{"product_id":"cytoview-mea-6-plate-m384-tmea-6b","title":"CytoView MEA 6 Plate","description":"\u003cp\u003e\u003cstrong\u003eCytoView MEA 6 Plate\u003c\/strong\u003e — CytoView MEA 6-Black plate, 64 microelectrodes per well, black polystyrene walls with a transparent SU-8 bottom, case of 5 plates\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrdering options:\u003c\/strong\u003e Black — M384-tMEA-6B · White — M384-tMEA-6W\u003c\/p\u003e\n\u003cdiv class=\"overview\"\u003e\n\n\u003cdiv\u003e\n\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cspan\u003epremium\u003c\/span\u003e Maestro MEA plate with a transparent well bottom\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eCell \u003cspan\u003evisualization\u003c\/span\u003e and assay multiplexing\u003c\/p\u003e\n\u003cp\u003eThe innovative, transparent plate bottom offers additional assay flexibility including cell visualization and assay multiplexing. Bright field imaging enables confirmation of cell spotting accuracy and correlation of cell culture health and connectivity with MEA results. Multiplex fluorescence- or luminescence-based assays with your MEA study to probe complementary end points. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003cimg alt=\"CytoView MEA plate Neurons on a well\" src=\"https:\/\/www.axionbiosystems.com\/sites\/default\/files\/inline-images\/CytoView%20MEA%20-%20neurons%20over%20electrodes%20V2.jpg\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eHigh quality MEA \u003cspan\u003edata\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eBoth cardiomyocytes and neurons perform well on the CytoView MEA plates, showing excellent coverage across all wells and the high signal-to-noise ratio Axion customers expect.\u003c\/p\u003e\n\u003cp\u003eAssay \u003cspan\u003emultiplexing\u003c\/span\u003e enriches MEA data\u003c\/p\u003e\n\u003cp\u003eWith the transparent CytoView MEA plates, reporter-based (ex. fluorescent or luminescent) assays can be used to complement \u003ca href=\"https:\/\/www.axionbiosystems.com\/about-us\/technology\"\u003eMEA data\u003c\/a\u003e generated from the same well. The combination of electrophysiological data with reporter-based assays can provide supplementary information regarding compound mechanism of action.\u003c\/p\u003e\n\u003cdiv\u003e\u003cdiv\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg alt=\"MEA electrophysiology for neurotoxicity assay\" src=\"https:\/\/www.axionbiosystems.com\/sites\/default\/files\/inline-images\/Cytoview%20MEA_%20data%201v1%20A-01.jpg\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg alt=\"MEA electrophysiology for neurotoxicity assay\" src=\"https:\/\/www.axionbiosystems.com\/sites\/default\/files\/inline-images\/Cytoview%20MEA_%20data%201v1%20B-02.jpg\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eIn this neurotoxicity assay, compound were assessed using MEA electrophysiology data from Axion’s Maestro MEA system multiplexed with a fluorescence lactate dehydrogenase (LDH) cell viability assay. Multiplexing enabled greater specificity for compound classification compared to MEA data alone. (A) Both deltamethrin and tributyltin reduced mean firing rate, but (B) only tributyltin reduced cell viability. (Data provided by external customer)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"12\"\u003e\n\u003cp\u003eCytoView MEA\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eThe CytoView MEA plates combine robust data collection with a transparent well bottom for cell visualization and assay multiplexing\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePlate\u003c\/th\u003e\n\u003ctd\u003eCat No.\u003c\/td\u003e\n\u003ctd\u003eWells\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eElectrode\/\u003cbr\u003ewell\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eElectrode\u003cbr\u003elayout*\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eBottom\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eWalls\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eMaestro\u003cbr\u003eVolt\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eMaestro\u003cbr\u003eEdge\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eMaestro\u003cbr\u003ePro\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eMaestro\u003cbr\u003eZ\/ZHT\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eMaestro\u003cbr\u003eOriginal\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCytoView MEA 6\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e(a) M384-tMEA-6B\u003cbr\u003e(b) M384-tMEA-6W\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e6\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e64\u003cbr\u003ePEDOT\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cimg alt=\"cytoview MEA plate 6well plate bottom M384-tMEA-6\" src=\"https:\/\/www.axionbiosystems.com\/sites\/default\/files\/inline-images\/cytoview_mea_6_65.png\"\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eTransparent\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e(a) Black\u003cbr\u003e(b) White\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e●\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e●\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e●\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e●\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCytoView MEA 12\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eM768-tMEA-12W\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e12\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e64\u003cbr\u003ePEDOT\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cimg alt=\"cytoview MEA plate 6well plate bottom M384-tMEA-6\" src=\"https:\/\/www.axionbiosystems.com\/sites\/default\/files\/inline-images\/cytoview_mea_6_65.png\"\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eTransparent\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eWhite\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e●\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCytoView MEA 24\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eM384-tMEA-24W \u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e24\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e16\u003cbr\u003ePEDOT\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cimg alt=\"Cytoview MEA plate 24 well plate bottom electrode layout\" src=\"https:\/\/www.axionbiosystems.com\/sites\/default\/files\/inline-images\/cytoview_mea_24_65.png\"\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eTransparent\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eWhite\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e●\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e●\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCytoView MEA 48\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e(a) M768-tMEA-48B\u003cbr\u003e(b) M768-tMEA-48W\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e48\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e16\u003cbr\u003ePEDOT\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cimg alt=\"MEA plate electrode layout cytoview 48 well\" src=\"https:\/\/www.axionbiosystems.com\/sites\/default\/files\/inline-images\/cytoview_mea_48_65.png\"\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eTransparent\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e(a) Black\u003cbr\u003e(b) White\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e●\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e●\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eCytoView MEA 96\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003e(a) M768-tMEA-96B\u003cbr\u003e(b) M768-tMEA-96W\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e96\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e8\u003cbr\u003ePEDOT\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cimg alt=\"MEA plate electrode layout cytoview 96\" src=\"https:\/\/www.axionbiosystems.com\/sites\/default\/files\/inline-images\/cytoview_mea_96_65.png\"\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eTransparent\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e(a) Black\u003cbr\u003e(b) White\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e●\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e●\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.axionbiosystems.com\/sites\/default\/files\/resources\/M384-tMEA-6%20DATASHEET%20v4.pdf\"\u003eCytoView MEA 6 - Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.axionbiosystems.com\/sites\/default\/files\/resources\/MEA%20plates-brochure-Rev15.pdf\"\u003eMEA Plates Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Axion BioSystems","offers":[{"title":"Black","offer_id":46498002141263,"sku":"M384-tMEA-6B","price":8519.0,"currency_code":"ILS","in_stock":true},{"title":"White","offer_id":46498002174031,"sku":"M384-tMEA-6W","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/ProductPage_CytoviewWell_550x550_2.jpg?v=1787769794","url":"https:\/\/www.danyel.co.il\/products\/cytoview-mea-6-plate-m384-tmea-6b","provider":"danyel biotech","version":"1.0","type":"link"}