{"title":"Sebia","description":"\u003cp\u003eSebia is the world's leading provider of clinical protein electrophoresis equipment and reagents — CAPILLARYS 3 and MINICAP capillary electrophoresis analyzers, the HYDRASYS 2 gel electrophoresis system, and IVD kits for multiple myeloma, diabetes (HbA1c), hemoglobin disorders, alcohol abuse (CDT), CNS inflammatory disease, alpha-1 antitrypsin deficiency and von Willebrand disease. Danyel Biotech is the distributor of Sebia in Israel.\u003c\/p\u003e","products":[{"product_id":"minicap-flex-piercing-compact-capillary-electrophoresis-analyzer-1232","title":"MINICAP FLEX-PIERCING Compact Capillary Electrophoresis Analyzer","description":"\u003cp\u003e\u003cstrong\u003eThe compact and affordable automation of Capillary Electrophoresis.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe MINICAP FLEX-PIERCING instrument offers flexibility for small size laboratories. The fully automated instrument meets the needs of the laboratory while providing clear-cut and precise separations utilizing capillary electrophoresis technology. This multi-parameter, compact, automated capillary electrophoresis instrument offers a comprehensive menu on serum and whole blood for Protein, Immunotyping, HbA1c, Hemoglobin and CDT (Carbohydrate Deficient Transferrin) testing.\u003c\/p\u003e \u003cp\u003eFor whole blood testing, the capped tubes are gently inverted to ensure adequate mixing of the samples providing accurate results. The instrument provides complete walk-away automation reducing overall labor requirements.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact automated capillary electrophoresis:\u003c\/strong\u003e Sebia condensed its experience in a compact and fully featured instrument, with the same resolution as its CAPILLARYS instruments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact but generous:\u003c\/strong\u003e 7 capillary electrophoresis techniques available on this compact platform.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Menu\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eSerum Protein Electrophoresis (SPE)\u003c\/li\u003e \u003cli\u003eSerum Immunotyping\u003c\/li\u003e \u003cli\u003eHb A1c (venous blood)\u003c\/li\u003e \u003cli\u003eHemoglobin Electrophoresis (adult blood)\u003c\/li\u003e \u003cli\u003eCDT \u0026amp; CDT\u003csub\u003eIFCC\u003c\/sub\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eSample types: whole blood, serum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThis compact bench instrument can process up to 28 samples in one go (26 on HbA1c, Hb and CDT), fully automated and allowing continuous loading.\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTest\u003c\/th\u003e\n\u003cth\u003eThroughput (tests\/hour)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROTEIN(E) 6 (serum) 20\u003c\/td\u003e\n\u003ctd\u003e84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIMMUNOTYPING (serum) 1.7\u003c\/td\u003e\n\u003ctd\u003e988\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHb A1c 7\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHEMOGLOBIN(E) 7\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCDT 10\u003c\/td\u003e\n\u003ctd\u003e168\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e* Using Software version 9.30\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReagent and consumables\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eBarcoded reagents and controls\u003c\/li\u003e \u003cli\u003eQuality control position\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eErgonomics\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eOne workstation to pilot the instrument and manage results\u003c\/li\u003e \u003cli\u003eBarcoded rotating sampler\u003c\/li\u003e \u003cli\u003eSampling from open and capped tubes (cap piercing)\u003c\/li\u003e \u003cli\u003eEfficient mixing system with multiple sample inversions\u003c\/li\u003e \u003cli\u003eDedicated workstation to both pilot the instrument and manage results\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e1232\u003c\/td\u003e\n\u003ctd\u003eMINICAP FLEX PIERCING\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"Default Title","offer_id":67629798326351,"sku":"1232","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/MINICAP_web.1.2-1.webp?v=1791284860"},{"product_id":"hydrasys-2-scan-focusing-agarose-gel-electrophoresis-analyzer-1202","title":"HYDRASYS 2 SCAN FOCUSING Agarose Gel Electrophoresis Analyzer","description":"\u003cp\u003e\u003cstrong\u003eLarge menu with high quality results on gel electrophoresis.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eHYDRASYS 2 SCAN FOCUSING is the “all-in-one” analyser for gel electrophoresis. The system offers analytical solutions for a high level of performance, matching clinical diagnostic requirements.\u003c\/p\u003e \u003cp\u003eThe analyser carries out electrophoresis steps, from sample application to final reading. It is a fast and easy to operate instrument, offering a comprehensive test menu of more than 60 HYDRAGEL programs.\u003c\/p\u003e \u003cp\u003eHYDRASYS 2 SCAN FOCUSING when coupled with the ASSIST is designed to accomodate all workflow requirements; by automating sample preparation to ensure standardisation and traceability.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Quality Results:\u003c\/strong\u003e Have confidence when reporting your patients’ results with best-in-class gel electrophoresis assays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Functional Analyzer:\u003c\/strong\u003e Ability to migrate, stain, \u0026amp; scan gels on one system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowerful Software Solution:\u003c\/strong\u003e PHORESIS Core Software provides tools for interpretation, data \u0026amp; result management and networking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorkflow \u0026amp; Traceability:\u003c\/strong\u003e Automation and standardization of samples preparation with ASSIST.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Menu\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eSerum \u0026amp; Urine Protein Electrophoresis (SPE\/UPE)\u003c\/li\u003e \u003cli\u003eSerum \u0026amp; Urine Immunofixation (IFE, Bence Jones)\u003c\/li\u003e \u003cli\u003eHYDRASHIFT daratumumab\/isatuximab\u003c\/li\u003e \u003cli\u003eCSF and Alpha-1 Antitrypsin by Isofocusing\u003c\/li\u003e \u003cli\u003evon Willebrand Multimers\u003c\/li\u003e \u003cli\u003eIso-Enzymes, B2 transferrin, LDL\/HDL cholesterol, lipoproteins\u003c\/li\u003e \u003cli\u003eHemoglobin Electrophoresis\u003c\/li\u003e \u003cli\u003eAPO E by isofocusing for research use only\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eSample types: Serum, urine, plasma CSF, whole blood\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTest\u003c\/th\u003e\n\u003cth\u003eThroughput (tests\/hour)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cul\u003e \u003cli\u003eFrom 1 to 54 samples per gel\u003c\/li\u003e \u003cli\u003eUp to 3 gels simultaneously (migration, staining and reading)\u003c\/li\u003e \u003cli\u003eOptimized scan reading (precise quantification of all fractions)\u003c\/li\u003e \u003c\/ul\u003e  \u003cul\u003e \u003cli\u003eProteins: up to 108 tests\/hour\u003c\/li\u003e \u003cli\u003eImmunofixations: up to 17 tests\/hour with the IF program\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eReagent and consumables\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003e2 sizes of gel\u003c\/li\u003e \u003cli\u003eStaining reagents on board\u003c\/li\u003e \u003cli\u003eDisposable microporous applicators with 6, 7, 15 \u0026amp; 18 wells to be used to run 1 IF or up to 54 samples in protein electrophoresis\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eErgonomics\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eSmall footprint\u003c\/li\u003e \u003cli\u003ePeltier based temperature control device for fast and accurate temperature regulation\u003c\/li\u003e \u003cli\u003eSimple flexible programming through LCD touch screen interface\u003c\/li\u003e \u003cli\u003e\u0026gt; 60 optimized migration programs\u003c\/li\u003e \u003cli\u003e10 staining\/washing programs\u003c\/li\u003e \u003cli\u003eEasy maintenance\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e1202\u003c\/td\u003e\n\u003ctd\u003eHYDRASYS 2 SCAN FOCUSING\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"Default Title","offer_id":67629798260815,"sku":"1202","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/H2S_web.1.webp?v=1791284860"},{"product_id":"capillarys-3-dbs-capillary-electrophoresis-analyzer-for-newborn-screening-dried-blood-spots-1244","title":"CAPILLARYS 3 DBS Capillary Electrophoresis Analyzer for Newborn Screening (Dried Blood Spots)","description":"\u003cp\u003e\u003cstrong\u003eThe high throughput solution for newborn hemoglobin disorders screening.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCapillary electrophoresis is a proven technology for hemoglobin disorders screening and provides high quality results.\u003cbr\u003e Sebia CAPILLARYS 3 DBS is the latest generation of instrument dedicated to newborn hemoglobin screening, offering a smooth workflow and excellent analytical features.\u003c\/p\u003e \u003cp\u003eThe CAPILLARYS 3 DBS instrument is an automated, multitasking capillary electrophoresis instrument using 12 capillaries for multiple simultaneous hands-free electrophoretic separations at high throughput.\u003c\/p\u003e \u003cp\u003eThe CAPILLARYS 3 DBS enables the analysis of samples from microplate wells and provides fully automated electrophoresis separation, from the dried blood spots on filter paper (Guthrie card) through to the final electrophoretic pattern: sample identification, sample dilution, sample incubation, capillary washing, sample injection into the capillaries, migration, detection, processing of the results, and transfer over the computer interface.\u003c\/p\u003e \u003cp\u003eThis instrument is an interesting alternative to commonly used technology such as IEF and HPLC for all the laboratories involved in newborn hemoglobin screening, bringing seamless sample traceability, high quality results, and high throughput while offering a reduced hands-on time.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh throughput instrument:\u003c\/strong\u003e Up to 70 samples\/hour, enabling Newborn Screening laboratories to cope with their workload and deliver results to pathologists and clinicians quickly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull traceability:\u003c\/strong\u003e From sample punch to result, there is no interruption in the traceability chain, preventing transcription mistakes (e.g. errors from manually entering the sample ID into the analysis software).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh autonomy:\u003c\/strong\u003e 8 full 96-well microplates could be analysed in a single run, without any reagent refill – This saves hands on time and lets the lab staff focus on important tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Reagent Control:\u003c\/strong\u003e RFID tags for all reagents and Hb AF Control ensure a smooth and efficient reagent management, reducing user intervention.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Menu\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eHb Neonat technique\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eSample types: dried blood spot (3.2mm)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eWith 12 capillaries in parallel, the CAPILLARYS 3 DBS can process a large number of samples and can analyse up to eight 96-well microplates without reagent refill.