{"product_id":"biochrom-bio-32-plus-amino-acid-analyzer-systems","title":"Biochrom Bio 32+ Oxidized Protein Hydrolysate Amino Acid Analyzer Systems","description":"\u003cp\u003eIn the competitive food industry, dieticians rely on dedicated amino acid analysis for precise protein measurement, crucial for ensuring food quality and serving as a valuable sales aid. This analysis is integral for producers to monitor quality from raw materials through final product processing.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eA Dedicated Amino Acid Analysis System\u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccurate: \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eSuperb separation, accurately identifies and quantifies free amino acids, as well as the amino acid composition of proteins and peptides.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReliable: \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMinimal matrix interference and near baseline separation. Automated derivatization of amino acids maximizes reproducibility.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast: \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eRapid protocols that increase sample throughput by cutting analysis time.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEconomical: \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eThe column cleaning and repacking service, gives columns an almost indefinite life and cuts the cost of ownership.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFully Automated: \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eTotal PC control allows 24\/7 operations.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersatile:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eWide variety of sample types compatible: Protein hydrolysates from various food and feedstuff samples or synthetic drugs, nutraceuticals, beverages.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEasy to implement: \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNo lengthy method development required as this well characterized system is established worldwide. All customers have their instrument optimized to their application directly from the factory.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConvenient: \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eInterchangeable sample trays allow samples to be prepared in advance and stored refrigerated.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRobust:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAdvanced fluidics and robust hardware mean easy maintenance for users, backed by the reassurance of Biochrom's dedicated service and support team.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlexible:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eIntegrated software, choice of different methods to adapt to the user's needs. Automatic sample set-up. Networking and exporting of data.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompact:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eBench top design requiring minimum lab space.\u003c\/td\u003e \u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eInstrument Typical Package\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eThe Instrument package consists of the Analyzer (electronics unit, pumps, and detection system) plus:\u003c\/p\u003e \u003cul\u003e\n\u003cli\u003eCooled or Non-Cooled Autosampler\u003c\/li\u003e \u003cli\u003eColumn kit: analytical column and top-up ion exchange resin, prewash column and top-up ion exchange resin\u003c\/li\u003e \u003cli\u003eNinhydrin\u003c\/li\u003e \u003cli\u003eBuffer Chemical Kit suitable for up to 170 analyses\u003c\/li\u003e \u003cli\u003eSpare parts and Consumables Kit\u003c\/li\u003e \u003cli\u003eCalibration Standard\u003c\/li\u003e \u003cli\u003eHardware control and data handling software\u003c\/li\u003e \u003cli\u003eDesktop PC, LED widescreen monitor\u003c\/li\u003e \u003cli\u003eUser Manual (PDF format)\u003c\/li\u003e \u003cli\u003ePower cables\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eFor buffer and chemicals information, consult the Consumables tab below.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReproducibility:\u003c\/strong\u003e Area: \u0026lt; 1.5% RSD at 10 nanomoles Retention time: \u0026lt; 0.5 %RSD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePumps:\u003c\/strong\u003e Two dual piston pumps with integrated pressure transducer and drain valve Ceramic pump head, sapphire pistons and valves Electronically controlled piston wash\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Pressures:\u003c\/strong\u003e Buffer pressure: maximum 150 bar Ninhydrin pressure: maximum 24 bar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalytical Column:\u003c\/strong\u003e High pressure PEEK column packed with Ultropac 8 cation exchange resin. Peltier heating\/cooling system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Injection:\u003c\/strong\u003e 3 injection modes (full loop, partial loop and micro), 84 position autosampler Sample volumes from 1 µL to 5000 µL (200 µL loop supplied as standard)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperatures:\u003c\/strong\u003e Column temperature variable between 20°C and 99°C Reaction coil temperature adjustable between 40°C and 145°C (135°C is optimum)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware:\u003c\/strong\u003e Phoenix Integrated Control Software Agilent OpenLAB CDS EZChrom Edition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometer:\u003c\/strong\u003e Single flow cell with optical beam splitter with detection at 440 nm and 570 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight and Dimensions:\u003c\/strong\u003e Main System: 50 kg (110 lb.) 48 x 59 x 57 cm (19 x 23 x 22 in.) Autosampler: 21kg (46 lb.) 30 x 57.5 x 36 cm (12 x 23 x 14 in.