{"product_id":"1-ul-microliter-syringe-with-guide-knurled-hub-2","title":"1 µL, Microliter Syringe with Guide, Knurled Hub (KH)","description":"\u003cp\u003eHamilton's \u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/microliter-syringes\/7000-series\"\u003e7000 series\u003c\/a\u003e, Microliter #7101 Knurled Hub (KH) Syringe, 22 gauge, point style 3, is designed for manual dispensing and use in autosamplers. The built-in \u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\/syringe-accessories\/plunger-support-accessories\/built-in-chaney-adapter\"\u003eChaney adapter\u003c\/a\u003e comes with this syringe installed from the factory. This eliminates the assembly step which can lead to damage of the smaller volume syringes.\u003c\/p\u003e\u003cp\u003eThe 7000 series syringe offers unmatched accuracy – it's the only true zero-dead volume syringe on the market. Our innovative plunger-in-needle design, featuring a fine-gauge tungsten plunger wire extending to the very tip of the needle, guarantees complete solvent delivery, eliminating waste and maximizing the value of your precious samples. \u003cstrong\u003eDue to this plunger-in-needle design, it is not recommended to remove the needle or plunger.\u003c\/strong\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/syringes\"\u003e Hamilton syringes\u003c\/a\u003e ensure an accuracy of ± 1%, superior durability, and are manufactured with the highest quality chemically resistant materials.\u003c\/p\u003e\u003cp\u003ePlease see the \u003ca href=\"https:\/\/www.hamiltoncompany.com\/knowledge-base\/article\/7000-syringe-series-operating-parameters\"\u003e\u003cstrong\u003e7000 Syringe Series Operating Parameters\u003c\/strong\u003e\u003c\/a\u003e for complete specifications.\u003c\/p\u003e \u003cp\u003e Common applications \u003ca href=\"https:\/\/www.hamiltoncompany.com\/applications\/veterinary-sciences\"\u003eVeterinary Sciences\u003c\/a\u003e, \u003ca href=\"https:\/\/www.hamiltoncompany.com\/applications\/analytical-chemistry\"\u003eAnalytical Chemistry\u003c\/a\u003e, \u003ca href=\"https:\/\/www.hamiltoncompany.com\/applications\/analytical-chemistry\/gas-chromatography-mass-spectrometry-gc-ms\"\u003eGas Chromatography Mass Spectrometry (GC-MS)\u003c\/a\u003e \u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVolume\u003c\/th\u003e\n\u003ctd\u003e1 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSyringe Type\u003c\/th\u003e\n\u003ctd\u003eMicroliter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSyringe Series\u003c\/th\u003e\n\u003ctd\u003e7000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTermination\u003c\/th\u003e\n\u003ctd\u003eKnurled Hub (KH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle\u003c\/th\u003e\n\u003ctd\u003eKnurled Hub (KH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGauge\u003c\/th\u003e\n\u003ctd\u003e22 gauge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoint Style\u003c\/th\u003e\n\u003ctd\u003e3: Blunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle Length\u003c\/th\u003e\n\u003ctd\u003e2.75 inches (69.9 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePlunger Style\u003c\/th\u003e\n\u003ctd\u003eStandard Plunger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFluid Path\u003c\/th\u003e\n\u003ctd\u003eSST, Tungsten, Borosilicate Glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAutoclavable\u003c\/th\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas Sterilizable\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePressure\u003c\/th\u003e\n\u003ctd\u003e6000 psig (413.7 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMaximum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e80°C \/ 176°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum Operating Temperature\u003c\/th\u003e\n\u003ctd\u003e10°C \/ 50°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBarrel Inner Diameter\u003c\/th\u003e\n\u003ctd\u003e0.00490 inches (0.124 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBarrel Outer Diameter\u003c\/th\u003e\n\u003ctd\u003e0.308 inches (7.82 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle Inner Diameter\u003c\/th\u003e\n\u003ctd\u003e0.005 inches (0.13 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNeedle Outer Diameter\u003c\/th\u003e\n\u003ctd\u003e0.028 inches (0.711 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStd Needle Dead Volume\u003c\/th\u003e\n\u003ctd\u003e0 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSales Quantity\u003c\/th\u003e\n\u003ctd\u003e1 syringe per pack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSyringe Model Number\u003c\/th\u003e\n\u003ctd\u003e7101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/knowledge-base\/instructions\/instructions-7000-series-modified-microliter-syringe\"\u003eInstructions 7000 Series Modified Microliter Syringe (Instructions)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hamiltoncompany.com\/product-specs\/86207\"\u003e86207 (Specification)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hamilton Company","offers":[{"title":"Default Title","offer_id":46487502782543,"sku":"86207","price":866.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/86207.jpg?v=1787653377","url":"https:\/\/www.danyel.co.il\/products\/1-ul-microliter-syringe-with-guide-knurled-hub-2","provider":"danyel biotech","version":"1.0","type":"link"}