\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTest\u003c\/th\u003e\n\u003cth\u003eThroughput (tests\/hour)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eCAPI 3 NEONAT Hb\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e* Using PHORESIS Software version 9.40 D\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReagent and consumables\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eFlexible positions for reagents allow for the optimisation of on-board reagent management\u003c\/li\u003e \u003cli\u003eRFID identification for all reagents (reagent type, lot number, expiration date, volume) allows comprehensive traceability throughout workflow\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eErgonomics\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eEmbedded user interface with a touch screen\u003c\/li\u003e \u003cli\u003eAutomatic start-up and shutdown\u003c\/li\u003e \u003cli\u003eVisual alarms (with instrument notifications)\u003c\/li\u003e \u003cli\u003eA dedicated workstation pilots the instrument and manages results\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e1244\u003c\/td\u003e\n\u003ctd\u003eCAPILLARYS 3 DBS\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"Default Title","offer_id":67629798588495,"sku":"1244","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/C3_DBS_Website.2.webp?v=1791284865"},{"product_id":"capillarys-3-octa-capillary-electrophoresis-analyzer-1245","title":"CAPILLARYS 3 OCTA Capillary Electrophoresis Analyzer","description":"\u003cp\u003e\u003cstrong\u003eEvolution makes the difference.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe CAPILLARYS 3 OCTA is the most recent Sebia automated capillary electrophoresis system.\u003c\/p\u003e \u003cp\u003eThe CAPILLARYS 3 OCTA has the great heritage of CAPILLARYS 2 FLEX-PIERCING, with countless enhancements, based on the same technology as CAPILLARYS 3 TERA.\u003c\/p\u003e \u003cp\u003eThe CAPILLARYS 3 OCTA offers a broad assay menu in myeloma, diabetes, hemoglobinopathies and chronic alcohol abuse.\u003c\/p\u003e \u003cp\u003eThe CAPILLARYS 3 OCTA shares the same reagent and consumables as the other CAPILLARYS 3 instruments, allowing the lab to adopt the most relevant platforms, mixing CAPILLARYS 3 OCTA, TERA, TERA TLA and TERA MC configurations to match exactly the needs of their organization. This flexibility also allows the lab to evolve easily by scaling up the Sebia solution.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible platform:\u003c\/strong\u003e CAPILLARYS 3 can run up to 7 techniques, automated technique changes are enabled via pre-set switch racks, which allows users to load up to 120 samples with diverse tests simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable solution:\u003c\/strong\u003e Sharing the same technical platform and reagent line, laboratories can mix the different CAPILLARYS 3 platforms to meet their individual needs in production capacity, in addition to the large automated capillary electrophoresis menu.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart reagent management:\u003c\/strong\u003e 4 open positions for main reagents, temperature-controlled section for secondary reagent (antisera), automated reagent identification, change buffer without interrupting the testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced piloting Software:\u003c\/strong\u003e Delivered with each Sebia’s instrument, the PHORESIS software allows laboratory to manage the instrument results providing a very flexible solution.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Menu\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eSerum Protein Electrophoresis (SPE)\u003c\/li\u003e \u003cli\u003eSerum Immunotyping\u003c\/li\u003e \u003cli\u003eUrine Protein Electrophoresis (UPE)\u003c\/li\u003e \u003cli\u003eUrine Immunotyping\u003c\/li\u003e \u003cli\u003eHb A1c (venous blood \u0026amp; capillary blood)\u003c\/li\u003e \u003cli\u003eHemoglobin Electrophoresis (adult blood)\u003c\/li\u003e \u003cli\u003eCDT \u0026amp; CDT\u003csub\u003eIFCC\u003c\/sub\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eSample types: whole blood, urine, serum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eWith 8 capillaries, the CAPILLARYS 3 OCTA reduces hands-on-time and offers a large loading capacity with 120 samples (15 racks).\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTest\u003c\/th\u003e\n\u003cth\u003eThroughput (tests\/hour)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROTEIN(E) 6 (serum)\u003c\/td\u003e\n\u003ctd\u003e79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROTEIN(E) 6 (urine)\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIMMUNOTYPING (serum or urine)\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHb A1c\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHEMOGLOBIN(E)\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCDT\u003c\/td\u003e\n\u003ctd\u003e49\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e* Using Software version 9.30\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReagent and consumables\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003e4 flexible positions for reagents \u0026gt; optimize your on-board reagent strategy\u003c\/li\u003e \u003cli\u003eReload reagents without halting specimen analysis \u0026gt; generate results without interruption\u003c\/li\u003e \u003cli\u003eRFID identification for all reagents (reagent type, lot number, expiration date, volume) \u0026gt; comprehensive traceability throughout workflow\u003c\/li\u003e \u003cli\u003eReagent cups automatically loaded\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eErgonomics\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eEmbedded user interface with a touch screen\u003c\/li\u003e \u003cli\u003eAutomatic technique change\u003c\/li\u003e \u003cli\u003eAutomatic start-up and shut-down\u003c\/li\u003e \u003cli\u003eVisual alarms (with instrument notifications)\u003c\/li\u003e \u003cli\u003eDedicated workstation to pilot the instrument and manage results\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e1245\u003c\/td\u003e\n\u003ctd\u003eCAPILLARYS 3 OCTA\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"Default Title","offer_id":67629798555727,"sku":"1245","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/OCTA_web.1.2.webp?v=1791284865"},{"product_id":"capillarys-3-tera-capillary-electrophoresis-analyzer-1246","title":"CAPILLARYS 3 TERA Capillary Electrophoresis Analyzer","description":"\u003cp\u003eCompared to the previous generation, CAPILLARYS 3 TERA offers the enhanced throughput of a 12 capillary system and can be turned into a MC configuration, aggregating 1 to 3 CAPILLARYS 3 TERA to a tube loader (528 positions).\u003c\/p\u003e \u003cp\u003eThe CAPILLARYS 3 TERA offers a broad assay menu in myeloma, diabetes, hemoglobinopathies and chronic alcohol abuse.\u003c\/p\u003e \u003cp\u003eThe CAPILLARYS 3 TERA shares the same reagents and consumables as the other CAPILLARYS 3 instruments, allowing the lab to adopt the most relevant platforms, mixing CAPILLARYS 3 OCTA, TERA, TERA TLA and TERA MC configurations to match exactly the needs of their organization.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable:\u003c\/strong\u003e CAPILLARYS 3 TERA instruments can evolve into a workcell configuration. Linked to Sebia’s MC loader, 1 to 3 CAPILLARYS 3 TERA will deliver a very high throughput for a single or multiple electrophoresis capillary techniques.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart reagent management:\u003c\/strong\u003e 4 open positions for main reagents, temperature-controlled section for secondary reagent (antisera), automated reagent identification, change buffer without interrupting the testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced piloting Software:\u003c\/strong\u003e Delivered with each Sebia’s instrument, the PHORESIS software allows laboratories to manage the instrument results providing a very flexible solution.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Menu\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eSerum Protein Electrophoresis (SPE)\u003c\/li\u003e \u003cli\u003eSerum Immunotyping\u003c\/li\u003e \u003cli\u003eUrine Protein Electrophoresis (UPE)\u003c\/li\u003e \u003cli\u003eUrine Immunotyping\u003c\/li\u003e \u003cli\u003eHb A1c (venous blood \u0026amp; capillary blood)\u003c\/li\u003e \u003cli\u003eHemoglobin Electrophoresis (adult blood)\u003c\/li\u003e \u003cli\u003eCDT \u0026amp; CDT\u003csub\u003eIFCC\u003c\/sub\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eSample types: whole blood, urine, serum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eWith 12 capillaries, the CAPILLARYS 3 TERA can produce large amount of results with a low hands-on-time. The instrument has a related loading capacity of 15 racks (120 tubes).\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTest\u003c\/th\u003e\n\u003cth\u003eThroughput (tests\/hour)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROTEIN(E) 6 (serum)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROTEIN(E) 6 (urine)\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIMMUNOTYPING (serum or urine)\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHb A1c\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHEMOGLOBIN(E)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCDT\u003c\/td\u003e\n\u003ctd\u003e73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e* Using Software version 9.30\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReagent and consumables\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003e4 flexible positions for reagents \u0026gt; optimize your on-board reagent strategy\u003c\/li\u003e \u003cli\u003eReload reagents without halting specimen analysis \u0026gt; generate results without interruption\u003c\/li\u003e \u003cli\u003eRFID identification for all reagents (reagent type, lot number, expiration date, volume) \u0026gt; comprehensive traceability throughout workflow\u003c\/li\u003e \u003cli\u003eDilution cups automatically loaded \u0026gt; Accessible loading position\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eErgonomics\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eEmbedded user interface with a touch screen\u003c\/li\u003e \u003cli\u003eAutomatic technique change\u003c\/li\u003e \u003cli\u003eAutomatic start-up and shut-down\u003c\/li\u003e \u003cli\u003eVisual alarms (with instrument notifications)\u003c\/li\u003e \u003cli\u003eDedicated workstation to pilot the instrument and manage results\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eTERA MC Workcell Configuration\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eCapillary Electrophoresis solution to meet your high capacity needs.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe CAPILLARYS 3 TERA MC is a powerful and versatile instrument that consolidates the performance and functionality of three CAPILLARYS 3 TERA instruments into one Workcell.\u003c\/p\u003e \u003cp\u003eThe ergonomics of the Tube Loader allows for efficient sample loading, with a capacity of up to 528 samples. This high sample loading capacity enables the instrument to operate autonomously for up to 3 hours, conducting up to 600 tests without the need for constant supervision.\u003c\/p\u003e \u003cp\u003eAdditionally, the user-friendly features such as the LCD Touchscreen interface and Beacon enhance the overall user experience, making operation smooth and intuitive.\u003c\/p\u003e\u003cp\u003eThe CAPILLARYS 3 TERA MC workcell adds the CAPILLARYS 3 TUBE LOADER (P\/N 1249), RACK CONVEYOR (P\/N 1250) and BEACON (P\/N 1397) modules to one or more CAPILLARYS 3 TERA units - ask us for a workcell quotation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTest Menu\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eSerum Protein Electrophoresis (SPE)\u003c\/li\u003e \u003cli\u003eSerum Immunotyping\u003c\/li\u003e \u003cli\u003eUrine Protein Electrophoresis (UPE)\u003c\/li\u003e \u003cli\u003eUrine Immunotyping\u003c\/li\u003e \u003cli\u003eHb A1c (venous blood \u0026amp; capillary blood)\u003c\/li\u003e \u003cli\u003eHemoglobin Electrophoresis (adult blood)\u003c\/li\u003e \u003cli\u003eCDT \u0026amp; CDT\u003csub\u003eIFCC\u003c\/sub\u003e\n\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eSample types: whole blood, urine, serum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eWith up to 36 capillaries, the high volume workcell CAPILLARYS 3 TERA MC can respond to the highest volume with a low hands-on-time. The loader can receive 66 racks in one go (528 samples).