{"title":"Spectrophotometers \u0026 Fluorometers","description":"\u003cp\u003eUV-Vis and microvolume spectrophotometers alongside benchtop fluorometers for quantifying DNA, RNA, and protein — supported locally in Israel.\u003c\/p\u003e","products":[{"product_id":"broad-range-dna-quantification-kit-100-assays-f1000-br-100","title":"Broad Range DNA Quantification Kit, 100 assays","description":"The Accuris™ Smart-Q™ 100 \u0026amp; Smart-Q™ 800 Fluorometers are designed for the precise quantification of DNA, RNA, and protein samples. By utilizing well-established methodologies for fluorescence detection, the Smart-Q Fluorometers provide higher specificity and enhanced accuracy compared to the traditional method of UV-absorbance detection. Accurate results are particularly crucial in workflows involving:\n\nNext Generation Sequencing\nPCR\nTransfection\nWestern blotting\nImmunoassays\nThe Smart-Q Fluorometers are engineered to achieve optimal performance with Accuris’ Fluorescent DNA Quantification Kits and assay tubes; however, they also maintain compatibility with a range of kits offered by various other suppliers.\n\nIntuitive Usability\nEach instrument is equipped with a 7-inch color touchscreen, featuring an intuitive, icon-driven user interface. Preprogrammed protocols allow for quick \u0026amp; effortless assay set-up. Results are quickly calculated and displayed in less than 6 seconds, and saved to the instrument’s internal memory. All data can also be exported easily to a PC using a USB flash drive.\n\nAccurate Quantification\nThe Smart-Q Fluorometers, along with their accompanying assay kits, are engineered for the precise measurement of fluorescent dye signals that are bound to targeted biological molecules. These specially formulated dyes exhibit selective affinity towards DNA, RNA, or proteins, and generate fluorescent signals exclusively upon binding to their respective targets. Both Smart-Q models include Blue and Red channels that allow for various fluorescent dyes to be used in nucleic acid and protein measurements.\n\nThe Smart-Q Fluorometers incorporate advanced curve-fitting algorithms to establish calibration curves from standard samples of known concentrations.\n\nThe concentration of an unknown sample, whether it be DNA, RNA, or protein, is determined by correlating its Relative Fluorescence Units (RFUs) with those of the standards employed during calibration. The measurement sensitivity for each type of assay is distinct and defined by its detection limits.\n\nOptions for Throughput\nThe Smart-Q portfolio includes two distinct models, each designed to meet specific laboratory requirements:\n\nThe Smart-Q 100 allows for single-sample processing  in 0.5mL assay tubes (NS1020-T).  This renders the Smart-Q 100 ideal for laboratories processing fewer samples.\n\nThe Smart-Q 800 caters to high-throughput workflows and allows for up to eight samples to be evaluated at once using individual 0.2mL tubes or  8 x 0.2mL strips tubes (Order no. F1001-T and F1001-T-8, ). The use of a standard 8-channel pipettor can streamline both the reagent preparation and sample transfer, making the Smart-Q 800 an efficient solution for workflows requiring parallel processing of multiple samples.\n\nAccuris DNA Quantification Kits\nAccuris DNA Quantification Kits are designed for accurate fluorescent quantification of dsDNA using an instrument such as the SmartDrop XF, Qubit™or Accuris™ Fluorometer. The reagents are highly selective for double-stranded DNA (dsDNA), and not for single-stranded DNA (ssDNA), RNA, protein, or nucleotides.  Included with each kit are a concentrated assay reagent, dilution buffer, and ready-to-use DNA standards.  The assay reagent is diluted using the buffer provided, sample is added (1 µL to 20 µL of sample is needed), and the concentration can be determined using an appropriate fluorometer instrument.\n\nHigh Sensitivity dsDNA Assay Kit\nThe Accuris High Sensitivity kit provides an accurate method for quantitation of dsDNA samples when sensitivity is required.  Depending on sample volume, the assay kit is designed to be accurate for initial DNA sample concentrations of 0.005 to 120 ng\/µL, providing a detection range of 0.1−120 ng.  0.1 to 100 ng\/ul, providing detection of 0.1 to 100 ng\n\nBroad Range dsDNA Assay Kit\nThe Accuris Broad Range kit provides an accurate method for quantitation of dsDNA samples for a broad range quantity of DNA. Depending on sample volume, the assay kit is designed to be accurate for initial DNA sample concentrations of 0.2 to 2,000 ng\/µL, providing a detection range of 4−2,000 ng.\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2024\/05\/F1001_F1008-Literature-EM.pdf\"\u003eBrochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2024\/02\/NS1020-BR-100-Product-Insert.pdf\"\u003eManual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Benchmark Scientific","offers":[{"title":"Default Title","offer_id":45980601221199,"sku":"F1000-BR-100","price":583.0,"currency_code":"ILS","in_stock":true}]},{"product_id":"high-sensitivity-dna-quantification-kit-100-assays-f1000-hs-100","title":"High Sensitivity DNA Quantification Kit, 100 assays","description":"The Accuris™ Smart-Q™ 100 \u0026amp; Smart-Q™ 800 Fluorometers are designed for the precise quantification of DNA, RNA, and protein samples. By utilizing well-established methodologies for fluorescence detection, the Smart-Q Fluorometers provide higher specificity and enhanced accuracy compared to the traditional method of UV-absorbance detection. Accurate results are particularly crucial in workflows involving:\n\nNext Generation Sequencing\nPCR\nTransfection\nWestern blotting\nImmunoassays\nThe Smart-Q Fluorometers are engineered to achieve optimal performance with Accuris’ Fluorescent DNA Quantification Kits and assay tubes; however, they also maintain compatibility with a range of kits offered by various other suppliers.\n\nIntuitive Usability\nEach instrument is equipped with a 7-inch color touchscreen, featuring an intuitive, icon-driven user interface. Preprogrammed protocols allow for quick \u0026amp; effortless assay set-up. Results are quickly calculated and displayed in less than 6 seconds, and saved to the instrument’s internal memory. All data can also be exported easily to a PC using a USB flash drive.\n\nAccurate Quantification\nThe Smart-Q Fluorometers, along with their accompanying assay kits, are engineered for the precise measurement of fluorescent dye signals that are bound to targeted biological molecules. These specially formulated dyes exhibit selective affinity towards DNA, RNA, or proteins, and generate fluorescent signals exclusively upon binding to their respective targets. Both Smart-Q models include Blue and Red channels that allow for various fluorescent dyes to be used in nucleic acid and protein measurements.\n\nThe Smart-Q Fluorometers incorporate advanced curve-fitting algorithms to establish calibration curves from standard samples of known concentrations.\n\nThe concentration of an unknown sample, whether it be DNA, RNA, or protein, is determined by correlating its Relative Fluorescence Units (RFUs) with those of the standards employed during calibration. The measurement sensitivity for each type of assay is distinct and defined by its detection limits.\n\nOptions for Throughput\nThe Smart-Q portfolio includes two distinct models, each designed to meet specific laboratory requirements:\n\nThe Smart-Q 100 allows for single-sample processing  in 0.5mL assay tubes (NS1020-T).  This renders the Smart-Q 100 ideal for laboratories processing fewer samples.\n\nThe Smart-Q 800 caters to high-throughput workflows and allows for up to eight samples to be evaluated at once using individual 0.2mL tubes or  8 x 0.2mL strips tubes (Order no. F1001-T and F1001-T-8, ). The use of a standard 8-channel pipettor can streamline both the reagent preparation and sample transfer, making the Smart-Q 800 an efficient solution for workflows requiring parallel processing of multiple samples.\n\nAccuris DNA Quantification Kits\nAccuris DNA Quantification Kits are designed for accurate fluorescent quantification of dsDNA using an instrument such as the SmartDrop XF, Qubit™or Accuris™ Fluorometer. The reagents are highly selective for double-stranded DNA (dsDNA), and not for single-stranded DNA (ssDNA), RNA, protein, or nucleotides.  Included with each kit are a concentrated assay reagent, dilution buffer, and ready-to-use DNA standards.  The assay reagent is diluted using the buffer provided, sample is added (1 µL to 20 µL of sample is needed), and the concentration can be determined using an appropriate fluorometer instrument.\n\nHigh Sensitivity dsDNA Assay Kit\nThe Accuris High Sensitivity kit provides an accurate method for quantitation of dsDNA samples when sensitivity is required.  Depending on sample volume, the assay kit is designed to be accurate for initial DNA sample concentrations of 0.005 to 120 ng\/µL, providing a detection range of 0.1−120 ng.  0.1 to 100 ng\/ul, providing detection of 0.1 to 100 ng\n\nBroad Range dsDNA Assay Kit\nThe Accuris Broad Range kit provides an accurate method for quantitation of dsDNA samples for a broad range quantity of DNA. Depending on sample volume, the assay kit is designed to be accurate for initial DNA sample concentrations of 0.2 to 2,000 ng\/µL, providing a detection range of 4−2,000 ng.\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2024\/05\/F1001_F1008-Literature-EM.pdf\"\u003eBrochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2024\/02\/NS1020-HS-100-Product-Insert.pdf\"\u003eManual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Benchmark Scientific","offers":[{"title":"Default Title","offer_id":45980601974863,"sku":"F1000-HS-100","price":583.0,"currency_code":"ILS","in_stock":true}]},{"product_id":"accuris-smart-q-100-fluorometer-for-single-samples-f1001-e","title":"Accuris™ Smart-Q™ 100 Fluorometer for single samples","description":"The Accuris™ Smart-Q™ 100 \u0026amp; Smart-Q™ 800 Fluorometers are designed for the precise quantification of DNA, RNA, and protein samples. By utilizing well-established methodologies for fluorescence detection, the Smart-Q Fluorometers provide higher specificity and enhanced accuracy compared to the traditional method of UV-absorbance detection. Accurate results are particularly crucial in workflows involving:\n\nNext Generation Sequencing\nPCR\nTransfection\nWestern blotting\nImmunoassays\nThe Smart-Q Fluorometers are engineered to achieve optimal performance with Accuris’ Fluorescent DNA Quantification Kits and assay tubes; however, they also maintain compatibility with a range of kits offered by various other suppliers.\n\nIntuitive Usability\nEach instrument is equipped with a 7-inch color touchscreen, featuring an intuitive, icon-driven user interface. Preprogrammed protocols allow for quick \u0026amp; effortless assay set-up. Results are quickly calculated and displayed in less than 6 seconds, and saved to the instrument’s internal memory. All data can also be exported easily to a PC using a USB flash drive.\n\nAccurate Quantification\nThe Smart-Q Fluorometers, along with their accompanying assay kits, are engineered for the precise measurement of fluorescent dye signals that are bound to targeted biological molecules. These specially formulated dyes exhibit selective affinity towards DNA, RNA, or proteins, and generate fluorescent signals exclusively upon binding to their respective targets. Both Smart-Q models include Blue and Red channels that allow for various fluorescent dyes to be used in nucleic acid and protein measurements.\n\nThe Smart-Q Fluorometers incorporate advanced curve-fitting algorithms to establish calibration curves from standard samples of known concentrations.\n\nThe concentration of an unknown sample, whether it be DNA, RNA, or protein, is determined by correlating its Relative Fluorescence Units (RFUs) with those of the standards employed during calibration. The measurement sensitivity for each type of assay is distinct and defined by its detection limits.\n\nOptions for Throughput\nThe Smart-Q portfolio includes two distinct models, each designed to meet specific laboratory requirements:\n\nThe Smart-Q 100 allows for single-sample processing  in 0.5mL assay tubes (NS1020-T).  This renders the Smart-Q 100 ideal for laboratories processing fewer samples.\n\nThe Smart-Q 800 caters to high-throughput workflows and allows for up to eight samples to be evaluated at once using individual 0.2mL tubes or  8 x 0.2mL strips tubes (Order no. F1001-T and F1001-T-8, ). The use of a standard 8-channel pipettor can streamline both the reagent preparation and sample transfer, making the Smart-Q 800 an efficient solution for workflows requiring parallel processing of multiple samples.\n\nAccuris DNA Quantification Kits\nAccuris DNA Quantification Kits are designed for accurate fluorescent quantification of dsDNA using an instrument such as the SmartDrop XF, Qubit™or Accuris™ Fluorometer. The reagents are highly selective for double-stranded DNA (dsDNA), and not for single-stranded DNA (ssDNA), RNA, protein, or nucleotides.  Included with each kit are a concentrated assay reagent, dilution buffer, and ready-to-use DNA standards.  The assay reagent is diluted using the buffer provided, sample is added (1 µL to 20 µL of sample is needed), and the concentration can be determined using an appropriate fluorometer instrument.\n\nHigh Sensitivity dsDNA Assay Kit\nThe Accuris High Sensitivity kit provides an accurate method for quantitation of dsDNA samples when sensitivity is required.  Depending on sample volume, the assay kit is designed to be accurate for initial DNA sample concentrations of 0.005 to 120 ng\/µL, providing a detection range of 0.1−120 ng.  0.1 to 100 ng\/ul, providing detection of 0.1 to 100 ng\n\nBroad Range dsDNA Assay Kit\nThe Accuris Broad Range kit provides an accurate method for quantitation of dsDNA samples for a broad range quantity of DNA. Depending on sample volume, the assay kit is designed to be accurate for initial DNA sample concentrations of 0.2 to 2,000 ng\/µL, providing a detection range of 4−2,000 ng.