{"product_id":"25-ul-microliter-ctc-s-line-autosampler-syringe-6","title":"25 µL, Microliter CTC S-Line Autosampler Syringe (6.6 mm), Fixed Needle (N)","description":"\u003cp\u003eHamilton's \u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/gastight-syringes\/1700-series\"\u003e1700 series\u003c\/a\u003e, Gastight #1702 Fixed Needle (N) Syringe is designed for use with \u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/syringe-applications\/gc-autosampler-syringes\/ctc-leap-gc-pal-syringes\"\u003eCTC\/LEAP PAL GC autosamplers\u003c\/a\u003e.\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/syringe-applications\/gc-autosampler-syringes\/ctc-leap-gc-pal-syringes\/gc-cline-syringes\"\u003eC-Line syringes\u003c\/a\u003e incorporate several unique design features that ensure superior performance. The unique flange alignment design aids in installation and results in fewer bent needles while the plunger button can be adjusted to prevent plunger tip damage. An innovative direct attachment design of the needle to the barrel minimizes sample carryover\u003cbr\u003e\u003cbr\u003eHamilton 1700 series syringes are Gastight versions of the 700 series, ideal for dispensing liquids and gases. Their polymer plunger tip ensures a leak-free seal. These syringes offer upto 1% accuracy, superior durability, and are made from high-quality, chemically resistant materials.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompatible Autosamplers:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/syringe-applications\/gc-autosampler-syringes\/ctc-leap-gc-pal-syringes\/gc-sline-syringes\"\u003eGC S-Line Syringes\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVolume\u003c\/th\u003e\n\u003ctd\u003e25 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSyringe Type\u003c\/th\u003e\n\u003ctd\u003eGastight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSyringe Series\u003c\/th\u003e\n\u003ctd\u003e1700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003ctd\u003eCemented Needle (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle\u003c\/th\u003e\n\u003ctd\u003eCemented Needle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGauge\u003c\/th\u003e\n\u003ctd\u003e23 gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoint Style\u003c\/th\u003e\n\u003ctd\u003eAS: Conical, Autosampler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle Length\u003c\/th\u003e\n\u003ctd\u003e52 mm (2.04 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePlunger Style\u003c\/th\u003e\n\u003ctd\u003eStandard Plunger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid Path\u003c\/th\u003e\n\u003ctd\u003eSST, borosilicate glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutoclavable\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas Sterilizable\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePressure\u003c\/th\u003e\n\u003ctd\u003e2000 psig (137.9 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e50°C \/ 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e20°C \/ 68°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle Inner Diameter\u003c\/th\u003e\n\u003ctd\u003e0.0128 inches (0.325 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle Outer Diameter\u003c\/th\u003e\n\u003ctd\u003e0.025 inches (0.642 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStd Needle Dead Volume\u003c\/th\u003e\n\u003ctd\u003e4.53 μL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSales Quantity\u003c\/th\u003e\n\u003ctd\u003e1 syringe per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSyringe Model Number\u003c\/th\u003e\n\u003ctd\u003e1702\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/knowledge-base\/catalog\/syringe-and-needle-reference-guide\"\u003eSyringe And Needle Reference Guide (Catalog)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/knowledge-base\/guide\/care-and-use-guide\"\u003eCare And Use Guide (Guide)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/product-specs\/67430-01\"\u003e67430 01 (Specification)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hamilton Company","offers":[{"title":"Default Title","offer_id":46487475650639,"sku":"67430-01","price":429.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/syringe_67430-01.jpg?v=1787653323","url":"https:\/\/www.danyel.co.il\/products\/25-ul-microliter-ctc-s-line-autosampler-syringe-6","provider":"danyel biotech","version":"1.0","type":"link"}