\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTest\u003c\/th\u003e\n\u003cth\u003eThroughput (tests\/hour)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROTEIN(E) 6 (serum or urine)\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIMMUNOTYPING (serum or urine)\u003c\/td\u003e\n\u003ctd\u003e34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHb A1c\u003c\/td\u003e\n\u003ctd\u003e185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHEMOGLOBIN(E)\u003c\/td\u003e\n\u003ctd\u003e189\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCDT\u003c\/td\u003e\n\u003ctd\u003e211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e* refer to your local representative for the last update.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReagent and consumables\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003e4 customizable reagent positions \u0026gt; tailor your on-board reagent strategy to your specific needs\u003c\/li\u003e \u003cli\u003eHigh reagent capacity to up to 4’600 tests \u0026gt; maximize you walk-away time\u003c\/li\u003e \u003cli\u003eAutomated and seamless reagent switch \u0026gt; optimize your resources\u003c\/li\u003e \u003cli\u003eRFID tag to track reagent lot, opening date, consumption \u0026gt; comprehensive and simple automated traceability\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eErgonomics\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eReduced footprint to reduce transportation and motion\u003c\/li\u003e \u003cli\u003eMulticlient 43″ screen to monitor your results from a single workstation\u003c\/li\u003e \u003cli\u003eLCD Touch screen user interface enables easy control of the Workcell\u003c\/li\u003e \u003cli\u003eBeacon feature helps minimize and prevent downtime through visual management\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e1246\u003c\/td\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"Default Title","offer_id":67629798817871,"sku":"1246","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/CAPILLARYS-3-TERA-electrophoresis-system.webp?v=1791284869"},{"product_id":"urine-protein-capillary-electrophoresis-kit-2513","title":"URINE Protein Capillary Electrophoresis Kit","description":"\u003cp\u003e\u003cstrong\u003eHigh throughput Urine Protein Electrophoresis, with high resolution results.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUrine Protein Electrophoresis is a well-established technique routinely used in clinical laboratories to detect and estimate the concentration of monoclonal components as Bence Jones proteins (Monoclonal Free Light Chains) or other proteinuria disorders.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully automated testing:\u003c\/strong\u003e for qualitative analysis with fast separation and good resolution with dedicated reagent and program on CAPILLARYS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect visualisation of urine protein profile:\u003c\/strong\u003e for quick screening and identification of abnormal urinary pattern.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparation into major protein fraction:\u003c\/strong\u003e CAPI 3 PROTEIN(E) 6 kit enables the separation into five major zones: Albumin, Alpha-1, Alpha-2, Beta, Gamma.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbility to quantify abnormal peaks in two modes:\u003c\/strong\u003e Valley to valley or Baseline to top.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUrine Proteins are separated in silica capillaries by their electrophoretic mobility and the electroosmotic flow at high voltage in an alkaline buffer. Proteins are directly detected during migration by UV absorbance and quantified by a peak.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUrine\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eFull traceability and positive sample ID for primary tube samples\u003c\/li\u003e \u003cli\u003eFull traceability and reagents management through RFID tags\u003c\/li\u003e \u003cli\u003eColor-coded backlit reagent containers\u003c\/li\u003e \u003cli\u003eRapid validation via 48 to 96 profile mosaic display\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cp\u003eLimit of detection with CAPI 3 URINE:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eProtein abnormality is approximately 9 mg\/L\u003c\/li\u003e \u003cli\u003eBence Jones protein is approximately 20 mg\/L\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cem\u003e\u003cstrong\u003eLarge autonomy\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eSamples up to 528 tubes (with tube loader)\u003c\/li\u003e \u003cli\u003e\u0026gt;2.5 hours protein testing\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eThroughput\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eInstrument\u003c\/th\u003e\n\u003cth\u003eThroughput (tests\/hour)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROTEIN(E)\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 OCTA\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA MC3\u003c\/td\u003e\n\u003ctd\u003e238\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 OCTA\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA MC3\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eInstrument\u003c\/th\u003e\n\u003cth\u003eThroughput (tests\/hour)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROTEIN(E)\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 OCTA\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA MC3\u003c\/td\u003e\n\u003ctd\u003e238\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 OCTA\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA MC3\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIMMUNOTYPING\u003cbr\u003e \u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e* Using Software version 9.30\u003c\/p\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eInstrument\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2513\u003c\/td\u003e\n\u003ctd\u003eCAPI 3 URINE\u003c\/td\u003e\n\u003ctd\u003eCAPILLARYS 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2013\u003c\/td\u003e\n\u003ctd\u003eCAPILLARYS\/MINICAP URINE(48\/96T)\u003c\/td\u003e\n\u003ctd\u003eCAPILLARYS \/ MINICAP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"CAPILLARYS 3","offer_id":67629798883407,"sku":"2513","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"CAPILLARYS \/ MINICAP","offer_id":67629798916175,"sku":"2013","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/OCTA_web.1.2.webp?v=1791284865"},{"product_id":"protein-e-6-serum-protein-capillary-electrophoresis-kit-2503","title":"PROTEIN(E) 6 Serum Protein Capillary Electrophoresis Kit","description":"\u003cp\u003e\u003cstrong\u003eHigh throughput Serum Protein Electrophoresis, with high resolution results.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum Protein Electrophoresis is a well-established technique routinely used in clinical laboratories to screen samples to detect protein abnormalities as monoclonal gammopathies (Multiple Myeloma, MGUS, Waldenström disease) or inflammatory pattern…\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully automated testing:\u003c\/strong\u003e for qualitative or quantitative analysis with fast serum protein separation and good resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect visualisation of Serum Protein profile:\u003c\/strong\u003e for quick screening and identification of abnormal patterns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparation into major protein fractions:\u003c\/strong\u003e CAPI 3 PROTEIN(E) 6 kit enables the separation into six major fractions: Albumin, Alpha-1, Alpha-2, Beta-1, Beta-2, Gamma.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbility to quantify abnormal peaks in two modes:\u003c\/strong\u003e Valley to valley or Baseline to top.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum Proteins are separated in silica capillaries by their electrophoretic mobility and the electroosmotic flow at high voltage in an alkaline buffer. Proteins are directly detected during migration by UV absorbance at 200 nm and quantified by the peak quantification tool.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eFull traceability and positive sample ID from primary tube samples\u003c\/li\u003e \u003cli\u003eFull traceability and reagents management through RFID tags\u003c\/li\u003e \u003cli\u003eColor-coded backlit reagent containers\u003c\/li\u003e \u003cli\u003eRapid validation via 96 profile mosaic display\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eMonoclonal protein can be detected at a concentration as low as 19 mg\/dL.\u003c\/li\u003e \u003cli\u003eAccording to the mobility of the monoclonal component and polyclonal background, the sensitivity may vary.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cem\u003e\u003cstrong\u003eLarge autonomy\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eSamples up to 528 tubes (with tube loader)\u003c\/li\u003e \u003cli\u003e\u0026gt; 2.5 hours protein testing\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eThroughput\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eInstrument\u003c\/th\u003e\n\u003cth\u003eThroughput (tests\/hour)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROTEIN(E)\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 OCTA\u003c\/td\u003e\n\u003ctd\u003e79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA MC3\u003c\/td\u003e\n\u003ctd\u003e243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA TLA\u003c\/td\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMINICAP FLEX-PIERCING\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 OCTA\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA MC3\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eInstrument\u003c\/th\u003e\n\u003cth\u003eThroughput (tests\/hour)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROTEIN(E)\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 OCTA\u003c\/td\u003e\n\u003ctd\u003e79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA MC3\u003c\/td\u003e\n\u003ctd\u003e243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA TLA\u003c\/td\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMINICAP FLEX-PIERCING\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 OCTA\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA MC3\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eIMMUNOTYPING\u003cbr\u003e \u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCAPILLARYS 3 TERA TLA 13 \u003cem\u003e(front loading only)\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003eMINICAP FLEX-PIERCING 1.7\u003c\/p\u003e\u003cp\u003e* Using Software version 9.30\u003c\/p\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eInstrument\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2503\u003c\/td\u003e\n\u003ctd\u003eCAPI 3 PROTEIN(E) 6\u003c\/td\u003e\n\u003ctd\u003eCAPILLARYS 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2203\u003c\/td\u003e\n\u003ctd\u003eMINICAP PROTEIN(E) 6\u003c\/td\u003e\n\u003ctd\u003eMINICAP FLEX-PIERCING\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"CAPILLARYS 3","offer_id":67629799112783,"sku":"2503","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"MINICAP FLEX-PIERCING","offer_id":67629799145551,"sku":"2203","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/OCTA_web.1.2.webp?v=1791284865"},{"product_id":"hemoglobin-e-hemoglobin-capillary-electrophoresis-kit-2507","title":"HEMOGLOBIN(E) Hemoglobin Capillary Electrophoresis Kit","description":"\u003cp\u003e\u003cstrong\u003eThe high-resolution method for hemoglobin disorders screening.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eHemoglobin electrophoresis is a well-established technique routinely used in clinical laboratories to screen patient samples for hemoglobinopathies (hemoglobin variants and thalassemias).\u003c\/p\u003e \u003cp\u003eMany international societies such as TIF, CDC and APHL recognise the benefits of the Sebia Capillary Electrophoresis (CE) technology, such as the high resolution and its clear hemoglobin fractions profile in the screening of hemoglobin disorders.\u003c\/p\u003e \u003cp\u003eIn addition to the Capillary electrophoresis, Sebia provides Gel technique-based solutions: HYDRAGEL HEMOGLOBIN(E) and HYDRAGEL ACID(E) HEMOGLOBIN(E) that enable, on the HYDRASYS instruments the separation of the hemoglobins and the detection of the major hemoglobin variants: S or D and C or E, by electrophoresis on alkaline agarose gels.\u003c\/p\u003e \u003cp\u003eElectrophoresis on acidic gels, like HYDRAGEL ACID(E) HEMOGLOBIN(E), should follow to confirm the identification of hemoglobin variants, mainly, to differentiate hemoglobins S from D and E from C.