{"product_id":"quadcount-automated-cell-counter-e7500-e","title":"QuadCount Automated Cell Counter","description":"With count speeds at fast as 20 seconds per sample, the Accuris QuadCount provides many advantages over the tedious and time consuming manual hemocytometry method.  The advanced software eliminates human bias in dead\/live determinations, reduces counting errors, saves time, and improves efficiency.\n\nThe QuadCount utilizes a unique 4-chambered disposable QuadSlide™.  Four samples can be processed in one slide (twice the capacity of standard 2-chambered slides), decreasing consumable costs.  Each chamber has a hydrophilic inner surface with an engraved grid pattern.  High precision production and molding ensure that each QuadSlide meets the rigorous standards and dimensional tolerances required for optimal counting performance.\n\n\n\n3 Count Modes Available to analyze different sample volumes.\n\nQuick Mode: 0.15uL \/ 20 seconds (1 image frame)\n\nNormal Mode: 0.9 uL \/ 30 seconds (6 image frames)\n\nPrecise Mode: 3.6 uL\/ 100 seconds  (24 image frames)\n\nThe QuadCount’s ability to analyze larger sample volumes\/multiple images provides significantly better accuracy.\n\nAdvanced Optics and Imaging Technology\n\nThe Accuris QuadCount incorporates the highest quality optical and electronic components, such as a 4X objective lens and 5MP CMOS detector, to ensure reliable performance and consistent results.\n\nThe precision motorized stage adjusts the position of the lens and sensor assembly in micron increments for automatic focus.  Multiple image frames (up to 24) can be captured to increase the volume of sample counted, providing a higher level of accuracy.\n\nAutofocus\n\nCorrect focus is crucial for accurate counts of viable cells.  The QuadCount’s proprietary autofocus system and image analysis software work in conjunction with the motorized stage to analyze and capture images in the proper focal plane.\n\nAdvanced Algorithms\n\nAdvanced detection algorithms easily manage irregularly shaped and aggregated cells.  Often misinterpreted by visual counting, correct analysis of these cells is performed by QuadCount’s software, resulting in more accurate counts.  User to user variation is eliminated.\n\nIntuitive User Interface\n\nAfter images are captures, the cell count parameters are easily adjusted.\n\nGating size range\nAggregation level\nLive\/dead definition\nCell population statistics are viewed as a histogram and cell size gating can be adjusted.  Choose to view the histogram data for individual or multiple chambers in each QuadSlide.\n\nUSB ports are available for connecting  a printer,  external keyboard, or flash drive.  Detailed PDF reports can be exported to a flash drive and transferred to a PC for saving or printing .\n\nSample QuadCount Report from Dartmouth Medical Labs\n\nCompatibility report for 16 mammalian cell lines (HeLa, Jurkat T, HCT116, etc)\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eOptics\u003c\/th\u003e\n\u003ctd\u003eHigh quality 4x objective lens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePixel Resolution\u003c\/th\u003e\n\u003ctd\u003e2592 x 1944\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eImage Detection\u003c\/th\u003e\n\u003ctd\u003e5 mega pixel CMOS sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIllumination\u003c\/th\u003e\n\u003ctd\u003eGreen LED (50,000 hour life)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Volume\u003c\/th\u003e\n\u003ctd\u003e20ul (4 samples per QuadSlide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Counting Volume\u003c\/th\u003e\n\u003ctd\u003e3.6ul (24 image captures)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConsumable Slide\u003c\/th\u003e\n\u003ctd\u003eQuadSlide, 4-chamber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCounting Modes\/Speeds\u003c\/th\u003e\n\u003ctd\u003eQuick (20 sec), Normal (30 sec), Precise (100 sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDynamic Range\u003c\/th\u003e\n\u003ctd\u003e1 x 104 to 1 x 107 cells per ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCell Size Range\u003c\/th\u003e\n\u003ctd\u003e5 to 60 um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData Output\u003c\/th\u003e\n\u003ctd\u003eUSB drive for PDF report\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e6.4 x 11.5 x 8.5 inches \/ 16.3 x 29.3 x 21.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e11 Lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical\u003c\/th\u003e\n\u003ctd\u003e115V or 230V, 50-60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2021\/03\/E7500-Accuris-QuadCount.pdf\"\u003eBrochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2021\/03\/E7500-QuadCount-User-Manual-1.2-3-3-2020.pdf\"\u003eManual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Benchmark Scientific","offers":[{"title":"Default Title","offer_id":45980599156815,"sku":"E7500-E","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/E7400-QC7.jpg?v=1782721807","url":"https:\/\/www.danyel.co.il\/products\/quadcount-automated-cell-counter-e7500-e","provider":"danyel biotech","version":"1.0","type":"link"}