dRAST Rapid Antimicrobial Susceptibility Testing System
Vendor: QuantaMatrix
SKU: QMdRASTR02
Low stock
dRAST provides MIC-based phenotypic antimicrobial susceptibility testing direct from positive blood culture in as low as 4 hours; reducing time to results by up to 2 days compared to conventional method. The rapid results allow for earlier optimization of antibiotics in critically-ill patients with bloodstream infections and sepsis.
- Dedicated to positive blood culture samples
- Provides phenotypic MIC in as low as 4 hours
- Random access with up to 12 samples simultaneously (15 panel positions)
- Expert system on board with choice of guidelines
- Easy start with no McFarland required, no sample prep
- 2 panels: 1 Gram Neg. + 1 Gram Pos.
- Easy to use, fast to operate
- No daily maintenance
2 days faster than conventional AST
Conventional AST from blood can take at least three days or longer to produce results, as bacteria first has to be detected in blood and a pure isolate obtained before AST can proceed. dRAST, on the other hand, utilizes microfluidic technology and microscopic imaging technology that eliminates the need for pure isolate, to enable much faster results that can impact optimize antibiotic prescribing sooner.

Workflow
Clinical workflow

Technical workflow

Software
User-friendly interface
Simple
- Touchscreen user interface (UI)
- Intuitive result reporting
Lis
- Bi-directional LIS connectivity
- Compatible with all major LIS
Flexible
- Random access and fully automated to improve workflow
- Custom expert rules to accommodate individual lab guidelines
Expert System
- Integration with international and local guidelines (EUCAST, CLSI, and CA-SFM)
- Real-time display of raw data and interpreted results
- Display of MICs and SIR determination in a single screen
- Activated comments and rules for each sample, allowing the clinicians and infectious disease specialists to get all the relevant information
Antibiotic panels
Gram-positive and Gram-negative panels using either CLSI or EUCAST recommended antimicrobials and breakpoints are available for dRAST.
- CLSI panel: 17 Gram-positive , 19 Gram-negative antibiotics with multiple concentrations
- EUCAST panel: 18 Gram-positive , 17 Gram-negative antibiotics with multiple concentrations
Clinical evidence
dRAST provides susceptibility test results with greater reliability at enhanced speed.
Analysis of susceptibility results generated by conventional testing methods took an average of 64.5 hours while results from dRAST direct from positive blood cultures only took 14.3 hours.
Susceptibility result from dRAST is not only rapid but also reliable. Compared to Broth Micro-Dilution (BMD), the overall agreement for dRAST was 94.2% (49/52) and 98.5% (66/67) for patients with gram-positive and gram-negative bacteremia, respectively.
Kim et al., Journal of Medical Microbiology 2018; 67: 325-331
Rapid AST is critical for timely prescribing of optimal, targeted antimicrobials.
A prospective study demonstrated the superior impact of dRAST on the selection of optimal antimicrobial therapy for resistant strains compared to Gram staining or MALDI-TOF MS identification.
The proportion of optimal targeted treatment was similar between the Gram-staining and the MALDI-TOF MS groups. However, there was significant improvement for the dRAST group compared to the MALDI-TOF MS group. The dRAST group demonstrated a 32% higher rate of optimal, targeted antimicrobial therapy compared to MALDI-TOF and the rate of ineffective therapy was 26% lower.
The study demonstrated that result of rapid AST using dRAST contributes significantly more than that of bacterial ID to the administration of optimal targeted antimicrobial treatment.
Kim et al., Journal of Antimicrobial Chemotherapy, Volume 74, Issue 8, August 2019, Pages 2255–2260
Rapid AST by dRAST enables successful implementation of antimicrobial stewardship even in the treatment of bacteremia in the immunosuppressed patients.
Rapid AST by dRAST enables successful implementation of antimicrobial stewardship even for immunosuppressed patients with bacteremia as well as those with underlying hematological disorders.
Deploying dRAST into the diagnostic process allows more timely management of optimal, targeted treatment. In a recent study, time to initiation of optimal, targeted antimicrobials decreased by 14 hours in the dRAST group (39.0 hrs) compared to the conventional AST group (53.2 hrs).
In addition, the proportion of patients receiving optimal, targeted treatment at 48 hours from the first blood draw higher was higher in the dRAST group (66.1%) compared to the conventional AST group (48.3%). Also, the proportion of patients receiving broad-spectrum treatment at 48 hours was lower in the dRAST group (21.4%) compared to the conventional AST group (31.7%).
Kim et al., Clin Microbiol Infect. Volume 27, Issue 1, 2021,Pages 69-75
Specifications
- Assay time As low as 4 hours (MIC results)
- Compatible assays QMAC-dRAST CLSI Gram Negative panelQMAC-dRAST CLSI Gram Positive panelQMAC-dRAST EUCAST Gram Negative panelQMAC-dRAST EUCAST Gram Positive panel
- Format Benchtop automated AST system
- Method MIC-based phenotypic antimicrobial susceptibility testing (CLSI breakpoints)
- Model dRAST
- Regulations CE-IVD; MFDS Korea
- Sample capacity Up to 12 samples simultaneously (15 panel positions), random access
- Software Touchscreen UI; bi-directional LIS connectivity; on-board expert system with EUCAST, CLSI and CA-SFM guidelines
- Specialized sample types Positive blood culture (>300 µL aliquot)
- Technology Microfluidic agarose channel with time-lapse microscopic imaging
links and documants
- Source url Click here
Couldn't load pickup availability
dRAST Rapid Antimicrobial Susceptibility Testing System
Quick order list
Free shipping on almost everything
Free Shipping
All orders over $500 are delivered to your doorstep at no extra charge.
30-Days Free Returns
Enjoy the freedom of stress-free shopping with our hassle-free and return policy.
Secure Payment
Shop with confidence knowing your payments are secure and your information