{"product_id":"miseq-i100-plus-system-20115695","title":"MiSeq i100 Plus System","description":"\u003cp\u003eThe MiSeq i100 Plus System is a benchtop sequencing system that integrates sequencing, primary analysis and secondary analysis. The system includes embedded touchscreen monitor and on-instrument computer, control software, hardware-accelerated DRAGEN secondary analysis pipelines, and 12 months warranty (including parts and labor). The system is self-installable by the customer and does not include installation services.\u003c\/p\u003e\n\u003cp\u003eThe MiSeq i100 Series delivers our fastest run times yet, breakthrough simplicity, and significant sustainability advancements to empower every lab.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIncredible speed for same-day results\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eSame-day (and same-shift) results are now possible. The MiSeq i100 and MiSeq i100 Plus Systems provide results 4× faster than the MiSeq System, with sequencing run times as fast as four hours.\u003c\/p\u003e\n\u003cp\u003eWith the expanded output offered by the MiSeq i100 Series, you can increase sample throughput, perform deeper sequencing, and gain more insights for a wide range of applications faster than ever. XLEAP-SBS chemistry on the MiSeq i100 Series eliminates thawing requirements so reagents can be used whenever your sample is ready.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eThe MiSeq i100 Series makes NGS simpler than ever\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eEvery aspect of the MiSeq i100 Series workflow is noticeably simplified, from setup to data analysis. Whether you are new to sequencing or an experienced user, you’ll appreciate the streamlined operations. Run setup requires only three steps and can be completed in less than 20 minutes.\u003c\/p\u003e\n\u003cp\u003eIntegrated cartridges simplify library loading and eliminate the need for washes between runs, improving sequencing efficiency.\u003c\/p\u003e\n\u003cp\u003eGenerate data analysis summaries in two hours or less for most applications by accessing preconfigured DRAGEN pipelines, either onboard or in the cloud.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eGround-breaking sustainability innovations\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eIn addition to breakthrough advancements in system design, XLEAP-SBS chemistry, and integrated data analysis, the MiSeq i100 Series is optimized to reduce environmental impact. Key innovations, such as an 85% reduction in packaging waste and a 35% reduction in the total carbon footprint, plus room-temperature ship-and-store consumables, deliver remarkable sustainability and user experience benefits.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOutput per flow cell for various read lengths\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow cell type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan\u003e5M\u003c\/span\u003e\u003c\/strong\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan\u003e25M\u003c\/span\u003e\u003c\/strong\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003e50M\u003c\/strong\u003e\u003csup\u003eb\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003e100M\u003c\/strong\u003e\u003csup\u003eb\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e1 × 100 bp\u003c\/th\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e2.5 Gb\u003c\/td\u003e\n\u003ctd\u003e5 Gb\u003c\/td\u003e\n\u003ctd\u003e10 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e2 × 150 bp\u003c\/th\u003e\n\u003ctd\u003e1.5 Gb\u003c\/td\u003e\n\u003ctd\u003e7.5 Gb\u003c\/td\u003e\n\u003ctd\u003e15 Gb\u003c\/td\u003e\n\u003ctd\u003e30 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e2 × 300 bp\u003c\/th\u003e\n\u003ctd\u003e3 Gb\u003c\/td\u003e\n\u003ctd\u003e15 Gb\u003c\/td\u003e\n\u003ctd\u003e30 Gb\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e2 × 500 bp\u003c\/th\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e25 Gb\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eReads passing filter per flow cell\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow cell type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan\u003e5M\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan\u003e25M\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003e50M\u003c\/strong\u003e\u003csup\u003eb\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003e100M\u003c\/strong\u003e\u003csup\u003eb\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSingle reads\u003c\/th\u003e\n\u003ctd\u003e5M\u003c\/td\u003e\n\u003ctd\u003e25M\u003c\/td\u003e\n\u003ctd\u003e50M\u003c\/td\u003e\n\u003ctd\u003e100M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePaired-end