{"product_id":"zhichu-high-temperature-and-humidity-test-chamber-hcp-90-150-260","title":"High Temperature and Humidity Test Chamber HCP-90 \/ 150 \/ 260","description":"\u003cp\u003eHigh temperature and humidity heating incubator HCP-90\/150\/260 provides precise temperature and humidity control for optimal sample incubation. Ideal for cell culture, microbial research, and laboratory experiments, its robust design ensures stability, reliability, and consistent performance in medical, pharmaceutical, and research applications.\u003c\/p\u003e\u003cp\u003e1. Temperature Control\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eSix-Side Heating System: Delivers even, rapid heating with fast temperature recovery, ensuring stable environmental conditions.\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eWhy It Matters: Provides consistent, uniform temperature control, ideal for microbial cultures, stability testing, or material studies requiring high temperatures.\u003c\/p\u003e\u003cp\u003e2. Humidity Control\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eProgrammable Temperature \u0026amp; Humidity Control: Features a chamber humidifier for rapid, efficient humidification, enabling precise environmental adjustments.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eNew generation of high temperature resistant humidity sensor: Advanced sensor ensures accurate humidity measurement in high-temperature conditions, enhancing reliability in humid environments.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eWhy It Matters: Maintains precise, stable humidity levels, critical for experiments requiring high humidity, such as fungal growth or material durability tests.\u003c\/p\u003e\u003cp\u003e3. Airflow and Environmental Uniformity\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003eHorizontal Dual Circulation Air Duct Design: Non-natural convection minimizes evaporation and ensures uniform temperature and humidity distribution throughout the chamber.\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eWhy It Matters: Promotes consistent conditions, supporting reliable experimental outcomes and uniform sample growth.\u003c\/p\u003e\u003cp\u003e4. Safety and Reliability\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eComprehensive Safety Features: Includes over-temperature alarm, automatic shutdown during over-temperature conditions, and power failure recovery with automatic restart.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eInterference Minimization: Filter ring reduces external noise and electromagnetic interference, enhancing operational stability.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eWhy It Matters: Protects samples, ensures safe operation, and supports uninterrupted experiments, vital for long-term high-temperature and high-humidity studies.\u003c\/p\u003e\u003cp\u003e5. Data Management\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eData Recording and Analysis: Stores up to 150,000 data points for temperature and humidity with configurable intervals; displays curves with USB export for analysis.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eExternal Cloud Platform Interface (Optional): Reserved for cloud connectivity, enabling remote monitoring and data management.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eWith increasing demand for intelligent laboratory equipment, this incubator model supports traceable data storage and convenient export functions, helping users improve experiment documentation and process control.\u003c\/p\u003e\u003cp\u003eWhy It Matters: Enables robust data tracking, analysis, and remote access, supporting research documentation and compliance.\u003c\/p\u003e\u003cp\u003e6. User Interface and Control\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cp\u003e4.3-Inch LED Smart Touch Screen: Displays temperature (0.1°C accuracy) and humidity with intuitive controls; integrated alarm system triggers visual\/audible alerts (e.g., door open time, sensor issues).\u003c\/p\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eWhy It Matters: Simplifies operation with precise monitoring and alerts, enhancing control and safety.\u003c\/p\u003e\u003cp\u003e7. Design and Accessibility\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003eStackable Design: Supports two-layer stacking with optional accessories, maximizing lab space.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eMagnetic Door Design: Ensures gas-tight sealing with rapid, convenient opening.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRemovable Shelf Design: Flexible, pull-out shelves reduce bacterial dead zones, detachable without tools for easy cleaning.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eFuma Casters (Optional): Flexible casters enable easy repositioning and secure locking, with accessible under-equipment cleaning.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eWhy It Matters: Enhances usability, hygiene, and space efficiency with a scalable, gas-tight, and mobile design tailored for laboratory needs.