{"product_id":"nextseq-550dx-sequencing-system-20005715","title":"NextSeq 550Dx Sequencing System","description":"\u003cp\u003eThe NextSeq 550Dx instrument is intended for sequencing of DNA libraries when used with in vitro diagnostic assays performed on the instrument. The NextSeq 550Dx instrument is to be used with specific registered, certified or approved in vitro diagnostic reagents and analytical software. The instrument includes a dual boot configuration to enable the use of the instrument in either diagnostic (Dx) or research use only (RUO) mode. In vitro diagnostic sequencing assays, including the Germline and Somatic Variant Modules, are executed in diagnostic mode. Only IVD sequencing reagents can be utilized in diagnostic mode.\u003c\/p\u003e\n\u003cp\u003eThe NextSeq 550Dx Instrument is an IVD-regulated next-generation sequencing instrument for clinical diagnostics and IVD assay development.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe reliability and quality of a clinical instrument\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eInstrument specifications\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cspan\u003eOutput\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cspan\u003e90 Gb\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cspan\u003ePaired-end reads per run\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cspan\u003e≥ 300M\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cspan\u003eMax read length\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cspan\u003e2 × 150 bp\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cspan\u003eRun time\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cspan\u003e\u0026lt; 35 hr\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified three-step workflow\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe NextSeq 550Dx Instrument is easily configured, scalable, and user-friendly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003ePrepare libraries\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eBenefit from a pipeline of IVD tests in development or design your own. Generate indexed libraries and create runs in Local Run Manager.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eSequence\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eAdd library to the ready-to-use NextSeq 550Dx reagent cartridge, load, and start run. Generate data \u0026lt; 35 hours.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eAnalyze data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eAutomatically launch data analysis with Local Run Manager and get results in a few hours. Leverage BaseSpace apps for additional analysis options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostic and clinical research applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eRun IVD assays using targeted panels and a wide range of clinical research applications, including exome sequencing, targeted gene sequencing, whole-transcriptome sequencing, and cytogenomic arrays.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eIntended Use for the NextSeq 550Dx Instrument\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eUnited States:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe NextSeq 550Dx Instrument is intended for targeted sequencing of DNA libraries from human genomic DNA extracted from peripheral whole blood or formalin-fixed, paraffin-embedded (FFPE) tissue when used with \u003cem\u003ein vitro\u003c\/em\u003e (IVD) diagnostic assays. The NextSeq 550Dx Instrument is not intended for whole genome or \u003cem\u003ede novo\u003c\/em\u003e sequencing. The NextSeq 550Dx Instrument is to be used with specific registered, certified, or approved \u003cem\u003ein vitro\u003c\/em\u003e diagnostic reagents and analytical software.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eEuropean Union:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe NextSeq 550Dx instrument is intended for sequencing of DNA libraries when used with \u003cem\u003ein vitro\u003c\/em\u003e diagnostic assays. The NextSeq 550Dx instrument is to be used with specific registered, certified, or approved \u003cem\u003ein vitro\u003c\/em\u003e diagnostic reagents and analytical software.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eNextSeq 550Dx Instrument — NextSeq 550Dx High-Output Reagent Kit v2.5 (300 cycles)\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRead length\u003c\/th\u003e\n\u003cth\u003eOutput\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 150 bp\u003c\/td\u003e\n\u003ctd\u003e90 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003cth\u003eNextSeq 550Dx High-Output Reagent Kit v2.5 (300 cycles)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePaired-end reads\u003c\/td\u003e\n\u003ctd\u003e≥ 600M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRead length\u003c\/th\u003e\n\u003cth\u003eQuality\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 150 bp\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 75% bases higher than Q30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRead length\u003c\/th\u003e\n\u003cth\u003eRun time\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 150 bp\u003c\/td\u003e\n\u003ctd\u003e≤ 35 hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSomatic variant caller\u003c\/td\u003e\n\u003ctd\u003e≥ 99.98%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGermline variant caller\u003c\/td\u003e\n\u003ctd\u003e≥ 99.99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/nextseq-550-dx-spec-sheet-m-gl-00035\/nextseq-550-dx-instrument-spec-sheet-m-gl-00035.pdf\"\u003eNextSeq 550Dx Instrument Spec Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/dragen-server-for-nextseq-550dx-data-sheet-m-gl-01471\/dragen-server-for-nextseq-550dx-data-sheet-m-gl-01471.pdf\"\u003eIllumina DRAGEN™ Server for NextSeq™ 550Dx Sequencing Instruments\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/illumina-dx-brochure-m-gl-00769\/illumina-dx-brochure-m-gl-00769.pdf\"\u003eIllumina Dx platforms and solutions brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/sequencing-platforms-brochure-m-gl-00451\/sequencing-platforms-brochure-m-gl-00451.pdf\"\u003eIllumina Sequencing Platforms Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/dragen-server-for-nextseq-550dx-app-note-m-gl-01470\/dragen-server-for-nextseq-550dx-app-note-m-gl-01470.pdf\"\u003eAccurate, IVDR-compliant NGS variant calling using the Illumina DRAGEN Server for NextSeq 550Dx Instruments\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/truseq-custom-amplicon-dx-data-sheet-m-gl-00973\/truseq-custom-amplicon-dx-kit-data-sheet-m-gl-00973.pdf\"\u003eTruSeq Custom Amplicon Kit Dx\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSupport Documentation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/nextseq-550dx-instrument-package-insert-1000000030326.html\"\u003eNextSeq 550Dx Instrument Package Insert (IVD) Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/nextseq-550dx-instrument-reference-guide-1000000009513.html\"\u003eNextSeq 550Dx Instrument Reference Guide Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/nextseq-550dx-instrument-software-release-notes.html\"\u003eNextSeq 550Dx Instrument Software Release Notes Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/nextseq-550dx-high-output-reagent-kit-v2-300-cycles-package-insert-1000000036666.html\"\u003eNextSeq 550Dx High Output Reagent Kit v2 (300 Cycles) Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/illumina-run-manager-for-nextseq-550dx-software-guide-200025239.html\"\u003eIllumina Run Manager for NextSeq 550Dx Software Guide Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/indexed-sequencing-overview-15057455.html\"\u003eIndexed Sequencing Overview Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Illumina","offers":[{"title":"Default Title","offer_id":46487036592207,"sku":"20005715","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/hires-nextseq550dx-front.jpg?v=1787652001","url":"https:\/\/www.danyel.co.il\/products\/nextseq-550dx-sequencing-system-20005715","provider":"danyel biotech","version":"1.0","type":"link"}