reads\u003c\/th\u003e\n\u003ctd\u003e10M\u003c\/td\u003e\n\u003ctd\u003e50M\u003c\/td\u003e\n\u003ctd\u003e100M\u003c\/td\u003e\n\u003ctd\u003e200M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSequencing data quality\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow cell type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003e5M\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003e25M\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003e50M\u003c\/strong\u003e\u003csup\u003eb\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003e100M\u003c\/strong\u003e\u003csup\u003eb\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e1 × 100 bp\u003c\/th\u003e\n\u003ctd colspan=\"4\"\u003e≥ 90% of bases higher than Q30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e2 × 150 bp\u003c\/th\u003e\n\u003ctd colspan=\"4\"\u003e≥ 90% of bases higher than Q30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e2 × 300 bp\u003c\/th\u003e\n\u003ctd colspan=\"4\"\u003e≥ 85% of bases higher than Q30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e2 × 500 bp\u003c\/th\u003e\n\u003ctd colspan=\"4\"\u003e≥ 85% of bases higher than Q30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eRun time\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"0\" width=\"100%\"\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFlow cell type\u003c\/th\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan\u003e5M\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e\u003cspan\u003e25M\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003e50M\u003c\/strong\u003e\u003csup\u003ea\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cspan\u003e\u003cstrong\u003e100M\u003c\/strong\u003e\u003csup\u003ea\u003c\/sup\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e1 × 100 bp\u003c\/th\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e~ 4 hr\u003c\/td\u003e\n\u003ctd\u003e~ 4.5 hr\u003c\/td\u003e\n\u003ctd\u003e~ 5 hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e2 × 150 bp\u003c\/th\u003e\n\u003ctd\u003e~ 7 hr\u003c\/td\u003e\n\u003ctd\u003e~ 7 hr\u003c\/td\u003e\n\u003ctd\u003e~ 7.5 hr\u003c\/td\u003e\n\u003ctd\u003e~ 8 hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e2 × 300 bp\u003c\/th\u003e\n\u003ctd\u003e~ 15 hr\u003c\/td\u003e\n\u003ctd\u003e~ 15 hr\u003c\/td\u003e\n\u003ctd\u003e~ 15.5 hr\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e2 × 500 bp\u003c\/th\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e~ 24 hr\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/miseq-i100-brochure-m-gl-02245\/miseq-i100-brochure-m-gl-02245.pdf\"\u003eSimplest, fastest. For Every Lab.\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/miseq-i100-sustainability-infographic-m-gl-02696\/miseq-i100-sustainability-infographic-m-gl-02696.pdf\"\u003eThe new standard in sequencing sustainably\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/miseq-i100-data-concordance-app-note-m-gl-02246\/miseq-i100-data-concordance-app-note-m-gl-02246.pdf\"\u003eHigh-accuracy next-generation sequencing with the MiSeq i100 Series\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/miseq-i100-library-qc-app-note-m-gl-02871\/miseq-i100-library-qc-app-note-m-gl-02871.pdf\"\u003eLibrary QC with the MiSeq i100 Series\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/miseq-i100-hiv-app-note-m-gl-03571\/miseq-i100-hiv-app-note-m-gl-03571.pdf\"\u003eSequencing the HIV genome on the MiSeq i100 Series\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/miseq-i100-wastewater-surveillance-app-note-m-gl-02915\/miseq-i100-wastewater-surveillance-app-note-m-gl-02915.pdf\"\u003eTrack emerging infectious diseases with wastewater surveillance\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSupport Documentation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/sequencing\/sequencing_instruments\/miseq-i100-plus\/documentation.html\"\u003eMiSeq i100 Series Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/miseq-i100-series-product-documentation.html\"\u003eMiSeq i100 Series Product Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/miseq-i100-series-release-notes.html\"\u003eMiSeq i100 Series Software Release Notes Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/downloads\/network-installation-prep-tool.html\"\u003eNetwork Installation Preparation Tool Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/sequencing\/sequencing_instruments\/miseq-i100-plus.html\"\u003eAll MiSeq i100 Series Support\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Illumina","offers":[{"title":"Default Title","offer_id":46487044948047,"sku":"20115695","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/hires-miseq-i100-front_9a235158-0aaa-4cca-98f4-c1427caaf95f.jpg?v=1787652003","url":"https:\/\/www.danyel.co.il\/products\/miseq-i100-plus-system-20115695","provider":"danyel biotech","version":"1.0","type":"link"}