{"product_id":"ngs-star-line-806600","title":"NGS STAR Line","description":"\u003cp\u003eHamilton NGS STAR helps streamline next-generation sequencing (NGS) in labs. Achieve optimized full NGS automation for library preparation. Enhance efficiency, precision, and reliability in your workflows. Explore the Hamilton NGS STAR Line for seamless sequencing today!\u003c\/p\u003e\u003ch3\u003eEverlasting Reliability in NGS Workflows\u003c\/h3\u003e\u003cp\u003eThe NGS STAR Line evolves along with your sequencing workflow automation needs to deliver high-quality results long into the future.\u003c\/p\u003e\u003ch3\u003eDPS - Dynamic Positioning System\u003c\/h3\u003e\u003cp\u003eDPS enables all channels to pipette simultaneously, even across non-uniform patterns. Unlike fixed channels with equidistant spreading, DPS offers efficient yet flexible liquid handling for cherry picking, non-uniform and variable volume samples, and complex pipetting workflows.\u003c\/p\u003e\u003ch3\u003eCO-RE II Tip\/Tool Attachment\u003c\/h3\u003e\u003cp\u003eThe Key to Liquid Handling Workflow Excellence\u003c\/p\u003e\u003cp\u003eThe new CO-RE II technology assures more precise tip alignment, minimizing the risk of collisions. Also, tip coupling is faster which boosts productivity. Besides tips, a wide range of Hamilton tools are applicable with CO-RE II.\u003c\/p\u003e\u003ch3\u003eAerosol-Free Tip Ejection\u003c\/h3\u003e\u003cp\u003eAs part of CO-RE II technology’s functionality, pipette tips are gently ejected from each automated liquid handler pipetting channel. This prevents aerosol generation that may expose users to harmful biohazards or cross-contaminate samples and laboratory surfaces.\u003c\/p\u003e\u003ch3\u003ePlug-and-Play Convenience\u003c\/h3\u003e\u003cp\u003eWith all devices, modules, and software necessary for impactful NGS library prep in one system, you can rapidly set up and deploy the NGS STAR Line.\u003c\/p\u003e\u003ch3\u003eExplore the NGS STAR Line\u003c\/h3\u003e\u003cp\u003eDecklayouts between NGS STAR and NGS STAR MOA do slightly differ due to different pipetting hardware (NGS STAR MOA deck shown as reference).\u003c\/p\u003e\u003cp\u003eEmpty positions can be used to expand according to application needs.\u003c\/p\u003e\u003ch4\u003eUltraviolet Light Package, Optional\u003c\/h4\u003e\u003cp\u003eDecontaminates and sterilizes exposed surfaces on the deck of the NGS STAR Line to support workflow integrity.\u003c\/p\u003e\u003ch4\u003eOn-Deck Thermalcycler (ODTC), Optional\u003c\/h4\u003e\u003cp\u003eThermal cycling with adjustable settings for high precision and reproducibility. Supports most 96-well PCR plates. Use with the PCR ComfortLid. Accessible with the CO-RE 96-Probe Head.\u003c\/p\u003e\u003ch4\u003eConsumables and Reagent Storage\u003c\/h4\u003e\u003cp\u003eThe deck layout offers ample storage space for CO-RE II tips, plates, and reagent reservoirs, with automatic barcode scanning to verify proper placement.\u003c\/p\u003e\u003ch4\u003eProcessing Positions\u003c\/h4\u003e\u003cp\u003eA dedicated zone manages all pipetting steps using MIDI and PCR plates. An integrated magnet plate is used for magnetic bead-based purification steps.\u003c\/p\u003e\u003ch4\u003eTemperature incubation and mixing\u003c\/h4\u003e\u003cp\u003eIncludes 5 Hamilton Heater Shakers (HHS) with speed up to 2500 rpm and heating up to 105 ºC, along with 1 Cold Plate Air Cooled Heater\/Cooler (CPAC).\u003c\/p\u003e\u003ch4\u003eTransportation Tool\u003c\/h4\u003e\u003cp\u003eAgile CO-RE Grippers and optional iSWAP (for ODTC integration) support hands-free processing by reliably moving plates around the deck throughout the workflow.\u003c\/p\u003e\u003ch4\u003eAutomated Loading and Scanning\u003c\/h4\u003e\u003cp\u003eAutoloading and barcode verification enable full sample traceability while verifying proper consumable and reagent loading and placement.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eNGS STAR\u003c\/th\u003e\n\u003cth\u003eNGS STAR MOA\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90.3 cm (2 ft, 11.55 in)\u003c\/td\u003e\n\u003ctd\u003e90.3 cm (2 ft, 11.55 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.66 m (5 ft, 5.51 in)\u003c\/td\u003e\n\u003ctd\u003e1.93 m (6 ft, 3.87 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78.1 cm (2 ft, 6.75 in)\u003c\/td\u003e\n\u003ctd\u003e78.1 cm (2 ft, 6.75 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCO-RE Gripper\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Plate Gripper (IPG)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCapacity (ANSI\/SLAS Positions)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Loading\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutoload Barcode Scanner (1D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutoload Barcode Scanner (2D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003ctd\u003eOptional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1 mL Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMulti-Probe Head Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003en\/a\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePipetting Range 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 µL - 1000 µL\u003c\/td\u003e\n\u003ctd\u003e1 µL - 1000 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003ePart No.\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e806600\u003c\/td\u003e\n\u003ctd\u003eNGS STAR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e806603\u003c\/td\u003e\n\u003ctd\u003eNGS STAR UV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e806605\u003c\/td\u003e\n\u003ctd\u003eNGS STAR MOA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e806607\u003c\/td\u003e\n\u003ctd\u003eNGS STAR MOA UV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hamilton Company","offers":[{"title":"NGS STAR","offer_id":46787538321487,"sku":"806600","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"NGS STAR UV","offer_id":46787538354255,"sku":"806603","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"NGS STAR MOA","offer_id":46787538387023,"sku":"806605","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"NGS STAR MOA UV","offer_id":46787538419791,"sku":"806607","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/71ed80188e73dc39.jpg?v=1789547067","url":"https:\/\/www.danyel.co.il\/products\/ngs-star-line-806600","provider":"danyel biotech","version":"1.0","type":"link"}