{"product_id":"qiagen-qiastat-dx-rise-high-throughput-syndromic-testing-system-9003163","title":"QIAstat-Dx Rise High-Throughput Syndromic Testing System","description":"\u003cp\u003eQIAstat-Dx simplifies infectious disease diagnostics so you can get faster results for your patients. All you need are a patient sample, a QIAstat-Dx assay cartridge and one of our intuitive QIAstat-Dx instruments. \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eQIAstat-Dx Rise is our higher-throughput powerhouse, built to fit the needs of high-demand institutions. Combined with QIAstat-Dx assay cartridges, QIAstat-Dx Rise uses multiplex PCR technology – also known as syndromic testing – to quickly survey many different pathogens in a single patient sample. The cartridges come ready with all reagents preloaded and use our trusted assay chemistry. The system includes random access and batch testing options, with a daily capacity of 160 samples using 8 Analytical Modules. The QIAstat-Dx Rise also includes a multi-test front drawer that can accommodate up to 18 cartridges at the same time, and a waste drawer to automatically collect used cartridges.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eEach instrument is made up of two components: 1) A QIAstat-Dx Rise Base, which contains the intuitive touch-screen interface and robotic system that moves and scans the cartridges within the device and 2) Between 1 through 8 Analytical Modules, letting you test up to eight samples at once. \u003c\/p\u003e\n\u003cp\u003eWith QIAstat-Dx Rise in your lab, you can: \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGain time away from your instruments\u003c\/strong\u003e: Batch process up to 16 cartridges using 8 Analytical modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess priority tests fast\u003c\/strong\u003e: Get random access through 2 additional urgent testing slots. \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad and go:\u003c\/strong\u003e Load the full capacity of cartridges in just a few minutes and safely dispose of used tests in one step.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003ePlus, every QIAstat-Dx Analytical Module is compatible with both QIAstat-Dx Analyzer 2.0 and QIAstat-Dx Rise. Easily update your QIAstat-Dx testing format based on your evolving testing needs. \u003ca href=\"https:\/\/www.qiagen.com\/products\/diagnostics-and-clinical-research\/infectious-disease\/qiastat-dx-syndromic-testing\/qiastat-dx\" rel=\"noopener\" target=\"_blank\"\u003eClick here\u003c\/a\u003e to more about QIAstat-Dx Analyzer 2.0, our modular system perfect for labs of every size.\u003c\/p\u003e\u003cp\u003eThe QIAstat-Dx Rise Base is a benchtop in vitro diagnostic device for use with QIAstat-Dx assays and QIAstat-Dx Analytical Modules. It provides full automation from sample preparation to real-time PCR detection. This higher-throughput system can accommodate up to 160 patient samples per day using 8 Analytical Modules.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUses real-time PCR to deliver comprehensive results for up to 160 patient samples per day with 8 Analytical Modules\u003c\/li\u003e\n\u003cli\u003eEasily view Ct values and amplification curves for all detected pathogens\u003c\/li\u003e\n\u003cli\u003eSingle-step cartridge preparation with no precision pipetting required and unique direct swab protocol\u003c\/li\u003e\n\u003cli\u003eLoad the full capacity of cartridges in just a few minutes and safely dispose of all used cartridges from the waste tray in one quick step\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePrinciple\u003c\/h2\u003e\u003cp\u003eQIAstat-Dx Rise, combined with QIAstat-Dx assay cartridges, uses real-time PCR to detect pathogen nucleic acids in human biological samples. The instrument and cartridges are designed as a closed system that contain on board all necessary reagents, enabling hands-off sample preparation. Detected real-time amplification signals are interpreted by the integrated software and are reported via an intuitive user interface.\u003c\/p\u003e\u003ch2\u003eProcedure\u003c\/h2\u003e\u003cp\u003ePreparing a QIAstat-Dx cartridge using liquid transfer or dry swab sample application is efficient and fast. And once the cartridges are ready, it takes just a few minutes to load the full capacity of cartridges and start a run on QIAstat-Dx Rise. \u003c\/p\u003e\n\u003cp\u003eLoading a sample into the QIAstat-Dx cartridge requires less than one minute hands-on time with no precision pipetting.