\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e7.0-inch, color touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDynamic Range\u003c\/th\u003e\n\u003ctd\u003e5 orders of magnitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLight Source\u003c\/th\u003e\n\u003ctd\u003eBlue and Red LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExcitation Wavelengths\u003c\/th\u003e\n\u003ctd\u003eBlue: 460 ± 20nm and Red: 625 ± 20nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEmission Wavelengths\u003c\/th\u003e\n\u003ctd\u003eGreen: 525 – 570nm and Red: 670 – 725nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStability\u003c\/th\u003e\n\u003ctd\u003e≤ 1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetector\u003c\/th\u003e\n\u003ctd\u003ePhotodiodes (300-1000nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement Speed\u003c\/th\u003e\n\u003ctd\u003e≤ 5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConsumable type\u003c\/th\u003e\n\u003ctd\u003e0.5mL assay tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e24 VDC 2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (WxDxH)\u003c\/th\u003e\n\u003ctd\u003e16.1 x 28.7 x 6.1cm \/ 6.34 x 11.30 x 2.40in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e1.6kg \/ 3.5lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2024\/05\/F1001_F1008-Literature-EM.pdf\"\u003eBrochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2024\/01\/F1001-User-Manual-V1.1.pdf\"\u003eManual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Benchmark Scientific","offers":[{"title":"Default Title","offer_id":45980602990671,"sku":"F1001-E","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/F1001-Front-View-600x600px_69a94f31-7ac2-4a01-b564-166a9591d0cb.jpg?v=1782907989"},{"product_id":"0-5ml-fluorescence-detection-tubes-pack-of-250-f1001-t","title":"0.5mL Fluorescence Detection Tubes, pack of 250","description":"The Accuris™ Smart-Q™ 100 \u0026amp; Smart-Q™ 800 Fluorometers are designed for the precise quantification of DNA, RNA, and protein samples. By utilizing well-established methodologies for fluorescence detection, the Smart-Q Fluorometers provide higher specificity and enhanced accuracy compared to the traditional method of UV-absorbance detection. Accurate results are particularly crucial in workflows involving:\n\nNext Generation Sequencing\nPCR\nTransfection\nWestern blotting\nImmunoassays\nThe Smart-Q Fluorometers are engineered to achieve optimal performance with Accuris’ Fluorescent DNA Quantification Kits and assay tubes; however, they also maintain compatibility with a range of kits offered by various other suppliers.\n\nIntuitive Usability\nEach instrument is equipped with a 7-inch color touchscreen, featuring an intuitive, icon-driven user interface. Preprogrammed protocols allow for quick \u0026amp; effortless assay set-up. Results are quickly calculated and displayed in less than 6 seconds, and saved to the instrument’s internal memory. All data can also be exported easily to a PC using a USB flash drive.\n\nAccurate Quantification\nThe Smart-Q Fluorometers, along with their accompanying assay kits, are engineered for the precise measurement of fluorescent dye signals that are bound to targeted biological molecules. These specially formulated dyes exhibit selective affinity towards DNA, RNA, or proteins, and generate fluorescent signals exclusively upon binding to their respective targets. Both Smart-Q models include Blue and Red channels that allow for various fluorescent dyes to be used in nucleic acid and protein measurements.\n\nThe Smart-Q Fluorometers incorporate advanced curve-fitting algorithms to establish calibration curves from standard samples of known concentrations.\n\nThe concentration of an unknown sample, whether it be DNA, RNA, or protein, is determined by correlating its Relative Fluorescence Units (RFUs) with those of the standards employed during calibration. The measurement sensitivity for each type of assay is distinct and defined by its detection limits.\n\nOptions for Throughput\nThe Smart-Q portfolio includes two distinct models, each designed to meet specific laboratory requirements:\n\nThe Smart-Q 100 allows for single-sample processing  in 0.5mL assay tubes (NS1020-T).  This renders the Smart-Q 100 ideal for laboratories processing fewer samples.\n\nThe Smart-Q 800 caters to high-throughput workflows and allows for up to eight samples to be evaluated at once using individual 0.2mL tubes or  8 x 0.2mL strips tubes (Order no. F1001-T and F1001-T-8, ). The use of a standard 8-channel pipettor can streamline both the reagent preparation and sample transfer, making the Smart-Q 800 an efficient solution for workflows requiring parallel processing of multiple samples.\n\nAccuris DNA Quantification Kits\nAccuris DNA Quantification Kits are designed for accurate fluorescent quantification of dsDNA using an instrument such as the SmartDrop XF, Qubit™or Accuris™ Fluorometer. The reagents are highly selective for double-stranded DNA (dsDNA), and not for single-stranded DNA (ssDNA), RNA, protein, or nucleotides.  Included with each kit are a concentrated assay reagent, dilution buffer, and ready-to-use DNA standards.  The assay reagent is diluted using the buffer provided, sample is added (1 µL to 20 µL of sample is needed), and the concentration can be determined using an appropriate fluorometer instrument.\n\nHigh Sensitivity dsDNA Assay Kit\nThe Accuris High Sensitivity kit provides an accurate method for quantitation of dsDNA samples when sensitivity is required.  Depending on sample volume, the assay kit is designed to be accurate for initial DNA sample concentrations of 0.005 to 120 ng\/µL, providing a detection range of 0.1−120 ng.  0.1 to 100 ng\/ul, providing detection of 0.1 to 100 ng\n\nBroad Range dsDNA Assay Kit\nThe Accuris Broad Range kit provides an accurate method for quantitation of dsDNA samples for a broad range quantity of DNA. Depending on sample volume, the assay kit is designed to be accurate for initial DNA sample concentrations of 0.2 to 2,000 ng\/µL, providing a detection range of 4−2,000 ng.\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2024\/05\/F1001_F1008-Literature-EM.pdf\"\u003eBrochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Benchmark Scientific","offers":[{"title":"Default Title","offer_id":45980603121743,"sku":"F1001-T","price":265.0,"currency_code":"ILS","in_stock":true}]},{"product_id":"accuris-smart-q-800-fluorometer-for-8-samples-f1008-e","title":"Accuris™ Smart-Q™ 800 Fluorometer for 8-samples","description":"The Accuris™ Smart-Q™ 100 \u0026amp; Smart-Q™ 800 Fluorometers are designed for the precise quantification of DNA, RNA, and protein samples. By utilizing well-established methodologies for fluorescence detection, the Smart-Q Fluorometers provide higher specificity and enhanced accuracy compared to the traditional method of UV-absorbance detection. Accurate results are particularly crucial in workflows involving:\n\nNext Generation Sequencing\nPCR\nTransfection\nWestern blotting\nImmunoassays\nThe Smart-Q Fluorometers are engineered to achieve optimal performance with Accuris’ Fluorescent DNA Quantification Kits and assay tubes; however, they also maintain compatibility with a range of kits offered by various other suppliers.\n\nIntuitive Usability\nEach instrument is equipped with a 7-inch color touchscreen, featuring an intuitive, icon-driven user interface. Preprogrammed protocols allow for quick \u0026amp; effortless assay set-up. Results are quickly calculated and displayed in less than 6 seconds, and saved to the instrument’s internal memory. All data can also be exported easily to a PC using a USB flash drive.\n\nAccurate Quantification\nThe Smart-Q Fluorometers, along with their accompanying assay kits, are engineered for the precise measurement of fluorescent dye signals that are bound to targeted biological molecules. These specially formulated dyes exhibit selective affinity towards DNA, RNA, or proteins, and generate fluorescent signals exclusively upon binding to their respective targets. Both Smart-Q models include Blue and Red channels that allow for various fluorescent dyes to be used in nucleic acid and protein measurements.\n\nThe Smart-Q Fluorometers incorporate advanced curve-fitting algorithms to establish calibration curves from standard samples of known concentrations.\n\nThe concentration of an unknown sample, whether it be DNA, RNA, or protein, is determined by correlating its Relative Fluorescence Units (RFUs) with those of the standards employed during calibration. The measurement sensitivity for each type of assay is distinct and defined by its detection limits.\n\nOptions for Throughput\nThe Smart-Q portfolio includes two distinct models, each designed to meet specific laboratory requirements:\n\nThe Smart-Q 100 allows for single-sample processing  in 0.5mL assay tubes (NS1020-T).  This renders the Smart-Q 100 ideal for laboratories processing fewer samples.\n\nThe Smart-Q 800 caters to high-throughput workflows and allows for up to eight samples to be evaluated at once using individual 0.2mL tubes or  8 x 0.2mL strips tubes (Order no. F1001-T and F1001-T-8, ). The use of a standard 8-channel pipettor can streamline both the reagent preparation and sample transfer, making the Smart-Q 800 an efficient solution for workflows requiring parallel processing of multiple samples.\n\nAccuris DNA Quantification Kits\nAccuris DNA Quantification Kits are designed for accurate fluorescent quantification of dsDNA using an instrument such as the SmartDrop XF, Qubit™or Accuris™ Fluorometer. The reagents are highly selective for double-stranded DNA (dsDNA), and not for single-stranded DNA (ssDNA), RNA, protein, or nucleotides.  Included with each kit are a concentrated assay reagent, dilution buffer, and ready-to-use DNA standards.  The assay reagent is diluted using the buffer provided, sample is added (1 µL to 20 µL of sample is needed), and the concentration can be determined using an appropriate fluorometer instrument.\n\nHigh Sensitivity dsDNA Assay Kit\nThe Accuris High Sensitivity kit provides an accurate method for quantitation of dsDNA samples when sensitivity is required.  Depending on sample volume, the assay kit is designed to be accurate for initial DNA sample concentrations of 0.005 to 120 ng\/µL, providing a detection range of 0.1−120 ng.  0.1 to 100 ng\/ul, providing detection of 0.1 to 100 ng\n\nBroad Range dsDNA Assay Kit\nThe Accuris Broad Range kit provides an accurate method for quantitation of dsDNA samples for a broad range quantity of DNA. Depending on sample volume, the assay kit is designed to be accurate for initial DNA sample concentrations of 0.2 to 2,000 ng\/µL, providing a detection range of 4−2,000 ng.\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e7.0-inch, color touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDynamic Range\u003c\/th\u003e\n\u003ctd\u003e4 orders of magnitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLight Source\u003c\/th\u003e\n\u003ctd\u003eBlue and Red LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExcitation Wavelengths\u003c\/th\u003e\n\u003ctd\u003eBlue: 460 ± 20nm and Red: 625 ± 20nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEmission Wavelengths\u003c\/th\u003e\n\u003ctd\u003eGreen: 525 – 570nm and Red: 670 – 725nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStability\u003c\/th\u003e\n\u003ctd\u003e≤ 1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetector\u003c\/th\u003e\n\u003ctd\u003ePhotodiodes (300-1000nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasurement Speed\u003c\/th\u003e\n\u003ctd\u003e≤ 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConsumable type\u003c\/th\u003e\n\u003ctd\u003e0.2mL assay tubes (single and 8-tube strip)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eInput Voltage\u003c\/th\u003e\n\u003ctd\u003e24 VDC 2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (WxDxH)\u003c\/th\u003e\n\u003ctd\u003e16.1 x 28.7 x 7.6 cm \/ 6.3 x 11.3 x 3.0 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e2.0kg \/ 4.4lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2024\/05\/F1001_F1008-Literature-EM.pdf\"\u003eBrochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2024\/02\/F1008-User-Manual-V1.1.pdf\"\u003eManual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Benchmark Scientific","offers":[{"title":"Default Title","offer_id":45980604858447,"sku":"F1008-E","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/F1001-Front-View-600x600px_69a94f31-7ac2-4a01-b564-166a9591d0cb.jpg?v=1782907989"},{"product_id":"smart-q-800-assay-tubes-pack-of-1000-f1008-t","title":"Smart-Q™ 800 Assay Tubes, pack of 1000","description":"The Accuris™ Smart-Q™ 100 \u0026amp; Smart-Q™ 800 Fluorometers are designed for the precise quantification of DNA, RNA, and protein samples. By utilizing well-established methodologies for fluorescence detection, the Smart-Q Fluorometers provide higher specificity and enhanced accuracy compared to the traditional method of UV-absorbance detection. Accurate results are particularly crucial in workflows involving:\n\nNext Generation Sequencing\nPCR\nTransfection\nWestern blotting\nImmunoassays\nThe Smart-Q Fluorometers are engineered to achieve optimal performance with Accuris’ Fluorescent DNA Quantification Kits and assay tubes; however, they also maintain compatibility with a range of kits offered by various other suppliers.\n\nIntuitive Usability\nEach instrument is equipped with a 7-inch color touchscreen, featuring an intuitive, icon-driven user interface. Preprogrammed protocols allow for quick \u0026amp; effortless assay set-up. Results are quickly calculated and displayed in less than 6 seconds, and saved to the instrument’s internal memory. All data can also be exported easily to a PC using a USB flash drive.\n\nAccurate Quantification\nThe Smart-Q Fluorometers, along with their accompanying assay kits, are engineered for the precise measurement of fluorescent dye signals that are bound to targeted biological molecules. These specially formulated dyes exhibit selective affinity towards DNA, RNA, or proteins, and generate fluorescent signals exclusively upon binding to their respective targets. Both Smart-Q models include Blue and Red channels that allow for various fluorescent dyes to be used in nucleic acid and protein measurements.\n\nThe Smart-Q Fluorometers incorporate advanced curve-fitting algorithms to establish calibration curves from standard samples of known concentrations.