microOptilab Refractive Index Detector for UHPLC
Vendor: Wyatt Technology
SKU: WOP1U
In stock

Universal Detection for UHPLC and SEC-MALS
Independent of Chromaphores
Independent of chromaphores or fluorophores, differential Refractive Index (dRI) detectors measure concentrations of all types of samples in almost all solvents. The microOptilab brings the universal detection capabilities, unsurpassed concentration range, and superb sensitivity and linearity – familiar from the Optilab™ – to the domain of UHPLC.
Application Note
Download our Application Note on the microOptilab
SEC-MALS with UHPLC
Like standard SEC, UHPLC-SEC analysis relying on column calibration with molecular standards is unreliable when the standards do not accurately reflect your samples in terms of conformation, non-ideal (e.g., hydrophobic) column interactions or reversible association. SEC-MALS employs a microDAWN™ MALS detector downstream of the SEC column and UV detector, to determine molar mass / molecular weight distributions of macromolecules independently of column calibration.
Refractive index detection is an important component of any SEC-MALS system, and necessary for analyzing conjugated proteins or polymers devoid of chromaphores. The microOptilab connects with the microDAWN MALS detector for a complete UHP-SEC-MALS setup that transfers the many benefits of SEC-MALS analysis to the realm of UHPLC.
Key benefits
- Very low band broadening, < 4 µL, to maintain the resolution of very narrow UHPLC peaks
- Extraordinary dRI measurement range, -4.7 x 10-3 to +4.7 x 10-3 RIU (comparable to 25 mg/mL protein in PBS)
- Highly sensitive, ± 1.5 x 10-9 RIU across the entire measurement range
- Measures solvent refractive index, require for MALS calculations
- Measures at the same wavelength as the MALS detector, for maximum accuracy in MALS calculations
- Temperature range 4 °C to 65 °C for proteins and polymers that require a range of temperatures
- High-resolution, touch-screen front panel displays data graphs and instrument diagnostics, even with the host computer turned off
Unparalleled features
Considering the extremely small peak volumes of UHPLC, band broadening in the microOptilab is kept to the absolute minimum, at less than 4 µL, as compared to 20 - 40 µL or more for standard RI detectors. As a result, the superior resolution from UHPLC columns and instruments will not be compromised with the microOptilab RI detector.
Even though the microOptilab offers a dRI measurement range orders of magnitude beyond that of other UHPLC dRI detectors, unlike other detectors there are no range or gain settings in the microOptilab. The full range of instrument detection is always present, and the full sensitivity exists over the entire range. The small flow cell and proprietary temperature regulation enable stable RI baselines and signals which further enhance the detector's sensitivity.
Unlike all other dRI detectors, the microOptilab also measures absolute refractive index in order to determine solvent RI, necessary in light scattering calculations and useful in assessing the accuracy of mixing of solvent gradients.
The microOptilab can be operated below ambient temperatures as easily as above ambient. No hassle temperature control can be programmed down to 4 °C or as high as 65 °C.
The microOptilab is compatible with all UHPLC systems.
Specifications
| Range (RIU) | -0.0047 to +0.0047 |
| Peak-to-peak noise (RIU) | ± 1.5 x 10 |
| Response Time (User Selectable) | 0.04 to 5 seconds |
| Absolute Refractive Index Range (RIU) | 1.2 to 1.8 |
| Sensitivity (RIU) | ± 0.002 |
| Band Broadening | < 4 μL |
| Fill Volume (inlet tubing + flow cell) | 13.7 μL |
| Outlet tubing (0.030" ID) | 228 μL |
| Back pressure created at inlet port (@ 0.5 mL/min H2O, 20 °C) | <320 psi (22 bar) |
| Maximum permissible back pressure allowed at outlet port | 30 psi (2 bar) |
| Control Range | 4 °C to 65 °C |
| Regulation | ± 0.005 °C |
| Light Source | 660 nm |
| Safety Sensors | Vapor and liquid (leak) |
| Digital Output | 25 Hz |
| Analog Output | ± 10 V or ± 1 V output, 18 bits resolution |
| Computer Interface | Ethernet |
| Front Panel Display | 7" (178 mm), high-resolution, multi-touch display for viewing/setting signals, instrument settings and diagnostics |
| Inputs | Analog In (16 bits, ± 10 V A/D), Zero dRI, Purge, Recycle In, Autoinject In, Alarm In |
| Outputs | Autoinject Retransmit, Alarm Out, Recycle Out (to switch Orbit between waste and recycle) |
| Dimensions | 58 cm (L) x 36 cm (W) x 18 cm (H) |
Specifications
- Dimensions 58 cm (L) x 36 cm (W) x 18 cm (H)
- Instrument family microOptilab
- Sensitivity ± 0.002
- Software ASTRA 8 (standard or with Security Pack), with RI Activation Key
- Sub category Refractometers
links and documants
- Source url Click here
Couldn't load pickup availability
microOptilab Refractive Index Detector for UHPLC
Quick order list
Free shipping on almost everything
Free Shipping
All orders over $500 are delivered to your doorstep at no extra charge.
30-Days Free Returns
Enjoy the freedom of stress-free shopping with our hassle-free and return policy.
Secure Payment
Shop with confidence knowing your payments are secure and your information