{"product_id":"miseqdx-system-dx-410-1001","title":"MiSeqDx System","description":"\u003cp\u003eIncludes one MiSeqDx Instrument with embedded touch screen monitor and on-instrument computer, dual surface imaging capability, MiSeq Software Suite, installation kits, installation and training, and 12 months warranty (including parts and labor) to support automated generation of DNA clonal clusters by bridge amplification, sequencing, and primary and secondary analysis. Qualification services, instrument service plans, and reagent kits sold separately.\u003c\/p\u003e\n\u003cp\u003eAvailable in \u0026gt; 45 countries, the MiSeqDx is an in vitro diagnostic (IVD) next-generation sequencing instrument for diagnostics and clinical research.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTailored to the diverse needs of clinical labs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eSystem specifications\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cspan\u003eOutput range\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cspan\u003e≥ 5 Gb\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cspan\u003ePaired-end reads per run\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cspan\u003e ≥ 15M\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cspan\u003eMax read length\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cspan\u003e2 × 150 bp\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eResults based on MiSeqDx Reagent Kit v3.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eSimple, comprehensive solution for clinical laboratory environments\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eFrom library prep to informatics, the MiSeqDx Instrument provides easy-to-follow workflows and integrated software that deliver accurate, reliable screening and diagnostic testing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eManage workflow\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eManage your workflow seamlessly with Clarity LIMS or your existing LIMS system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003ePrepare libraries\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eChoose from a menu of FDA-cleared assays available exclusively on the MiSeqDx Instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eSequence\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eProduce sequences with ready-to-use reagents featuring proven Illumina sequencing by synthesis chemistry.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eAnalyze data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eAnalyze data automatically at the completion of a run with Local Run Manager.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eInterpret results\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eGenerate detailed reports using TruSight Software Suite.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eOne instrument. Many applications.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eWith the flexibility to operate in either Research Use Only (RUO) or Dx Mode, the MiSeqDx Instrument can conduct clinical research, develop, and run a range of IVD assays on the same instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eIntended Use for the MiSeqDx Instrument\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eUnited States:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe MiSeqDx Instrument is intended for targeted sequencing of DNA libraries from human genomic DNA extracted from peripheral whole blood, formalin-fixed, paraffin-embedded (FFPE) tissue, or embryonic tissue, when used with \u003cem\u003ein vitro\u003c\/em\u003e diagnostic (IVD) assays performed on the instrument. The MiSeqDx Instrument is not intended for whole genome or \u003cem\u003ede novo\u003c\/em\u003e sequencing. The MiSeqDx Instrument is to be used with registered and listed, cleared, or approved IVD reagents and analytical software.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eEuropean Union\/other:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe MiSeqDx Instrument is intended for targeted sequencing of DNA libraries from human genomic DNA extracted from peripheral whole blood or formalin-fixed, paraffin-embedded (FFPE) tissue, when used with \u003cem\u003ein vitro\u003c\/em\u003e diagnostic (IVD) assays performed on the instrument. The MiSeqDx Instrument is not intended for whole genome or \u003cem\u003ede novo\u003c\/em\u003e sequencing. The MiSeqDx Instrument is to be used with registered and listed, cleared, or approved IVD reagents and analytical software.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOutput per flow cell for various read lengths\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRead length\u003c\/th\u003e\n\u003cth\u003eMiSeqDx Reagent Kit v3\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 x 150 bp\u003c\/td\u003e\n\u003ctd\u003e≥ 5 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eEstimated sample throughput for key applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSample type\u003c\/th\u003e\n\u003cth\u003eMiSeqDx Reagent Kit v3\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHuman peripheral whole blood for cystic fibrosis testing\u003c\/td\u003e\n\u003ctd\u003e24-96 samples per run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eReads passing filter per flow cell\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSample type\u003c\/th\u003e\n\u003cth\u003eMiSeqDx Reagent Kit v3\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePaired-end reads\u003c\/td\u003e\n\u003ctd\u003e≥ 15M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eQuality scores\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRead length\u003c\/th\u003e\n\u003cth\u003eMiSeqDx Reagent Kit v3\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 x 150 bp\u003c\/td\u003e\n\u003ctd\u003e≥ 80% of bases higher than Q30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRun time\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eRead length\u003c\/th\u003e\n\u003cth\u003eMiSeqDx Reagent Kit v3\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 x 150 bp\u003c\/td\u003e\n\u003ctd\u003e24 hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTotal overall accuracy\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVariant calling\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGermline\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 99.9% overall percent agreement to reference results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSomatic\u003c\/td\u003e\n\u003ctd\u003e100% overall percent agreement to reference result\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eTotal overall reproducibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVariant calling\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGermline\u003c\/td\u003e\n\u003ctd\u003e99.88% overall percent agreement to reference results\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSomatic\u003c\/td\u003e\n\u003ctd\u003e99.6% percent expected call for mutant sample\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina-marketing\/documents\/products\/datasheets\/data-sheet-miseqdx-instrument-1000000006405.pdf\"\u003eMiSeqDx Instrument Specification Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/miseqdx-instrument-data-sheet-m-na-00005\/miseqdx-instrument-data-sheet-m-na-00005.pdf\"\u003eMiSeqDx Instrument specification sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/illumina-dx-brochure-m-gl-00769\/illumina-dx-brochure-m-gl-00769.pdf\"\u003eIllumina Dx platforms and solutions brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/sequencing-platforms-brochure-m-gl-00451\/sequencing-platforms-brochure-m-gl-00451.pdf\"\u003eIllumina Sequencing Platforms Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina-marketing\/documents\/clinical\/can-ngs-replace-sanger-sequencing.pdf\"\u003eCan Next-Generation Sequencing Replace Sanger Sequencing?\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina-marketing\/documents\/products\/datasheets\/factsheet_cystic_fibrosis.pdf\"\u003eCystic Fibrosis Fact Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSupport Documentation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/miseqdx-instrument-package-insert-for-mos-v4-EU.html\"\u003eMiSeqDx Instrument Package Insert for MOS v4 (EU\/ROW) Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/local-run-manager-v3-software-guide-for-miseqdx.html\"\u003eLocal Run Manager v3 Software Reference Guide for MiSeqDx Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/local-run-manager-somatic-variant-module-workflow-guide-for-miseqdx-1000000012183.html\"\u003eLocal Run Manager Somatic Variant Analysis Module Workflow Guide for MiSeqDx Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/miseqdx-software-system-release-notes.html\"\u003eMiSeqDx Software System Release Notes Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/local-run-manager-v4-software-guide-for-miseqdx.html\"\u003eLocal Run Manager v4 Software Reference Guide for MiSeqDx Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Illumina","offers":[{"title":"Default Title","offer_id":46487049666639,"sku":"DX-410-1001","price":125000.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/hires-miseqdx-front.jpg?v=1787652004","url":"https:\/\/www.danyel.co.il\/products\/miseqdx-system-dx-410-1001","provider":"danyel biotech","version":"1.0","type":"link"}