\u003c\/p\u003e \u003cp\u003eThe visualization of the gel provides qualitative and quantitative (HbA and HbA2) analysis.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully automated:\u003c\/strong\u003e CAPILLARYS instruments perform all sequences automatically, from primary tube sampling to final clear-cut profile, with precise quantification and presumptive identification of the most common hemoglobins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh resolution:\u003c\/strong\u003e CAPILLARYS instruments allow high resolution separation of the major hemoglobin variants (Hb S, Hb C, Hb D and Hb E) and accurate quantification of the Hb A2 and Hb F. Furthermore, the Sebia CE technique is highly reproducible and the migration position given by the software can be used as an aid in the identification of Hb variants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnhanced detection:\u003c\/strong\u003e Capillary zone electrophoresis allows clean separation of Hb E from Hb A2 and facilitates easier detection of Hb Bart’s and Hb H, the X-axis migration position is a great help in the presumptive identification of hemoglobin variants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdapted to each laboratory:\u003c\/strong\u003e Thanks to the broad range of capillary instruments, the hemoglobin technique answers the needs and variable workload of all laboratories involved in abnormal hemoglobin screening.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eThe HEMOGLOBIN(E) assay is based on the principle of capillary electrophoresis in free solution. Hemoglobin fractions are separated in silica capillaries, by their electrophoretic mobility and electroosmotic flow at a high voltage in an alkaline buffer.\u003c\/li\u003e \u003c\/ul\u003e \u003cul\u003e \u003cli\u003eHemoglobin fractions are directly detected at the specific absorbance of 415 nm. The pattern is divided into 15 zones (12 zones for cord blood). Each zone displays a drop-down library of possible variants migrating within this zone. More than 500 variants are listed.\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eWhole blood sample are used and are analysed directly on Capillary instruments.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHEMOGLOBIN(E)\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eInstrument\u003c\/th\u003e\n\u003cth\u003eThroughput (tests\/hour)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 OCTA\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA MC3\u003c\/td\u003e\n\u003ctd\u003e176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMINICAP FLEX-PIERCING\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e* Using Software version 9.30\u003c\/p\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eInstrument\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2507\u003c\/td\u003e\n\u003ctd\u003eCAPI 3 Hb\u003c\/td\u003e\n\u003ctd\u003eCAPILLARYS 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2207\u003c\/td\u003e\n\u003ctd\u003eMINICAP HEMOGLOBIN(E)\u003c\/td\u003e\n\u003ctd\u003eMINICAP FLEX-PIERCING\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"CAPILLARYS 3","offer_id":67629799243855,"sku":"2507","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"MINICAP FLEX-PIERCING","offer_id":67629799276623,"sku":"2207","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/OCTA_web.1.2.webp?v=1791284865"},{"product_id":"cdt-carbohydrate-deficient-transferrin-capillary-electrophoresis-kit-2509","title":"CDT Carbohydrate-Deficient Transferrin Capillary Electrophoresis Kit","description":"\u003cp\u003e\u003cstrong\u003eThe most reliable chronic alcohol abuse marker.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eExcessive chronic alcohol consumption is a public health problem. Its diagnosis and monitoring will improve clinical outcome, reduce accidents and costs related to alcohol. Carbohydrate Deficient Transferrin (CDT) is the IFCC recommended biomarker for chronic alcohol abuse. CAPI 3 CDT and MINICAP CDT are designed to quantify CDT by capillary electrophoresis on patient serum samples. During analysis, serum transferrin isoforms are separated into five major fractions according to their sialylation level:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eAsialotransferrin (non-sialylated)\u003c\/li\u003e \u003cli\u003eDisialotransferrin\u003c\/li\u003e \u003cli\u003eTrisialotransferrin\u003c\/li\u003e \u003cli\u003eTetrasialotransferrin\u003c\/li\u003e \u003cli\u003ePentasialotranferrin\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eCDT\u003csub\u003eIFCC\u003c\/sub\u003e percent value is automatically displayed based on the calibration curve of disialotransferrin.\u003c\/p\u003e \u003cp\u003eIf CDT\u003csub\u003eIFCC\u003c\/sub\u003e is not implemented, a classic CDT percent value is automatically calculated using the low-sialylated isoforms, i.e., disialotransferrin associated with asialotransferrin (if present).\u003c\/p\u003e \u003cp\u003eThe interpretation is simple. CDT\u003csub\u003eIFCC\u003c\/sub\u003e greater than 2% are abnormal and indicative of chronic alcohol abuse whereas with classic CDT, results over 1.6%. are abnormal and indicative of chronic alcohol abuse.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimple, secured and accurate CDT measurement:\u003c\/strong\u003e Normal clinical result: CDT IFCC ≤ 1.7% Forensic positive result: CDT IFCC \u0026gt; 2%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduced hands-on time:\u003c\/strong\u003e Ready to use reagents, no sample pre-treatment and no need for additional total transferrin measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic measurement with visualization of all transferrin isoforms:\u003c\/strong\u003e Potential analytical and genetical interferences (variants, CDG) and curve abnormalities (such as in cirrhotic pattern) can thus be detected and prevent false result reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable solution to fit all lab’s configuration:\u003c\/strong\u003e CDT is available on MINICAP and CAPILLARYS family offering multiple configurations for streamlined workflow.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eCAPI 3 CDT – MINICAP CDT assays are based on the principle of capillary electrophoresis in free solution. Transferrin isoforms are separated in silica capillaries by their electrophoretic mobility and the electroosmotic flow at high voltage in an alkaline buffer. Transferrin isoforms are directly detected during migration by UV absorbance.\u003c\/li\u003e \u003c\/ul\u003e \u003cul\u003e \u003cli\u003eAll analysis steps are performed automatically. The sample dilution is done using a specific diluent allowing iron saturation.\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum sample is needed to perform CDT test. In the context of forensic use, the serum sample unlike hair and urine, can ensure the integrity, the reliability of the analysis and avoid possible fraud.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCDT\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eInstrument\u003c\/th\u003e\n\u003cth\u003eThroughput (tests\/hour)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 OCTA\u003c\/td\u003e\n\u003ctd\u003e49\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA\u003c\/td\u003e\n\u003ctd\u003e73\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA MC3\u003c\/td\u003e\n\u003ctd\u003e179\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMINICAP FLEX-PIERCING\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e* Using Software version 9.30\u003c\/p\u003e\u003cul\u003e \u003cli\u003eFull traceability and positive ID for samples and reagents\u003c\/li\u003e \u003cli\u003eRapid validation through color-coded profiles using the mosaic screen\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eInstrument\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2509\u003c\/td\u003e\n\u003ctd\u003eCAPI 3 CDT\u003c\/td\u003e\n\u003ctd\u003eCAPILLARYS 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2208\u003c\/td\u003e\n\u003ctd\u003eMINICAP CDT\u003c\/td\u003e\n\u003ctd\u003eMINICAP FLEX-PIERCING\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"CAPILLARYS 3","offer_id":67629799637071,"sku":"2509","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"MINICAP FLEX-PIERCING","offer_id":67629799669839,"sku":"2208","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/OCTA_web.1.2.webp?v=1791284865"},{"product_id":"hb-a1c-glycated-hemoglobin-capillary-electrophoresis-kit-2515","title":"Hb A1c Glycated Hemoglobin Capillary Electrophoresis Kit","description":"\u003cp\u003e\u003cstrong\u003eUncompromized HbA1c Results.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eAs of today more than 463 million of people have diabetes worldwide, and around 50 % of people having diabetes are undiagnosed.\u003c\/p\u003e \u003cp\u003eGlycated hemoglobin (HbA1c) is a key parameter in the diagnosis of diabetes, HbA1c reflects the average blood glucose over the 3 past months.\u003cbr\u003e WHO has concluded, almost one decade ago, that HbA1c can be used as a diagnostic test for diabetes. An HbA1c of 6.5% (48 mmol\/mol) is recommended as the cut point for diagnosing diabetes.\u003c\/p\u003e \u003cp\u003eThe HbA1c test is an indispensable part of routine management of diabetes.\u003c\/p\u003e \u003cp\u003eBased on many years of experiences in Capillary electrophoresis technology, Sebia has adapted this technology for HbA1c testing. This innovative technology provides to laboratories and clinicians accurate and meaningful results to ensure a better patient management.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExcellent separation:\u003c\/strong\u003e The clear-cut and precise separation of the different hemoglobin fractions allows accurate HbA1c measurement thanks to high resolution separation of our capillary instruments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo interferences:\u003c\/strong\u003e There is no alteration of results in the presence of frequent interferences (labile A1c, carbamylated Hb, Hb F, Hb S, Hb C, Hb D and Hb E) as well as the incidental detection of the common hemoglobin disorders (sickle cell, beta-thalassemia…).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeaningful results:\u003c\/strong\u003e Using the IFCC reference method calculation formula HbA1c\/(HbA1c+HbA0), developed for the worldwide assay standardization, the Sebia methodology ensures accurate and reliable results. Unlike other HbA1c testing methods, Sebia CE technology will not provide any spurious results in presence of sample having homozygous hemoglobin variant or presenting hemoglobin variant interfering with HbA1c calculation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdapted to each laboratory:\u003c\/strong\u003e With our broad range of capillary instruments, the laboratory can choose the most suitable platform for its needs, from a benchtop standalone instrument up to the TLA configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eHbA1c is defined as the hemoglobin A which is irreversibly glycated at one or both N-terminal valines of the beta chain.\u003c\/p\u003e \u003cp\u003eThe level of glycated hemoglobin corresponds to the “integration” of all the glycemic variations during the previous weeks.\u003c\/p\u003e \u003cp\u003eIt can be used:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eas an index of diabetes control. This quantification allows to evaluate the middle term efficiency of treatments,\u003c\/li\u003e \u003cli\u003eas an aid in the diagnosis of diabetes mellitus and as an aid in the identification of patients at risk for developing diabetes mellitus\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eWhole blood samples are used and analysed directly on Capillary instruments.\u003c\/li\u003e \u003cli\u003eThe Sebia CAPILLARY BLOOD SAMPLE KIT can be used on Capillary instrument and is an interesting alternative to venous blood sampling for HbA1c measurement.