{"product_id":"mag-bind-totalpure-ngs-m1378-00","title":"Mag-Bind® TotalPure NGS","description":"\u003cp\u003eThe Mag-Bind® TotalPure NGS Kit allows for double or single-sided size selection. Purified PCR products can be used for myriad downstream applications such as microarrays, restriction enzyme digestion, and sequencing. Our Mag-Bind® magnetic bead-based technology provides an optimal alternative to centrifugation and vacuum-based extractions. This system is automatable on most open liquid handlers and magnetic processors.\u003c\/p\u003e\n\u003cp\u003eMag-Bind® TotalPure NGS offers an easy-to-use, reliable solution for the purification of DNA or RNA for Next Generation Sequencing workflows with high recovery rates. Mag-Bind TotalPure NGS is capable of selectively binding fragments depending on the reagent-to-sample ratio used, giving the user flexibility to perform left, right, or double-sided size selection. This product is designed for both manual or fully automated purification of DNA and RNA samples, as well as for the purification of PCR products. The system combines Omega Bio-tek’s proprietary chemistries with reversible nucleic acid binding properties of magnetic beads to selectively bind fragments larger than 100 bp and eliminate excess nucleotides, primers, and small, non-targeted products such as primer-dimers. Purified DNA and RNA are suitable for a variety of downstream applications such as NGS library preparation, microarrays, automated fluorescent sequencing, and restriction enzyme digestion.\u003c\/p\u003e\n\u003cp\u003eFor Research Use Only. Not for use in diagnostic procedures.\u003c\/p\u003e\n\u003cp\u003eFigure 1. Electropherogram overlay of the double-sided size selection on sheared gDNA at 0.8x\/0.7x ratio set using Omega Bio-tek’s Mag-Bind® TotalPure NGS and a comparable kit from Company A following manufacturer’s recommended protocols. The DNA was eluted in 25 µL and analyzed on Agilent’s TapeStation® 2200.\u003c\/p\u003e\n\u003cp\u003eFigure 2. 10 µL of 50 bp ladder was purified with Omega Bio-tek’s Mag-Bind® TotalPure NGS and a comparable product from Company A following manufacturer’s recommended protocols. The DNA was eluted in 20 µL and analyzed on Agilent’s TapeStation® 2200.\u003c\/p\u003e\n\u003cp\u003eFigure 3. 10 µL of RNA at 50 ng\/µL and 5 ng\/µL was cleaned up with Omega Bio-tek’s Mag-Bind® TotalPure NGS following manufacturer’s recommended protocols. The RNA was eluted in 20 µL and analyzed on Agilent’s TapeStation® 2200. Recovery rates were 85-92% respectively.\u003c\/p\u003e\n\u003cp\u003eDouble-Sided Size Selection for NGS Library Prep\u003c\/p\u003e\n\u003cp\u003eFigure 4. Next-generation sequencing libraries prepared from 350 ng sheared genomic DNA using Kapa Biosystem’s HyperPrep Kits (KK8504) and Omega Bio-tek’s Mag-Bind® TotalPure NGS and a comparable product from Company A on the Hamilton Microlab® STAR™. Mag-Bind® TotalPure NGS was used for 2 clean up step (0.8x and 1.0x) following Kapa Biosystems’ recommended protocol for clean up. DNA was analyzed on Agilent’s TapeStation® 2200 following library construction.\u003c\/p\u003e\n\u003cp\u003eTapeStation Analysis of DNA Post-Cleanup at Different Bead-to-Sample Ratios\u003c\/p\u003e\n\u003cp\u003eFigure 5. TapeStation analysis was performed on 25 μL of 20X diluted 50 bp ladder following cleanup with Mag-Bind TotalPure NGS beads on Tecan Fluent 780 workstation and an unprocessed 50 bp ladder as a control. The fragment sizes of DNA eluted after different cleanup ratios are as shown above.\u003c\/p\u003e\n\u003cp\u003ePercentage of DNA Omitted at Different Bead:Sample Ratios\u003c\/p\u003e\n\u003cp\u003eFigure 6. Average percentage of DNA removed (n=4) at various fragment sizes at different volume ratios of Mag-Bind TotalPure NGS beads to input sample volume. Cleanup was performed using the Tecan Fluent 780 workstation. Note: Negative percentages are reported as 0%.