{"product_id":"kta-pure-chromatography-system-29018226","title":"ÄKTA pure™ chromatography system","description":"\u003cp\u003eThe ÄKTA pure™ chromatography system is a versatile and modular system designed for reliable purification of biomolecules, including proteins, peptides and nucleic acids. Major features:\u003c\/p\u003e\n\u003cp\u003e• Modular system design: Supports a wide range of alternatives for any type of purification processes from basic to advanced automated applications\n• UNICORN™ control software: Facilitates intuitive method creation, system control, and evaluation\n• Reliable system: With components and integrated features based on the proven design of ÄKTA protein purification systems\n• Predefined method settings: For all our laboratory-scale chromatography columns\n• Practical size: Easy placement on laboratory bench or in cold cabinet\u003c\/p\u003e\n\u003cp\u003eChoose the ÄKTA pure system that fits your purification journey\u003c\/p\u003e\n\u003cp\u003eÄKTA pure™ 25: Ideal for a broad range of research applications and purification tasks in multiuser labs.\u003c\/p\u003e\n\u003cp\u003eÄKTA pure™ 150: Supports higher sample loads and throughput, helping you maximize productivity and streamline routine large-scale purifications.\u003c\/p\u003e\n\u003cp\u003eÄKTA pure™ T: With 2 fixed wavelengths at 260 and 280 nm ÄKTA pure™ T offers a way of addressing complex purification needs. Available in 25 mL\/min and 150 mL\/min formats, it retains the flexibility and additional module selection options as ÄKTA pure™ L and M. If you have an existing ÄKTA pure™ L chromatography system, it can be upgraded with the U9-T UV monitor to perform a broader set of applications.\u003c\/p\u003e\n\u003cp\u003eÄKTA pure ™ micro: Offers enhanced resolution and sharper peaks is ideal for supporting cryo-EM applications. Choose up to 3 wavelengths from 190 to 700 nm.\u003c\/p\u003e\n\u003cp\u003eA wide range of optional modules are available to customize the system according to specific purification needs. Use the Purify App tool build and visualize any ÄKTA pure™ system\u003c\/p\u003e\n\u003cp\u003eUNICORN™ control software is based on an integrated controller and an intuitive computer-based interface. Key benefits include:\u003c\/p\u003e\n\u003cp\u003e• Simple method creation: Drag-and-drop operations for creating chromatography methods.\n• Advanced method creation: Text instructions gives you the freedom to customize chromatography methods\n• Modular features: Includes column logbook and design of experiments (DoE) functionality.\n• Licensing options: Remote access for creating methods, evaluating results and purification monitoring.\u003c\/p\u003e\n\u003cp\u003eLearn more on the UNICORN™ software page\u003c\/p\u003e\n\u003cp\u003eVarious prepacked columns are available for different scales of purification, with options to pack your own columns with loose resins using the ÄKTA pure.\u003c\/p\u003e\n\u003cp\u003eFind the best resin or column for application and molecule type with the Purify App\u003c\/p\u003e\n\u003cp\u003eRegardless of the configuration, the ÄKTA pure system package includes:\u003c\/p\u003e\n\u003cp\u003e• Two bio-inert high-performance system pumps\n• System pressure monitor for column protection\n• Mixer for gradient mixing\n• Injection valve for sample application\n• UV monitor for biomolecule detection\n• Conductivity monitor for gradient verification\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eModular system design: Supports a wide range of alternatives for any type of purification processes from basic to advanced automated applications\u003c\/li\u003e\n\u003cli\u003eUNICORN™ control software: Facilitates intuitive method creation, system control, and evaluation\u003c\/li\u003e\n\u003cli\u003eReliable system: With components and integrated features based on the proven design of ÄKTA protein purification systems\u003c\/li\u003e\n\u003cli\u003ePredefined method settings: For all our laboratory-scale chromatography columns\u003c\/li\u003e\n\u003cli\u003ePractical size: Easy placement on laboratory bench or in cold cabinet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eÄKTA pure 25 L, ÄKTA pure 25 M, ÄKTA pure™ 25 T, ÄKTA pure™ 150 T: Flexible and intuitive chromatography system for fast purification of proteins and antibodies from microgram to gram scale.\u003c\/li\u003e\n\u003cli\u003eÄKTA pure 25 L, ÄKTA pure 25 M, ÄKTA pure™ micro: Affinity chromatography, size exclusion chromatography (SEC, also known as gel filtration), ion exchange chromatography, hydrophobic interaction chromatography, and reversed phase chromatography (RPC). For RPC runs use only Frac F9-R or F9-T.\u003c\/li\u003e\n\u003cli\u003eÄKTA pure 150 L, ÄKTA pure™ 150 M: Tailored and reliable chromatography system for fast purification of proteins, peptides, and nucleic acids from microgram to tens of gram levels of target product.\u003c\/li\u003e\n\u003cli\u003eÄKTA pure 150 L, ÄKTA pure™ 150 M, ÄKTA pure™ 25 T, ÄKTA pure™ 150 T: Affinity chromatography, size exclusion chromatography (SEC, also known as gel filtration), ion exchange chromatography, hydrophobic interaction chromatography, and reversed phase chromatography (RPC). For RPC runs use only Frac F9-R.\u003c\/li\u003e\n\u003cli\u003eÄKTA pure™ micro: Chromatography system for high-resolution purification in microliter scale.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eÄKTA pure 25 L (29018224)\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure range (system pump)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 20 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed at 280 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible and intuitive chromatography system for fast purification of proteins and antibodies from microgram to gram scale.