\u003c\/p\u003e\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eHCP-90\u003c\/td\u003e\n\u003ctd\u003eHCP-150\u003c\/td\u003e\n\u003ctd\u003eHCP-260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume of box\u003c\/td\u003e\n\u003ctd\u003e106L\u003c\/td\u003e\n\u003ctd\u003e175L\u003c\/td\u003e\n\u003ctd\u003e300L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of partition plates\u003c\/td\u003e\n\u003ctd\u003e3 plates (standard)\u003c\/td\u003e\n\u003ctd\u003e3 plates (standard)\u003c\/td\u003e\n\u003ctd\u003eStandard configured 4 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003eAC220V\/50HZ\u003c\/td\u003e\n\u003ctd\u003eAC220V\/50HZ\u003c\/td\u003e\n\u003ctd\u003eAC220V\/50HZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput power\u003c\/td\u003e\n\u003ctd\u003e1300W\u003c\/td\u003e\n\u003ctd\u003e1300W\u003c\/td\u003e\n\u003ctd\u003e1300W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating ambient temperature\u003c\/td\u003e\n\u003ctd\u003e19℃-25℃\u003c\/td\u003e\n\u003ctd\u003e19℃-25℃\u003c\/td\u003e\n\u003ctd\u003e19℃-25℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay screen\u003c\/td\u003e\n\u003ctd\u003e4.3-inch color touch screen\u003c\/td\u003e\n\u003ctd\u003e4.3-inch color touch screen\u003c\/td\u003e\n\u003ctd\u003e4.3-inch color touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature control range\u003c\/td\u003e\n\u003ctd\u003eRoom temperature+5℃-160℃(at RT25℃)\u003c\/td\u003e\n\u003ctd\u003eRoom temperature+5℃-160℃(at RT25℃)\u003c\/td\u003e\n\u003ctd\u003eRoom temperature+5℃-160℃(at RT25℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature display accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1(37℃)\u003c\/td\u003e\n\u003ctd\u003e±0.1(37℃)\u003c\/td\u003e\n\u003ctd\u003e±0.1(37℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature resolution\u003c\/td\u003e\n\u003ctd\u003e0.1℃\u003c\/td\u003e\n\u003ctd\u003e0.1℃\u003c\/td\u003e\n\u003ctd\u003e0.1℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature uniformity\u003c\/td\u003e\n\u003ctd\u003e±0.3(37℃,at RT 25℃)\u003c\/td\u003e\n\u003ctd\u003e±0.3(37℃,at RT 25℃)\u003c\/td\u003e\n\u003ctd\u003e±0.3(37℃,at RT 25℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature control mode\u003c\/td\u003e\n\u003ctd\u003ePID microcomputer control\u003c\/td\u003e\n\u003ctd\u003ePID microcomputer control\u003c\/td\u003e\n\u003ctd\u003ePID microcomputer control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity control accuracy\u003c\/td\u003e\n\u003ctd\u003e≤±3%(at 37℃)\u003c\/td\u003e\n\u003ctd\u003e≤±3%(at 37℃)\u003c\/td\u003e\n\u003ctd\u003e≤±3%(at 37℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity control range\u003c\/td\u003e\n\u003ctd\u003eAmbient humidity -98%RH(at a temperature of 70℃)without humidity control in the above situations\u003c\/td\u003e\n\u003ctd\u003eAmbient humidity -98%RH(at a temperature of 70℃)without humidity control in the above situations\u003c\/td\u003e\n\u003ctd\u003eAmbient humidity -98%RH(at a temperature of 70℃)without humidity control in the above situations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity resolution\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume of water storage tank\u003c\/td\u003e\n\u003ctd\u003e1L\u003c\/td\u003e\n\u003ctd\u003e1L\u003c\/td\u003e\n\u003ctd\u003e1L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidification method\u003c\/td\u003e\n\u003ctd\u003eProgrammable temperature \u0026amp; humidity chamber humidifier\u003c\/td\u003e\n\u003ctd\u003eProgrammable temperature \u0026amp; humidity chamber humidifier\u003c\/td\u003e\n\u003ctd\u003eProgrammable temperature \u0026amp; humidity chamber humidifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCavity material\u003c\/td\u003e\n\u003ctd\u003e304 antibacterial stainless steel\u003c\/td\u003e\n\u003ctd\u003e304 antibacterial stainless steel\u003c\/td\u003e\n\u003ctd\u003e304 antibacterial stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension of inner cavity\u003c\/td\u003e\n\u003ctd\u003eD450×W450×H550mm\u003c\/td\u003e\n\u003ctd\u003eD560×W540×H580mm\u003c\/td\u003e\n\u003ctd\u003eD560×W600×H900mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal dimensions\u003c\/td\u003e\n\u003ctd\u003eD630×W590×H890mm\u003c\/td\u003e\n\u003ctd\u003eD715×W680×H900mm\u003c\/td\u003e\n\u003ctd\u003eD715×W730×H1220mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eModels\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eChamber volume\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHCP-90\u003c\/td\u003e\n\u003ctd\u003e106L\u003c\/td\u003e\n\u003ctd\u003eHigh temperature and humidity test chamber RT+5-160C, RH-98%, 106L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHCP-150\u003c\/td\u003e\n\u003ctd\u003e175L\u003c\/td\u003e\n\u003ctd\u003eHigh temperature and humidity test chamber RT+5-160C, RH-98%, 175L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHCP-260\u003c\/td\u003e\n\u003ctd\u003e300L\u003c\/td\u003e\n\u003ctd\u003eHigh temperature and humidity test chamber RT+5-160C, RH-98%, 300L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Zhichu","offers":[{"title":"106L","offer_id":68035644031055,"sku":"HCP-90","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"175L","offer_id":68035644063823,"sku":"HCP-150","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"300L","offer_id":68035644096591,"sku":"HCP-260","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/heating-incubator.webp?v=1793870872","url":"https:\/\/www.danyel.co.il\/products\/zhichu-high-temperature-and-humidity-test-chamber-hcp-90-150-260","provider":"danyel biotech","version":"1.0","type":"link"}