{"product_id":"cooling-thermal-shake-touch-thermo-shakers-460-0198","title":"Cooling Thermal Shake Touch, Thermo Shakers","description":"\u003cp\u003eThe cooling thermal shake touch is designed for applications that require consistent, precise results. With heating, cooling and shaking capabilities, this low profile unit uses interchangeable blocks to accommodate a wide variety of tubes and microplates. The LCD touch screen enables faster setting of temperature, speed and time, which can all be viewed at once. Display features on-screen help topics with operational tips. Touch screen is compatible with rubber gloves used in laboratories.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eEasy to use 4,3\" colour LCD touch screen allows the user to save and visibly track progress through the live status bar for five user-defined programs, each with five individual steps\u003c\/li\u003e\n\u003cli\u003eSuitable for rapid heating, cooling and high speed shaking and a pulse mode feature, ideal for quick vortex applications\u003c\/li\u003e\n\u003cli\u003eTimer with audible alarm, 1 minute to 99 hours, 59 minutes, heat function will automatically shut off if the unit recognises an internal issue\u003c\/li\u003e\n\u003cli\u003eUSB port can transfer information to a flash drive for data logging, program storage and software updates\u003c\/li\u003e\n\u003cli\u003eManufacturer warranty up to 5 years\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eProgram control capabilities allow user-programmable operation for automated use and memory for five separate, five-step programs. Adjustable temperature ramp rate feature separately defines the heating and cooling rates in increments of 0,5 °C\/min. Single-point calibration mode for maximum temperature accuracy, the single-point calibration procedure allows the user to calibrate up to six different defined temperatures. Constructed from a high quality heat and chemical resistant polymer, so the housing remains cool to the touch throughout normal operating temperatures. Maximum temperature-limiting function ensures the temperature will not exceed user-defined limits, allowing control of temperature-sensitive samples. A hot top warning illuminates when the temperature reaches 40 °C, and remains on until the unit is cooled below 40 °C.\u003c\/p\u003e\u003cp\u003eThe unit's enhanced electronics and dual-temperature sensors provide accurate, dependable temperature settings across the operating range of 5 to 35 °C, (maximum 80% relative humidity, non condensing). Applications include cell cultures, DNA, RNA, hybridisation and protein studies.\u003c\/p\u003e\u003cp\u003eSupplied without blocks, blocks must be ordered separately. Note that Eppendorf Thermomixer R® blocks are compatible with the VWR® Cooling thermal shake touch. Model with NIST traceable certificate is also available, this includes a 3-point NIST traceable calibration. The traceable certificate includes actual calibration measurement data and uncertainty. The calibration laboratory is ISO\/IEC 17025 compliant.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e ** Microtube blocks include a removable rack and cover.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e Cooling Thermal Shake Touch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature control range:\u003c\/strong\u003e From 13 below ambient to 100 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature accuracy:\u003c\/strong\u003e ±0,5 °C (20...45 °C) ±2 °C ( 45 °C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed range:\u003c\/strong\u003e 300 - 3000 min⁻¹\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed accuracy:\u003c\/strong\u003e ±2 %\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling rate:\u003c\/strong\u003e Above ambient: 2 - 3 °C\/min Below ambient: 0,5 - 1,0 °C\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating speed:\u003c\/strong\u003e 5 °C\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4,4 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eW×D×H:\u003c\/strong\u003e 248×260×132 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrbit:\u003c\/strong\u003e 3 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.avantorsciences.com\/adaptivemedia\/rendition\/id_0e05305b802d6202fe88ff2e5232537ad87013f1\/vid_0e05305b802d6202fe88ff2e5232537ad87013f1\/prid_original\/clid_SAPDAM\" target=\"_blank\" rel=\"noopener\"\u003eManual VWR Thermal Shake Touch and Cooling Thermal Shake Touch\u003c\/a\u003e (Manual)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.avantorsciences.com\/adaptivemedia\/rendition\/id_1389886413b7c98cedd7148ca674e08d0bae9af3\/vid_64d6dfb009388d67d54dd0d8c56e14a58b508589\/prid_original\/clid_SAPDAM\" target=\"_blank\" rel=\"noopener\"\u003eManual 715094-00 VWR Europe Thermal Shake Touch Rev120130523 100613\u003c\/a\u003e (Manual)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.avantorsciences.com\/adaptivemedia\/rendition\/id_c084ae9895c4d331e5f69afed71147a38768d025\/vid_e9838e83afec3ce29fadb53aaa0c8633096a0344\/prid_original\/clid_SAPDAM\" target=\"_blank\" rel=\"noopener\"\u003eManual VWR Thermal Shake Touch\u003c\/a\u003e (Manual)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.avantorsciences.com\/adaptivemedia\/rendition\/id_5e69b56e241207f3966b42ae6345de5ff7501a88\/vid_5e69b56e241207f3966b42ae6345de5ff7501a88\/prid_original\/clid_SAPDAM\" target=\"_blank\" rel=\"noopener\"\u003eAvantor VWR Laboratory Equipments\u003c\/a\u003e (Brochure)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.avantorsciences.com\/adaptivemedia\/rendition\/id_5a55a17dd7f1dfda15b1687a8940144cf510cd94\/vid_51785610f1cac66fad0febbbea3173c1b078d3ee\/prid_original\/clid_SAPDAM\" target=\"_blank\" rel=\"noopener\"\u003eAvantor VWR®PCR Solutions\u003c\/a\u003e (Brochure)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/media.vwr.com\/ecatalog\/index.html\/catalog_EU_AIO_Baths_2017\/EN\/shop_uk\" target=\"_blank\" rel=\"noopener\"\u003eVWR® for baths, thermostats and circulators\u003c\/a\u003e (Brochure)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/media.vwr.com\/ecatalog\/index.html\/catalog_EU_HSG_Stirring_Shaking_2018\/EN\/shop_uk\" target=\"_blank\" rel=\"noopener\"\u003eVWR® for Stirring, Mixing, Shaking And Blending\u003c\/a\u003e (Brochure)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003ePack\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e460-0198\u003c\/td\u003e\n\u003ctd\u003eCooling Thermal Shake Touch\u003c\/td\u003e\n\u003ctd\u003eCooling thermal shake touch, UK-plug\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e460-0199\u003c\/td\u003e\n\u003ctd\u003eCooling Thermal Shake Touch (460-0199)\u003c\/td\u003e\n\u003ctd\u003eCooling thermal shake touch, UK-plug, NIST certificate\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"VWR","offers":[{"title":"Cooling Thermal Shake Touch","offer_id":46772340359247,"sku":"460-0198","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Cooling Thermal Shake Touch (460-0199)","offer_id":46772340392015,"sku":"460-0199","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/clid_SAPDAM_45ccde5a-66ae-414a-bdeb-f01385c2029b.jpg?v=1789394177","url":"https:\/\/www.danyel.co.il\/products\/cooling-thermal-shake-touch-thermo-shakers-460-0198","provider":"danyel biotech","version":"1.0","type":"link"}