\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHb A1c test\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eInstrument\u003c\/th\u003e\n\u003cth\u003eThroughput (tests\/hour)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 OCTA\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA MC3\u003c\/td\u003e\n\u003ctd\u003e176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA TLA\u003c\/td\u003e\n\u003ctd\u003e58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMINICAP FLEX-PIERCING\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e* Using Software version 9.30\u003c\/p\u003e\u003cul\u003e \u003cli\u003eNo interference from common hemoglobin variants, or HbF or carbamylated hemoglobin.\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eInstrument\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2515\u003c\/td\u003e\n\u003ctd\u003eCAPI 3 HBA1C\u003c\/td\u003e\n\u003ctd\u003eCAPILLARYS 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2215\u003c\/td\u003e\n\u003ctd\u003eMINICAP HbA1c\u003c\/td\u003e\n\u003ctd\u003eMINICAP FLEX-PIERCING\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"CAPILLARYS 3","offer_id":67629799571535,"sku":"2515","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"MINICAP FLEX-PIERCING","offer_id":67629799604303,"sku":"2215","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/OCTA_web.1.2.webp?v=1791284865"},{"product_id":"immunotyping-serum-urine-capillary-immunotyping-kit-2600","title":"IMMUNOTYPING Serum \u0026 Urine Capillary Immunotyping Kit","description":"\u003cp\u003e\u003cstrong\u003eFully automated monoclonal proteins identification by Capillarys electrophoresis.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eImmunotyping is used to detect and identify monoclonal proteins in serum and urine. Serum and urine proteins are mixed with specific antisera against Gamma- (IgG), Alpha- (IgA), Mu- (IgM) heavy chains Kappa (κ) and Lambda (λ) free and bound light chains.\u003c\/p\u003e \u003cp\u003eImmunoglobulins specifically react with their corresponding antiserum and each antiserum pattern (IgG, IgA, IgM, κ and λ) is automatically overlaid with the ELP (Protein Electrophoresis) reference curve. Disappearance of the abnormality in the antiserum-treated pattern indicates the presence of a monoclonal protein.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully automated testing:\u003c\/strong\u003e Qualitative analysis with fast separation and good resolution of serum and urine samples.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect visualisation of serum and urine protein profile:\u003c\/strong\u003e for quick identification of suspect monoclonal proteins (IgG, IgA, IgM, Kappa (κ) and Lambda (λ)) involved in gammopathy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh quality of antisera ready to use:\u003c\/strong\u003e for an optimum reaction performance and correct monoclonal component identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScalable solutions:\u003c\/strong\u003e to best fit the need for all sized laboratories, from a standalone instrument to workcell up to a Total Lab Automation (TLA) configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest principle\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eBased on the principle of capillary electrophoresis in free solution. Serum or Urine proteins are mixed with specific antisera.\u003c\/li\u003e \u003cli\u003eImmunoglobulins specifically react with their corresponding antiserum. At the end of the analysis, each antiserum pattern (IgG, IgA, IgM, κ and λ) is automatically overlaid with the ELP (Protein Electrophoresis) reference curve.\u003c\/li\u003e \u003cli\u003eDisappearance of the abnormality in the antiserum-treated pattern indicates the presence of a monoclonal protein.\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSample type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum \u0026amp; Urine\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eFull traceability and positive sample ID from primary tube samples\u003c\/li\u003e \u003cli\u003eFull traceability and reagents management through RFID tags for both reagents and antisera\u003c\/li\u003e \u003cli\u003eOn board antisera vials kept at cool temperature\u003c\/li\u003e \u003cli\u003eFull automation\u003c\/li\u003e \u003cli\u003eColor-coded backlit reagent containers\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eMonoclonal protein can be detected at a concentration as low as 12.5 mg\/dL in serum. According to the mobility of the monoclonal component and polyclonal background, the sensitivity may vary.\u003c\/li\u003e \u003cli\u003eProtein abnormality limit of detection is approximately 9 mg\/L with CAPI 3 URINE.\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eThroughput\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIMMUNOTYPING\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eInstrument\u003c\/th\u003e\n\u003cth\u003eThroughput (tests\/hour)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 OCTA (serum or urine)\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA (serum or urine)\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 TERA MC3 (serum or urine)\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003eCAPILLARYS 3 TERA TLA (serum) 13 \u003cem\u003e(front loading only)\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003eMINICAP FLEX-PIERCING (serum) 1.7\u003c\/p\u003e\u003cp\u003e* Using Software version 9.30\u003c\/p\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eInstrument\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2600\u003c\/td\u003e\n\u003ctd\u003eCAPI 3 IT\u003c\/td\u003e\n\u003ctd\u003eCAPILLARYS 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2300\u003c\/td\u003e\n\u003ctd\u003eMINICAP IMMUNOTYPING\u003c\/td\u003e\n\u003ctd\u003eMINICAP FLEX-PIERCING\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"CAPILLARYS 3","offer_id":67629799899215,"sku":"2600","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"MINICAP FLEX-PIERCING","offer_id":67629799931983,"sku":"2300","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/OCTA_web.1.2.webp?v=1791284865"},{"product_id":"capi-3-neonat-hb-newborn-hemoglobin-screening-kit-dried-blood-spots-2506","title":"CAPI 3 NEONAT Hb Newborn Hemoglobin Screening Kit (Dried Blood Spots)","description":"\u003cp\u003e\u003cstrong\u003eThe perfect match for screening hemoglobin disorders in newborns.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eEvery day more than one hundred thousand newborns are screened worldwide for metabolic and endocrine disorders. Although screening for hemoglobin has a long history in some countries (USA or UK), in other countries it is a recent addition to their screening panels (Portugal; Germany).\u003c\/p\u003e \u003cp\u003eThe increase of hemoglobin disorders in regions that previously did not see them has raised awareness of the importance of screening for them in newborns.\u003c\/p\u003e \u003cp\u003eEarly screening has proven to be effective in improving the lives of babies by providing appropriate treatment and follow-up.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEase of use:\u003c\/strong\u003e All the steps are managed automatically by the instrument; it is easy to operate and requires few maintenance procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic result interpretation:\u003c\/strong\u003e Samples are automatically identified as normal or abnormal by the software, allowing laboratories to quickly detect and identify pathological results and quickly releasing non-pathological samples.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExcellent resolution:\u003c\/strong\u003e Thanks to Sebia Capillarys’ high resolution hemoglobins separation, the instrument allows the display of a clear profile, enabling easy identification of abnormal hemoglobin variants (S, C, D and E…) as well as abnormalities arising from thalassemia (Hb H, Hb Bart’s).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarly detection:\u003c\/strong\u003e Early detection of hemoglobin disorders allows appropriate treatment and follow up, improving the infant’s life while reassuring parents.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe CAPI 3 NEONAT Hb kit is intended for the detection of normal hemoglobins (F and A) and abnormal hemoglobin (S, C, D, E and Bart’s) in blood from newborns collected on filter paper. This qualitative analysis is performed by capillary electrophoresis with the CAPILLARYS 3 DBS automated instrument.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eDried neonatal blood spots – Samples are punched (at 3.2 mm size), eluted in distilled water and analysed directly on the CAPILLARYS 3 DBS instrument.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCAPI 3 NEONAT Hb\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eInstrument\u003c\/th\u003e\n\u003cth\u003eThroughput (tests\/hour)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eCAPILLARYS 3 DBS\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e* Using PHORESIS Software version 9.40 D\u003c\/p\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e2506\u003c\/td\u003e\n\u003ctd\u003eCAPI 3 NEONAT HB\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cem\u003e* (optional pathological control)\u003c\/em\u003e\u003c\/p\u003e","brand":"Sebia","offers":[{"title":"Default Title","offer_id":67629799964751,"sku":"2506","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/C3_DBS_Website.2.webp?v=1791284865"},{"product_id":"hydragel-protein-e-serum-urine-protein-electrophoresis-gel-kit-4100","title":"HYDRAGEL PROTEIN(E) Serum \u0026 Urine Protein Electrophoresis Gel Kit","description":"\u003cp\u003eSerum Protein Electrophoresis is a well-established technique routinely used in clinical laboratories to screen samples to detect protein abnormalities as monoclonal gammopathies (Multiple Myeloma, MGUS, Waldenström disease) or inflammatory pattern…\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGood gel serum proteins separation in 5 or 6 major proteins fractions:\u003c\/strong\u003e Albumin, Alpha-1, Alpha-2, Beta, Gamma or Albumin, Alpha-1, Alpha-2, Beta-1, Beta-2, Gamma.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear band visualization:\u003c\/strong\u003e for qualitative and relative quantitative analysis for reliable interpretation of serum protein profile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete semi-automated:\u003c\/strong\u003e HYDRASYS 2 SCAN FOCUSING system including sample application, electrophoretic migration, staining, destaining and scanning connected to PHORESIS Software for interpretation, data \u0026amp; result management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh performance proteins Agarose Gel Electrophoresis separation.:\u003c\/strong\u003e by HYDRASYS 2 automation and standardization of samples preparation with ASSIST pipetting station.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eBased on zone electrophoresis separation on agarose gel.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eInternal sensitivity study demonstrated that a monoclonal protein can be detected in a serum at a concentration as low as 17 mg\/dL.\u003c\/li\u003e \u003cli\u003eAccording to the mobility of the monoclonal component and polyclonal background, the sensitivity may vary.\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eTests per gel\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4100\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 7 PROTEIN(E)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4120\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 15 PROTEIN\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4140\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 30 PROTEIN\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4145\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 54 PROTEIN\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"7","offer_id":67629800292431,"sku":"4100","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"15","offer_id":67629800325199,"sku":"4120","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"30","offer_id":67629800357967,"sku":"4140","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"54","offer_id":67629800390735,"sku":"4145","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydragel-beta1-beta2-serum-urine-protein-electrophoresis-gel-kit-beta1-beta2-separation-4101","title":"HYDRAGEL β1-β2 Serum \u0026 Urine Protein Electrophoresis Gel Kit (β1\/β2 Separation)","description":"\u003cp\u003eSerum Protein Electrophoresis is a well-established technique routinely used in clinical laboratories to screen samples to detect protein abnormalities as monoclonal gammopathies (Multiple Myeloma, MGUS, Waldenström disease) or inflammatory pattern…\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGood gel serum proteins separation in 5 or 6 major proteins fractions:\u003c\/strong\u003e Albumin, Alpha-1, Alpha-2, Beta, Gamma or Albumin, Alpha-1, Alpha-2, Beta-1, Beta-2, Gamma.