\n\nThe concentration of an unknown sample, whether it be DNA, RNA, or protein, is determined by correlating its Relative Fluorescence Units (RFUs) with those of the standards employed during calibration. The measurement sensitivity for each type of assay is distinct and defined by its detection limits.\n\nOptions for Throughput\nThe Smart-Q portfolio includes two distinct models, each designed to meet specific laboratory requirements:\n\nThe Smart-Q 100 allows for single-sample processing  in 0.5mL assay tubes (NS1020-T).  This renders the Smart-Q 100 ideal for laboratories processing fewer samples.\n\nThe Smart-Q 800 caters to high-throughput workflows and allows for up to eight samples to be evaluated at once using individual 0.2mL tubes or  8 x 0.2mL strips tubes (Order no. F1001-T and F1001-T-8, ). The use of a standard 8-channel pipettor can streamline both the reagent preparation and sample transfer, making the Smart-Q 800 an efficient solution for workflows requiring parallel processing of multiple samples.\n\nAccuris DNA Quantification Kits\nAccuris DNA Quantification Kits are designed for accurate fluorescent quantification of dsDNA using an instrument such as the SmartDrop XF, Qubit™or Accuris™ Fluorometer. The reagents are highly selective for double-stranded DNA (dsDNA), and not for single-stranded DNA (ssDNA), RNA, protein, or nucleotides.  Included with each kit are a concentrated assay reagent, dilution buffer, and ready-to-use DNA standards.  The assay reagent is diluted using the buffer provided, sample is added (1 µL to 20 µL of sample is needed), and the concentration can be determined using an appropriate fluorometer instrument.\n\nHigh Sensitivity dsDNA Assay Kit\nThe Accuris High Sensitivity kit provides an accurate method for quantitation of dsDNA samples when sensitivity is required.  Depending on sample volume, the assay kit is designed to be accurate for initial DNA sample concentrations of 0.005 to 120 ng\/µL, providing a detection range of 0.1−120 ng.  0.1 to 100 ng\/ul, providing detection of 0.1 to 100 ng\n\nBroad Range dsDNA Assay Kit\nThe Accuris Broad Range kit provides an accurate method for quantitation of dsDNA samples for a broad range quantity of DNA. Depending on sample volume, the assay kit is designed to be accurate for initial DNA sample concentrations of 0.2 to 2,000 ng\/µL, providing a detection range of 4−2,000 ng.\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2024\/05\/F1001_F1008-Literature-EM.pdf\"\u003eBrochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Benchmark Scientific","offers":[{"title":"Default Title","offer_id":45980605055055,"sku":"F1008-T","price":372.0,"currency_code":"ILS","in_stock":true}]},{"product_id":"smart-q-800-assay-tube-strips-pack-of-120-f1008-t-8","title":"Smart-Q™ 800 Assay Tube Strips, pack of 120","description":"The Accuris™ Smart-Q™ 100 \u0026amp; Smart-Q™ 800 Fluorometers are designed for the precise quantification of DNA, RNA, and protein samples. By utilizing well-established methodologies for fluorescence detection, the Smart-Q Fluorometers provide higher specificity and enhanced accuracy compared to the traditional method of UV-absorbance detection. Accurate results are particularly crucial in workflows involving:\n\nNext Generation Sequencing\nPCR\nTransfection\nWestern blotting\nImmunoassays\nThe Smart-Q Fluorometers are engineered to achieve optimal performance with Accuris’ Fluorescent DNA Quantification Kits and assay tubes; however, they also maintain compatibility with a range of kits offered by various other suppliers.\n\nIntuitive Usability\nEach instrument is equipped with a 7-inch color touchscreen, featuring an intuitive, icon-driven user interface. Preprogrammed protocols allow for quick \u0026amp; effortless assay set-up. Results are quickly calculated and displayed in less than 6 seconds, and saved to the instrument’s internal memory. All data can also be exported easily to a PC using a USB flash drive.\n\nAccurate Quantification\nThe Smart-Q Fluorometers, along with their accompanying assay kits, are engineered for the precise measurement of fluorescent dye signals that are bound to targeted biological molecules. These specially formulated dyes exhibit selective affinity towards DNA, RNA, or proteins, and generate fluorescent signals exclusively upon binding to their respective targets. Both Smart-Q models include Blue and Red channels that allow for various fluorescent dyes to be used in nucleic acid and protein measurements.\n\nThe Smart-Q Fluorometers incorporate advanced curve-fitting algorithms to establish calibration curves from standard samples of known concentrations.\n\nThe concentration of an unknown sample, whether it be DNA, RNA, or protein, is determined by correlating its Relative Fluorescence Units (RFUs) with those of the standards employed during calibration. The measurement sensitivity for each type of assay is distinct and defined by its detection limits.\n\nOptions for Throughput\nThe Smart-Q portfolio includes two distinct models, each designed to meet specific laboratory requirements:\n\nThe Smart-Q 100 allows for single-sample processing  in 0.5mL assay tubes (NS1020-T).  This renders the Smart-Q 100 ideal for laboratories processing fewer samples.\n\nThe Smart-Q 800 caters to high-throughput workflows and allows for up to eight samples to be evaluated at once using individual 0.2mL tubes or  8 x 0.2mL strips tubes (Order no. F1001-T and F1001-T-8, ). The use of a standard 8-channel pipettor can streamline both the reagent preparation and sample transfer, making the Smart-Q 800 an efficient solution for workflows requiring parallel processing of multiple samples.\n\nAccuris DNA Quantification Kits\nAccuris DNA Quantification Kits are designed for accurate fluorescent quantification of dsDNA using an instrument such as the SmartDrop XF, Qubit™or Accuris™ Fluorometer. The reagents are highly selective for double-stranded DNA (dsDNA), and not for single-stranded DNA (ssDNA), RNA, protein, or nucleotides.  Included with each kit are a concentrated assay reagent, dilution buffer, and ready-to-use DNA standards.  The assay reagent is diluted using the buffer provided, sample is added (1 µL to 20 µL of sample is needed), and the concentration can be determined using an appropriate fluorometer instrument.\n\nHigh Sensitivity dsDNA Assay Kit\nThe Accuris High Sensitivity kit provides an accurate method for quantitation of dsDNA samples when sensitivity is required.  Depending on sample volume, the assay kit is designed to be accurate for initial DNA sample concentrations of 0.005 to 120 ng\/µL, providing a detection range of 0.1−120 ng.  0.1 to 100 ng\/ul, providing detection of 0.1 to 100 ng\n\nBroad Range dsDNA Assay Kit\nThe Accuris Broad Range kit provides an accurate method for quantitation of dsDNA samples for a broad range quantity of DNA. Depending on sample volume, the assay kit is designed to be accurate for initial DNA sample concentrations of 0.2 to 2,000 ng\/µL, providing a detection range of 4−2,000 ng.\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2024\/05\/F1001_F1008-Literature-EM.pdf\"\u003eBrochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Benchmark Scientific","offers":[{"title":"Default Title","offer_id":45980605612111,"sku":"F1008-T-8","price":566.0,"currency_code":"ILS","in_stock":true}]},{"product_id":"smartdrop-x-nano-spectrophotometer-ns1010-e","title":"SmartDrop™ X Nano Spectrophotometer","description":"SmartDrop L\nIdeal for basic DNA\/RNA\/protein quantification and purity\nAffordable LED and silicon detector technology\nFixed 0.5mm path length, detect up to 2500ng\/µl of dsDNA\nSmartDrop L is the affordable choice for laboratories needing to determine nucleic acid and protein concentrations and purity of samples. The LED light source and silicon photocell sensor provide readings at 260 and 280nm. Samples from 1.0 to 2.0µl are loaded directly on the pedestal. Results are provided in about 5 seconds. The software automatically\ncalculates and displays 260\/280 ratios.\n\nSmartDrop X\nFull-spectrum absorbance scans from 200 to 800nm\nQuickly calculates and displays 260\/280 and 260\/230 ratios\nLong-life Xenon lamp with precision monochromator\nAuto-ranging path lengths of 0.2mm and 1.0mm\nDetect up to 4,500 ng\/µl of dsDNA without dilution\nA full spectrum UV-Vis spectrophotometer, SmartDrop X requires 0.5 to 2.0µl of sample. In addition to nucleic acid and protein calculations, the software has preset programs for BCA, Bradford and Lowry assays. A full spectrum analysis can be performed in about 6 seconds, aiding in the\nidentification of unknowns. Up to 5 specific points on the spectrum can be selected for colorimetric readings output. The long life Xenon lamp source requires no warm up and is paired with a highly sensitive CCD detector. To provide the most accurate results, the SmartDrop X utilizes 2 path lengths.\n\nSmartDrop XF – Spectrophotometer + Fluorometer\nFull-spectrum absorbance scanning and calculations of\n260\/280 and 260\/230 ratios\nLong-life Xenon lamp with precision monochromator\nAuto-ranging path lengths of 0.05mm, 0.2mm and\n1.0mm\nDetect up to 15,000ng\/µl of dsDNA without dilution\nIntegrated fluorometer for sensitive quantitation of low\nconcentration nucleic acids\nThis top of the line spectrophotometer can perform not only UV-Vis readings in the range of 200-800nm but also fluorescence readings. Like the SmartDrop X, the SmartDrop XF features predefined programs for nucleic acids, proteins, and various colorimetric assays. The patented, motorized system gently stretches the sample column and allows for three different path lengths, providing accurate readings of samples from 0.5 to 2.0µl without dilution.\nThe integrated fluorometer yields more accurate, sensitive and selective quantitation of nucleic acids. The blue light channel (460nm) is useful for detection of dyes such as PicoGreen and RiboGreen as well as GFP and fluorescein. UV, green and red channel models are available upon\nrequest.\n\nAccuris DNA Quantification Kits\nAccuris DNA Quantification Kits are designed for accurate fluorescent quantification of dsDNA using instruments such as the Qubit®, SmartDrop™ XF, and microplate readers.  The reagents are highly selective for double-stranded DNA (dsDNA); quantification results will not be skewed by single-stranded DNA (ssDNA), RNA, protein, or nucleotides in a sample.  Included with each kit are a concentrated fluorescent assay reagent, dilution buffer, and ready-to-use DNA standards.  The assay reagent is diluted using the buffer provided, sample is added (1 µL to 20 µL), and the concentration determined using an appropriate fluorometer instrument that utilizes blue excitation (460 ± 20 nm) and measures green fluorescence (525-570 nm).\n\nHigh Sensitivity dsDNA Assay Kit\nThe Accuris High Sensitivity Kit provides an accurate method to quantify low concentration dsDNA samples.  The assay kit is designed to be accurate for initial DNA sample concentrations of 0.005–120 ng\/µl, providing a detection range of 0.1–120 ng.\n\nBroad Range dsDNA Assay Kit\nThe Accuris Broad Range Kit provides an accurate method to quantify dsDNA samples that have a broad concentration range starting at 0.2 ng\/µL. The assay kit is designed to be accurate for initial DNA sample concentrations of 0.2 to 2,000 ng\/µL, providing a detection range of 4−2,000 ng.\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e7-inch touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum sample size\u003c\/th\u003e\n\u003ctd\u003e0.5µl – 2.0µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePath length\u003c\/th\u003e\n\u003ctd\u003e0.2mm, 1.0mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLight source\u003c\/th\u003e\n\u003ctd\u003eXenon Flash Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetector\u003c\/th\u003e\n\u003ctd\u003e2048 Element Linear Silicon CCD Array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWavelength\u003c\/th\u003e\n\u003ctd\u003e200 – 800nm (1nm steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAbsorbance range\u003c\/th\u003e\n\u003ctd\u003e00.04 – 90 A (10mm equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAbsorbance precision\u003c\/th\u003e\n\u003ctd\u003e0.003 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLower limit of detection\u003c\/th\u003e\n\u003ctd\u003edsDNA: 2ng\/µl; BSA: 0.1mg\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUpper limit of detection\u003c\/th\u003e\n\u003ctd\u003edsDNA: 4,500ng\/µl; BSA: 135mg\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection time\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication ports\u003c\/th\u003e\n\u003ctd\u003eUSB for data export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage input\u003c\/th\u003e\n\u003ctd\u003eDC 24V, 2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e25W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (WxDxH)\u003c\/th\u003e\n\u003ctd\u003e8.3 x 10.6 x 7.2 in. \/ 21.0 x 26.8 x 18.1cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e2.8 kg \/ 6.2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAbsorbance range\u003c\/th\u003e\n\u003ctd\u003e0.0 – 4.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAbsorbance stability\u003c\/th\u003e\n\u003ctd\u003e[0,3) ≤ 0.5%, [3,4) ≤ 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAbsorbance repeatibility\u003c\/th\u003e\n\u003ctd\u003e[0,3) ≤ 0.5%, [3,4) ≤ 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAbsorbance precision\u003c\/th\u003e\n\u003ctd\u003e[0,2) ≤ 0.005 A, [2,3) ≤ 1%, [3,4) ≤ 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2022\/08\/NS1000-Series-Literature.pdf\"\u003eBrochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2022\/08\/NS1020-Operation-Manual.pdf\"\u003eManual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Benchmark Scientific","offers":[{"title":"Default Title","offer_id":45980652044367,"sku":"NS1010-E","price":0.0,"currency_code":"ILS","in_stock":true}]},{"product_id":"broad-range-dna-quantification-kit-100-assays-ns1020-br-100","title":"Broad Range DNA Quantification Kit, 100 assays","description":"SmartDrop L\nIdeal for basic DNA\/RNA\/protein quantification and purity\nAffordable LED and silicon detector technology\nFixed 0.5mm path length, detect up to 2500ng\/µl of dsDNA\nSmartDrop L is the affordable choice for laboratories needing to determine nucleic acid and protein concentrations and purity of samples. The LED light source and silicon photocell sensor provide readings at 260 and 280nm. Samples from 1.0 to 2.0µl are loaded directly on the pedestal. Results are provided in about 5 seconds. The software automatically\ncalculates and displays 260\/280 ratios.