{"product_id":"5-ul-microliter-autosampler-ctc-s-line-syringe-6","title":"5 µL, Microliter Autosampler CTC S-Line Syringe (6.6 mm)","description":"\u003cp\u003eHamilton's \u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/microliter-syringes\/700-series\"\u003e700 series\u003c\/a\u003e, Microliter #75 Fixed Needle (N) Syringe is designed for use with \u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/syringe-applications\/gc-autosampler-syringes\/ctc-leap-gc-pal-syringes\"\u003eCTC\/LEAP PAL GC autosamplers\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eC-Line syringes incorporate several unique design features that ensure superior performance. The unique flange alignment design aids in installation and results in fewer bent needles while the plunger button can be adjusted to prevent plunger tip damage. An innovative direct attachment design of the needle to the barrel minimizes sample carryover\u003c\/p\u003e\u003cp\u003eHamilton's 700 series \u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\"\u003esyringes\u003c\/a\u003e offer a velvet feel, featuring a stainless-steel plunger crafted to fit the glass barrel with a tolerance of less than three-thousandths of a millimeter. Hamilton's rigorous quality control guarantees the highest standards of accuracy and precision. \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompatible Autosamplers:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/syringe-applications\/gc-autosampler-syringes\/ctc-leap-gc-pal-syringes\/gc-sline-syringes\"\u003eGC S-Line Syringes\u003c\/a\u003e\u003c\/p\u003e \u003cp\u003e Common applications \u003ca href=\"https:\/\/www.hamiltoncompany.com\/applications\/veterinary-sciences\"\u003eVeterinary Sciences\u003c\/a\u003e \u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVolume\u003c\/th\u003e\n\u003ctd\u003e5 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSyringe Type\u003c\/th\u003e\n\u003ctd\u003eMicroliter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSyringe Series\u003c\/th\u003e\n\u003ctd\u003e700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003ctd\u003eCemented Needle (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle\u003c\/th\u003e\n\u003ctd\u003eCemented Needle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGauge\u003c\/th\u003e\n\u003ctd\u003e26s gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoint Style\u003c\/th\u003e\n\u003ctd\u003eAS: Conical, Autosampler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle Length\u003c\/th\u003e\n\u003ctd\u003e1.98 inches (50.3 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePlunger Style\u003c\/th\u003e\n\u003ctd\u003eStandard Plunger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid Path\u003c\/th\u003e\n\u003ctd\u003eSST, borosilicate glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutoclavable\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas Sterilizable\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePressure\u003c\/th\u003e\n\u003ctd\u003e2000 psig (137.9 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e50°C \/ 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e20°C \/ 68°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle Inner Diameter\u003c\/th\u003e\n\u003ctd\u003e0.005 inches (0.13 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle Outer Diameter\u003c\/th\u003e\n\u003ctd\u003e0.019 inches (0.474 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStd Needle Dead Volume\u003c\/th\u003e\n\u003ctd\u003e1.13 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSales Quantity\u003c\/th\u003e\n\u003ctd\u003e1 syringe per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSyringe Model Number\u003c\/th\u003e\n\u003ctd\u003e75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/knowledge-base\/datasheet\/ctc-combi-pal-gc-autosampler-syringe-datasheet\"\u003eCtc Combi Pal Gc Autosampler Syringe Datasheet (Datasheet)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/knowledge-base\/instructions\/instructions-microliter-syringes\"\u003eInstructions Microliter Syringes (Instructions)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/product-specs\/67436-01\"\u003e67436 01 (Specification)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hamilton Company","offers":[{"title":"Default Title","offer_id":46487475814479,"sku":"67436-01","price":398.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/700-Series-SYRINGE-1620X1080_2025-03-24-204934_pfqq.jpg?v=1787653328","url":"https:\/\/www.danyel.co.il\/products\/5-ul-microliter-autosampler-ctc-s-line-syringe-6","provider":"danyel biotech","version":"1.0","type":"link"}