{"product_id":"100-ul-gastight-ctc-c-line-autosampler-syringe-removable","title":"100 µL, Gastight CTC C-Line Autosampler Syringe, Removable Needle (RN)","description":"\u003cp\u003eHamilton's \u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/gastight-syringes\/1700-series\"\u003e1700 series\u003c\/a\u003e, Gastight #1710 Removable Needle (RN) Syringe is designed for use with \u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/syringe-applications\/gc-autosampler-syringes\/ctc-leap-gc-pal-syringes\"\u003eCTC\/LEAP PAL GC autosamplers\u003c\/a\u003e.\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/syringe-applications\/gc-autosampler-syringes\/ctc-leap-gc-pal-syringes\/gc-cline-syringes\"\u003eC-Line syringes\u003c\/a\u003e incorporate several unique design features that ensure superior performance. The unique flange alignment design aids in installation and results in fewer bent needles while the plunger button can be adjusted to prevent plunger tip damage. An innovative direct attachment design of the needle to the barrel minimizes sample carryover\u003cbr\u003e\u003cbr\u003eHamilton 1700 series syringes are Gastight versions of the 700 series, ideal for dispensing liquids and gases. Their polymer plunger tip ensures a leak-free seal. These syringes offer upto 1% accuracy, superior durability, and are made from high-quality, chemically resistant materials.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompatible Autosamplers:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/syringe-applications\/hplc-autosampler-syringes\/agilent-hplc\/agilent-1290-infinity-lc-injector-htc-hts-syringes\"\u003eAgilent 1290 Infinity LC Injector HTC HTS Syringes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/syringe-applications\/hplc-autosampler-syringes\/waters-hplc\/waters-2777-sample-manager\"\u003eWaters 2777 Sample Manager\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/syringe-applications\/hplc-autosampler-syringes\/ctc-leap-pal-hplc\/pal-lc-htc-and-hts-syringes\"\u003ePAL LC HTC and HTS Syringes\u003c\/a\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/syringe-applications\/hplc-autosampler-syringes\/dionex-hplc\/ultimate-3000-syringes\"\u003eUltiMate 3000 Syringes\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVolume\u003c\/th\u003e\n\u003ctd\u003e100 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSyringe Type\u003c\/th\u003e\n\u003ctd\u003eGastight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSyringe Series\u003c\/th\u003e\n\u003ctd\u003e1700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003ctd\u003eRemovable Needle (RN)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle\u003c\/th\u003e\n\u003ctd\u003eSmall RN (CTC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGauge\u003c\/th\u003e\n\u003ctd\u003eNo Needle Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoint Style\u003c\/th\u003e\n\u003ctd\u003eNo Needle Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle Length\u003c\/th\u003e\n\u003ctd\u003eNo Needle Included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePlunger Style\u003c\/th\u003e\n\u003ctd\u003eStandard Plunger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCTC Syringe Type\u003c\/th\u003e\n\u003ctd\u003eC-Line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid Path\u003c\/th\u003e\n\u003ctd\u003eSST, Borosilicate glass, PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutoclavable\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas Sterilizable\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePressure\u003c\/th\u003e\n\u003ctd\u003e1000 psig (68.9 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e50°C \/ 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e20°C \/ 68°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStd Needle Dead Volume\u003c\/th\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSales Quantity\u003c\/th\u003e\n\u003ctd\u003e1 syringe per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSyringe Model Number\u003c\/th\u003e\n\u003ctd\u003e1710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/knowledge-base\/catalog\/syringe-and-needle-reference-guide\"\u003eSyringe And Needle Reference Guide (Catalog)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/knowledge-base\/guide\/care-and-use-guide\"\u003eCare And Use Guide (Guide)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/product-specs\/202668\"\u003e202668 (Specification)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hamilton Company","offers":[{"title":"Default Title","offer_id":46487013294159,"sku":"202668","price":550.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/202668.jpg?v=1787649979","url":"https:\/\/www.danyel.co.il\/products\/100-ul-gastight-ctc-c-line-autosampler-syringe-removable","provider":"danyel biotech","version":"1.0","type":"link"}