\n\nSmartDrop X\nFull-spectrum absorbance scans from 200 to 800nm\nQuickly calculates and displays 260\/280 and 260\/230 ratios\nLong-life Xenon lamp with precision monochromator\nAuto-ranging path lengths of 0.2mm and 1.0mm\nDetect up to 4,500 ng\/µl of dsDNA without dilution\nA full spectrum UV-Vis spectrophotometer, SmartDrop X requires 0.5 to 2.0µl of sample. In addition to nucleic acid and protein calculations, the software has preset programs for BCA, Bradford and Lowry assays. A full spectrum analysis can be performed in about 6 seconds, aiding in the\nidentification of unknowns. Up to 5 specific points on the spectrum can be selected for colorimetric readings output. The long life Xenon lamp source requires no warm up and is paired with a highly sensitive CCD detector. To provide the most accurate results, the SmartDrop X utilizes 2 path lengths.\n\nSmartDrop XF – Spectrophotometer + Fluorometer\nFull-spectrum absorbance scanning and calculations of\n260\/280 and 260\/230 ratios\nLong-life Xenon lamp with precision monochromator\nAuto-ranging path lengths of 0.05mm, 0.2mm and\n1.0mm\nDetect up to 15,000ng\/µl of dsDNA without dilution\nIntegrated fluorometer for sensitive quantitation of low\nconcentration nucleic acids\nThis top of the line spectrophotometer can perform not only UV-Vis readings in the range of 200-800nm but also fluorescence readings. Like the SmartDrop X, the SmartDrop XF features predefined programs for nucleic acids, proteins, and various colorimetric assays. The patented, motorized system gently stretches the sample column and allows for three different path lengths, providing accurate readings of samples from 0.5 to 2.0µl without dilution.\nThe integrated fluorometer yields more accurate, sensitive and selective quantitation of nucleic acids. The blue light channel (460nm) is useful for detection of dyes such as PicoGreen and RiboGreen as well as GFP and fluorescein. UV, green and red channel models are available upon\nrequest.\n\nAccuris DNA Quantification Kits\nAccuris DNA Quantification Kits are designed for accurate fluorescent quantification of dsDNA using instruments such as the Qubit®, SmartDrop™ XF, and microplate readers.  The reagents are highly selective for double-stranded DNA (dsDNA); quantification results will not be skewed by single-stranded DNA (ssDNA), RNA, protein, or nucleotides in a sample.  Included with each kit are a concentrated fluorescent assay reagent, dilution buffer, and ready-to-use DNA standards.  The assay reagent is diluted using the buffer provided, sample is added (1 µL to 20 µL), and the concentration determined using an appropriate fluorometer instrument that utilizes blue excitation (460 ± 20 nm) and measures green fluorescence (525-570 nm).\n\nHigh Sensitivity dsDNA Assay Kit\nThe Accuris High Sensitivity Kit provides an accurate method to quantify low concentration dsDNA samples.  The assay kit is designed to be accurate for initial DNA sample concentrations of 0.005–120 ng\/µl, providing a detection range of 0.1–120 ng.\n\nBroad Range dsDNA Assay Kit\nThe Accuris Broad Range Kit provides an accurate method to quantify dsDNA samples that have a broad concentration range starting at 0.2 ng\/µL. The assay kit is designed to be accurate for initial DNA sample concentrations of 0.2 to 2,000 ng\/µL, providing a detection range of 4−2,000 ng.\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2022\/08\/NS1000-Series-Literature.pdf\"\u003eBrochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2022\/08\/NS1020-Operation-Manual.pdf\"\u003eManual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Benchmark Scientific","offers":[{"title":"Default Title","offer_id":45980652077135,"sku":"NS1020-BR-100","price":0.0,"currency_code":"ILS","in_stock":true}]},{"product_id":"smartdrop-xf-nano-spectrophotometer-ns1020-e","title":"SmartDrop™ XF Nano Spectrophotometer","description":"SmartDrop L\nIdeal for basic DNA\/RNA\/protein quantification and purity\nAffordable LED and silicon detector technology\nFixed 0.5mm path length, detect up to 2500ng\/µl of dsDNA\nSmartDrop L is the affordable choice for laboratories needing to determine nucleic acid and protein concentrations and purity of samples. The LED light source and silicon photocell sensor provide readings at 260 and 280nm. Samples from 1.0 to 2.0µl are loaded directly on the pedestal. Results are provided in about 5 seconds. The software automatically\ncalculates and displays 260\/280 ratios.\n\nSmartDrop X\nFull-spectrum absorbance scans from 200 to 800nm\nQuickly calculates and displays 260\/280 and 260\/230 ratios\nLong-life Xenon lamp with precision monochromator\nAuto-ranging path lengths of 0.2mm and 1.0mm\nDetect up to 4,500 ng\/µl of dsDNA without dilution\nA full spectrum UV-Vis spectrophotometer, SmartDrop X requires 0.5 to 2.0µl of sample. In addition to nucleic acid and protein calculations, the software has preset programs for BCA, Bradford and Lowry assays. A full spectrum analysis can be performed in about 6 seconds, aiding in the\nidentification of unknowns. Up to 5 specific points on the spectrum can be selected for colorimetric readings output. The long life Xenon lamp source requires no warm up and is paired with a highly sensitive CCD detector. To provide the most accurate results, the SmartDrop X utilizes 2 path lengths.\n\nSmartDrop XF – Spectrophotometer + Fluorometer\nFull-spectrum absorbance scanning and calculations of\n260\/280 and 260\/230 ratios\nLong-life Xenon lamp with precision monochromator\nAuto-ranging path lengths of 0.05mm, 0.2mm and\n1.0mm\nDetect up to 15,000ng\/µl of dsDNA without dilution\nIntegrated fluorometer for sensitive quantitation of low\nconcentration nucleic acids\nThis top of the line spectrophotometer can perform not only UV-Vis readings in the range of 200-800nm but also fluorescence readings. Like the SmartDrop X, the SmartDrop XF features predefined programs for nucleic acids, proteins, and various colorimetric assays. The patented, motorized system gently stretches the sample column and allows for three different path lengths, providing accurate readings of samples from 0.5 to 2.0µl without dilution.\nThe integrated fluorometer yields more accurate, sensitive and selective quantitation of nucleic acids. The blue light channel (460nm) is useful for detection of dyes such as PicoGreen and RiboGreen as well as GFP and fluorescein. UV, green and red channel models are available upon\nrequest.\n\nAccuris DNA Quantification Kits\nAccuris DNA Quantification Kits are designed for accurate fluorescent quantification of dsDNA using instruments such as the Qubit®, SmartDrop™ XF, and microplate readers.  The reagents are highly selective for double-stranded DNA (dsDNA); quantification results will not be skewed by single-stranded DNA (ssDNA), RNA, protein, or nucleotides in a sample.  Included with each kit are a concentrated fluorescent assay reagent, dilution buffer, and ready-to-use DNA standards.  The assay reagent is diluted using the buffer provided, sample is added (1 µL to 20 µL), and the concentration determined using an appropriate fluorometer instrument that utilizes blue excitation (460 ± 20 nm) and measures green fluorescence (525-570 nm).\n\nHigh Sensitivity dsDNA Assay Kit\nThe Accuris High Sensitivity Kit provides an accurate method to quantify low concentration dsDNA samples.  The assay kit is designed to be accurate for initial DNA sample concentrations of 0.005–120 ng\/µl, providing a detection range of 0.1–120 ng.\n\nBroad Range dsDNA Assay Kit\nThe Accuris Broad Range Kit provides an accurate method to quantify dsDNA samples that have a broad concentration range starting at 0.2 ng\/µL. The assay kit is designed to be accurate for initial DNA sample concentrations of 0.2 to 2,000 ng\/µL, providing a detection range of 4−2,000 ng.\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable border=\"1\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e7-inch touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMinimum sample size\u003c\/th\u003e\n\u003ctd\u003e0.5µl – 2.0µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePath length\u003c\/th\u003e\n\u003ctd\u003e0.05mm, 0.2mm, 1.0mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLight source\u003c\/th\u003e\n\u003ctd\u003eXenon Flash Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetector\u003c\/th\u003e\n\u003ctd\u003e2048 Element Linear Silicon CCD Array\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWavelength\u003c\/th\u003e\n\u003ctd\u003e200 – 800nm (1nm steps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAbsorbance range\u003c\/th\u003e\n\u003ctd\u003e0.04 – 300 A (10mm equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAbsorbance precision\u003c\/th\u003e\n\u003ctd\u003e0.005 A 0.003 A 0.003 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLower limit of detection\u003c\/th\u003e\n\u003ctd\u003edsDNA: 2ng\/µl ; BSA: 0.1mg\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUpper limit of detection\u003c\/th\u003e\n\u003ctd\u003edsDNA: 15,000ng\/µl; BSA: 360mg\/ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDetection time\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 6 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCommunication ports\u003c\/th\u003e\n\u003ctd\u003eUSB for data export\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage input\u003c\/th\u003e\n\u003ctd\u003eDC 24V, 2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e25W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions (WxDxH)\u003c\/th\u003e\n\u003ctd\u003e8.2 x 12.6 x 7.3 in. \/ 20.8 x 32.0 x 18.6cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e3.6 kg \/ 7.9 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAbsorbance range\u003c\/th\u003e\n\u003ctd\u003e0.0 – 4.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAbsorbance stability\u003c\/th\u003e\n\u003ctd\u003e[0,3) ≤ 0.5%, [3,4) ≤ 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAbsorbance precision\u003c\/th\u003e\n\u003ctd\u003e[0,2) ≤ 0.005 A, [2,3) ≤ 1%, [3,4) ≤ 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExcitation\/Emission\u003c\/th\u003e\n\u003ctd\u003e460 ± 20nm \/ 525-570nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSensitivity\u003c\/th\u003e\n\u003ctd\u003edsDNA: 0.5pg\/µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLinearity\u003c\/th\u003e\n\u003ctd\u003eR² ≥ 0.995\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRepeatability\u003c\/th\u003e\n\u003ctd\u003e≤ 1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStability\u003c\/th\u003e\n\u003ctd\u003e≤ 1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2022\/08\/NS1000-Series-Literature.pdf\"\u003eBrochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2022\/08\/NS1020-Operation-Manual.pdf\"\u003eManual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Benchmark Scientific","offers":[{"title":"Default Title","offer_id":45980652208207,"sku":"NS1020-E","price":0.0,"currency_code":"ILS","in_stock":true}]},{"product_id":"high-sensitivity-dna-quantification-kit-100-assays-ns1020-hs-100","title":"High Sensitivity DNA Quantification Kit, 100 assays","description":"SmartDrop L\nIdeal for basic DNA\/RNA\/protein quantification and purity\nAffordable LED and silicon detector technology\nFixed 0.5mm path length, detect up to 2500ng\/µl of dsDNA\nSmartDrop L is the affordable choice for laboratories needing to determine nucleic acid and protein concentrations and purity of samples. The LED light source and silicon photocell sensor provide readings at 260 and 280nm. Samples from 1.0 to 2.0µl are loaded directly on the pedestal. Results are provided in about 5 seconds. The software automatically\ncalculates and displays 260\/280 ratios.\n\nSmartDrop X\nFull-spectrum absorbance scans from 200 to 800nm\nQuickly calculates and displays 260\/280 and 260\/230 ratios\nLong-life Xenon lamp with precision monochromator\nAuto-ranging path lengths of 0.2mm and 1.0mm\nDetect up to 4,500 ng\/µl of dsDNA without dilution\nA full spectrum UV-Vis spectrophotometer, SmartDrop X requires 0.5 to 2.0µl of sample. In addition to nucleic acid and protein calculations, the software has preset programs for BCA, Bradford and Lowry assays. A full spectrum analysis can be performed in about 6 seconds, aiding in the\nidentification of unknowns. Up to 5 specific points on the spectrum can be selected for colorimetric readings output. The long life Xenon lamp source requires no warm up and is paired with a highly sensitive CCD detector. To provide the most accurate results, the SmartDrop X utilizes 2 path lengths.\n\nSmartDrop XF – Spectrophotometer + Fluorometer\nFull-spectrum absorbance scanning and calculations of\n260\/280 and 260\/230 ratios\nLong-life Xenon lamp with precision monochromator\nAuto-ranging path lengths of 0.05mm, 0.2mm and\n1.0mm\nDetect up to 15,000ng\/µl of dsDNA without dilution\nIntegrated fluorometer for sensitive quantitation of low\nconcentration nucleic acids\nThis top of the line spectrophotometer can perform not only UV-Vis readings in the range of 200-800nm but also fluorescence readings. Like the SmartDrop X, the SmartDrop XF features predefined programs for nucleic acids, proteins, and various colorimetric assays. The patented, motorized system gently stretches the sample column and allows for three different path lengths, providing accurate readings of samples from 0.5 to 2.0µl without dilution.\nThe integrated fluorometer yields more accurate, sensitive and selective quantitation of nucleic acids. The blue light channel (460nm) is useful for detection of dyes such as PicoGreen and RiboGreen as well as GFP and fluorescein. UV, green and red channel models are available upon\nrequest.\n\nAccuris DNA Quantification Kits\nAccuris DNA Quantification Kits are designed for accurate fluorescent quantification of dsDNA using instruments such as the Qubit®, SmartDrop™ XF, and microplate readers.  The reagents are highly selective for double-stranded DNA (dsDNA); quantification results will not be skewed by single-stranded DNA (ssDNA), RNA, protein, or nucleotides in a sample.  Included with each kit are a concentrated fluorescent assay reagent, dilution buffer, and ready-to-use DNA standards.  