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear band visualization:\u003c\/strong\u003e for qualitative and relative quantitative analysis for reliable interpretation of serum protein profile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete semi-automated:\u003c\/strong\u003e HYDRASYS 2 SCAN FOCUSING system including sample application, electrophoretic migration, staining, destaining and scanning connected to PHORESIS Software for interpretation, data \u0026amp; result management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh performance proteins Agarose Gel Electrophoresis separation.:\u003c\/strong\u003e by HYDRASYS 2 automation and standardization of samples preparation with ASSIST pipetting station.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eBased on zone electrophoresis separation on agarose gel.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eInternal sensitivity study demonstrated that a monoclonal protein can be detected in a serum at a concentration as low as 17 mg\/dL.\u003c\/li\u003e \u003cli\u003eAccording to the mobility of the monoclonal component and polyclonal background, the sensitivity may vary.\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eTests per gel\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4101\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 7 B1-B2\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4121\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 15 B1-B2\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4141\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 30 B1-B2\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4146\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 54 B1-B2\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"7","offer_id":67629800456271,"sku":"4101","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"15","offer_id":67629800489039,"sku":"4121","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"30","offer_id":67629800521807,"sku":"4141","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"54","offer_id":67629800554575,"sku":"4146","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydragel-hr-high-resolution-protein-electrophoresis-gel-kit-4102","title":"HYDRAGEL HR High-Resolution Protein Electrophoresis Gel Kit","description":"\u003cp\u003e\u003cstrong\u003eProteinuria screening for renal disease.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUrine Protein Electrophoresis is a well-established technique routinely used in clinical laboratories to detect and quantify monoclonal components as Bence Jones proteins (Monoclonal Free Light Chains in urine) or other proteinuria disorder.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGood agarose gel urine proteins separation:\u003c\/strong\u003e in 5 zone proteins indicate by software (from Albumin, to Gamma).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear band visualization:\u003c\/strong\u003e for qualitative and relative quantitative analysis for reliable interpretation of proteinuria screening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete semi-automated:\u003c\/strong\u003e HYDRASYS 2 SCAN FOCUSING system including sample application, electrophoretic migration, staining, destaining and scanning connected to PHORESIS Software for interpretation, data \u0026amp; result management.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eBased on zone electrophoresis separation on agarose gel.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUrine\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eMonoclonal protein limit detection is about 0.017 g\/dL.\u003c\/li\u003e \u003cli\u003eAccording to the position of the monoclonal component and polyclonal background in the gamma zone, the detection limit may vary.\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eTests per gel\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4102\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 7 HR ACID VIOLET\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4122\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 15 HR\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"7","offer_id":67629800783951,"sku":"4102","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"15","offer_id":67629800816719,"sku":"4122","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydragel-5-proteinurie-urine-protein-electrophoresis-gel-kit-4115","title":"HYDRAGEL 5 PROTEINURIE Urine Protein Electrophoresis Gel Kit","description":"\u003cp\u003e\u003cstrong\u003eProteinuria screening for renal disease.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUrine Protein Electrophoresis is a well-established technique routinely used in clinical laboratories to detect and quantify monoclonal components as Bence Jones proteins (Monoclonal Free Light Chains in urine) or other proteinuria disorder.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGood agarose gel urine proteins separation:\u003c\/strong\u003e in 5 zone proteins indicate by software (from Albumin, to Gamma).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear band visualization:\u003c\/strong\u003e for qualitative and relative quantitative analysis for reliable interpretation of proteinuria screening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete semi-automated:\u003c\/strong\u003e HYDRASYS 2 SCAN FOCUSING system including sample application, electrophoretic migration, staining, destaining and scanning connected to PHORESIS Software for interpretation, data \u0026amp; result management.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eBased on zone electrophoresis separation on agarose gel.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUrine\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eMonoclonal protein limit detection is about 0.017 g\/dL.\u003c\/li\u003e \u003cli\u003eAccording to the position of the monoclonal component and polyclonal background in the gamma zone, the detection limit may vary.\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e4115\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 5 PROTEINURIA\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"Default Title","offer_id":67629800849487,"sku":"4115","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydragel-if-serum-urine-immunofixation-gel-kit-4801","title":"HYDRAGEL IF Serum \u0026 Urine Immunofixation Gel Kit","description":"\u003cp\u003e\u003cstrong\u003eIdentification of monoclonal proteins by agarose gel electrophoresis.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eImmunofixation is an immunological method for detection and identification of monoclonal proteins in serum and urine. After the separation of serum and urine proteins according to their charge, the gel is incubated with different specific antisera. The gel is then processed in order to remove the antisera excess prior to the final staining step. The gel is interpreted visually to type all immunoglobulins.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGood performance:\u003c\/strong\u003e for proteins separation and identification of monoclonal component in serum and urine in agarose gel method.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear band visualisation:\u003c\/strong\u003e in serum and urine for quick identification of suspect monoclonal proteins IgG, IgA, IgM, Kappa (κ) or Lambda (λ) and free light chains involved in gammopathy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh quality, ready to use antisera:\u003c\/strong\u003e for optimal reaction performance and accurate monoclonal component identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete semi-automated:\u003c\/strong\u003e HYDRASYS 2 SCAN FOCUSING system including sample application, electrophoretic migration, immunofixation, staining, destaining and scanning connected to PHORESIS Software for data \u0026amp; result management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicate HYDRAGEL BENCE JONES kits:\u003c\/strong\u003e for detection of very small monoclonal components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest principle\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eThe HYDRAGEL IF assay is based on the principle of agarose gel electrophoresis followed by immunofixation.\u003c\/li\u003e \u003cli\u003eAfter the separation of serum or urine proteins according to their charge, the gel is incubated with different specific antisera for characterization of monoclonal component involved in the gammopathy.\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum \u0026amp; Urine\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eThe minimal detection limit for monoclonal immunoglobulins is about 120 mg\/L for gels stained with acid violet and about 250 mg\/L for gels stained with amidoblack.\u003c\/li\u003e \u003cli\u003eAccording to the mobility of the monoclonal component and polyclonal background, the sensitivity may vary.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eInternal sensitivity study demonstrated that a Bence Jones protein can be detected in a serum at a concentration:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eas low as 20 mg\/L with anti-free \u0026amp; bound light chains antisera\u003c\/li\u003e \u003cli\u003eas low as 50 mg\/L with anti-free light chains antisera\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eTests per gel\u003c\/th\u003e\n\u003cth\u003eMask\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4801\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 1 IF (MS)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eStandard Mask (SM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4301\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 1IF (VIOLET) (M.D)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eDynamic Mask (DM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4802\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 2 IF (MS)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eStandard Mask (SM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4302\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 2IF (VIOLET) (M.D)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eDynamic Mask (DM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4804\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 4IF ACID VIOLET (MS)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eStandard Mask (SM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4304\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 4IF (VIOLET) (M.D)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eDynamic Mask (DM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4809\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 9 IF (MS)\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003eStandard Mask (SM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4309\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 9IF (VIOLET) (M.D)\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003eDynamic Mask (DM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cem\u003e* SM: Standard Mask ** DM: Dynamic Mask\u003c\/em\u003e\u003c\/p\u003e","brand":"Sebia","offers":[{"title":"1 \/ Standard Mask (SM)","offer_id":67629801078863,"sku":"4801","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"1 \/ Dynamic Mask (DM)","offer_id":67629801111631,"sku":"4301","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"2 \/ Standard Mask (SM)","offer_id":67629801144399,"sku":"4802","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"2 \/ Dynamic Mask (DM)","offer_id":67629801177167,"sku":"4302","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"4 \/ Standard Mask (SM)","offer_id":67629801209935,"sku":"4804","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"4 \/ Dynamic Mask (DM)","offer_id":67629801242703,"sku":"4304","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"9 \/ Standard Mask (SM)","offer_id":67629801275471,"sku":"4809","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"9 \/ Dynamic Mask (DM)","offer_id":67629801308239,"sku":"4309","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydragel-bence-jones-urine-immunofixation-gel-kit-free-light-chains-4821","title":"HYDRAGEL BENCE JONES Urine Immunofixation Gel Kit (Free Light Chains)","description":"\u003cp\u003e\u003cstrong\u003eIdentification of monoclonal proteins by agarose gel electrophoresis.