{"product_id":"biochrom-bio-31-plus-amino-acid-analyzer-systems","title":"Biochrom Bio 31+ Protein Hydrolysate Amino Acid Analyzer Systems","description":"\u003cp\u003eThe Bio 31+ Protein Hydrolysate System, utilizing sodium citrate-based buffers, ensures fully automated, high-standard analysis for generic drugs and infusion fluids. Our dedicated amino acid analyzers accurately quantify amino acids in solutions derived from diverse materials, including proteins, peptides, and pharmaceutical ingredients. This typically involves simple sample preparation methods like acid hydrolysis, eliminating the need for chemical derivatization before injecting the hydrolyzed sample, thanks to automated post-column ninhydrin detection.\u003c\/p\u003e \u003cp\u003eThe long-lasting sodium columns in the Bio 31+ Protein Hydrolysate System tolerate various matrices and high-salt content, making it effective for analyzing infusion liquids, recombinant peptides, and synthetic drugs. Its capability to handle complex sample matrices makes it as a robust quality control technique for analyzing vitamins, synthetic drugs, and more.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eA Dedicated Amino Acid Analysis System\u003c\/strong\u003e\u003c\/p\u003e \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccurate: \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eSuperb separation, accurately identifies and quantifies free amino acids, as well as the amino acid composition of proteins and peptides.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReliable: \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eMinimal matrix interference and near baseline separation. Automated derivatization of amino acids maximizes reproducibility.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFast: \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eRapid protocols that increase sample throughput by cutting analysis time.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEconomical: \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eThe column cleaning and repacking service, gives columns an almost indefinite life and cuts the cost of ownership.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFully Automated: \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eTotal PC control allows 24\/7 operations.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVersatile:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eWide variety of sample types compatible: Protein hydrolysates from various food and feedstuff samples or synthetic drugs, nutraceuticals, beverages.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEasy to implement: \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNo lengthy method development required as this well characterized system is established worldwide. All customers have their instrument optimized to their application directly from the factory.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConvenient: \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eInterchangeable sample trays allow samples to be prepared in advance and stored refrigerated.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRobust:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eAdvanced fluidics and robust hardware mean easy maintenance for users, backed by the reassurance of Biochrom's dedicated service and support team.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlexible:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eIntegrated software, choice of different methods to adapt to the user's needs. Automatic sample set-up. Networking and exporting of data.\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompact:\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eBench top design requiring minimum lab space.\u003c\/td\u003e \u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e \u003cp\u003e\u003cstrong\u003eInstrument Typical Package\u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eThe Instrument package consists of the Analyzer (electronics unit, pumps, and detection system) plus:\u003c\/p\u003e \u003cul\u003e\n\u003cli\u003eCooled or Non-Cooled Autosampler\u003c\/li\u003e \u003cli\u003eColumn kit: analytical column and top-up ion exchange resin, prewash column and top-up ion exchange resin\u003c\/li\u003e \u003cli\u003eNinhydrin\u003c\/li\u003e \u003cli\u003eBuffer Chemical Kit suitable for up to 170 analyses\u003c\/li\u003e \u003cli\u003eSpare parts and Consumables Kit\u003c\/li\u003e \u003cli\u003eCalibration Standard\u003c\/li\u003e \u003cli\u003eHardware control and data handling software\u003c\/li\u003e \u003cli\u003eDesktop PC, LED widescreen monitor\u003c\/li\u003e \u003cli\u003eUser Manual (PDF format)\u003c\/li\u003e \u003cli\u003ePower cables\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eFor buffer and chemicals information, consult the Consumables tab below.