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAffinity chromatography, size exclusion chromatography (SEC, also known as gel filtration), ion exchange chromatography, hydrophobic interaction chromatography, and reversed phase chromatography (RPC). For RPC runs use only Frac F9-R or F9-T.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomatic buffer preparation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutosampler injection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffer selection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpgradeable to 14 inlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe product fulfills valid directives and standards when used within the conditions specified in the user manual. The product must also be used in the same state as it was delivered from Cytiva.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e470 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow cell path length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mm (optional 5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 to 25 mL\/min (normal range), 0.01 to 50 mL\/min (column packing flow)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e629 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMultiple sample injection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpgradeable to 5 samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMultiple wavelength detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed wavelength\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMultistep purification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating pressure (sample pump) max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating pressure max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 MPa (2900 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP 21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePump type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiston pump, metering type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20% to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety certifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, ETL, UKCA, EAC, KC, RCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTubing i.d. (flow path)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e280 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eViscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.35 to 10.0 cP (system pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 to 120\/220 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e535 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH stability, cleaning-in-place (CIP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH stability, operational\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 to 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eÄKTA pure 25 M (29018226)\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure range (system pump)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 20 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti – choose up to 3 from 190nm to 700nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible and intuitive chromatography system for fast purification of proteins and antibodies from microgram to gram scale.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAffinity chromatography, size exclusion chromatography (SEC, also known as gel filtration), ion exchange chromatography, hydrophobic interaction chromatography, and reversed phase chromatography (RPC). For RPC runs use only Frac F9-R or F9-T.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomatic buffer preparation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutosampler injection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuffer selection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpgradeable to 14 inlets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe product fulfills valid directives and standards when used within the conditions specified in the user manual. The product must also be used in the same state as it was delivered from Cytiva.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e470 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow cell path length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mm (optional 0.5 mm and 10 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 to 25 mL\/min (normal range), 0.01 to 50 mL\/min (column packing flow)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e629 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMultiple sample injection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpgradeable to 5 samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMultiple wavelength detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 3 wavelengths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMultistep purification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating pressure (sample pump) max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating pressure max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 MPa (2900 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP 21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePump type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiston pump, metering type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20% to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety certifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCE, ETL, UKCA, EAC, KC, RCM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTubing i.d. (flow path)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUV wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e190 to 700 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eViscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.35 to 10.0 cP (system pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 to 120\/220 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e535 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 14 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH stability, cleaning-in-place (CIP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH stability, operational\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 to 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eÄKTA pure™ 25 T (29707636)\u003c\/strong\u003e\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure range (system pump)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 20 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual 260\/280 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFlexible and intuitive chromatography system for fast purification of proteins and antibodies from microgram to gram scale.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAffinity chromatography, size exclusion chromatography (SEC, also known as gel filtration), ion exchange chromatography, hydrophobic interaction chromatography, and reversed phase chromatography (RPC). For RPC runs use only Frac F9-R.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomatic buffer preparation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutosampler injection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThe product fulfills valid directives and standards when used within the conditions specified in the user manual. The product must also be used in the same state as it was delivered from Cytiva.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e470 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e629 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMultiple sample injection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUpgradeable to 5 samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMultistep purification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating pressure max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 MPa (2900 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP 21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePump type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePiston pump, metering type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelative humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20% to 95% (noncondensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety certifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2006\/42\/EC (MD), 2004\/108\/EC (EMC), 1999\/5\/EC (R\u0026amp;TTE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTubing i.d. (flow path)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eViscosity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.35 to 10.0 cP (system pump)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 to 120\/220 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 53 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e535 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH monitoring\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 14 (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH stability, cleaning-in-place (CIP)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH stability, operational\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 to 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-29502-pdf\" target=\"_blank\" rel=\"noopener\"\u003eData file: ALIAS Bio autosampler for ÄKTA pure and ÄKTA avant\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-16276-pdf\" target=\"_blank\" rel=\"noopener\"\u003eÄKTA pure™ chromatography systems\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/_UN7x62W9U2j0JId8NsGbw-pdf\" target=\"_blank\" rel=\"noopener\"\u003eUNICORN™ 7 software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-17730-pdf\" target=\"_blank\" rel=\"noopener\"\u003eÄKTA lab-scale systems: Overview and comparison\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-23665-pdf\" target=\"_blank\" rel=\"noopener\"\u003eHistidine-tagged protein purification and detection brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-29175-pdf\" target=\"_blank\" rel=\"noopener\"\u003eÄKTA™ avant and ÄKTA™ pure preventive maintenance heet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-17327-pdf\" target=\"_blank\" rel=\"noopener\"\u003eTraining and applications support for ÄKTA protein purification systems for research and process development\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-17578-pdf\" target=\"_blank\" rel=\"noopener\"\u003ePrepacked columns for ÄKTA™ systems: Selection guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-16297-pdf\" target=\"_blank\" rel=\"noopener\"\u003eÄKTA pure Unpacking Instruction\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-29488-pdf\" target=\"_blank\" rel=\"noopener\"\u003eÄKTA pure - Guide for connecting Light Scattering\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-17267-pdf\" target=\"_blank\" rel=\"noopener\"\u003eGood ÄKTA system practice Cue Cards\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29744403.zip\" target=\"_blank\" rel=\"noopener\"\u003eRTU Win 10 Image SP1 Software, release notes, and installation instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29740748.zip\" target=\"_blank\" rel=\"noopener\"\u003eÄKTA pure 25 Instrument Configuration software v2.4.0.8, Release notes and installation instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29740747.zip\" target=\"_blank\" rel=\"noopener\"\u003eÄKTA pure 150 Instrument Configuration software v2.3.0.7, release notes, and installation instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-33828-pdf\" target=\"_blank\" rel=\"noopener\"\u003eReal-Time Unit Software Release notes and installation instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29414475.