{"product_id":"r230-focused-ultrasonicator-500620","title":"R230 Focused-ultrasonicator","description":"\u003cp\u003e\u003cstrong\u003eAdd greater robustness and reproducibility to your sample prep with the R230 Focused-Ultrasonicator.\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eThe R230 harnesses the power of Adaptive Focused Acoustics® (AFA®) technology to enable fast and reliable sample preparation for genomics, proteomics, and beyond. It works with a wide range of sample types and can be integrated directly on the deck of many automated liquid handlers.\u003c\/p\u003e \u003cp\u003eIt’s scalable, flexible—and exactly what you need to simplify your workflows.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e \u003cul\u003e \u003cli\u003ePowered by Adaptive Focused Acoustics® (AFA®)\u003c\/li\u003e \u003cli\u003eOn-deck or on-bench\u003c\/li\u003e \u003cli\u003eThermally controlled\u003c\/li\u003e \u003cli\u003eAutomation compatible with integrated RFID\u003c\/li\u003e \u003cli\u003eAutomated water management\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eBenefits\u003c\/p\u003e \u003cul\u003e \u003cli\u003eControlled, non-contact processing\u003c\/li\u003e \u003cli\u003eCompatible with most liquid handlers\u003c\/li\u003e \u003cli\u003eMaintains optimal sample integrity\u003c\/li\u003e \u003cli\u003eReduced human error\u003c\/li\u003e \u003cli\u003eUser-defined scheduling for system set-up maximizes laboratory efficiency\u003c\/li\u003e \u003cli\u003eHigher recovery\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePrimary Applications\u003c\/th\u003e\n\u003ctd\u003eBead mixing\/pellet resuspension, Compound screening, DNA shearing, DNA\/RNA\/Total NA\/Protein Extraction from FFPE, Hit validation, Low mass sample extraction: FFPE, tissue, and whole blood, Mammalian cell lysis, Target ID \u0026amp; validation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTreatment Power\u003c\/th\u003e\n\u003ctd\u003e.5–110 W Avg. Incident Power\/1.5–450 W PIP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Requirements\u003c\/th\u003e\n\u003ctd\u003e100 to 240 VAC 500VA, 50 to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Environment\u003c\/th\u003e\n\u003ctd\u003eAmbient Environment: 15°C to 30°C (59°F to 86°F), Up to 80%, non-condensing, up to 3000M, pollution degree II, Overvoltage Category 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e5 °C to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eComplies with Low Voltage Directive 2006\/95\/EC. Certified to IEC\/EN\/UL 61010-1:2004 “Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use, Part1: General Requ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRegulatory Labeling\u003c\/th\u003e\n\u003ctd\u003eCE, ETL Mark (for Product Safety), WEEE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSonoLab Version\u003c\/th\u003e\n\u003ctd\u003eSonoLab 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating System\u003c\/th\u003e\n\u003ctd\u003eMicrosoft Windows 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWCS\u003c\/th\u003e\n\u003ctd\u003eWCS 3.0 included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChiller\u003c\/th\u003e\n\u003ctd\u003eWCS 3.0 (Chiller and WCS in one unit- included with system purchase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNGS Sample Volumes\u003c\/th\u003e\n\u003ctd\u003e5 to 50 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCovaris Consumables\u003c\/th\u003e\n\u003ctd\u003e8 AFA-TUBE TPX Strip, 8 AFA-TUBE TPX 150 Strip, 8 microTUBE Strip, 96 AFA-TUBE TPX Plate, 96 AFA-TUBE TPX 150 Plate, 96 AFA-TUBE PS Plate, 96 microTUBE Plate, 384 AFA-TUBE PP Plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e500620\u003c\/td\u003e\n\u003ctd\u003eR230 Focused-ultrasonicator\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.covaris.com\/wp-content\/uploads\/resources_pdf\/M020184_R230-Protein-Flyer-Web.pdf\" target=\"_blank\"\u003eCovaris R230 Focused-ultrasonicator for Protein Extraction, Purification, and Digestion\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.covaris.com\/wp-content\/uploads\/2026\/10\/pn_010480_.pdf\" target=\"_blank\"\u003eR230 Focused-ultrasonicator Setup \u0026amp; Instruction Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Covaris","offers":[{"title":"Default Title","offer_id":68354903572559,"sku":"500620","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/covaris-500620_7.jpg?v=1795696390","url":"https:\/\/www.danyel.co.il\/products\/r230-focused-ultrasonicator-500620","provider":"danyel biotech","version":"1.0","type":"link"}