{"product_id":"qiagen-qiastat-dx-gastrointestinal-panel-2-691413","title":"QIAstat-Dx Gastrointestinal Panel 2","description":"\u003cp\u003e\u003cstrong\u003eQIAstat-Dx Gastrointestinal Panel 2\u003c\/strong\u003e – Qualitative test to analyze 22 most common pathogens causing gastrointestinal infections, including differentiation of Shiga-like toxin producing E. coli (STEC) stx1 and stx2 .\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003eQIAstat-Dx Gastrointestinal Panel 2 – 23 pathogens, corresponding to 22 bacterial, \u003cem\u003eviral and parasitic pathogens\u003c\/em\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eBacteria\u003c\/th\u003e\n\u003cth\u003eViruses\u003c\/th\u003e\n\u003cth\u003eParasites\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eCampylobacter (C. jejuni, C. upsaliensis, C. coli)\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eClostridium difficile\u003c\/em\u003e (toxin A\/B)\u003c\/p\u003e\n\u003cp\u003eEnteroaggregative \u003cem\u003eE. coli\u003c\/em\u003e (EAEC)\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eShigella\u003c\/em\u003e\/Enteroinvasive\u003cem\u003e E. coli\u003c\/em\u003e (EIEC)\u003c\/p\u003e\n\u003cp\u003eEnteropathogenic \u003cem\u003eE. coli\u003c\/em\u003e (EPEC)\u003c\/p\u003e\n\u003cp\u003eEnterotoxigenic \u003cem\u003eE. coli\u003c\/em\u003e (ETEC) \u003cem\u003elt\/st\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003ePlesiomonas shigelloides\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eSalmonella\u003c\/em\u003e spp.\u003c\/p\u003e\n\u003cp\u003eShiga-like toxin-producing \u003cem\u003eE. coli\u003c\/em\u003e (STEC) \u003cem\u003estx1\u003c\/em\u003e and \u003cem\u003estx2\u003c\/em\u003e (including specific identification of E. coli O157 serogroup within STEC)*\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eVibrio vulnificus\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eVibrio parahaemolyticus\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eVibrio cholerae\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eYersinia enterocolitica\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eAdenovirus F40\/41\u003c\/p\u003e\n\u003cp\u003eAstrovirus\u003c\/p\u003e\n\u003cp\u003eNorovirus (GI, GII)\u003c\/p\u003e\n\u003cp\u003eRotavirus A\u003c\/p\u003e\n\u003cp\u003eSapovirus (GI, GII, GIV, GV)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e\u003cem\u003eCryptosporidium\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eCyclospora cayetanensis\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eEntamoeba histolytica\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eGiardia lamblia\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e*The \u003cem\u003estx1\u003c\/em\u003e and \u003cem\u003estx2\u003c\/em\u003e toxin genes of STEC are reported separately by the QIAstat-Dx Gastrointestinal Panel 2.\u003c\/p\u003e\u003cp\u003e6 individually packaged cartridges containing all reagents needed for sample preparation and multiplex real-time RT-PCR, plus internal control, including six transfer pipettes.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIntuitive workflow with minimal hands-on time\u003c\/li\u003e\n\u003cli\u003eUses real-time PCR to deliver comprehensive results in about an hour\u003c\/li\u003e\n\u003cli\u003eEasily view Ct values and amplification curves for all detected pathogens\u003c\/li\u003e\n\u003cli\u003eNo precision pipetting required and unique direct swab protocol for input into the cartridge\u003c\/li\u003e\n\u003cli\u003eQIAsphere-connected for real-time updates, proactive remote service and custom epidemiology reports\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003ePrinciple\u003c\/h2\u003e\u003cp\u003eThe QIAstat-Dx Analyzers 1.0 and 2.0, combined with QIAstat-Dx assay cartridges, use real-time PCR to detect pathogen nucleic acids in human biological samples. The cartridges are designed as closed systems containing the necessary reagents for automated sample processing, following a simple sample preparation and loading step.  Detected real-time amplification signals are interpreted by the integrated software and are reported via an intuitive user interface.\u003c\/p\u003e\u003ch2\u003eProcedure\u003c\/h2\u003e\u003cp\u003eSetting up and running a QIAstat-Dx test requires minimal hands-on time and just a few simple steps. \u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAdd the patient sample to the main port of the QIAstat-Dx cartridge using the plastic pipette provided. For our respiratory panels, you can alternatively apply the sample with a dry swab. This step is fast and easy to perform and requires no precision pipetting.\u003c\/li\u003e\n\u003cli\u003ePress the Run Test button on the QIAstat-Dx touch screen and scan the sample ID barcode.\u003c\/li\u003e\n\u003cli\u003eScan the barcode of the cartridge you’re using.\u003c\/li\u003e\n\u003cli\u003ePosition the cartridge on the instrument’s sample port. The cartridge will automatically move in and the test will start.\u003c\/li\u003e\n\u003cli\u003eAfter about an hour, view the comprehensive results.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.qiagen.com\/gb\/resources\/kithandbookandprotocol\/hb-3462-002-ivdr-r1-qiastat-dx-gi-panel-2-1124-ce-row\" target=\"_blank\" rel=\"noopener\"\u003eQIAstat-Dx Gastrointestinal Panel 2 Instructions for Use (IVDR)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.qiagen.com\/gb\/resources\/scientificdocument\/qiastatdx-gi2-ce-ivdr-an-lv-row\" target=\"_blank\" rel=\"noopener\"\u003eGuidelines for Laboratory Verification of Performance of QIAstat-Dx Gastrointestinal Panel 2 (IVDR)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.qiagen.com\/gb\/resources\/scientificdocument\/prom-21582-001-an-qiastat-dx-gi2-panel-verification-0922-row\" target=\"_blank\" rel=\"noopener\"\u003eGuidelines for Laboratory Verification of Performance of the QIAstat-Dx Gastrointestinal Panel 2\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. no.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eContents\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e691413\u003c\/td\u003e\n\u003ctd\u003eQIAstat-Dx Gastrointestinal Panel 2\u003c\/td\u003e\n\u003ctd\u003e6 individually packaged cartridges containing all reagents needed for sample preparation and multiplex real-time RT-PCR, plus internal control, including six transfer pipettes.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cem\u003eThe QIAstat-Dx instruments and QIAstat-Dx panels are intended for in vitro diagnostic use. \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eFor up-to-date licensing information and product-specific disclaimers, see the respective QIAGEN kit instructions for use or user manual. QIAGEN instructions for use and user manuals are available at www.qiagen.com or can be requested from QIAGEN Technical Services (or your local distributor). \u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eProduct availability may differ from country to country based on regulations and approvals. Contact your country representative for further details.\u003c\/em\u003e\u003c\/p\u003e","brand":"QIAGEN","offers":[{"title":"Default Title","offer_id":46798468087887,"sku":"691413","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/1_5_WebFullSizeImage_35120cb0-6c15-4b1c-bb29-96f9af9f227d.jpg?v=1789653387","url":"https:\/\/www.danyel.co.il\/products\/qiagen-qiastat-dx-gastrointestinal-panel-2-691413","provider":"danyel biotech","version":"1.0","type":"link"}