Skip to content
Acrodisc syringe filters

Collection: Lab Filtration

Whatman syringe filters and glass microfiber grades to Cytiva ULTA bioprocess capsules — lab filtration with local stock in Israel.

Compare (0/5)

311 products

Whatman™ Membrane-Butler 10477100 - Lab filtration products - Cytiva

Lab filtration products

Whatman™ Membrane-Butler

Regular price 9,996.00 NIS
Sale price Regular price
Bottle/Vial Filter 18102985 - Uncategorized - Cytiva

Uncategorized

Bottle/Vial Filter

Regular price 0.00 NIS
Sale price Regular price
Biacore™ T200 GoldSeal 29003121 - Uncategorized - Cytiva

Uncategorized

Adapter filter unit

Regular price 0.00 NIS
Sale price Regular price
Biacore™ T200 GoldSeal 29003121 - Uncategorized - Cytiva

Uncategorized

Bottom filter unit

Regular price 0.00 NIS
Sale price Regular price
Whatman™ Immunopore Membranes 78316407 - Protein analysis equipment and supplies - Cytiva

Protein analysis equipment and supplies

Whatman Immunopore Membranes

Regular price 0.00 NIS
Sale price Regular price
placeholder

Molecular and Immunodiagnostics

Prima 40

Regular price 0.00 NIS
Sale price Regular price
FFHP Plus Membranes 10547125 - Molecular and Immunodiagnostics - Cytiva

Molecular and Immunodiagnostics

FFHP Plus Membranes

Regular price 0.00 NIS
Sale price Regular price
VF2 glass fiber 8124-1750 - Molecular and Immunodiagnostics - Cytiva

Molecular and Immunodiagnostics

VF2 glass fiber

Regular price 784.00 NIS
Sale price Regular price
Whatman™ LF1 8121-1750 - Molecular and Immunodiagnostics - Cytiva

Molecular and Immunodiagnostics

Whatman LF1

Regular price 871.00 NIS
Sale price Regular price
Rapid 24 and Rapid 27 8131-2250 - Molecular and Immunodiagnostics - Cytiva

Molecular and Immunodiagnostics

Rapid 24 and Rapid 27

Regular price 0.00 NIS
Sale price Regular price
CLEARLine® Single-Use Vacuum Filtration Systems, PES 0.22 µm (CL500)

CLEARLine®

CLEARLine® Single-Use Vacuum Filtration Systems, PES 0.22 µm

Regular price 0.00 NIS
Sale price Regular price

Frequently asked questions

Should I use a 0.2 µm or 0.45 µm filter?

Use 0.45 µm for particulate removal — clarifying samples, mobile phases, and buffers where sterility is not required. Use 0.2/0.22 µm when you need to remove bacteria: cell culture media, protein solutions, and anything that must stay sterile. Sterilizing-grade filters are validated by retaining Brevundimonas diminuta, a bacterium small enough to pass a 0.45 µm membrane.

How do I choose a syringe filter membrane?

Match the membrane to the sample. Whatman Puradisc filters come in regenerated cellulose, cellulose acetate, cellulose nitrate, nylon, PTFE, PES, and PVDF: PES and PVDF offer low protein binding for biological samples, hydrophobic PTFE suits aggressive organic solvents, nylon is a general-purpose choice for mixed aqueous-organic samples, and regenerated cellulose covers both solvent types with low binding. Then pick the diameter for your volume — Puradisc handles routine samples up to 100 mL.

What are Whatman glass microfiber grades like GF/A, GF/C, and GF/F used for?

These binder-free depth filters capture fine particles at high flow rates and tolerate organic solvents and most acids. Grade GF/A (1.6 µm nominal retention) is the workhorse for water and air monitoring; GF/C is the standard for total suspended solids testing; GF/F combines fine retention with very high loading capacity. Note they retain nominally, by depth — for absolute retention you need a membrane.

Are Whatman filters still made — who owns Whatman now?

Whatman is the lab filtration brand of Cytiva, and the papers, glass microfiber grades, and Puradisc syringe filters continue under the Whatman name. In Israel the range is carried by Danyel Biotech alongside the rest of the Cytiva portfolio.

What are ULTA capsule filters used for in bioprocessing?

Cytiva's ULTA single-use capsules cover normal-flow filtration from prefiltration and clarification through bioburden reduction to sterile filtration of buffers, media, and bioreactor harvest. ULTA Pure SG is the sterilizing-grade PES option, available gamma-sterilized in ReadyToProcess formats from 2 to 30 inches, and capsules can terminate in ReadyMate aseptic connectors for single-use flow paths.

Who supplies Whatman and Cytiva filtration products in Israel?

From Puradisc syringe filters to ULTA process capsules, the Cytiva filtration portfolio is stocked locally by Danyel Biotech, its official Israeli distributor — with technical help matching membranes to samples. A quote is one click away on this page.

Buying Guide

Decide by goal, then format: 0.45 µm for clarification, 0.2 µm sterilizing-grade for sterility; low-protein-binding PES or PVDF for biologicals, PTFE for harsh solvents, glass microfiber for high-load prefiltration. Syringe filters such as Whatman Puradisc suit volumes up to about 100 mL, while process volumes move to ULTA single-use capsules — sized 2 to 30 inches, with gamma-sterilized options for aseptic workflows.