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReproducibility:\u003c\/strong\u003e Area: \u0026lt;1.5% RSD at 5 nanomoles Retention time: \u0026lt; 0.5% RSD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePumps:\u003c\/strong\u003e Two dual piston pumps with integrated pressure transducer and drain valve Ceramic pump head, sapphire pistons and valves Electronically controlled piston wash\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Pressures:\u003c\/strong\u003e Buffer pressure: maximum 150 bar Ninhydrin pressure: maximum 24 bar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalytical Column:\u003c\/strong\u003e High pressure PEEK column packed with Ultropac 8 cation exchange resin. Peltier heating\/cooling system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Injection:\u003c\/strong\u003e 3 injection modes (full loop, partial loop and micro), 84 position autosampler Sample volumes from 1 µL to 5000 µL (200 µL loop supplied as standard)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperatures:\u003c\/strong\u003e Column temperature variable between 20°C and 99°C. Reaction coil temperature adjustable between 40°C and 145°C (135°C nominal for UltraNynhydrin, 138°C nominal for EzNin)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware:\u003c\/strong\u003e Phoenix Integrated Control Software Agilent OpenLAB CDS EZChrom Edition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometer:\u003c\/strong\u003e Single flow cell with optical beam splitter with detection at 440 nm and 570 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight and Dimensions:\u003c\/strong\u003e Main System: 50 kg (110 lb.) 48 x 59 x 57 cm (19 x 23 x 22 in.) Autosampler: 21kg (46 lb.) 30 x 57.5 x 36 cm (12 x 23 x 14 in.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired Services:\u003c\/strong\u003e Oxygen free nitrogen gas (99.99%) or argon gas regulated to 5 bar Drainage facility 240V\/100V, 50Hz\/60Hz, 300VA mains supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Systems:\u003c\/strong\u003e Automatic shut down and reaction coil flushing in the event of: Power failure Photometer lamp failure Low ninhydrin, low buffer, low coil or low nitrogen pressures High coil or column temperatures, high ninhydrin, high buffer or high coil pressures\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/sites\/default\/files\/2024-08\/Biochrom-Phoenix-Brochure.pdf\"\u003eBio 30+ Series Amino Acid Analyzer System Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/sites\/default\/files\/2026-08\/26_Biochrom_AAA_Brochure_Phoenix-compressed.pdf\"\u003eBiochrom Phoenix Software Brochure\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/biochrom\/material-safety-data-sheet-msds\"\u003eMaterial Safety Data Sheet (MSDS)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/biochrom\/certificates-of-analysis\"\u003eCertificates of Analysis\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/sites\/default\/files\/2026-07\/Biochrom%20Amino%20Acid%20Analysis%20Ordering%20Guide%20NC_July%202026.pdf\"\u003eOrdering Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCatalogue No.\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-6004-58\u003c\/td\u003e\n\u003ctd\u003eSodium High Performance, Autosampler (no cooling), Phoenix\u003c\/td\u003e\n\u003ctd\u003eBIO31+ NA HP NONCOOL A\/S PHNX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-6004-59\u003c\/td\u003e\n\u003ctd\u003eSodium High Resolution, Autosampler (no cooling), Phoenix\u003c\/td\u003e\n\u003ctd\u003eBIO31+ NA HR NONCOOL A\/S PHNX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-6004-63\u003c\/td\u003e\n\u003ctd\u003eSodium Polyamine, Autosampler (no cooling), Phoenix\u003c\/td\u003e\n\u003ctd\u003eBIO31+ NA POLY NONCOOL A\/S PHX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-6004-64\u003c\/td\u003e\n\u003ctd\u003eSodium High Performance, Cooled Autosampler, Phoenix\u003c\/td\u003e\n\u003ctd\u003eBIO31+ NA HP COOL A\/S PHOENIX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-6004-65\u003c\/td\u003e\n\u003ctd\u003eSodium High Resolution, Cooled Autosampler, Phoenix\u003c\/td\u003e\n\u003ctd\u003eBIO31+ NA HR COOL A\/S PHOENIX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-6004-69\u003c\/td\u003e\n\u003ctd\u003eSodium Polyamine, Cooled Autosampler, Phoenix\u003c\/td\u003e\n\u003ctd\u003eBIO31+ NA POLY COOL A\/S PHNX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Biochrom","offers":[{"title":"Sodium High Performance, Autosampler (no cooling), Phoenix","offer_id":46498035597391,"sku":"80-6004-58","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Sodium High Resolution, Autosampler (no cooling), Phoenix","offer_id":46498035630159,"sku":"80-6004-59","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Sodium Polyamine, Autosampler (no cooling), Phoenix","offer_id":46498035662927,"sku":"80-6004-63","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Sodium High Performance, Cooled Autosampler, Phoenix","offer_id":46498035695695,"sku":"80-6004-64","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Sodium High Resolution, Cooled Autosampler, Phoenix","offer_id":46498035728463,"sku":"80-6004-65","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Sodium Polyamine, Cooled Autosampler, Phoenix","offer_id":46498035761231,"sku":"80-6004-69","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/aaa-30_-amino-acid-analyzer-biochrom.jpg?v=1787771307","url":"https:\/\/www.danyel.co.il\/products\/biochrom-bio-31-plus-amino-acid-analyzer-systems","provider":"danyel biotech","version":"1.0","type":"link"}