The assay reagent is diluted using the buffer provided, sample is added (1 µL to 20 µL), and the concentration determined using an appropriate fluorometer instrument that utilizes blue excitation (460 ± 20 nm) and measures green fluorescence (525-570 nm).\n\nHigh Sensitivity dsDNA Assay Kit\nThe Accuris High Sensitivity Kit provides an accurate method to quantify low concentration dsDNA samples.  The assay kit is designed to be accurate for initial DNA sample concentrations of 0.005–120 ng\/µl, providing a detection range of 0.1–120 ng.\n\nBroad Range dsDNA Assay Kit\nThe Accuris Broad Range Kit provides an accurate method to quantify dsDNA samples that have a broad concentration range starting at 0.2 ng\/µL. The assay kit is designed to be accurate for initial DNA sample concentrations of 0.2 to 2,000 ng\/µL, providing a detection range of 4−2,000 ng.\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2022\/08\/NS1000-Series-Literature.pdf\"\u003eBrochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/accuris-usa.com\/wp-content\/uploads\/2022\/08\/NS1020-Operation-Manual.pdf\"\u003eManual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Benchmark Scientific","offers":[{"title":"Default Title","offer_id":45980652175439,"sku":"NS1020-HS-100","price":0.0,"currency_code":"ILS","in_stock":true}]},{"product_id":"biodrop-duo-plus-microvolume-spectrophotometer","title":"BioDrop Duo+ Microvolume Spectrophotometer","description":"\u003cp\u003eThe BioDrop Duo+ microvolume sample port uses no moving parts. This means that the instrument provides excellent reproducibility without the need for regular pathlength calibration. Measurements are also highly accurate because the pathlength of the port is highly specified to 5 µm.\u003c\/p\u003e \u003cp\u003ePre-Programmed methods on the BioDrop Duo + instruments include DNA, RNA and Oligo Concentration, Protein Assays, OD600, and an extensive menu of commonly available fluorescent dyes for nucleic acids and proteins. Should there be a method specific to your lab, this can be written in using the versatile Equation Editor. Results can be saved to the on-board memory of the BioDrop Duo+, saved to USB as a .csv file, printed to the optional integrated serial printer, or analysed in the powerful BioDrop Resolution PC Software. BioDrop Resolution CFR is also an option for those labs that are 21 CFR Part 11 compliant.\u003c\/p\u003e \u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e \u003ctd\u003eTypical Concentration\u003c\/td\u003e \u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequencing \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e125 ng\/20 μl (6 ng\/μl)\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNext Generation Sequencing \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e10 ng\/μl\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfections \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e5 to 30 μg\/100μl\u003cbr\u003e 50 to 500 ng\/μl\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDNA Vaccines\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e0.5 to 2 mg\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePCR \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e2 ng\/μl\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eqPCR \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e200 ng\/100 μl (2 ng\/μl)\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDNA Microarray \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u0026gt;2 μg\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003esiRNA \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e7.5 μg\/μ\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtein Crystallography\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e50 ng\/μl\u003c\/td\u003e \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Range:\u003c\/strong\u003e 190 - 1100 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Accuracy:\u003c\/strong\u003e ±2 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Reproducibility:\u003c\/strong\u003e ±1 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectral Bandwidth:\u003c\/strong\u003e 5 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Time:\u003c\/strong\u003e \u0026lt;4 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStray Light:\u003c\/strong\u003e \u0026lt;0.5 %T @ 220 nm NaI, \u0026lt;0.5%T @ 340 nm NaNO2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Range:\u003c\/strong\u003e 0A to 2.5A, 0 to 100%T\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Accuracy:\u003c\/strong\u003e ±0.01A + 1.5% of the reading @ 546 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Reproducibility:\u003c\/strong\u003e ±0.003A (0 to 0.5A), ±0.007A (0.5 to 1.0A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise:\u003c\/strong\u003e 0.005A peak to peak, 0.002A RMS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 120 to 240V~ 50\/60Hz, 40VA Max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 7\" Touch screen display\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLamp:\u003c\/strong\u003e Pulsed Xenon lamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLanguages:\u003c\/strong\u003e English, French, German, Spanish, Italian, Japanese, Chinese\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Volume:\u003c\/strong\u003e Minimum 0.6 µL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Ports:\u003c\/strong\u003e Standard 10x10 mm cuvette port + Microvolume port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePathlength:\u003c\/strong\u003e 10mm + 0.5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Height 190 mm x Width 280 mm x Depth 410 mm (521 mm with printer)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 3.55 kg (4 kg with printer)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware:\u003c\/strong\u003e Resolution Software (included), Resolution CFR (optional)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/sites\/default\/files\/2024-02\/Biochrom%20BioDrop%20Microvolume%20Spectrophotometers%20Brochure.pdf\"\u003eBiochrom BioDrop Microvolume Spectrophotometers Brochure.pdf\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCatalogue No.\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3006-68\u003c\/td\u003e\n\u003ctd\u003eBioDrop Duo+\u003c\/td\u003e\n\u003ctd\u003eBIODROP DUO+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3006-69\u003c\/td\u003e\n\u003ctd\u003eBioDrop Duo+ with built-in printer\u003c\/td\u003e\n\u003ctd\u003eBIODROP DUO+ WITH PRINTER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Biochrom","offers":[{"title":"BioDrop Duo+","offer_id":46498033696847,"sku":"80-3006-68","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"BioDrop Duo+ with built-in printer","offer_id":46498033729615,"sku":"80-3006-69","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/biodrop-duo-spectrophotometer-biochrom1.jpg?v=1787771291"},{"product_id":"biodrop-ulite-plus-microvolume-spectrophotometer","title":"BioDrop µLite+ Microvolume Spectrophotometer","description":"\u003cp\u003eThe BioDrop µLite+ microvolume sample port uses no moving parts. This means that the instrument provides excellent reproducibility without the need for regular pathlength calibration. Measurements are also highly accurate because the pathlength of the port is highly specified to 5 µm.\u003c\/p\u003e \u003cp\u003ePre-Programmed methods on the BioDrop µLite+ instruments include DNA, RNA and Oligo Concentration, Protein Assays, and an extensive menu of commonly available fluorescent dyes for nucleic acids and proteins. Should there be a method specific to your lab, this can be written in using the versatile Equation Editor.\u003c\/p\u003e \u003cp\u003eResults can be saved to the on-board memory of the BioDrop, saved to USB as a .csv file, printed to the optional integrated serial printer, or analysed in the powerful BioDrop Resolution PC Software. BioDrop Resolution CFR is also an option for those labs that are 21 CFR Part 11 compliant.\u003c\/p\u003e \u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e \u003ctd\u003eTypical Concentration\u003c\/td\u003e \u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSequencing \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e125 ng\/20 μl (6 ng\/μl)\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNext Generation Sequencing\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e10 ng\/μl\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransfections \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e5 to 30 μg\/100μl\u003cbr\u003e 50 to 500 ng\/μl\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePCR \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e2 ng\/μ\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eqPCR \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e200 ng\/100 μl (2 ng\/μl)\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDNA Microarray \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e\u0026gt;2 μg\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003esiRNA \u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e7.5 μg\/μ\u003c\/td\u003e \u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtein Crystallography\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e50 ng\/μl\u003c\/td\u003e \u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Time:\u003c\/strong\u003e \u0026lt;4 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Range:\u003c\/strong\u003e 190 - 1100 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Accuracy:\u003c\/strong\u003e ±2 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Reproducability:\u003c\/strong\u003e ±1 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectral Bandwidth:\u003c\/strong\u003e 5 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStray Light:\u003c\/strong\u003e \u0026lt;0.5 %T @ 220 nm NaI, \u0026lt;0.5%T @ 340 nm NaNO2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Range:\u003c\/strong\u003e 0A to 2.5A, 0 to 100%T\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Accuracy:\u003c\/strong\u003e ±0.01A + 1.5% of the reading @ 546 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Reproducability:\u003c\/strong\u003e ±0.003A (0 to 0.5A), ±0.007A(0.5 to 1.0A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise:\u003c\/strong\u003e 0.005A peak to peak, 0.002A RMS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 7\" Touch screen display\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLamp:\u003c\/strong\u003e Pulsed Xenon lamp with 3 year warranty\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLanguages:\u003c\/strong\u003e English, French, German, Spanish, Italian, Japanese, Chinese\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Volume:\u003c\/strong\u003e Minimum 0.6 µL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample ports:\u003c\/strong\u003e Microvolume port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePathlength:\u003c\/strong\u003e 0.5mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 120 to 240V~ 50\/60Hz, 40VA Max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e Height 190 mm x Width 280 mm x Depth 410 mm (521 mm with printer)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 3.55 kg (4 kg with printer)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware:\u003c\/strong\u003e Resolution Software (included), Resolution CFR (optional)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/sites\/default\/files\/2024-02\/Biochrom%20BioDrop%20Microvolume%20Spectrophotometers%20Brochure.pdf\"\u003eBiochrom BioDrop Microvolume Spectrophotometers Brochure.pdf\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCatalogue No.\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3006-55\u003c\/td\u003e\n\u003ctd\u003eBioDrop µLite+\u003c\/td\u003e\n\u003ctd\u003eBIODROP ULITE+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3006-56\u003c\/td\u003e\n\u003ctd\u003eBioDrop µLite+ with built-in printer\u003c\/td\u003e\n\u003ctd\u003eBIODROP ULITE+ WITH PRINTER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Biochrom","offers":[{"title":"BioDrop µLite+","offer_id":46498033762383,"sku":"80-3006-55","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"BioDrop µLite+ with built-in printer","offer_id":46498033795151,"sku":"80-3006-56","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/BioDrop-_CE_BCLite-spectrophotometer-biochrom.jpg?v=1787771291"},{"product_id":"biowave-3-and-3-plus-uv-visible-spectrophotometers","title":"Biowave 3 and 3+ UV-Visible Life Science Spectrophotometers","description":"\u003cp\u003e\u003cstrong\u003eFeature:\u003c\/strong\u003e\u003c\/p\u003e \u003chr\u003e\u003cul\u003e\n\u003cli\u003eSplit Beam (RBC) UV\/Vis Spectrophotometer 190-1100nm (3nm\/5nm bandwidth)\u003c\/li\u003e \u003cli\u003ePre-programmed methods for DNA, RNA, Oligos, proteins and cell density\u003c\/li\u003e \u003cli\u003eNucleic acid scans for purity checking\u003c\/li\u003e \u003cli\u003eLow volume capability with Microvolume cuvettes\u003c\/li\u003e \u003cli\u003eNovel optics with a Xenon source for long lamp lifetime and low running costs\u003c\/li\u003e \u003cli\u003eLightweight and stackable for storage\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eFlexible Data Export Options \u003c\/strong\u003e\u003c\/p\u003e \u003chr\u003e\u003cp\u003eResults may be downloaded to a USB flash drive or printed to an optional integrated graphical printer for a permanent record. Alternatively, results can be exported via a cable connection to a suitable PC running Print Via Computer (PVC) software or wireless accessory (optional).\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eComprehensive IQ\/OQ Support for your Biowave instrument: \u003c\/strong\u003e\u003c\/p\u003e \u003chr\u003e\u003cp\u003eComprehensive IQ\/OQ documentation and service support is available for our Biowave instruments allowing the qualification of wavelength accuracy, wavelength repeatability, photometric accuracy, stray light, resolution, noise, and drift.\u003c\/p\u003e \u003cp\u003eIf your lab requires IQ (Installation Qualification) and OQ (Operational Qualification), contact us to learn more.