HYDRAGEL BENCE JONES Urine Immunofixation Gel Kit (Free Light Chains)
Vendor: Sebia
SKU: 4821
In stock
Identification of monoclonal proteins by agarose gel electrophoresis.
Immunofixation is an immunological method for detection and identification of monoclonal proteins in serum and urine. After the separation of serum and urine proteins according to their charge, the gel is incubated with different specific antisera. The gel is then processed in order to remove the antisera excess prior to the final staining step. The gel is interpreted visually to type all immunoglobulins.
Key Benefits
- Good performance: for proteins separation and identification of monoclonal component in serum and urine in agarose gel method.
- Clear band visualisation: in serum and urine for quick identification of suspect monoclonal proteins IgG, IgA, IgM, Kappa (κ) or Lambda (λ) and free light chains involved in gammopathy.
- High quality, ready to use antisera: for optimal reaction performance and accurate monoclonal component identification.
- Complete semi-automated: HYDRASYS 2 SCAN FOCUSING system including sample application, electrophoretic migration, immunofixation, staining, destaining and scanning connected to PHORESIS Software for data & result management.
- Dedicate HYDRAGEL BENCE JONES kits: for detection of very small monoclonal components.
Main Characteristics
Test principle
- The HYDRAGEL IF assay is based on the principle of agarose gel electrophoresis followed by immunofixation.
- After the separation of serum or urine proteins according to their charge, the gel is incubated with different specific antisera for characterization of monoclonal component involved in the gammopathy.
Sample Type
Serum & Urine
Performances
Sensitivity
- The minimal detection limit for monoclonal immunoglobulins is about 120 mg/L for gels stained with acid violet and about 250 mg/L for gels stained with amidoblack.
- According to the mobility of the monoclonal component and polyclonal background, the sensitivity may vary.
Internal sensitivity study demonstrated that a Bence Jones protein can be detected in a serum at a concentration:
- as low as 20 mg/L with anti-free & bound light chains antisera
- as low as 50 mg/L with anti-free light chains antisera
Ordering Information
| Cat. No. | Product | Tests per gel | Mask |
|---|---|---|---|
| 4821 | HYDRAGEL 1 BENCE JONES (MS) | 1 | Standard Mask (SM) |
| 4321 | HYDRAGEL 1 BENCE JONES (M.D) | 1 | Dynamic Mask (DM) |
| 4822 | HYDRAGEL 2 BENCE JONES (MS) | 2 | Standard Mask (SM) |
| 4322 | HYDRAGEL 2 BENCE JONES (M.D) | 2 | Dynamic Mask (DM) |
| 4824 | HYDRAGEL 4 BENCE JONES (MS) | 4 | Standard Mask (SM) |
| 4324 | HYDRAGEL 4 BENCE JONES (M.D) | 4 | Dynamic Mask (DM) |
* SM: Standard Mask ** DM: Dynamic Mask
Specifications
- Applications Multiple Myeloma
- Platform compatibility HYDRASYS 2 SCAN FOCUSING
- Starting material Serum & Urine
- Sub category Multiple Myeloma
- Technology Gel Electrophoresis
links and documants
- Source url Click here
Couldn't load pickup availability
HYDRAGEL BENCE JONES Urine Immunofixation Gel Kit (Free Light Chains)
Quick order list
Free shipping on almost everything
Free Shipping
All orders over $500 are delivered to your doorstep at no extra charge.
30-Days Free Returns
Enjoy the freedom of stress-free shopping with our hassle-free and return policy.
Secure Payment
Shop with confidence knowing your payments are secure and your information

