{"product_id":"nextseq-550-sequencing-system-sy-415-1002","title":"NextSeq 550 Sequencing System","description":"\u003cp\u003eIllumina NextSeq 550 Sequencing System is an integrated system for automated generation of DNA clonal clusters by bridge amplification, sequencing, primary analysis, and array scanning. System includes embedded touchscreen monitor and on-instrument computer, NextSeq Control Software, installation and training, and 12 months warranty (including parts and labor).\u003c\/p\u003e\n\u003cp\u003eThe NextSeq 550 System provides flexible power to enable benchtop sequencing and array capabilities across a range of applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReliable benchtop sequencing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eSystem Specifications\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cspan\u003eOutput range\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cspan\u003e16.25 - 120 Gb\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cspan\u003eReads per run\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cspan\u003e130 - 400 million\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cspan\u003eMax read length\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cspan\u003e2 × 150 bp\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cspan\u003eRun time\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cspan\u003e12 -30 hr\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eOne simple, integrated workflow from prep to analysis\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003ePrep\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003ePrepare libraries for a range of applications with a large menu of Illumina library prep options.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eSequence\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eGenerate data in less than one day with automated sequencing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eAnalyze\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eLeverage DRAGEN secondary analysis via an on-premises server or on BaseSpace Sequence Hub for applications such as exome and transcriptome sequencing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eShare\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eShare data instantly on BaseSpace Sequence Hub and enable secure, expandable storage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eDive deeper\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eFrom gene expression profiling to small whole-genome sequencing, the NextSeq 550 System provides reliable, accessible insights with integrated sequencing and array scanning capabilities.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOutput per flow cell for various read lengths\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRead length\u003c\/th\u003e\n\u003cth\u003eNextSeq 550 System Mid-Output Kit\u003c\/th\u003e\n\u003cth\u003eNextSeq 550 System High-Output Kit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 × 75 bp\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e25–30 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 75 bp\u003c\/td\u003e\n\u003ctd\u003e16.25–19.5 Gb\u003c\/td\u003e\n\u003ctd\u003e50–60 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 150 bp\u003c\/td\u003e\n\u003ctd\u003e32.5–39 Gb\u003c\/td\u003e\n\u003ctd\u003e100–120 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEstimated sample throughput for key applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eNextSeq 550 System Mid-Output Kit\u003c\/th\u003e\n\u003cth\u003eNextSeq 550 System High-Output Kit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 exomes\u003c\/td\u003e\n\u003ctd\u003e1 whole human genome\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12 enrichment panels\u003c\/td\u003e\n\u003ctd\u003e12 exomes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e96 amplicon panels\u003c\/td\u003e\n\u003ctd\u003e16 transcriptomes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eReads passing filter per flow cell\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e \u003c\/th\u003e\n\u003cth\u003eNextSeq 550 System Mid-Output Kit\u003c\/th\u003e\n\u003cth\u003eNextSeq 550 System High-Output Kit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSingle reads\u003c\/td\u003e\n\u003ctd\u003e≤ 130M\u003c\/td\u003e\n\u003ctd\u003e≤ 400M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePaired-end reads\u003c\/td\u003e\n\u003ctd\u003e≤ 260 M\u003c\/td\u003e\n\u003ctd\u003e≤ 800 M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eQuality scores\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRead length\u003c\/th\u003e\n\u003cth\u003eNextSeq 550 System Mid-Output Kit\u003c\/th\u003e\n\u003cth\u003eNextSeq 550 System High-Output Kit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 × 75 bp\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80% bases higher than Q30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 75 bp\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80% bases higher than Q30 at 2 × 75 bp\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 80% bases higher than Q30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 150 bp\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 75% bases higher than Q30 at 2 × 150 bp\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 75% bases higher than Q30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRun time\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRead length\u003c\/th\u003e\n\u003cth\u003eNextSeq 550 System Mid-Output Kit\u003c\/th\u003e\n\u003cth\u003eNextSeq 550 System High-Output Kit\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 × 75 bp\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e11 hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 75 bp\u003c\/td\u003e\n\u003ctd\u003e15 hr\u003c\/td\u003e\n\u003ctd\u003e18 hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 × 150 bp\u003c\/td\u003e\n\u003ctd\u003e26 hr\u003c\/td\u003e\n\u003ctd\u003e29 hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eArray scanning parameters\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eArray\u003c\/th\u003e\n\u003cth\u003eScan time per array\u003c\/th\u003e\n\u003cth\u003eScan time per sample\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfinium MethylationEPIC BeadChip\u003c\/td\u003e\n\u003ctd\u003e40 min\u003c\/td\u003e\n\u003ctd\u003e5 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInfinium CytoSNP-850K BeadChip\u003c\/td\u003e\n\u003ctd\u003e40 min\u003c\/td\u003e\n\u003ctd\u003e5 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina-marketing\/documents\/products\/appnotes\/nipt-nextseq-500-hiseq-application-note-1570-2014-053.pdf\"\u003eLaboratory Experience Using Illumina Next-Generation Sequencing for Noninvasive Prenatal Testing Application Note\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina-marketing\/documents\/products\/appnotes\/nextera-dna-flex-direct-colony-app-note-770-2017-036.pdf\"\u003eDirect Bacterial Colony Sequencing with the Nextera™ DNA Flex Library Preparation Kit\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina-marketing\/documents\/products\/appnotes\/illumina-dna-pcr-free-microbial-app-note-770-2020-005.pdf\"\u003eMicrobial whole-genome sequencing with Illumina DNA PCR-Free Prep, Tagmentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/sequencing-platforms-brochure-m-gl-00451\/sequencing-platforms-brochure-m-gl-00451.pdf\"\u003eIllumina Sequencing Platforms Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/nextseq-550-amplicon-app-note-770-2014-027\/nextseq-550-amplicon-app-note-770-2014-027.pdf\"\u003eNextSeq 550 amplicon sequencing solution\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/nextseq-550-exome-app-note-770-2013-047\/nextseq-550-exome-app-note-770-2013-047.pdf\"\u003eNextSeq 550 exome sequencing solution\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSupport Documentation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/nextseq-500-release-notes.html\"\u003eNextSeq System Suite Release Notes Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/sequencing\/sequencing_software\/sequencing_analysis_viewer_sav\/computing_requirements.html\"\u003eSequencing Analysis Viewer (SAV) Computing Requirements Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/nextseq-500-safety-and-compliance-guides.html\"\u003eNextSeq System Safety and Compliance Guides Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/nextseq-500-550-systems-product-documentation.html\"\u003eNextSeq 500 and NextSeq 550 Sequencing Systems Product Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/networking-security.html\"\u003eSecurity and Networking Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/denature-and-dilute-protocol-generator.html\"\u003eDenature and Dilute Protocol Generator Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Illumina","offers":[{"title":"Default Title","offer_id":46487033053263,"sku":"SY-415-1002","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/hires-nextseq550-front.jpg?v=1787652001","url":"https:\/\/www.danyel.co.il\/products\/nextseq-550-sequencing-system-sy-415-1002","provider":"danyel biotech","version":"1.0","type":"link"}