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Range:\u003c\/strong\u003e 190 to 1100 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonochromator:\u003c\/strong\u003e Flat grating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Calibration:\u003c\/strong\u003e Automatic upon switch on\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBeam Height:\u003c\/strong\u003e 15 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectral Bandwidth:\u003c\/strong\u003e 5 nm or 3 nm for ‘+’ models\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Accuracy:\u003c\/strong\u003e ±2 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Reproducibility:\u003c\/strong\u003e ±1 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Source:\u003c\/strong\u003e Xenon flash lamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetector:\u003c\/strong\u003e Twin CMOS array\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Range:\u003c\/strong\u003e 0.0 to 2.500 A, 0.3 to 100 %T\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Linearity:\u003c\/strong\u003e ±1.3 % or ±0.008 A whichever is greater at 546 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Reproducibility:\u003c\/strong\u003e ±0.002 A to 0.5 A at 546 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStray Light:\u003c\/strong\u003e \u0026lt;0.5 %T 340 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStability:\u003c\/strong\u003e ±0.01 A\/h at 340 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise:\u003c\/strong\u003e ±0.005 peak to peak ±0.002 RMS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Output:\u003c\/strong\u003e USB flash drive, PC via PVC software, Optional Wireless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Export:\u003c\/strong\u003e USB flash drive: .tsv, native PVC format PC via PVC: .csv, .emf, .xlsx, .xls, .rtf, .tsv, native PVC format\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMethod Storage:\u003c\/strong\u003e 90 with PIN number protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGraphical Display:\u003c\/strong\u003e Yes, zoom and track function\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample ID:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLanguages:\u003c\/strong\u003e English, German, French, Spanish, Italian, Japanese, Chinese\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 260 × 390 × 100 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.00 kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/sites\/default\/files\/2024-06\/Biowave%203%20and%203%2B%20UV-Visible%20Life%20Science%20Spectrophotometers.pdf\"\u003eBiowave 3 and 3+ UV-Visible Life Science Spectrophotometers.pdf\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCatalogue No.\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-32\u003c\/td\u003e\n\u003ctd\u003eBiowave 3\u003c\/td\u003e\n\u003ctd\u003eBIOWAVE 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-33\u003c\/td\u003e\n\u003ctd\u003eBiowave 3 with Printer\u003c\/td\u003e\n\u003ctd\u003eBIOWAVE 3 W\/ PRINTER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-34\u003c\/td\u003e\n\u003ctd\u003eBiowave 3 Wireless\u003c\/td\u003e\n\u003ctd\u003eBIOWAVE 3 W\/ BLUETOOTH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-35\u003c\/td\u003e\n\u003ctd\u003eBiowave 3 Wireless with Printer\u003c\/td\u003e\n\u003ctd\u003eBIOWAVE 3 W\/ BT\u0026amp;PRTBIOWAVE 3+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-37\u003c\/td\u003e\n\u003ctd\u003eBiowave 3+\u003c\/td\u003e\n\u003ctd\u003eBIOWAVE 3+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-38\u003c\/td\u003e\n\u003ctd\u003eBiowave 3+ with Printer\u003c\/td\u003e\n\u003ctd\u003eBIOWAVE 3+ W\/ PRINTER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-39\u003c\/td\u003e\n\u003ctd\u003eBiowave 3+ Wireless\u003c\/td\u003e\n\u003ctd\u003eBIOWAVE 3+ W\/ BLUETOOTH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-40\u003c\/td\u003e\n\u003ctd\u003eBiowave 3+ Wireless with Printer\u003c\/td\u003e\n\u003ctd\u003eBIOWAVE 3+ W\/ BT\u0026amp;PRT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Biochrom","offers":[{"title":"Biowave 3","offer_id":46498033926223,"sku":"80-3007-32","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biowave 3 with Printer","offer_id":46498033958991,"sku":"80-3007-33","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biowave 3 Wireless","offer_id":46498033991759,"sku":"80-3007-34","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biowave 3 Wireless with Printer","offer_id":46498034024527,"sku":"80-3007-35","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biowave 3+","offer_id":46498034057295,"sku":"80-3007-37","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biowave 3+ with Printer","offer_id":46498034090063,"sku":"80-3007-38","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biowave 3+ Wireless","offer_id":46498034122831,"sku":"80-3007-39","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biowave 3+ Wireless with Printer","offer_id":46498034155599,"sku":"80-3007-40","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/Biowave-3-and-3_-UV-Visible-Life-Science-Spectrophotometers.jpg?v=1787771295"},{"product_id":"biowave-3-plus-ct-spectrophotometer","title":"Biowave 3+ CT Spectrophotometer","description":"\u003cp\u003e\u003cstrong\u003eFlexible Data Viewing and Export Options\u003c\/strong\u003e\u003c\/p\u003e \u003chr\u003e\u003cp\u003eThe 5 inch color touch screen allows users to distinguish multiple samples by color on graph overlays and the zoom and track functions gives the ability to focus on areas of interest.\u003c\/p\u003e \u003cp\u003eResults may be downloaded to a USB flash drive in CSV file format or printed to an optional integrated graphical printer for a permanent record. Alternatively, results can be exported via a cable connection to a suitable PC running Print Via Computer (PVC) software or wireless accessory (optional).\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eComprehensive IQ\/OQ Support for your Biowave instrument:\u003c\/strong\u003e\u003c\/p\u003e \u003chr\u003e\u003cp\u003eComprehensive IQ\/OQ documentation and service support is available for our Biowave instruments allowing the qualification of wavelength accuracy, wavelength repeatability, photometric accuracy, stray light, resolution, noise, and drift.\u003c\/p\u003e \u003cp\u003eIf your lab requires IQ (Installation Qualification) and OQ (Operational Qualification), \u003ca href=\"https:\/\/www.harvardbioscience.com\/about-us\/customer-contact-form\"\u003econtact us\u003c\/a\u003e to learn more.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange:\u003c\/strong\u003e 190 to 1100 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonochromator:\u003c\/strong\u003e Flat grating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Automatic upon switch on\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBeam Height:\u003c\/strong\u003e 15 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectral Bandwidth:\u003c\/strong\u003e 3 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±2 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReproducibility:\u003c\/strong\u003e ±1 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Source:\u003c\/strong\u003e Xenon flash lamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetector:\u003c\/strong\u003e Twin CMOS array\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Range:\u003c\/strong\u003e -0.300 to 2.500 A, 0.3 to 100 %T\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Linearity:\u003c\/strong\u003e ±1.3 % or ±0.008 A whichever is greater at 546 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Reproducibility:\u003c\/strong\u003e ±0.002 A to 0.5 A at 546 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStray Light:\u003c\/strong\u003e \u0026lt;0.5 %T 340 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStability:\u003c\/strong\u003e ±0.01 A\/h at 340 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise:\u003c\/strong\u003e ±0.005 peak to peak ±0.002 RMS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Output:\u003c\/strong\u003e USB flash drive, PC via PVC software, Optional Wireless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Export:\u003c\/strong\u003e USB flash drive: .tsv, native PVC format PC via PVC: .csv, .emf, .xlsx, .xls, .rtf, .tsv, native PVC format\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMethod Storage:\u003c\/strong\u003e 90 with PIN number protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGraphical Display:\u003c\/strong\u003e Color touch screen, zoom and track function\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample ID:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLanguages:\u003c\/strong\u003e English, German, French, Spanish, Italian, Japanese, Chinese\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 260 × 390 × 100 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.00 kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/sites\/default\/files\/2024-06\/Biochrom%20Biowave%203%2B%20CT%20Color%20Touch%20Brochur.pdf\"\u003eBiochrom Biowave 3+ CT Color Touch Brochure.pdf\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCatalogue No.\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-57\u003c\/td\u003e\n\u003ctd\u003eBiowave 3+ CT\u003c\/td\u003e\n\u003ctd\u003eBIOWAVE 3+ CT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-58\u003c\/td\u003e\n\u003ctd\u003eBiowave 3+ CT with Printer\u003c\/td\u003e\n\u003ctd\u003eBIOWAVE 3+ CT W.PRINT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-59\u003c\/td\u003e\n\u003ctd\u003eBiowave 3+ CT Wireless\u003c\/td\u003e\n\u003ctd\u003eBIOWAVE 3+ CT W.BLUETOOTH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-60\u003c\/td\u003e\n\u003ctd\u003eBiowave 3+ CT Wireless with Printer\u003c\/td\u003e\n\u003ctd\u003eBIOWAVE 3+ CT W.BT \u0026amp; PRINT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Biochrom","offers":[{"title":"Biowave 3+ CT","offer_id":46498034188367,"sku":"80-3007-57","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biowave 3+ CT with Printer","offer_id":46498034221135,"sku":"80-3007-58","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biowave 3+ CT Wireless","offer_id":46498034253903,"sku":"80-3007-59","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biowave 3+ CT Wireless with Printer","offer_id":46498034286671,"sku":"80-3007-60","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/biowave-3_-CT-color-touch-spectrophotometer-biochrom_0.jpg?v=1787771295"},{"product_id":"lightwave-3-and-3-plus-spectrophotometers","title":"Lightwave 3 and 3+ Spectrophotometers","description":"\u003cp\u003e\u003cstrong\u003eFlexible data export options\u003c\/strong\u003e\u003c\/p\u003e \u003chr\u003e\u003cp\u003eAll instruments have a USB port to download result data to a flash drive in a CSV file format. Alternatively, results may be printed to an optional integrated graphical printer for a permanent record or exported via a USB cable connection to a suitable PC running Print Via Computer (PVC) software for advanced reporting and data storage or the optional wireless accessory.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Range:\u003c\/strong\u003e 190 to 1100 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonochromator:\u003c\/strong\u003e Automatic upon switch on\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBeam Height:\u003c\/strong\u003e 15 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectral Bandwidth:\u003c\/strong\u003e 5 nm or 3 nm for ‘+’ models\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Accuracy:\u003c\/strong\u003e ±2 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Reproducibility:\u003c\/strong\u003e ±1 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Source:\u003c\/strong\u003e Xenon flash lamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetector:\u003c\/strong\u003e Twin CMOS array\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Range:\u003c\/strong\u003e -0.300 to 2.500 A, 0.3 to 100 %T\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Linearity:\u003c\/strong\u003e ±1.3 % or ±0.008 A whichever is greater at 546 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Reproducibility:\u003c\/strong\u003e ±0.002 A to 0.5 A at 546 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStray Light:\u003c\/strong\u003e \u0026lt;0.5 %T 340 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStability:\u003c\/strong\u003e ±0.01 A\/h at 340 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise:\u003c\/strong\u003e ±0.005 peak to peak ±0.002 RMS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Output:\u003c\/strong\u003e USB flash drive, PC via PVC software, Optional Wireless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Export:\u003c\/strong\u003e USB flash drive: .tsv, native PVC format PC via PVC: .csv, .emf, .xlsx, .xls, .rtf, .tsv, native PVC format\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMethod Storage:\u003c\/strong\u003e 90 with PIN number protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGraphical Display:\u003c\/strong\u003e Color touch screen, zoom and track function\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample ID:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLanguages:\u003c\/strong\u003e English, German, French, Spanish, Italian, Japanese, Chinese\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 260 × 390 × 100 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.00 kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/sites\/default\/files\/2024-06\/Biochrom-Lightwave-3-and-3%2B-Brochure.pdf\"\u003eBiochrom Lightwave 3 \u0026amp; 3+ Brochure.pdf\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCatalogue No.