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eImmunofixation is an immunological method for detection and identification of monoclonal proteins in serum and urine. After the separation of serum and urine proteins according to their charge, the gel is incubated with different specific antisera. The gel is then processed in order to remove the antisera excess prior to the final staining step. The gel is interpreted visually to type all immunoglobulins.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGood performance:\u003c\/strong\u003e for proteins separation and identification of monoclonal component in serum and urine in agarose gel method.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear band visualisation:\u003c\/strong\u003e in serum and urine for quick identification of suspect monoclonal proteins IgG, IgA, IgM, Kappa (κ) or Lambda (λ) and free light chains involved in gammopathy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh quality, ready to use antisera:\u003c\/strong\u003e for optimal reaction performance and accurate monoclonal component identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete semi-automated:\u003c\/strong\u003e HYDRASYS 2 SCAN FOCUSING system including sample application, electrophoretic migration, immunofixation, staining, destaining and scanning connected to PHORESIS Software for data \u0026amp; result management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicate HYDRAGEL BENCE JONES kits:\u003c\/strong\u003e for detection of very small monoclonal components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest principle\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eThe HYDRAGEL IF assay is based on the principle of agarose gel electrophoresis followed by immunofixation.\u003c\/li\u003e \u003cli\u003eAfter the separation of serum or urine proteins according to their charge, the gel is incubated with different specific antisera for characterization of monoclonal component involved in the gammopathy.\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum \u0026amp; Urine\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eThe minimal detection limit for monoclonal immunoglobulins is about 120 mg\/L for gels stained with acid violet and about 250 mg\/L for gels stained with amidoblack.\u003c\/li\u003e \u003cli\u003eAccording to the mobility of the monoclonal component and polyclonal background, the sensitivity may vary.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eInternal sensitivity study demonstrated that a Bence Jones protein can be detected in a serum at a concentration:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eas low as 20 mg\/L with anti-free \u0026amp; bound light chains antisera\u003c\/li\u003e \u003cli\u003eas low as 50 mg\/L with anti-free light chains antisera\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eTests per gel\u003c\/th\u003e\n\u003cth\u003eMask\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4821\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 1 BENCE JONES (MS)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eStandard Mask (SM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4321\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 1 BENCE JONES (M.D)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eDynamic Mask (DM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4822\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 2 BENCE JONES (MS)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eStandard Mask (SM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4322\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 2 BENCE JONES (M.D)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eDynamic Mask (DM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4824\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 4 BENCE JONES (MS)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eStandard Mask (SM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4324\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 4 BENCE JONES (M.D)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eDynamic Mask (DM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cem\u003e* SM: Standard Mask ** DM: Dynamic Mask\u003c\/em\u003e\u003c\/p\u003e","brand":"Sebia","offers":[{"title":"1 \/ Standard Mask (SM)","offer_id":67629801341007,"sku":"4821","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"1 \/ Dynamic Mask (DM)","offer_id":67629801373775,"sku":"4321","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"2 \/ Standard Mask (SM)","offer_id":67629801406543,"sku":"4822","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"2 \/ Dynamic Mask (DM)","offer_id":67629801439311,"sku":"4322","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"4 \/ Standard Mask (SM)","offer_id":67629801472079,"sku":"4824","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"4 \/ Dynamic Mask (DM)","offer_id":67629801504847,"sku":"4324","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydragel-csf-isofocusing-oligoclonal-igg-bands-kit-cns-local-igg-synthesis-4353","title":"HYDRAGEL CSF ISOFOCUSING Oligoclonal IgG Bands Kit (CNS Local IgG Synthesis)","description":"\u003cp\u003e\u003cstrong\u003eThe gold standard assay to objectively detect CNS local IgG synthesis in multiple sclerosis.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePresence of intrathecal IgG suggests inflammatory disease of the Central Nervous System, such as caused by multiple sclerosis (MS).\u003c\/p\u003e \u003cp\u003eThe HYDRAGEL CSF ISOFOCUSING kit used on the HYDRASYS 2 SCAN FOCUSING instrument provides qualitative detection and immunological characterization of IgG oligoclonal banding in human CSF (Cerebro Spinal Fluid) and serum. The semi-automated HYDRASYS instrument enables migration, immunofixation and direct detection on agarose gels, in order to obtain IgG profiles for qualitative analysis.\u003c\/p\u003e \u003cp\u003eThe main recommendations of European Consensus Report for Multiple Sclerosis diagnosis are:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eIsoelectrofocusing (IEF) on Agarose gel for immunoglobulins separation\u003c\/li\u003e \u003cli\u003eUse of non-concentrated CSF material\u003c\/li\u003e \u003cli\u003eSimultaneous analysis of the patient’s serum and CSF\u003c\/li\u003e \u003cli\u003eIdentical IgG concentration in paired CSF-serum samples\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eThe presence of CSF oligoclonal bands only, characterizing local IgG synthesis, tightly correlates with the diagnosis of Multiple Sclerosis. Their presence provides useful information when in agreement with the other clinical investigations.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccurate Diagnosis of inflammatory disease of the CNS:\u003c\/strong\u003e Sensitivity increased about a 100-fold compared to standard immunofixation thanks to the detection with enzyme labelled antibodies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Method:\u003c\/strong\u003e Clear oligoclonal band visualization for a reliable interpretation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFaster result:\u003c\/strong\u003e Simple step-by-step procedure without membrane transfer for 3 hours of turnaround time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance with international consensus:\u003c\/strong\u003e HYDRAGEL CSF ISOFOCUSING meets all requirements needed to objectively detect CNS local IgG synthesis in multiple sclerosis.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe HYDRAGEL CSF ISOFOCUSING assay is based on the principle of agarose gel isoelectrofocusing followed by immunofixation. The patient’s serum and CSF samples are analysed in parallel to compare the IgG distribution.\u003c\/p\u003e \u003cul\u003e \u003cli\u003ePrior to performing the test, it is mandatory to quantify the IgG’s in both liquids, in order to adjust the IgG concentration at the same level in CSF and serum.\u003c\/li\u003e \u003cli\u003eAfter the protein separation according to their isoelectric point, the gel is directly incubated with a peroxidase labelled anti-IgG antiserum, with no need for a membrane blotting step.\u003c\/li\u003e \u003cli\u003eThen, the gel is processed to remove unbound proteins before the enzymatic reaction.\u003c\/li\u003e \u003cli\u003eFinally, the gel is visually evaluated.\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum and CSF samples are performed in parallel for each patient to compare IgG distribution as recommended by the European consensus.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003e2 stages-protocol: Isoelectrofocalisation and Immunofixation for an optimized result\u003c\/li\u003e \u003cli\u003eEnhanced software with high voltage monitoring\u003c\/li\u003e \u003cli\u003eFull traceability and positive ID obtained by connecting the HYDRASYS instrument to the ASSIST pipetting station\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eTests per gel\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4353\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 3 CSF ISOFOCUSING\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4355\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 9 CSF ISOFOCUSING\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"3","offer_id":67629801734223,"sku":"4353","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"9","offer_id":67629801766991,"sku":"4355","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydragel-18-a1at-isofocusing-alpha-1-antitrypsin-phenotyping-kit-4357","title":"HYDRAGEL 18 A1AT ISOFOCUSING Alpha-1 Antitrypsin Phenotyping Kit","description":"\u003cp\u003e\u003cstrong\u003eThe gold standard assay for the alpha 1-antitrypsin (A1AT) phenotype testing.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe most common method to detect A1AT deficiency is protein phenotyping using isoelectric focusing.\u003c\/p\u003e \u003cp\u003eThe HYDRAGEL 18 A1AT ISOFOCUSING kit used on the HYDRASYS 2 SCAN FOCUSING instrument provides qualitative detection of the different phenotypes of the A1AT in human serum.\u003c\/p\u003e \u003cp\u003eThe semi-automated HYDRASYS 2 instrument enables migration, immunofixation and direct detection on agarose gels, to obtain A1AT profiles for qualitative analysis.\u003c\/p\u003e \u003cp\u003ePhenotyping results in conjunction with clinical findings and other laboratory assays aid in the diagnosis of Alpha 1-antitrypsin deficiency.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccurate Diagnosis:\u003c\/strong\u003e 100% of concordance with another agarose gel isocelectric focusing and in agreement with the different phenotypes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Method:\u003c\/strong\u003e Clear band visualization for a reliable interpretation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast result:\u003c\/strong\u003e Simple step-by-step procedure without membrane transfer for 2.5 hours of turnaround time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesting is part of algorithms:\u003c\/strong\u003e HYDRAGEL 18 A1AT ISOFOCUSING is included in both screening and diagnostic algorithms to provide clinicians with phenotype of A1AT proteins secreted in blood circulation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe HYDRAGEL 18 A1AT ISOFOCUSING assay is based on the principle of agarose gel isoelectrofocusing followed by immunofixation.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eAfter the protein separation according to their isoelectric point, the gel is directly incubated with a peroxidase labelled anti-A1AT antiserum with no need for a membrane blotting step.\u003c\/li\u003e \u003cli\u003eThen, the gel is processed in order to remove unbound proteins before the enzymatic reaction.