\u003c\/p\u003e\n\u003cp\u003eUsing the provided transfer pipette, the user applies a liquid sample to the main port of the QIAstat-Dx cartridge (see Applying a liquid sample to the QIAstat-Dx cartridge). Alternatively for our respiratory assay, a dry swab sample may be directly applied to the cartridge (Applying a dry swab to the QIAstat-Dx cartridge).\u003c\/p\u003e\n\u003cp\u003eFollowing the instructions on the QIAstat-Dx Rise touchscreen display, the user loads the prepared cartridges into the instrument’s loading tray (see Adding cartridges to the QIAstat-Dx Rise input tray).\u003c\/p\u003e\n\u003cp\u003eThe QIAstat-Dx Rise will automatically scan the sample ID and cartridge barcodes, or the user can manually scan the barcodes. Once the user starts the run, the QIAstat-Dx Rise will autonomously process the samples. \u003c\/p\u003e\n\u003cp\u003eThe input tray also offers random and continuous access, meaning an urgent test can be added to an ongoing run at a moment’s notice. \u003c\/p\u003e\n\u003cp\u003eOnce the run is finished, the used cartridges are automatically placed in the dedicated waste tray so they can be disposed of safely and quickly.\u003c\/p\u003e\u003ch2\u003eApplications\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eQIAstat-Dx Respiratory SARS-CoV-2 Panel (V2)\u003c\/strong\u003e: Qualitative test to analyze 23 viral and bacterial respiratory targets for common pathogens causing respiratory infections, including SARS-CoV-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQIAstat-Dx Respiratory SARS-CoV-2 Panel (V2) – 23 bacterial and viral pathogens\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eViruses\u003c\/th\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003cth\u003eBacteria\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfluenza A\u003c\/td\u003e\n\u003ctd\u003eParainfluenza virus 1\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfluenza A subtype H1N1\/2009\u003c\/td\u003e\n\u003ctd\u003eParainfluenza virus 2\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfluenza A subtype H1\u003c\/td\u003e\n\u003ctd\u003eParainfluenza virus 3\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfluenza A subtype H3\u003c\/td\u003e\n\u003ctd\u003eParainfluenza virus 4\u003c\/td\u003e\n\u003ctd\u003e\u003cem\u003eMycoplasma pneumoniae\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfluenza B\u003c\/td\u003e\n\u003ctd\u003eRespiratory syncytial virus A\/B\u003c\/td\u003e\n\u003ctd\u003e\u003cem\u003eLegionella pneumophilia\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoronavirus 229E\u003c\/td\u003e\n\u003ctd\u003eHuman metapneumovirus A\/B\u003c\/td\u003e\n\u003ctd\u003e\u003cem\u003eBordetella pertussis\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoronavirus HKU1\u003c\/td\u003e\n\u003ctd\u003eAdenovirus\u003c\/td\u003e\n\u003ctd\u003e\u003cem\u003eChlamydophila pneumoniae\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoronavirus NL63\u003c\/td\u003e\n\u003ctd\u003eBocavirus\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoronavirus OC43\u003c\/td\u003e\n\u003ctd\u003eRhinovirus\/Enterovirus*\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSARS-CoV-2\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e*Enterovirus and Rhinovirus are both detected, but not differentiated, with the QIAstat-Dx Respiratory SARS-CoV-2 Panel.\u003c\/p\u003e\n\u003cp\u003eThe QIAstat-Dx Respiratory SARS-CoV-Panel (V2) is currently available in select countries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQIAstat-Dx Gastrointestinal Panel 2\u003c\/strong\u003e: Qualitative test to analyze 22 of the most common pathogens causing gastrointestinal infections, including differentiation of Shiga-like toxin producing \u003cem\u003eE. coli\u003c\/em\u003e (STEC) stx1 and stx2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQIAstat-Dx Gastrointestinal Panel 2 – 23 targets, corresponding to 22 bacterial, viral and parasitic pathogens\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eBacteria\u003c\/th\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003cth\u003eViruses\u003c\/th\u003e\n\u003cth\u003eParasites\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003eCampylobacter (C. jejuni, C. upsaliensis, C. coli)\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cem\u003eSalmonella \u003c\/em\u003espp.