{"product_id":"novaseq-6000-sequencing-system-20012850","title":"NovaSeq 6000 Sequencing System","description":"\u003cp\u003eThe NovaSeq 6000 Sequencing System is an integrated ultrahigh throughput system performing onboard cluster generation and sequencing. This system includes installation and training and 12 months warranty (including parts and labor).\u003c\/p\u003e\n\u003cp\u003eNovaSeq 6000 System expands sequencing capabilities by combining throughput, flexibility, and simplicity for virtually any method, genome, and scale.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTried and true performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eSystem specifications\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cspan\u003eOutput range\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cspan\u003e80–6000 Gb\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cspan\u003eSingle reads per run\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cspan\u003e650M–20B\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cspan\u003eMax read length\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cspan\u003e2 × 250 bp\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cspan\u003eRun time\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cspan\u003e13–44 hr\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eA flexible workflow designed to help you accelerate your research and maximize results\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eManage workflow\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eManage your workflow seamlessly with Clarity LIMS software or your existing LIMS system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003ePrepare libraries\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003ePrepare libraries with a broad range of high-performance library preparation kits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eSequence\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eGenerate sequences with ready-to-use reagents featuring proven Illumina sequencing by synthesis chemistry.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eAnalyze data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eLeverage Illumina DRAGEN software or BaseSpace Sequence Hub for accurate, rapid secondary analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eInterpret results\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eGain insights and drive discovery with variant analysis and interpretation software.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced applications. Impactful discoveries.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe NovaSeq 6000 System offers deep, broad coverage through advanced applications for a comprehensive view of the genome. Unlock a full spectrum of genetic variation and biological function with high-throughput sequencing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOutput per flow cell for various read lengths\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRead length\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eSP\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 × 35 bp\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e280–350 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 50 bp\u003c\/td\u003e\n\u003ctd\u003e65–80 Gb\u003c\/td\u003e\n\u003ctd\u003e134–167 Gb\u003c\/td\u003e\n\u003ctd\u003e333–417 Gb\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 100 bp\u003c\/td\u003e\n\u003ctd\u003e134–167 Gb\u003c\/td\u003e\n\u003ctd\u003e266–333 Gb\u003c\/td\u003e\n\u003ctd\u003e667–833 Gb\u003c\/td\u003e\n\u003ctd\u003e1600–2000 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 150 bp\u003c\/td\u003e\n\u003ctd\u003e200–250 Gb\u003c\/td\u003e\n\u003ctd\u003e400–500 Gb\u003c\/td\u003e\n\u003ctd\u003e1000–1250 Gb\u003c\/td\u003e\n\u003ctd\u003e2400–3000 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 250 bp\u003csup\u003eb\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e325-400 Gb\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEstimated sample throughput for key applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eSP\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHuman genomes per run\u003c\/td\u003e\n\u003ctd\u003e~4\u003c\/td\u003e\n\u003ctd\u003e~8\u003c\/td\u003e\n\u003ctd\u003e~20\u003c\/td\u003e\n\u003ctd\u003e~48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExomes per run\u003c\/td\u003e\n\u003ctd\u003e~40\u003c\/td\u003e\n\u003ctd\u003e~80\u003c\/td\u003e\n\u003ctd\u003e~200\u003c\/td\u003e\n\u003ctd\u003e~500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTranscriptomes per run\u003c\/td\u003e\n\u003ctd\u003e~32\u003c\/td\u003e\n\u003ctd\u003e~64\u003c\/td\u003e\n\u003ctd\u003e~164\u003c\/td\u003e\n\u003ctd\u003e~400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eReads passing filter per flow cell\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRead type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eSP\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle-end reads\u003c\/td\u003e\n\u003ctd\u003e650–800M\u003c\/td\u003e\n\u003ctd\u003e1.3–1.6B\u003c\/td\u003e\n\u003ctd\u003e3.3–4.1B\u003c\/td\u003e\n\u003ctd\u003e8–10B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePaired-end reads\u003c\/td\u003e\n\u003ctd\u003e1.3–1.6B\u003c\/td\u003e\n\u003ctd\u003e2.6–3.2B\u003c\/td\u003e\n\u003ctd\u003e6.6–8.2B\u003c\/td\u003e\n\u003ctd\u003e16–20B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eQuality scores\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRead length\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eSP\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 × 35 bp\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e≥ 90% of bases higher than Q30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 50 bp\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e≥ 90% of bases higher than Q30\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 100 bp\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≥ 85% of bases higher than Q30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 150 bp\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e≥ 85% of bases higher than Q30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 250 bp\u003c\/td\u003e\n\u003ctd\u003e≥ 75% of bases higher than Q30\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRun time\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRead length\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003eSP\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS1\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 × 35 bp\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e~14 hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 50 bp\u003c\/td\u003e\n\u003ctd\u003e~13 hr\u003c\/td\u003e\n\u003ctd\u003e~13 hr\u003c\/td\u003e\n\u003ctd\u003e~16 hr\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 100 bp\u003c\/td\u003e\n\u003ctd\u003e~19 hr\u003c\/td\u003e\n\u003ctd\u003e~19 hr\u003c\/td\u003e\n\u003ctd\u003e~25 hr\u003c\/td\u003e\n\u003ctd\u003e~36 hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 150 bp\u003c\/td\u003e\n\u003ctd\u003e~25 hr\u003c\/td\u003e\n\u003ctd\u003e~25 hr\u003c\/td\u003e\n\u003ctd\u003e~36 hr\u003c\/td\u003e\n\u003ctd\u003e~44 hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 250 bp\u003c\/td\u003e\n\u003ctd\u003e~38 hr\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina-marketing\/documents\/products\/appnotes\/novaseq-wgs-app-note-770-2017-015.pdf\"\u003eHuman Whole-Genome Sequencing with the NovaSeq 6000 Sequencing System\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina-marketing\/documents\/products\/appnotes\/novaseq-hiseq-q30-app-note-770-2017-010.pdf\"\u003eNovaSeq 6000 System Quality Scores and RTA3 Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina-marketing\/documents\/products\/technotes\/novaseq-xp-workflow-tech-note-770-2018-014.pdf\"\u003eThe NovaSeq Xp workflow provides flexibility and control without sacrificing data quality or yield\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina-marketing\/documents\/products\/appnotes\/illumina-dna-pcr-free-wgs-app-note-770-2020-006.pdf\"\u003eHigh-performance whole-genome sequencing with Illumina DNA PCR-Free Prep, Tagmentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina-marketing\/documents\/products\/flyers\/proactive-system-connectivity-guide-novaseq.pdf\"\u003eIllumina Proactive Service connectivity guide - NovaSeq 6000\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSupport Documentation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/novaseq-6000-system-guide-1000000019358.html\"\u003eNovaSeq 6000 Sequencing System Guide Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/novaseq-site-prep-guide-1000000019360.html\"\u003eNovaSeq 6000 Sequencing System Site Prep Guide Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/novaseq-safety-compliance-guide-1000000019357.html\"\u003eNovaSeq 6000 Sequencing System Safety and Compliance Guide Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/novaseq-custom-primers-guide-1000000022266.html\"\u003eNovaSeq Series Custom Primers Guide Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/novaseq-xp-workflow-checklist-1000000044404.html\"\u003eNovaSeq Xp Workflow Checklist Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/sequencing\/sequencing_instruments\/novaseq-6000.html\"\u003eAll NovaSeq 6000 System Support\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Illumina","offers":[{"title":"Default Title","offer_id":46487053598799,"sku":"20012850","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/hires-novaseq6000-front.jpg?v=1787652003","url":"https:\/\/www.danyel.co.il\/products\/novaseq-6000-sequencing-system-20012850","provider":"danyel biotech","version":"1.0","type":"link"}