\u003c\/p\u003e\n\u003cp\u003eFigure 7. Comparison of average percentage of DNA removed (n=4) at various bead:sample ratios following automated protocol on the Tecan Fluent 780 workstation to that of the data reported in [1]. Note: Negative percentages are reported as 0%.\u003c\/p\u003e\n\u003cp\u003eEvaluation of Omega Mag-Bind® TotalPure NGS Beads for DNA Size Selection. Genomics \u0026amp; Cell Characterization Core Facility, University of Oregon Technical Note – http:\/\/gc3fstorage.uoregon.edu\/IMAGES\/Evaluation_of_Omega_ Mag-Bind_TotalPure_NGS_Beads_MWeitzman_April2018.pdf.\u003c\/p\u003e\n\u003cp\u003eFigure 8. 3.8 ng of DNA input was purified using Omega Bio-tek’s Mag-Bind® TotalPure NGS both manually, following manufacturer’s instructions, and automated on the Hamilton Microlab® STAR™. The average recovery for the automated method was 2.98 ng, or about 80% recovery rate, which is typical for DNA cleanup using this product.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo protocol changes against major competitor\u003c\/li\u003e\n\u003cli\u003eNGS: Double or single-sided size selection\u003c\/li\u003e\n\u003cli\u003eDNA cleanup: PCR cleanup\u003c\/li\u003e\n\u003cli\u003eRNA cleanup: cDNA or RNA purification\u003c\/li\u003e\n\u003cli\u003eProduced in an RNase-free environment for RNA cleanup applications\u003c\/li\u003e\n\u003cli\u003eManual or adaptable to most open-ended liquid handlers\u003c\/li\u003e\n\u003cli\u003eSignificant cost savings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCloning\u003c\/li\u003e\n\u003cli\u003eNGS\u003c\/li\u003e\n\u003cli\u003eIn Vitro Transcription\u003c\/li\u003e\n\u003cli\u003eNucleic Acid Labeling\u003c\/li\u003e\n\u003cli\u003ePCR\u003c\/li\u003e\n\u003cli\u003eReal-Time Quantitative PCR (qPCR)\u003c\/li\u003e\n\u003cli\u003eSequencing\u003c\/li\u003e\n\u003cli\u003eSouthern Blotting\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDownstream application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCloning, NGS, In Vitro Transcription, Nucleic Acid Labeling, PCR, Real-Time Quantitative PCR (qPCR), Sequencing, Southern Blotting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElution volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 µL or above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStarting material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDNA or RNA: PCR products, gDNA, cDNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStarting amount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScalable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDNA recovered\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;90% recovery for DNA \u0026gt;100 bp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessing mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomated; manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThroughput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96-384 samples per run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDNA binding technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMagnetic beads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2°C – 8°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecial note\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSize selection by varying beads ratio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Omega Bio-tek","offers":[{"title":"Mag-Bind® TotalPure NGS – 5 mL","offer_id":46733016694863,"sku":"M1378-00","price":720.0,"currency_code":"ILS","in_stock":true},{"title":"Mag-Bind® TotalPure NGS – 50 mL","offer_id":46733016727631,"sku":"M1378-01","price":3956.0,"currency_code":"ILS","in_stock":true},{"title":"Mag-Bind® TotalPure NGS – 500 mL","offer_id":46733016760399,"sku":"M1378-02","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/MagneticBeads-M1378-M1386-copy.webp?v=1782734846","url":"https:\/\/www.danyel.co.il\/products\/mag-bind-totalpure-ngs-m1378-00","provider":"danyel biotech","version":"1.0","type":"link"}