{"product_id":"kta-oligosynt-oligonucleotide-synthesizer-29628148","title":"ÄKTA oligosynt™ oligonucleotide synthesizer","description":"\u003cp\u003eThe ÄKTA oligosynt™ oligonucleotide synthesizer is a compact, fully automated oligonucleotide synthesizer built for research and process development laboratories. The system supports a robust and easily scalable oligonucleotide synthesis process and transfer to larger oligonucleotide synthesizers with high yield and quality.\u003c\/p\u003e\n\u003cp\u003eSystem benefits\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eThe broad synthesis scale and optimized hold-up volume combined with a small system footprint enable a broad and flexible use for research and development requirements.\u003c\/li\u003e\n\t\u003cli\u003eFlexible and easy method editing, and the interactive user interface offer ease of use and support scale-up requirements.\u003c\/li\u003e\n\t\u003cli\u003eRobust process control is supported by sensors measuring pressure, air, temperature, UV, and conductivity. Input from external modules is also possible.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe ÄKTA oligosynt’s open front ensures easy access to all modules and full ventilation. The flow path is optimized for achieving a low hold-up volume, limiting the dilution of expensive amidites and excessive use of reagents and solvents.\u003c\/p\u003e\n\n\u003cp\u003eModules included with the system include two high-precision pumps, a pressure monitor, two solvent valves, two amidite valves, a recirculation valve, a column valve, a waste valve, an I\/O-box, a UV monitor, and a conductivity monitor.\u003c\/p\u003e\n\n\u003cp\u003eComponents of the oligonucleotide synthesis platform\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eSoftware\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe ÄKTA oligosynt™ synthesizer is controlled by \u003ca href=\"\/shop\/cell-therapy\/software\/unicorn-7-p-05649\"\u003eUNICORN™ software\u003c\/a\u003e, which provides real-time control of the system. Basic methods for the desired target sequence can be created in minutes using pre-defined methods and the sequence editor. UNICORN™ software also supports evaluation of results. The method overview is transparent with limited use of macros.\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003eColumns\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cp\u003eCytiva offers a range of columns for oligonucleotide synthesis:\u003c\/p\u003e\n\n\u003ctable class=\"table table-striped\"\u003e\n\t\u003cthead\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003eProduct code\u003c\/th\u003e\n\t\t\t\u003cth\u003eName\/description\u003c\/th\u003e\n\t\t\t\u003cth\u003eScale at 350 μmol\/g\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/thead\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003ca href=\"\/shop\/oligonucleotide-synthesis\/columns\/small-stainless-steel-columns-p-00441\"\u003e18110110\u003c\/a\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eSmall stainless steel column 1.2 mL* †\u003c\/td\u003e\n\t\t\t\u003ctd\u003e10–50 μmol\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003ca href=\"\/shop\/oligonucleotide-synthesis\/columns\/small-stainless-steel-columns-p-00441\"\u003e18110113\u003c\/a\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eSmall stainless steel column 6.3 mL*\u003c\/td\u003e\n\t\t\t\u003ctd\u003e0.2 mmol\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003ca href=\"\/shop\/oligonucleotide-synthesis\/columns\/small-stainless-steel-columns-p-00441\"\u003e18110116\u003c\/a\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eSmall stainless steel column 12 mL*\u003c\/td\u003e\n\t\t\t\u003ctd\u003e0.5 mmol\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003ca href=\"\/shop\/oligonucleotide-synthesis\/columns\/small-stainless-steel-columns-p-00441\"\u003e18110119\u003c\/a\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eSmall stainless steel column 24 mL*\u003c\/td\u003e\n\t\t\t\u003ctd\u003e0.9 mmol\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003ca href=\"\/shop\/oligonucleotide-synthesis\/columns\/small-stainless-steel-columns-p-00441\"\u003e18110122\u003c\/a\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eSmall stainless steel column 48 mL*\u003c\/td\u003e\n\t\t\t\u003ctd\u003e1.9 mmol\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003ca href=\"\/shop\/oligonucleotide-synthesis\/columns\/fineline-35-oligo-column-for-oligopilot-oligonucleotide-synthesizers-p-04827\"\u003e28946841\u003c\/a\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eFineLINE™ 35 oligo column\u003c\/td\u003e\n\t\t\t\u003ctd\u003e1.1 – 3.0 mmol\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003ca href=\"\/shop\/oligonucleotide-synthesis\/columns\/axitide-columns-p-24235\"\u003e29358075\u003c\/a\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eAxiTide™ 50 column\u003c\/td\u003e\n\t\t\t\u003ctd\u003e2.3 – 6.1 mmol\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003e\u003ca href=\"\/shop\/chromatography\/columns\/process-columns\/fineline-chromatography-columns-p-06320\"\u003e18115298\u003c\/a\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003eFineLINE™ 70‡ column 4.5–12 mmol\u003c\/td\u003e\n\t\t\t\u003ctd\u003e4.5 – 12 mmol\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\t\u003ctbody\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp\u003eFineLINE™ and AxiTide™ columns have a flexibility in bed heights. Bed heights between 3 and 8 cm have been used for this table.\u003c\/p\u003e\n\n\u003cp\u003e* used with \u003ca href=\"\/shop\/column-holder-p-00439\"\u003ecolumn holder 18113845\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003e† 10 μmol scale using lower loaded support\u003c\/p\u003e\n\n\u003cp\u003e‡ Used with PFR O-rings and 10 μm filters ordered separately\u003c\/p\u003e\n\n\u003cp\u003e\u003cem\u003e\u003ca href=\"\/shop\/oligonucleotide-synthesis\/solid-supports\/primer-support-5g-for-dna-synthesis-p-01912\"\u003ePrimer Support™ 5G solid support\u003c\/a\u003e\u003c\/em\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe ÄKTA oligosynt™ synthesizer and compatible Cytiva columns are designed for use with Primer Support™ 5G polystyrene solid support. This high-loaded solid support for DNA or RNA oligonucleotide synthesis is available using standard DNA and RNA bases as well as with UnyLinker™ solid support as a starting point, making the solid support more flexible for DNA synthesis.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-51550-pdf\"\u003eData file (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29737074.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"Default Title","offer_id":45982469423183,"sku":"29628148","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-51348-original-png_a5dc3287-d1ce-4feb-839f-6aa14adc5e14.png?v=1785961362","url":"https:\/\/www.danyel.co.il\/products\/kta-oligosynt-oligonucleotide-synthesizer-29628148","provider":"danyel biotech","version":"1.0","type":"link"}