{"product_id":"10-ul-microliter-autosampler-ctc-s-line-6-6-2","title":"10 µL, Microliter Autosampler CTC S-Line (6.6 mm) Syringe","description":"\u003cp\u003eHamilton's \u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/microliter-syringes\/700-series\"\u003e700 series\u003c\/a\u003e, Microliter #701 Cemented Needle Syringe, is designed for use with \u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/syringe-applications\/gc-autosampler-syringes\"\u003eCTC\/LEAP PAL GC autosamplers\u003c\/a\u003e. The S-Line Syringes are designed for fast injection speeds in \u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/syringe-applications\/gc-autosampler-syringes\"\u003eGC Chromatography\u003c\/a\u003e. The precise fitting process of our syringes ensures minimal drag force and superior durability.\u003c\/p\u003e\u003cp\u003eHamilton's 700 series syringes offer a velvet feel, featuring a stainless-steel plunger crafted to fit the glass barrel with a tolerance of less than three-thousandths of a millimeter. Hamilton's rigorous quality control guarantees the highest standards of accuracy and precision.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompatible Autosamplers:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/syringe-applications\/gc-autosampler-syringes\/ctc-leap-gc-pal-syringes\/gc-sline-syringes\"\u003eGC S-Line Syringes\u003c\/a\u003e\u003c\/p\u003e \u003cp\u003e Common applications \u003ca href=\"https:\/\/www.hamiltoncompany.com\/applications\/veterinary-sciences\"\u003eVeterinary Sciences\u003c\/a\u003e \u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVolume\u003c\/th\u003e\n\u003ctd\u003e10 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSyringe Type\u003c\/th\u003e\n\u003ctd\u003eMicroliter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSyringe Series\u003c\/th\u003e\n\u003ctd\u003e700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003ctd\u003eCemented Needle (N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle\u003c\/th\u003e\n\u003ctd\u003eCemented Needle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGauge\u003c\/th\u003e\n\u003ctd\u003e23s gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoint Style\u003c\/th\u003e\n\u003ctd\u003eAS: Conical, Autosampler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle Length\u003c\/th\u003e\n\u003ctd\u003e2.00 inches (50.8 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePlunger Style\u003c\/th\u003e\n\u003ctd\u003eStandard Plunger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid Path\u003c\/th\u003e\n\u003ctd\u003eSST, borosilicate glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutoclavable\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas Sterilizable\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePressure\u003c\/th\u003e\n\u003ctd\u003e2000 psig (137.9 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e50°C \/ 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e20°C \/ 68°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle Inner Diameter\u003c\/th\u003e\n\u003ctd\u003e0.0045 inches (0.11 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle Outer Diameter\u003c\/th\u003e\n\u003ctd\u003e0.025 inches (0.64 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStd Needle Dead Volume\u003c\/th\u003e\n\u003ctd\u003e0.54 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSales Quantity\u003c\/th\u003e\n\u003ctd\u003e1 syringe per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/knowledge-base\/instructions\/instructions-syringe-calibration\"\u003eInstructions Syringe Calibration (Instructions)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/knowledge-base\/datasheet\/ctc-combi-pal-gc-autosampler-syringe-datasheet\"\u003eCtc Combi Pal Gc Autosampler Syringe Datasheet (Datasheet)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/product-specs\/67440-01\"\u003e67440 01 (Specification)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hamilton Company","offers":[{"title":"Default Title","offer_id":46487475880015,"sku":"67440-01","price":303.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/700-Series-SYRINGE-1620X1080_2025-03-24-184144_vpen.jpg?v=1787653330","url":"https:\/\/www.danyel.co.il\/products\/10-ul-microliter-autosampler-ctc-s-line-6-6-2","provider":"danyel biotech","version":"1.0","type":"link"}