{"product_id":"e220-evolution-focused-ultrasonicator-500429","title":"E220 evolution Focused-ultrasonicator","description":"\u003cp\u003eThe E220\u003cem\u003eevolution\u003c\/em\u003e enables multi-sample, batch preparation, capable of processing a wide range of sample types and volumes and may be programed to process from 1 to 8 samples in a single batch. When workload increases, the E220\u003cem\u003eevolution\u003c\/em\u003e can be upgraded to an E220 capable of processing 1-96 samples\/run or to an LE220 for high-throughput processing without purchasing a new instrument.\u003c\/p\u003e\u003ch2\u003eFeatures\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eIsothermal processing\u003c\/li\u003e\n\u003cli\u003eNon-contact, closed vessel\u003c\/li\u003e\n\u003cli\u003ePrecisely controlled and adjustable energy delivery\u003c\/li\u003e\n\u003cli\u003eAutomation ready\u003c\/li\u003e\n\u003cli\u003eMulti-sample capability\u003c\/li\u003e\n\u003cli\u003eBroad sample volume range\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBenefits\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNo heat damage, higher recovery\u003c\/li\u003e\n\u003cli\u003eNo cross contamination, no aerosols, no clean up\u003c\/li\u003e\n\u003cli\u003eStandardized processes, highly reproducible\u003c\/li\u003e\n\u003cli\u003eIntegrates into customers’ sample processing workflow\u003c\/li\u003e\n\u003cli\u003eHigher productivity, less operator intervention\u003c\/li\u003e\n\u003cli\u003eOne instrument for multiple applications\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePrimary Applications\u003c\/th\u003e\n\u003ctd\u003eCell lysis: mammalian, bacterial, yeast, cfDNA Extraction from Plasma, DNA Extraction from Dried Blood Spots, DNA\/RNA\/Chromatin Shearing, DNA\/RNA\/Total NA\/Protein Extraction from FFPE, Tissue lysis and extraction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTreatment Power\u003c\/th\u003e\n\u003ctd\u003e100 W Avg. Incident Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Requirements\u003c\/th\u003e\n\u003ctd\u003eE100-120, 200-240 V~ 50-60Hz, 500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Environment\u003c\/th\u003e\n\u003ctd\u003eAmbient Environment: 15°C to 30°C (59°F to 86°F), Up to 80%, non-condensing, up to 3000M, pollution degree II, Overvoltage Category 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd\u003e0.5 °C to 55.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSafety\u003c\/th\u003e\n\u003ctd\u003eComplies with Low Voltage Directive 2006\/95\/EC. Certified to IEC\/EN\/UL 61010-1:2004 “Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use, Part1: General Requ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRegulatory Labeling\u003c\/th\u003e\n\u003ctd\u003eCE and ETL Mark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSonoLab Version\u003c\/th\u003e\n\u003ctd\u003eSonoLab 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating System\u003c\/th\u003e\n\u003ctd\u003eWindows 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWCS\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eChiller\u003c\/th\u003e\n\u003ctd\u003eChiller\/heater re-circulating system-Not included, sold separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSample Processing Capacity\u003c\/th\u003e\n\u003ctd\u003eSingle Tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNGS Sample Volumes\u003c\/th\u003e\n\u003ctd\u003e15 to 130 µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCovaris Consumables\u003c\/th\u003e\n\u003ctd\u003emicroTUBE 8-strip (rack required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e500429\u003c\/td\u003e\n\u003ctd\u003eE220 evolution Focused-ultrasonicator\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.covaris.com\/wp-content\/uploads\/resources_pdf\/M020012RevB_DataSheet_Eseries.pdf\" target=\"_blank\"\u003eE220 \/ E220x (E-Series) High Performance Multi-Sample Preparation System\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.covaris.com\/wp-content\/uploads\/resources_pdf\/pn_010264-1.pdf\" target=\"_blank\"\u003eE220 evolution User Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Covaris","offers":[{"title":"Default Title","offer_id":68354900721743,"sku":"500429","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/covaris-500429_3.png?v=1795696390","url":"https:\/\/www.danyel.co.il\/products\/e220-evolution-focused-ultrasonicator-500429","provider":"danyel biotech","version":"1.0","type":"link"}