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired Services:\u003c\/strong\u003e Oxygen free nitrogen gas (99.99%) or argon gas regulated to 5 bar Drainage facility 240V\/100V, 50Hz\/60Hz, 300VA mains supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Systems:\u003c\/strong\u003e Automatic shut down and reaction coil flushing in the event of: Power failure Photometer lamp failure Low ninhydrin, low buffer, low coil or low nitrogen pressures High coil or column temperatures, high ninhydrin, high buffer or high coil pressures\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/sites\/default\/files\/2024-08\/Biochrom-Phoenix-Brochure.pdf\"\u003eBio 30+ Series Amino Acid Analyzer System Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/sites\/default\/files\/2026-08\/26_Biochrom_AAA_Brochure_Phoenix-compressed.pdf\"\u003eBiochrom Phoenix Software Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/biochrom\/material-safety-data-sheet-msds\"\u003eMaterial Safety Data Sheet (MSDS)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/biochrom\/certificates-of-analysis\"\u003eCertificates of Analysis\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/sites\/default\/files\/2026-07\/Biochrom%20Amino%20Acid%20Analysis%20Ordering%20Guide%20NC_July%202026.pdf\"\u003eOrdering Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCatalogue No.\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-6000-79\u003c\/td\u003e\n\u003ctd\u003eAccelerated Buffers, Cooled Autosampler\u003c\/td\u003e\n\u003ctd\u003eBIO32+ ACCELERATED BUFFERS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-6000-80\u003c\/td\u003e\n\u003ctd\u003eAccelerated Buffers, without Autosampler\u003c\/td\u003e\n\u003ctd\u003eBIO32+ ACCELERATED BUFF NO A\/S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-6000-81\u003c\/td\u003e\n\u003ctd\u003eAccelerated, Autosampler (no cooling)\u003c\/td\u003e\n\u003ctd\u003eBIO32+ ACCELERATED NO COOL A\/S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-6004-60\u003c\/td\u003e\n\u003ctd\u003eSodium Oxidized High Performance, Autosampler (no cooling), Phoenix\u003c\/td\u003e\n\u003ctd\u003eBIO32+ NA OXHP NCOOL A\/S PHNX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-6004-61\u003c\/td\u003e\n\u003ctd\u003eSodium Oxidized High Resolution, Autosampler (no cooling), Phoenix\u003c\/td\u003e\n\u003ctd\u003eBIO32+ NA OXHR NCOOL A\/S PHNX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-6004-62\u003c\/td\u003e\n\u003ctd\u003eSodium Accelerated, Autosampler (no cooling), Phoenix\u003c\/td\u003e\n\u003ctd\u003eBIO32+ NA ACC NONCOOL A\/S PHX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-6004-66\u003c\/td\u003e\n\u003ctd\u003eSodium Oxidized High Performance, Cooled Autosampler, Phoenix\u003c\/td\u003e\n\u003ctd\u003eBIO32+ NA OXHP COOL A\/S PHNX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-6004-67\u003c\/td\u003e\n\u003ctd\u003eSodium Oxidized High Resolution, Cooled Autosampler, Phoenix\u003c\/td\u003e\n\u003ctd\u003eBIO32+ NA OXHR COOL A\/S PHNX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-6004-68\u003c\/td\u003e\n\u003ctd\u003eSodium Accelerated, Cooled Autosampler, Phoenix\u003c\/td\u003e\n\u003ctd\u003eBIO32+ NA ACC COOL A\/S PHOENIX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Biochrom","offers":[{"title":"Accelerated Buffers, Cooled Autosampler","offer_id":46498036187215,"sku":"80-6000-79","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Accelerated Buffers, without Autosampler","offer_id":46498036219983,"sku":"80-6000-80","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Accelerated, Autosampler (no cooling)","offer_id":46498036252751,"sku":"80-6000-81","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Sodium Oxidized High Performance, Autosampler (no cooling), Phoenix","offer_id":46498036285519,"sku":"80-6004-60","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Sodium Oxidized High Resolution, Autosampler (no cooling), Phoenix","offer_id":46498036318287,"sku":"80-6004-61","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Sodium Accelerated, Autosampler (no cooling), Phoenix","offer_id":46498036351055,"sku":"80-6004-62","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Sodium Oxidized High Performance, Cooled Autosampler, Phoenix","offer_id":46498036383823,"sku":"80-6004-66","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Sodium Oxidized High Resolution, Cooled Autosampler, Phoenix","offer_id":46498036416591,"sku":"80-6004-67","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Sodium Accelerated, Cooled Autosampler, Phoenix","offer_id":46498036449359,"sku":"80-6004-68","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/aaa-30_-amino-acid-analyzer-biochrom.jpg?v=1787771307","url":"https:\/\/www.danyel.co.il\/products\/biochrom-bio-32-plus-amino-acid-analyzer-systems","provider":"danyel biotech","version":"1.0","type":"link"}