Extra shelf, stainless steel for H2505-130
Choose your option
ST-180 CO2 Incubator, 180L, with 3 shelves
Choose your option
Extra shelf, stainless steel for H2505-40
Choose your option
Choose your option
Additional Shelf for 180 liter incubators, 1 each
Choose your option
Stacking kit for 45 liter incubator
Choose your option
Additional Shelf for 45 liter incubators, 1 each
Choose your option
Optional CO2 gas regulator (regulates gas pressure from the gas cylinder to the incubator)
Choose your option
MAGic Clamp™ Universal Platform 18 x 18" (for flasks/tubes)
Choose your option
Incu-Shaker 10LR,Refrigerated Shaking Incubator
Choose your option
SureTemp™ Dual Convection Incubators
Choose your option
Extra shelf, stainless steel for H2505-70
Choose your option
MAGic Clamp™ Universal Platform 14 x 12" (for flasks/tubes)
Choose your option
myTemp™ Co2 Mini Digital Incubator, includes 2 stainless steel shelves
Choose your option
Incu-Shaker 10L with flat mat platform, 230V
Choose your option
Incu-Shaker™ 20LR (Refrigerated) with non-slip rubber mat
Choose your option
Extra shelf, 10.5 x 8 in. plastic (not autoclavable)
Choose your option
ST Series & ST Plus CO2 Incubators
Choose your option
INCU-Line® ILCO 180 and ILCO260 Premium CO₂ Incubators
Choose your option
Frequently asked questions
What is the difference between gravity and forced-air (mechanical) convection?
Gravity convection moves air by the natural rise of warm air — quiet, gentle, and kind to delicate or easily dried samples, but less uniform. Forced-air models circulate air with a fan for tighter uniformity and faster recovery after door openings, at the cost of more evaporation. Benchmark's SureTemp incubators are dual-convection, letting you switch modes per protocol.
When do I need a CO2 incubator rather than a standard incubator?
Whenever you culture mammalian cells in bicarbonate-buffered media — the CO2 atmosphere maintains physiological pH, and elevated humidity prevents media evaporation. Bacterial plates usually need only a stable 37 °C air incubator. Benchmark's SureTherm CO2 series covers cell-culture work, including an IncuView option with live-cell imaging inside the chamber.
What is the difference between a laboratory incubator and an oven?
Incubators hold gentle, biological temperatures — typically ambient to roughly 60–80 °C — with tight stability for growing cultures. Ovens run far hotter for drying glassware, curing, and heat treatment, trading fine stability for range. Using an oven to incubate cultures risks overshoot, while drying labware in an incubator simply takes too long.
Do I need an incubator that cools below room temperature?
Yes, if your setpoint is near or below ambient — 25 °C yeast, insect-cell, or enzyme work in a warm Israeli lab needs active cooling, not just heating. Heating-and-cooling models such as the myTemp 65 HC or the refrigerated Incu-Shaker 10LR hold sub-ambient setpoints reliably. Heat-only chambers drift upward when room temperature approaches the setpoint.
Which shaking incubator specs matter for bacterial protein expression?
Capacity (how many flasks of which size fit), speed range under a full flask load, and temperature control — 37 °C growth plus cooling to 16–18 °C if you induce overnight. That cooling requirement points to refrigerated models like the Incu-Shaker 10LR rather than heat-only units. Also confirm the platform accepts your clamp sizes.
Who supplies laboratory incubators and ovens in Israel?
Benchmark Scientific's incubator and oven range — myTemp, SureTemp, SureTherm CO2, and Incu-Shaker lines — reaches Israeli labs through Danyel Biotech, the official local distributor. Local stock, installation guidance, and application support are included; start with a quote request from this page.