\u003c\/li\u003e \u003cli\u003eFinally, the gel is visually evaluated.\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eHuman serum samples can be used with HYDRAGEL 18 A1AT ISOFOCUSING.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003e2 stages-protocol: Isoelectrofocalisation and Immunofixation for an optimized result\u003c\/li\u003e \u003cli\u003eA1AT controls (MM, MZ and MS) are included in each series of analysis to quickly identify M, S and Z phenotypes.\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e4357\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 18 A1AT ISOFOCUSING W\/O AS\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"Default Title","offer_id":67629801799759,"sku":"4357","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydragel-von-willebrand-multimers-gel-electrophoresis-kit-4359","title":"HYDRAGEL von WILLEBRAND MULTIMERS Gel Electrophoresis Kit","description":"\u003cp\u003e\u003cstrong\u003eMultimer assay simplified.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003evon Willebrand disease (vWD) is a genetic bleeding disorder caused by missing or defective von Willebrand factor (vWF).\u003cbr\u003e Since von Willebrand disease (vWD) is a complex disease, its diagnosis requires a large panel of tests for an accurate diagnosis and classification of vWD. Multimer analysis is an integral part of the diagnostic process and an essential information for the clinicians for an optimal patient management.\u003c\/p\u003e \u003cp\u003eHYDRAGEL von WILLEBRAND MULTIMERS kit is designed for the detection of abnormalities in the vWF multimers distribution related to a haemorrhagic diathesis. The test allows to assess the overall size distribution of von Willebrand factor multimers in human plasma using agarose gel electrophoresis and immunofixation, with the semi-automated HYDRASYS 2 instrument.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemi-automated test:\u003c\/strong\u003e providing standardised and reproducible results.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimplified technique:\u003c\/strong\u003e making this test accessible to any laboratory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWithin-day results:\u003c\/strong\u003e compared to in house tests delivering results in 4-5 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTraceability of the result:\u003c\/strong\u003e with densitometry-based interpretations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eHYDRAGEL von WILLEBRAND MULTIMERS allows separating small, intermediate, and large molecular weight multimers.\u003c\/p\u003e \u003cp\u003eThe assay is carried out in two stages:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eSample pre-treatment followed by an electrophoresis done in SDS agarose gel to separate proteins according to their molecular weight,\u003c\/li\u003e \u003cli\u003edirect immunofixation of multimers in the gel using anti-human vWF antibody followed by immunoenzyme staining to visualize the different multimers.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eThe semi-automated HYDRASYS 2 SCAN FOCUSING instrument performs all the steps needed to obtain gels ready for visual and densitometry-based interpretations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePlasma samples\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eExcellent reproducibility\u003c\/li\u003e \u003cli\u003eAll multimer sizes\u003c\/li\u003e \u003cli\u003eDensitometry helps for results interpretation\u003c\/li\u003e \u003cli\u003ePatient’s profile overlayed with a normal control\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eTests per gel\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4359\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 5 VON WILLEBRAND MULT\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4360\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 11 VON WILLEBRAND MULT\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"5","offer_id":67629802094671,"sku":"4359","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"11","offer_id":67629802127439,"sku":"4360","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydrashift-2-4-daratumumab-immunofixation-interference-kit-4639","title":"HYDRASHIFT 2\/4 daratumumab Immunofixation Interference Kit","description":"\u003cp\u003eHYDRASHIFT 2\/4 daratumumab removes the daratumumab interference from serum immunofixation, so the therapeutic monoclonal antibody is no longer mistaken for a residual M-protein in treated myeloma patients. 20 tests per kit, run on HYDRASYS.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnique shift technology:\u003c\/strong\u003e HYDRASHIFT daratumumab and HYDRASHIFT isatuximab avoid daratumumab or isatuximab interference on HYDRAGEL IF tests.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrust in the results:\u003c\/strong\u003e HYDRASHIFT reduce the risk of incorrect IF interpretation to improve therapy monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy to implement:\u003c\/strong\u003e Fully integrated into IF protocol without sample pre-treatment for a standardized process compliant to IMWG guidelines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFollow IMWG guidelines:\u003c\/strong\u003e Process compliant to IMWG guidelines to assess response to treatment in patient with Multiple Myeloma.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eHYDRASHIFT is an immunofixation procedure performed on HYDRAGEL IF 2\/4 gel and based on the creation of a mAb\/ anti mAb immune complex shift mAb drug (daratumumab or isatuximab) in alpha zone.\u003c\/p\u003e \u003cp\u003eThis complex is visible in the IgG and kappa immunofixation tracks. A negative HYDRASHIFT result demonstrates the absence of endogenous M-protein.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cp\u003eThe limit of immune complex visualized is 0.3 g\/L.\u003c\/p\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e4639\u003c\/td\u003e\n\u003ctd\u003eHYDRASHIFT 2\/4 DARATUMUMAB (20)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"Default Title","offer_id":67629802160207,"sku":"4639","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/hydrahisft_visuel_web1.webp?v=1791284904"},{"product_id":"hydrashift-2-4-isatuximab-immunofixation-interference-kit-4642","title":"HYDRASHIFT 2\/4 isatuximab Immunofixation Interference Kit","description":"\u003cp\u003eHYDRASHIFT 2\/4 isatuximab removes the isatuximab interference from serum immunofixation, so the therapeutic monoclonal antibody is no longer mistaken for a residual M-protein in treated myeloma patients. 40 tests per kit, run on HYDRASYS.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnique shift technology:\u003c\/strong\u003e HYDRASHIFT daratumumab and HYDRASHIFT isatuximab avoid daratumumab or isatuximab interference on HYDRAGEL IF tests.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrust in the results:\u003c\/strong\u003e HYDRASHIFT reduce the risk of incorrect IF interpretation to improve therapy monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy to implement:\u003c\/strong\u003e Fully integrated into IF protocol without sample pre-treatment for a standardized process compliant to IMWG guidelines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFollow IMWG guidelines:\u003c\/strong\u003e Process compliant to IMWG guidelines to assess response to treatment in patient with Multiple Myeloma.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eHYDRASHIFT is an immunofixation procedure performed on HYDRAGEL IF 2\/4 gel and based on the creation of a mAb\/ anti mAb immune complex shift mAb drug (daratumumab or isatuximab) in alpha zone.\u003c\/p\u003e \u003cp\u003eThis complex is visible in the IgG and kappa immunofixation tracks. A negative HYDRASHIFT result demonstrates the absence of endogenous M-protein.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cp\u003eThe limit of immune complex visualized is 0.3 g\/L.\u003c\/p\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e4642\u003c\/td\u003e\n\u003ctd\u003eHYDRASHIFT 2\/4 ISATUXIMAB (40)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"Default Title","offer_id":67629802356815,"sku":"4642","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/hydrahisft_visuel_web1.webp?v=1791284904"},{"product_id":"flc-kappa-free-light-chain-elisa-kit-5102","title":"FLC Kappa Free Light Chain ELISA Kit","description":"\u003cp\u003eFLC Kappa is Sebia's ELISA assay for the quantification of kappa free light chains in serum - the next-generation sFLC test used with serum protein electrophoresis and immunofixation in the diagnosis and monitoring of multiple myeloma and AL amyloidosis. 96-well strip microplate.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable and high analytical performance results:\u003c\/strong\u003e with correct estimation of FLC values without antigen excess or overestimation by polymerization vs Nephelometry \/ Turbidimetry Methods.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrust in the results:\u003c\/strong\u003e with concordance value between SPE and FLC Kappa \u0026amp; FLC Lambda which help on interpretation results.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy to implement:\u003c\/strong\u003e for patient therapy monitoring and meeting IMWG guidelines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 times lower retest rates:\u003c\/strong\u003e vs other methods and lower manual dilutions needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasily adapted and scalable:\u003c\/strong\u003e to any type of ELISA Instrument for standardization and efficiency process.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eQuantification of Kappa or Lambda Free Light Chains is performed with an Enzyme-Linked Immunosorbent Assay (ELISA) procedure utilizing specific antibodies anti-Kappa or anti-Lambda free light chains.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum sample\u003c\/p\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e5102\u003c\/td\u003e\n\u003ctd\u003eFLC KAPPA\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"Default Title","offer_id":67629802455119,"sku":"5102","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/flc_visuel_web.webp?v=1791284909"},{"product_id":"flc-lambda-free-light-chain-elisa-kit-5103","title":"FLC Lambda Free Light Chain ELISA Kit","description":"\u003cp\u003eFLC Lambda is Sebia's ELISA assay for the quantification of lambda free light chains in serum - the next-generation sFLC test used with serum protein electrophoresis and immunofixation in the diagnosis and monitoring of multiple myeloma and AL amyloidosis. 96-well strip microplate.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReliable and high analytical performance results:\u003c\/strong\u003e with correct estimation of FLC values without antigen excess or overestimation by polymerization vs Nephelometry \/ Turbidimetry Methods.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrust in the results:\u003c\/strong\u003e with concordance value between SPE and FLC Kappa \u0026amp; FLC Lambda which help on interpretation results.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy to implement:\u003c\/strong\u003e for patient therapy monitoring and meeting IMWG guidelines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 times lower retest rates:\u003c\/strong\u003e vs other methods and lower manual dilutions needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasily adapted and scalable:\u003c\/strong\u003e to any type of ELISA Instrument for standardization and efficiency process.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eQuantification of Kappa or Lambda Free Light Chains is performed with an Enzyme-Linked Immunosorbent Assay (ELISA) procedure utilizing specific antibodies anti-Kappa or anti-Lambda free light chains.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum sample\u003c\/p\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e5103\u003c\/td\u003e\n\u003ctd\u003eFLC LAMBDA\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"Default Title","offer_id":67629802684495,"sku":"5103","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/flc_visuel_web.webp?v=1791284909"}],"url":"https:\/\/www.danyel.co.il\/collections\/sebia.oembed","provider":"danyel biotech","version":"1.0","type":"link"}