\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-42\u003c\/td\u003e\n\u003ctd\u003eLightwave 3\u003c\/td\u003e\n\u003ctd\u003eLIGHTWAVE 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-43\u003c\/td\u003e\n\u003ctd\u003eLightwave 3 with Printer\u003c\/td\u003e\n\u003ctd\u003eLIGHTWAVE 3 W\/ PRINTER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-44\u003c\/td\u003e\n\u003ctd\u003eLightwave 3 Wireless\u003c\/td\u003e\n\u003ctd\u003eLIGHTWAVE 3 W\/ BLUETOOTH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-45\u003c\/td\u003e\n\u003ctd\u003eLightwave 3 Wireless with Printer\u003c\/td\u003e\n\u003ctd\u003eLIGHTWAVE 3 W\/ BT\u0026amp;PRT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-47\u003c\/td\u003e\n\u003ctd\u003eLightwave 3+\u003c\/td\u003e\n\u003ctd\u003eLIGHTWAVE 3+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-48\u003c\/td\u003e\n\u003ctd\u003eLightwave 3+ with Printer\u003c\/td\u003e\n\u003ctd\u003eLIGHTWAVE 3+ W\/ PRINTER\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-49\u003c\/td\u003e\n\u003ctd\u003eLightwave 3+ Wireless\u003c\/td\u003e\n\u003ctd\u003eLIGHTWAVE 3+ W\/ BLUETOOTH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-50\u003c\/td\u003e\n\u003ctd\u003eLightwave 3+ Wireless with Printer\u003c\/td\u003e\n\u003ctd\u003eLIGHTWAVE 3+ W\/ BT\u0026amp;PRT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Biochrom","offers":[{"title":"Lightwave 3","offer_id":46498034384975,"sku":"80-3007-42","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Lightwave 3 with Printer","offer_id":46498034417743,"sku":"80-3007-43","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Lightwave 3 Wireless","offer_id":46498034450511,"sku":"80-3007-44","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Lightwave 3 Wireless with Printer","offer_id":46498034483279,"sku":"80-3007-45","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Lightwave 3+","offer_id":46498034516047,"sku":"80-3007-47","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Lightwave 3+ with Printer","offer_id":46498034548815,"sku":"80-3007-48","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Lightwave 3+ Wireless","offer_id":46498034581583,"sku":"80-3007-49","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Lightwave 3+ Wireless with Printer","offer_id":46498034614351,"sku":"80-3007-50","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/Lightwave-3-and-3_-Spectrophotomete.jpg?v=1787771299"},{"product_id":"lightwave-3-plus-ct-spectrophotometer","title":"Lightwave 3+ CT Spectrophotometer","description":"\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e\n\u003cli\u003eUV\/Vis Spectrophotometer covering 190-1100 nm\u003c\/li\u003e \u003cli\u003e3 nm bandwidth\u003c\/li\u003e \u003cli\u003e5-inch color touch screen with zoom and track function\u003c\/li\u003e \u003cli\u003eAccepts 10, 20 and 40mm pathlength cuvettes\u003c\/li\u003e \u003cli\u003eIntuitive, icon-driven interface\u003c\/li\u003e \u003cli\u003eRemovable sample port for ease of cleaning\u003c\/li\u003e \u003cli\u003eCompact, and excellent value for money compared to conventional systems\u003c\/li\u003e \u003cli\u003eWavelength scanning, kinetics and concentration functionality with full graphics display\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cstrong\u003eFlexible Data Viewing and Export Options \u003c\/strong\u003e\u003c\/p\u003e \u003cp\u003eThe 5-inch color touch screen allows users to distinguish multiple samples by color on graph overlays and the zoom and track functions gives the ability to focus on areas of interest.\u003c\/p\u003e \u003cp\u003eAll instruments have a USB port to download result data in CSV file format to a flash drive. Alternatively, results may be printed to an optional integrated graphical printer for a permanent record or exported via a USB cable connection to a suitable PC running Print Via Computer (PVC) software for advanced reporting and data storage or the optional wireless accessory.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Range:\u003c\/strong\u003e 190 to 1100 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonochromator:\u003c\/strong\u003e Flat grating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Calibration:\u003c\/strong\u003e Automatic upon switch on\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBeam Height:\u003c\/strong\u003e 15 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectral Bandwidth:\u003c\/strong\u003e 3 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Accuracy:\u003c\/strong\u003e ±2 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Reproducibility:\u003c\/strong\u003e ±1 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Source:\u003c\/strong\u003e Xenon flash lamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetector:\u003c\/strong\u003e Twin CMOS array\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Range:\u003c\/strong\u003e -0.300 to 2.500 A, 0.3 to 100 %T\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Linearity:\u003c\/strong\u003e ±1.3 % or ±0.008 A whichever is greater at 546 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Reproducibility:\u003c\/strong\u003e ±0.002 A to 0.5 A at 546 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStray Light:\u003c\/strong\u003e \u0026lt;0.5 %T 340 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStability:\u003c\/strong\u003e ±0.01 A\/h at 340 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise:\u003c\/strong\u003e ±0.005 peak to peak ±0.002 RMS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Output:\u003c\/strong\u003e USB flash drive, PC via PVC software, Optional Wireless\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Export:\u003c\/strong\u003e USB flash drive: .tsv, native PVC format PC via PVC: .csv, .emf, .xlsx, .xls, .rtf, .tsv, native PVC format\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMethod Storage:\u003c\/strong\u003e 90 with PIN number protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGraphical Display:\u003c\/strong\u003e Color touch screen, zoom and track function\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample ID:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLanguages:\u003c\/strong\u003e English, German, French, Spanish, Italian, Japanese, Chinese\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 260 × 390 × 100 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.00 kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/sites\/default\/files\/2024-06\/Biochrom%20Lightwave%203%2B%20CT%20Color%20Touch%20Brochure.pdf\"\u003eBiochrom Lightwave 3+ CT Color Touch Brochure.pdf\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCatalogue No.\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-67\u003c\/td\u003e\n\u003ctd\u003eLightwave 3+ CT\u003c\/td\u003e\n\u003ctd\u003eLIGHTWAVE 3+ CT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-68\u003c\/td\u003e\n\u003ctd\u003eLightwave 3+ CT with Printer\u003c\/td\u003e\n\u003ctd\u003eLIGHTWAVE 3+ CT W.PRINT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-69\u003c\/td\u003e\n\u003ctd\u003eLightwave 3+ CT Wireless\u003c\/td\u003e\n\u003ctd\u003eLIGHTWAVE 3+ CT W.BLUETOOTH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e80-3007-70\u003c\/td\u003e\n\u003ctd\u003eLightwave 3+ CT Wireless with Printer\u003c\/td\u003e\n\u003ctd\u003eLIGHTWAVE 3+ CT W.BT\u0026amp;PRNT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Biochrom","offers":[{"title":"Lightwave 3+ CT","offer_id":46498034647119,"sku":"80-3007-67","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Lightwave 3+ CT with Printer","offer_id":46498034679887,"sku":"80-3007-68","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Lightwave 3+ CT Wireless","offer_id":46498034712655,"sku":"80-3007-69","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Lightwave 3+ CT Wireless with Printer","offer_id":46498034745423,"sku":"80-3007-70","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/Biochrom-WPA-Lightwave-3_-CT-Color-Touch-spectrophotometer-brochure.jpg?v=1787771299"},{"product_id":"ultrospec-30-cell-density-meter","title":"Ultrospec 30 Cell Density Meter","description":"\u003cp\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCreation of Standard Curves\u003c\/strong\u003e: Generate and save cell and condition specific standard curves using absorbance values or McFarland standards to use for future quantification.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eCompact and Portable\u003c\/strong\u003e: Hand-held instrument with rechargeable battery for easy movement around the lab.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eTouchscreen Display\u003c\/strong\u003e: Intuitive menu arrangement easily navigated using the colour trouchscreen.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eInstrument Data Output\u003c\/strong\u003e: Measurement data can be exported to a USB flash drive as common-separated value (.csv).\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 80-3008-12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Range:\u003c\/strong\u003e 600 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Source:\u003c\/strong\u003e LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetector:\u003c\/strong\u003e Photo Diode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 4.3-inch, 480 x 272-pixel resolution backlit LCD colour display\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Conditions:\u003c\/strong\u003e -10 ̊C to 70 ̊C (14 ̊F to 158 ̊F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectral Bandwidth:\u003c\/strong\u003e 40nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Range:\u003c\/strong\u003e Absorbance 0.0 to 2.5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Accuracy:\u003c\/strong\u003e \u0026lt; ± 0.05A 1A using neutral density filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Repeatability:\u003c\/strong\u003e ± 0.02A at 1A om 10mm cuvette\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Holder:\u003c\/strong\u003e Accepts: 10mm x 10mm cuvettes 16mm test tubes Can accept 10-12mm tubes with optional adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Connector: USB-A:\u003c\/strong\u003e Interface for memory device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connector: USB-C:\u003c\/strong\u003e Input power at 5V, 2 Amp max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower (via external charger):\u003c\/strong\u003e USB charger specifications (included): 100-240V, 50\/60Hz, 10W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery:\u003c\/strong\u003e Internal rechargeable Li-Ion battery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e CE \u0026amp; UKCA marked, US\/CAN safety (ETL or equivalent)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 170mm W x 210 mm D x 50 mm H\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.6 kg (1.3 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/sites\/default\/files\/2025-05\/25_Biochrom_Ultrospec_30_Cell_Density_Meter_Flyer_v4_Digital.pdf\"\u003eBiochrom Ultrospec 30.pdf\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCatalogue No.\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e80-3008-12\u003c\/td\u003e\n\u003ctd\u003eUltrospec 30 Cell Density Meter\u003c\/td\u003e\n\u003ctd\u003eU30 CELL DENSITY METER II\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Biochrom","offers":[{"title":"Default Title","offer_id":46498034876495,"sku":"80-3008-12","price":9358.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/Biochrom-Ultrospec-30-Cell-Density-Meter_pic2.jpg?v=1787771302"},{"product_id":"ultrospec-7500-uv-vis-spectrophotometer","title":"Ultrospec 7500 UV-Vis Spectrophotometer","description":"\u003cp\u003e\u003cstrong\u003eEnergy-efficient touchscreen display.\u003c\/strong\u003e\u003c\/p\u003e \u003chr\u003e\u003cp\u003eThe system includes an intuitive, easy-to-use, 800×480-pixel backlit color LCD display with touch panel navigation of the instrument’s built-in firmware. When the display is off, the only power consumed is by the touch screen controller. The instrument exits sleep mode with a touch of the screen. Easier on you, and easier on the planet.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDependable and built to last.\u003c\/strong\u003e\u003c\/p\u003e \u003chr\u003e\u003cp\u003eThere’s a reason Biochrom is one of the world’s leading spectrophotometry brands: some of our customers have been using the same machine for over 20 years. No planned obsolescence here. Our level of quality, dependability, and customer service is completely unmatched.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eIQ\/OQ\/PQ compliance available \u003c\/strong\u003e\u003c\/p\u003e \u003chr\u003e\u003cp\u003eIf your lab requires IQ (Installation Qualification), OQ (Operation Qualification), or PQ (Performance Qualification) compliance, your Ultrospec 7500 can be customized to meet your needs. \u003ca href=\"https:\/\/www.harvardbioscience.com\/about-us\/customer-contact-form\"\u003eContact us \u003c\/a\u003eto learn more.\u003c\/p\u003e \u003cp\u003e21 CFR Part 11-compliant software is also available.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eAll the accessories (and flexibility) you need.\u003c\/strong\u003e\u003c\/p\u003e \u003chr\u003e\u003cp\u003eLooking for one spectrophotometer that does it all? If your lab has unique needs, the optional accessories can help you customize your Ultrospec 7500 to suit them.\u003c\/p\u003e \u003cul\u003e\n\u003cli\u003ePrinters\u003c\/li\u003e \u003cli\u003eSippers\u003c\/li\u003e \u003cli\u003eHeating\u003c\/li\u003e \u003cli\u003eVarious cell accessories\u003c\/li\u003e \u003cli\u003eAnd more.\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cbr\u003e \u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Range:\u003c\/strong\u003e 190 to 1100 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonochromator:\u003c\/strong\u003e 1200 lines\/mm Aberration corrected concave grating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Calibration:\u003c\/strong\u003e Automatic upon switch on\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBeam Height:\u003c\/strong\u003e 15 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectral Bandwidth:\u003c\/strong\u003e \u0026lt;2 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Accuracy:\u003c\/strong\u003e ±1 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Reproducibility:\u003c\/strong\u003e ±0.5 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Sources:\u003c\/strong\u003e Xenon flash lamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetector:\u003c\/strong\u003e Two silicon photodiodes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Range:\u003c\/strong\u003e -3.000 to 3.000 A, 0.1 to 100000 %T\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Accuracy:\u003c\/strong\u003e ±0.5 % or ±0.003 A whichever is greater at 546 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Reproducibility:\u003c\/strong\u003e ±0.5 % to 3.000 A at 546 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStray Light:\u003c\/strong\u003e \u0026lt;0.05 %T at 220 nm using NaI or at 340 nm using NaNO2 , \u0026lt;0.10 %T at 380 using NaNO2 ±0.01 A\/h at 340 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStability:\u003c\/strong\u003e ±0.001 A\/h at 340 nm for 0 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise:\u003c\/strong\u003e ±0.002 peak to peak ± 0.0005 RMS at 340 nm for 0 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Output:\u003c\/strong\u003e USB Flash Drive, PC via PVC software, Optional Bluetooth\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Export:\u003c\/strong\u003e USB Flash Drive: .tsv, native PVC format\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMethod Storage:\u003c\/strong\u003e 156 with PIN number protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGraphical Display:\u003c\/strong\u003e Yes, zoom and track function\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample ID:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLanguages:\u003c\/strong\u003e English, German, French, Spanish, Italian, Japanese, Chinese\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 510 × 350 × 160 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 13.00 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Input:\u003c\/strong\u003e 19 VDC at max 90 VA from a supplied 100 to 240 V~, 50\/60 Hz Mains Power Adapter\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/sites\/default\/files\/2025-08\/Biochrom_Ultrospec%207500%20Brochure.pdf\"\u003eBiochrom Ultrospec 7500 Brochure .pdf\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/products\/biochrom\/spectrophotometers\/resolution-spectrophotometer-pc-software\"\u003eResolution An easy to use software platform with powerful modules for measurement and analysis.