpro® Cell & Sup. Purification Kit Maxi (All Serotypes)

Regular price 4,839.00 NIS
Sale price Regular price
placeholder

Gene function

GP2-293 Packaging Cell Line

Regular price 5,080.00 NIS
Sale price Regular price
Adeno-X™ qPCR Titration Kit 632252 - Gene function - Takara Bio

Gene function

Adeno-X™ qPCR Titration Kit

Regular price 3,235.00 NIS
Sale price Regular price
Retro-X™ qRT-PCR Titration Kit 631453 - Gene function - Takara Bio

Gene function

Retro-X™ qRT-PCR Titration Kit

Regular price 3,322.00 NIS
Sale price Regular price
Adeno-X™ GoStix™ 632270 - Gene function - Takara Bio

Gene function

Adeno-X™ GoStix™

Regular price 2,587.00 NIS
Sale price Regular price
placeholder

COVID-19 research

Lenti-X SARS-CoV-2 Packaging Mix (D614G Spike, Truncated)

Regular price 5,269.00 NIS
Sale price Regular price

Frequently asked questions

Lentiviral or retroviral vector — how do I choose?

Gamma-retroviral vectors such as Retro-X integrate only in actively dividing cells, because the pre-integration complex cannot cross an intact nuclear envelope. Lentiviral vectors like Lenti-X integrate in dividing and non-dividing cells, which is why primary neurons, macrophages and quiescent stem cells are handled lentivirally. Where the model divides rapidly and a simpler system is enough, a retroviral vector remains a sound choice.

How do I measure lentiviral titer?

Two routes serve different moments. Lenti-X GoStix Plus is a 10-minute lateral-flow test on 20 µl of supernatant that reads p24 and is quantified through a free smartphone app — useful for checking a packaging run before committing target cells. The Lenti-X qRT-PCR Titration Kit quantifies viral RNA genomes in about four hours and works with all HIV-1-based lentiviral vectors.

What does a fourth-generation packaging system mean in practice?

In the Lenti-X system the packaging and non-viral components are split across a suite of five vectors, premixed at an optimized ratio and transfected into Lenti-X 293T cells. Spreading the genome across more plasmids lowers the chance that recombination regenerates a replication-competent virus, and the premix removes ratio optimization from your bench work. Takara reports an average titer of 1.85 x 10^8 IFU/ml for pLVX vectors packaged this way.

Which fluorescent protein — a marker or a fusion tag?

For fusion constructs choose a true monomer, so the tag does not impose artificial oligomerization: AcGFP1, mCherry and DsRed-Monomer fall in that group. For tracking transduction or transfection efficiency, brightness outweighs oligomeric state, and ZsGreen1 or tdTomato are the usual picks — tdTomato is roughly six times brighter than EGFP and emits at 581 nm, which suits live-animal imaging. Bicistronic pLVX-IRES vectors express your gene and the marker from a single transcript.

Can I run a reporter assay without lysing the cells?

Yes, using secreted reporters. The Ready-To-Glow assay measures secreted Metridia luciferase directly in the culture medium, so one well can be sampled repeatedly across a time course; signal is generally detectable 12–18 hours after transfection and peaks between 48 and 72 hours. The dual version adds secreted alkaline phosphatase (SEAP) as a second reporter or a normalization control.

Who supplies Lenti-X and Retro-X in Israel?

Takara Bio's viral transduction and reporter portfolio is carried for Israeli labs by Danyel Biotech as official Israeli distributor, with cold-chain delivery of packaging mixes and producer cell lines. Viral vector work stays subject to your institution's biosafety rules; talk to us for a quote or for help sizing a packaging run.

Buying Guide

Work backwards from the target cell: non-dividing or primary cells need a Lenti-X lentiviral system, while dividing lines can be served by Retro-X. Then decide how the construct will be read out — a bicistronic pLVX-IRES vector carrying ZsGreen1 or tdTomato when cells must be sorted or imaged, or a secreted Ready-To-Glow reporter when the same culture has to be measured repeatedly without lysis. Budget for the supporting steps as well: Lenti-X 293T cells and a packaging mix for production, a concentrator when titer has to be raised, and GoStix Plus or qRT-PCR titration before transduction.