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUNICORN Quick Installation Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29325017.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstall Injection Valve V9-J and V9M-J Instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/28968650.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstall optional outlet valves Instructions for Use\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29021461.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstall Conductivity Monitor C9n and C9M Instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/28968652.pdf\" target=\"_blank\" rel=\"noopener\"\u003eInstall Air Sensor L9\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29020658.pdf\" target=\"_blank\" rel=\"noopener\"\u003eÄKTA pure 25 Product Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/28969192.pdf\" target=\"_blank\" rel=\"noopener\"\u003eÄKTA avant, ÄKTA pcc, and ÄKTA pure Instructions for Use\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29142436.pdf\" target=\"_blank\" rel=\"noopener\"\u003eÄKTA Systems Column protection\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29503110.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUNICORN 7.6 Command-line Installation Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29503111.pdf\" target=\"_blank\" rel=\"noopener\"\u003eUNICORN 7.6 Installation Checklist\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRelated Products\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.cytivalifesciences.com\/en\/us\/products\/items\/bioprocess-modular-system-for-liquid-chromatography-p-11559\" target=\"_blank\" rel=\"noopener\"\u003eBioProcess Modular System for liquid chromatography\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.cytivalifesciences.com\/en\/us\/products\/items\/sample-inlet-valve-kit-v9-is-p-04826\" target=\"_blank\" rel=\"noopener\"\u003eSample Inlet Valve Kit V9-IS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.cytivalifesciences.com\/en\/us\/products\/items\/air-sensors-p-06273\" target=\"_blank\" rel=\"noopener\"\u003eAir Sensors for ÄKTA pilot 600™\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.cytivalifesciences.com\/en\/us\/products\/items\/akta-avant-p-06264\" target=\"_blank\" rel=\"noopener\"\u003eÄKTA™ avant chromatography system\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.cytivalifesciences.com\/en\/us\/products\/items\/superdex-peptide-32-300-p-05802\" target=\"_blank\" rel=\"noopener\"\u003eSuperdex Peptide 3.2\/300\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.cytivalifesciences.com\/en\/us\/products\/items\/aktapilot-system-p-05845\" target=\"_blank\" rel=\"noopener\"\u003eÄKTApilot™ system\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.cytivalifesciences.com\/en\/us\/products\/items\/akta-pcc-and-bioprocess-pcc-continuous-chromatography-systems-p-06265\" target=\"_blank\" rel=\"noopener\"\u003eÄKTA™ pcc and BioProcess pcc continuous chromatography systems\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.cytivalifesciences.com\/en\/us\/products\/items\/aktaxpress-p-06166\" target=\"_blank\" rel=\"noopener\"\u003eÄKTAxpress\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.cytivalifesciences.com\/en\/us\/products\/items\/aktaprime-plus-p-05771\" target=\"_blank\" rel=\"noopener\"\u003eÄKTAprime plus\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.cytivalifesciences.com\/en\/us\/products\/items\/injection-valve-v9-inj-p-05180\" target=\"_blank\" rel=\"noopener\"\u003eInjection Valve, V9-Inj\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"25 mL\/min \/ 0 to 20 MPa \/ Multi – choose up to 3 from 190nm to 700nm (29018226)","offer_id":45982352244815,"sku":"29018226","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"25 mL\/min \/ 0 to 20 MPa \/ Multi – choose up to 3 from 190nm to 700nm (29302479)","offer_id":45982352277583,"sku":"29302479","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"25 mL\/min \/ 0 to 20 MPa \/ Dual 260\/280 nm","offer_id":45982352310351,"sku":"29707636","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"25 mL\/min \/ 0 to 20 MPa \/ Fixed at 280 nm","offer_id":45982352343119,"sku":"29018224","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"150 mL\/min \/ 0 to 5 MPa \/ Multi – choose up to 3 from 190nm to 700nm","offer_id":45982352375887,"sku":"29046694","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"150 mL\/min \/ 0 to 5 MPa \/ Dual 260\/280 nm","offer_id":45982352408655,"sku":"29707638","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"150 mL\/min \/ 0 to 5 MPa \/ Fixed at 280 nm","offer_id":45982352441423,"sku":"29046665","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/tjh2RRYIRfiZhHgAmE7nSA-original-png_268b856f-d8e7-4f0b-9703-af76b423eab3.png?v=1788947758","url":"https:\/\/www.danyel.co.il\/products\/kta-pure-chromatography-system-29018226","provider":"danyel biotech","version":"1.0","type":"link"}