{"product_id":"biocircuit-mea-96-plate-m768-bio-96","title":"BioCircuit MEA 96 Plate","description":"\u003cp\u003e\u003cstrong\u003eBioCircuit MEA 96 Plate\u003c\/strong\u003e — BioCircuit MEA 96 plate, 8 microelectrodes per well, clear polystyrene walls with an opaque bottom, includes on-plate spotting guides, box of 5 plates\u003c\/p\u003e\n\u003cdiv class=\"overview\"\u003e\n\n\u003cdiv\u003e\n\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eMEA plates with an opaque well bottom delivering \u003cspan\u003ehigh-quality\u003c\/span\u003e results\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eSuperior\u003c\/span\u003e droplet placement\u003c\/p\u003e\n\u003cp\u003eBioCircuit MEA plates have on-plate spotting guides in the bottom of each well that confine the cell droplet over the recording electrodes. This enables more precise cell plating with less effort. Simply position the pipette between the AccuSpot™ features and release the droplet to ensure a perfectly centered, rounded droplet in every well. Plating cells in a small droplet centered over the electrode array will conserve cells and ensure robust electrical activity near the electrodes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\u003ccenter\u003e\u003cimg alt=\"BioCircuit multiwell MEA plate Droplet Placement\" src=\"https:\/\/www.axionbiosystems.com\/sites\/default\/files\/inline-images\/Biocircuit-droplets-DSC02577.jpg\"\u003e\u003c\/center\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eHigh quality MEA \u003cspan\u003edata\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eAll excitable cell types perform well on the BioCircuit MEA plates, showing excellent coverage across all wells and the high signal-to-noise ratio. Track the development of electrical activity in stem cell-derived neurons or cardiomyocytes, study disease models, or examine the effects of compound treatment on excitable cells – the possibilities are endless with BioCircuit MEA plates.\u003c\/p\u003e\n\u003cp\u003eEnhance \u003cspan\u003eyour assay\u003c\/span\u003e with LEAP\u003c\/p\u003e\n\u003cp\u003eTo complement high-quality field potential signals recorded using BioCircuit MEA plates, Axion’s innovative Local Extracellular Action Potential (LEAP) assay allows you to record extracellular action potential waveforms from cardiomyocytes. LEAP signals enable quantification of action potential morphology and characterization of complex repolarization irregularities such as early after depolarizations (EADs).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\u003cth colspan=\"12\"\u003e\n\u003cp\u003eBioCircuit MEA\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eThe BioCircuit MEA plates deliver high-quality results together with industry leading throughput at the lowest cost per well\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/th\u003e\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePlate\u003c\/th\u003e\n\u003ctd\u003eCat No.\u003c\/td\u003e\n\u003ctd\u003eWells\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eElectrode\/\u003cbr\u003ewell\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eElectrode\u003cbr\u003elayout*\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eBottom\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eWalls\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eMaestro\u003cbr\u003eVolt\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eMaestro\u003cbr\u003eEdge\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eMaestro\u003cbr\u003ePro\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eMaestro\u003cbr\u003eZ\/ZHT\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eMaestro\u003cbr\u003eOriginal\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBioCircuit MEA 24\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eM384-BIO-24\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e24\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e16 Gold\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cimg alt=\"biocircuit MEA plate 24 well plate bottom\" src=\"https:\/\/www.axionbiosystems.com\/sites\/default\/files\/inline-images\/biocircuit_wellbottom_24.png\"\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eOpaque\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eClear\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e●\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e●\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBioCircuit MEA 48\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eM768-BIO-48\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e48\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e16 Gold\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cimg alt=\"BioCircuit MEA plate 48 well plate bottom electrode layout\" src=\"https:\/\/www.axionbiosystems.com\/sites\/default\/files\/inline-images\/biocircuit_wellbottom_24_0.png\"\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eOpaque\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eClear\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e ●\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e●\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBioCircuit MEA 96\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd\u003eM768-BIO-96\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e96\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e8 Gold\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cimg alt=\"MEA plate electrode layout biocircuit 96 well\" src=\"https:\/\/www.axionbiosystems.com\/sites\/default\/files\/inline-images\/biocircuit_wellbottom_96.png\"\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eOpaque\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003eClear\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ccenter\u003e\u003cp\u003e ●\u003c\/p\u003e\u003c\/center\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e●\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.axionbiosystems.com\/sites\/default\/files\/resources\/M768-BIO-96%20DATASHEET%20v4.pdf\"\u003eBioCircuit MEA 96 - Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.axionbiosystems.com\/sites\/default\/files\/resources\/MEA%20plates-brochure-Rev15.pdf\"\u003eMEA Plates Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Axion BioSystems","offers":[{"title":"Default Title","offer_id":46498002239567,"sku":"M768-BIO-96","price":9648.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/ProductPage_BioCircuitWell_550x550_2.jpg?v=1787769802","url":"https:\/\/www.danyel.co.il\/products\/biocircuit-mea-96-plate-m768-bio-96","provider":"danyel biotech","version":"1.0","type":"link"}