\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCatalogue No.\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e80-2140-60\u003c\/td\u003e\n\u003ctd\u003eUltrospec 7500 UV-Vis Spectrophotometer\u003c\/td\u003e\n\u003ctd\u003eULTROSPEC 7500\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Biochrom","offers":[{"title":"Default Title","offer_id":46498034909263,"sku":"80-2140-60","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/Biochrom_7500_open-image.jpg?v=1787771303"},{"product_id":"ultrospec-35c-colorimeter","title":"Ultrospec 35c Colorimeter","description":"\u003cp\u003e\u003cstrong\u003eKey features:\u003c\/strong\u003e\u003c\/p\u003e \u003cul\u003e\n\u003cli\u003eFlexible analysis: Measures samples in absorbance and % Transmission modes as well as having simple kinetics functionality.\u003c\/li\u003e \u003cli\u003eRobust LED light source: User-selectable wavelengths: 450, 500, 520, 540, 600 and 640 nm.\u003c\/li\u003e \u003cli\u003eTouchscreen display: The instrument has a 4.3’’ color touchscreen for easy workflow.\u003c\/li\u003e \u003cli\u003eInstrument data output: Measurement data can be exported to a USB flash drive as comma-separated values (.csv).\u003c\/li\u003e \u003cli\u003eVersatile and portable: The instrument has a small footprint allowing it to be operated as a handheld battery powered unit or connected to mains power on your benchtop. It is easy to clean and requires very minimal maintenance.\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 80-3008-11\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength Range:\u003c\/strong\u003e 450 to 640 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight Source:\u003c\/strong\u003e LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED array wavelengths:\u003c\/strong\u003e 450 nm, 500 nm, 520 nm, 540 nm, 600 nm, 640 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetector:\u003c\/strong\u003e Photo Diode\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 480 x 272-pixel resolution backlit LCD color display\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Conditions:\u003c\/strong\u003e -10 ̊C to 70 ̊C (14 ̊F to 158 ̊F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpectral Bandwidth:\u003c\/strong\u003e 40nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Range:\u003c\/strong\u003e Absorbance 0.0 to 2.5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Accuracy:\u003c\/strong\u003e \u0026lt; ± 0.05A 1A using neutral density filter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhotometric Repeatability:\u003c\/strong\u003e ± 0.02A at 1A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperation Modes:\u003c\/strong\u003e Absorbance, Transmission, Kinetics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample Holder:\u003c\/strong\u003e Accepts: • 10mm x 10mm cuvettes • 16mm test tubes Can accept 10-12mm tubes with optional adapter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Connector: USB-A:\u003c\/strong\u003e Interface for memory device\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Connector: USB-C:\u003c\/strong\u003e Input power at 5V, 2 Amp max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower (via external charger):\u003c\/strong\u003e USB charger specifications (included): 100-240V, 50\/60Hz, 10W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery:\u003c\/strong\u003e Internal rechargeable Li-Ion battery\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e CE \u0026amp; UKCA marked, US\/CAN safety (ETL or equivalent)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 170mm W x 210 mm D x 50 mm H\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.6 kg (1.3 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/www.harvardbioscience.com\/sites\/default\/files\/2025-05\/25_Biochrom_Ultrospec_35c_Colorimeter_Flyer_v4_Digital.pdf\"\u003eBiochrom Ultrospec 35c.pdf\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCatalogue No.\u003c\/th\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e80-3008-11\u003c\/td\u003e\n\u003ctd\u003eUltrospec 35c Colorimeter\u003c\/td\u003e\n\u003ctd\u003eU35C COLORIMETER II\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Biochrom","offers":[{"title":"Default Title","offer_id":46498035073103,"sku":"80-3008-11","price":8911.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/biochrom-ultrospec-35c-colorimeter---harvard-bioscience---pic1.jpg?v=1787771306"},{"product_id":"nano-spectrophotometer-drop-and-cuvette-uv-vis-system-76777-152","title":"Nano Spectrophotometer, Drop and Cuvette UV-Vis System","description":"\u003cp\u003eFast UV-Vis quantification and purity analysis with microvolume pedestal measurement, cuvette capability, and guided stand-alone operation for molecular biology workflows.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUses as little as 0,5 µl of sample for nucleic acid and protein quantification\u003c\/li\u003e\n\u003cli\u003eAuto-adjusting pathlengths of 0,2 and 1,0 mm help support accurate concentration calculations\u003c\/li\u003e\n\u003cli\u003ePreset programs support nucleic acids, proteins, colourimetric assays, UV-Vis scans, and OD 600 measurements\u003c\/li\u003e\n\u003cli\u003eLong-life xenon lamp and silicon CCD detector provide fast spectral scanning from 200 to 800 nm\u003c\/li\u003e\n\u003cli\u003eBuilt-in printer, internal memory, and USB export support flexible result handling\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe VWR® Nano Spectrophotometer helps users rapidly check DNA, RNA, and protein concentration and purity, with 260\/280 and 260\/230 absorbance ratios calculated and displayed for quick review.\u003c\/p\u003e\u003cp\u003eA small sample droplet is placed directly onto the quartz pedestal, after which the upper arm is lowered to form a liquid column for measurement. The instrument automatically adjusts the optical pathlength between 0,2 and 1 mm to ensure accurate concentration calculations across a wide measurement range. DNA, RNA, and protein concentrations, as well as sample purity, are determined within seconds and displayed on the integrated touchscreen.\u003c\/p\u003e\u003cp\u003eThe full-colour, 17,8 cm touchscreen and Protocol Guidance software walk users through common methods, while stand-alone instrument control reduces the need for a separate computer during routine measurements. The cuvette port behind the quartz pedestal supports OD 600 readings for applications such as bacterial culture growth measurements, and two glass cuvettes are included.\u003c\/p\u003e\u003cp\u003eCE and UKCA marked.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDelivery:\u003c\/strong\u003e Supplied with software, EU plug and UK plug, and 2 glass cuvettes.\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight source:\u003c\/strong\u003e Pulsed xenon flash lamp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetector:\u003c\/strong\u003e 2048 Element linear silicone CCD array\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsorbance range:\u003c\/strong\u003e Pedestal: 0,04 - 90 A, Cuvette: 0 - 4 A (10 mm equivalent)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsorbance accuracy:\u003c\/strong\u003e 1% (7,332 Abs at 260 nm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConcentration:\u003c\/strong\u003e Maximum: dsDNA: 4500 ng\/µl, BSA: 135 mg\/ml Lower limit of detection: dsDNA: 2 ng\/µl, BSA: 0,1 mg\/ml\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput:\u003c\/strong\u003e USB and printer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample size:\u003c\/strong\u003e 0,5 - 2,0 µl\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWavelength accuracy:\u003c\/strong\u003e ±1 nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e 240 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 2,8 kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.avantorsciences.com\/adaptivemedia\/rendition\/id_7bc2d1bbc81a5ad61272ab9589cd24a48f03d80e\/vid_829a3432e5594193f2ff7c92f935a082d4c2acce\/prid_original\/clid_SAPDAM\" target=\"_blank\" rel=\"noopener\"\u003eManual VWR Nano Spectrophotometer\u003c\/a\u003e (Manual)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.avantorsciences.com\/adaptivemedia\/rendition\/id_2018c9aaff1838cdae6a3d9f3794087afdf0d582\/vid_b47bce25ddde249ae1fc22cf39f246fd7c1614fa\/prid_original\/clid_SAPDAM\" target=\"_blank\" rel=\"noopener\"\u003eManual VWR® Nano Spectrophotometer\u003c\/a\u003e (Manual)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.avantorsciences.com\/adaptivemedia\/rendition\/id_d20832c751a46f96c92a9bf377778e3aabaa1f44\/vid_36f3c37b407af3fce64699e55ffd261e790b1a5b\/prid_original\/clid_SAPDAM\" target=\"_blank\" rel=\"noopener\"\u003eManual VWR® Nano Spectrophotometer, 200 - 800 nm\u003c\/a\u003e (Manual)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.avantorsciences.com\/adaptivemedia\/rendition\/id_0eb233d584fbf433b231954c08044ceac9a1498d\/vid_5b8ea21e858780b0b2ae079081211a555e1399fc\/prid_original\/clid_SAPDAM\" target=\"_blank\" rel=\"noopener\"\u003eVWR® Nano Spectrophotometer\u003c\/a\u003e (Brochure)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003ePack\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e76777-152\u003c\/td\u003e\n\u003ctd\u003eEU\/UK plug\u003c\/td\u003e\n\u003ctd\u003eVWR® Nano spectrophotometer, EU\/UK plug\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"VWR","offers":[{"title":"Default Title","offer_id":46772341047375,"sku":"76777-152","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/clid_SAPDAM_72f48519-44ae-4057-9c8d-3982ccf3b39a.jpg?v=1789394191"},{"product_id":"fluorometer-210-000157","title":"Fluorometer","description":"\u003cp\u003eVWR® Fluorometer for quantitation of DNA, RNA, and Proteins. Compact with touch screen control panel. Compatible with VWR® quantitation kits and kits from leading suppliers.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSensitive quantitation down to 0.1 pg\/µl ds DNA\u003c\/li\u003e\n\u003cli\u003eLarge color touch screen for programming and operation\u003c\/li\u003e\n\u003cli\u003eTwo models for single or eight-sample processing\u003c\/li\u003e\n\u003cli\u003eBuilt-in reagent calculators for sample preparation\u003c\/li\u003e\n\u003cli\u003eCompact and portable (11×6\" footprint)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eSample volume: 1 to 20 µl\u003cbr\u003e\nCompatible sample tubes: 0.5 ml transparent thin wall PCR tube\u003cbr\u003e\nLinearity range: Five orders of magnitude\u003cbr\u003e\nSensitivity: dsDNA: 0.01 ng\/µl, ssDNA: 0.05 ng\/µl, RNA: 0.25 ng\/µl, microRNA: 0.05 ng\/µl\u003cbr\u003e\nCalibration: 2 or 3 points\u003cbr\u003e\nControl panel: 5\" color touch screen\u003cbr\u003e\nWorking environment: 15 to 30 ℃, \u0026lt;75% RH, indoor use\u003c\/p\u003e\u003cp\u003e\u003cspan style=\"color:black\"\u003eMeets ASTM standards. EN-342.\u003c\/span\u003e\u003c\/p\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight source:\u003c\/strong\u003e LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetector:\u003c\/strong\u003e Silicon photomultiplier\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample handling:\u003c\/strong\u003e 1 (sample throughput)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScanning speed:\u003c\/strong\u003e ≤5 s\/sample\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e 100 - 240 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eW×D×H:\u003c\/strong\u003e 10.8×24.1×5.7 cm (4.25×9.5×2.25\")\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.5 kg (1.1 lbs.)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.avantorsciences.com\/adaptivemedia\/rendition\/id_56cd3ff6ef52a6584319bd3d260dd7c0a819e0f9\/vid_56cd3ff6ef52a6584319bd3d260dd7c0a819e0f9\/prid_original\/clid_SAPDAM\" target=\"_blank\" rel=\"noopener\"\u003eManual VWR® Fluorometer\u003c\/a\u003e (Manual)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/digitalassets.avantorsciences.com\/adaptivemedia\/rendition\/id_be4c87f3bd5215a67038e6061c8836d15c366da1\/vid_be4c87f3bd5215a67038e6061c8836d15c366da1\/prid_original\/clid_SAPDAM\" target=\"_blank\" rel=\"noopener\"\u003eVWR Fluorometer\u003c\/a\u003e (Brochure)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003ePack\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e210-000157\u003c\/td\u003e\n\u003ctd\u003e100 - 240 VAC\u003c\/td\u003e\n\u003ctd\u003eVWR® Fluorometer, 100 - 240 VAC\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"VWR","offers":[{"title":"Default Title","offer_id":46772341637199,"sku":"210-000157","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/clid_SAPDAM_796e139f-d1e8-4e22-bb2f-aa184ae78655.jpg?v=1789394196"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/collections\/biodrop-duo-spectrophotometer-biochrom1.jpg?v=1790864712","url":"https:\/\/www.danyel.co.il\/collections\/spectrophotometers-and-fluorometers.oembed","provider":"danyel biotech","version":"1.0","type":"link"}