\u003c\/td\u003e\n\u003ctd\u003e\u003cem\u003eAdenovirus F40\/41\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cem\u003eCryptosporidium\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eClostridium difficile\u003c\/em\u003e (toxin A\/B)\u003c\/td\u003e\n\u003ctd\u003eShiga-like toxin-producing \u003cem\u003eE. coli\u003c\/em\u003e (STEC) stx1 and stx2 (including specific identification of \u003cem\u003eE. coli\u003c\/em\u003e O157 serogroup within STEC)**\u003c\/td\u003e\n\u003ctd\u003eAstrovirus\u003c\/td\u003e\n\u003ctd\u003e\u003cem\u003eCyclospora cayetanensis\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnteroaggregative \u003cem\u003eE. coli\u003c\/em\u003e (EAEC)\u003c\/td\u003e\n\u003ctd\u003e\u003cem\u003eVibrio vulnificus\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003eNorovirus (GI, GII)\u003c\/td\u003e\n\u003ctd\u003e\u003cem\u003eEntamoeba histolytica\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cem\u003eShigella\u003c\/em\u003e\/Enteroinvasive \u003cem\u003eE. coli\u003c\/em\u003e (EIEC)\u003c\/td\u003e\n\u003ctd\u003e\u003cem\u003eVibrio parahaemolyticus\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003eRotavirus A\u003c\/td\u003e\n\u003ctd\u003e\u003cem\u003eGiardia lamblia\u003c\/em\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnteropathogenic \u003cem\u003eE. coli\u003c\/em\u003e (EPEC)\u003c\/td\u003e\n\u003ctd\u003e\u003cem\u003eVibrio cholerae\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003eSapovirus (GI, GII, GIV, GV)\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnterotoxigenic \u003cem\u003eE. coli\u003c\/em\u003e (ETEC) \u003cem\u003elt\/st\u003c\/em\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cem\u003eYersinia enterocolitica\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cem\u003ePlesiomonas shigelloides\u003c\/em\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e**The stx1 and stx2 toxin genes of STEC are reported separately by the QIAstat-Dx Gastrointestinal Panel 2.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeatures\u003c\/th\u003e\n\u003cth\u003eSpecifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eModular syndromic testing system with QIAstat-Dx Rise Base, up to 8 QIAstat-Dx Analytical Modules and 1 QIAstat-Dx Rise Mobile Table (optional).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument dimensions (WxHxD)\u003c\/td\u003e\n\u003ctd\u003eQIAstat-Dx Rise Base (door closed): 580 x 1280 x 810 mm (22.8 x 50.4 x 31.9 in) \u003cbr\u003eQIAstat-Dx Rise Base (door open): 1500 mm x 1280 x 810 mm (59 x 50.4 x 31.9 in)\u003cbr\u003eFor installation and service interventions, 1.5 m of space around the instrument is required.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eQIAstat-Dx Rise Base: 130 kg\u003cbr\u003eQIAstat-Dx Analytical Module: 16 kg\u003cbr\u003eQIAstat-Dx Rise Mobile Table (load-bearing capacity): 300 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower requirements\u003c\/td\u003e\n\u003ctd\u003e200–240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended clearance\u003c\/td\u003e\n\u003ctd\u003eLeft side: 80 cm\u003cbr\u003eTop: 32 cm\u003cbr\u003eFront: 140 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating conditions\u003c\/th\u003e\n\u003cth\u003eSpecifications\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir temperature\u003c\/td\u003e\n\u003ctd\u003e15–28 ̊C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e20–80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003e0–2200 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlace of operation\u003c\/td\u003e\n\u003ctd\u003eLaboratory (inside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.qiagen.com\/gb\/resources\/usermanual\/hb-3570-001-qsg-qiastat-dx-rise-0524\" target=\"_blank\" rel=\"noopener\"\u003eQIAstat-Dx Rise Quick-Start Guide\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. no.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eContents\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e9003163\u003c\/td\u003e\n\u003ctd\u003eQIAstat-Dx Rise Base\u003c\/td\u003e\n\u003ctd\u003eThe QIAstat-Dx Rise Base is a benchtop in vitro diagnostic device for use with QIAstat-Dx assays and QIAstat-Dx Analytical Modules. It provides full automation from sample preparation to real-time PCR detection. This higher-throughput system can accommodate up to 160 patient samples per day using 8 Analytical Modules.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"QIAGEN","offers":[{"title":"Default Title","offer_id":46798467203151,"sku":"9003163","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/1_5_WebFullSizeImage.jpg?v=1789653374","url":"https:\/\/www.danyel.co.il\/products\/qiagen-qiastat-dx-rise-high-throughput-syndromic-testing-system-9003163","provider":"danyel biotech","version":"1.0","type":"link"}