{"title":"NGS Accessories \u0026 Consumables","description":null,"products":[{"product_id":"library-quantification-kit-638324","title":"Library Quantification Kit","description":"\u003cp\u003eThe Library Quantification Kit is used for rapid library quantification prior to Illumina next-generation sequencing. The kit contains all of the\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHighly sensitive quantification of Illumina sequencing libraries—the qPCR-based assay can measure libraries at low concentrations\u003c\/li\u003e\n\u003cli\u003eAllows specific quantification of only adapter-bound DNA molecules\u003c\/li\u003e\n\u003cli\u003eReduces variability in cluster density to improve sequencing results—use prior to sequencing to ensure optimal loading concentration\u003c\/li\u003e\n\u003cli\u003eComplete kit—includes qPCR primers and reagents, and DNA standards for absolute quantification using a standard curve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eIllumina NGS library quantification by qPCR\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.takarabio.com\/documents\/SDS\/ST0289\/ST0289-EGHS-EN.pdf\"\u003eSafety Data Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.takarabio.com\/documents\/User%20Manual\/Library%20Quantification%20Kit%20User%20Manual\/Library%20Quantification%20Kit%20User%20Manual_050919.pdf\"\u003eUser Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.takarabio.com\/documents\/Components%20List\/638324-050719.pdf\"\u003eLibrary Quantification Kit Components List\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Takara Bio","offers":[{"title":"500 Rxns","offer_id":45986088747087,"sku":"638324","price":3812.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/638324-Library-Quantification-Kit-product-600.jpg?v=1782803729"},{"product_id":"dna-standards-for-library-quantification-638325","title":"DNA Standards for Library Quantification","description":"\u003cp\u003eThe DNA Standards for Library Quantification includes four DNA standards (0.01–10 pM) that are used for qPCR-based library quantification prior to Illumina next-generation sequencing. These DNA standards contain specific concentrations of a DNA fragment (538 bp) and are designed specifically for use with the Library Quantification Kit (Cat No. 638324). When used as templates for qPCR with the Library Quantification Kit, the standards will generate 447-bp DNA fragments that can be used to produce a standard curve for determining the concentration of DNA in an Illumina library. The standards are not suitable for use with other qPCR techniques, as they may lead to quantification errors or poor results.\u003c\/p\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHighly sensitive quantification of Illumina sequencing libraries—the qPCR-based assay can measure libraries at low concentrations\u003c\/li\u003e\n\u003cli\u003eAllows specific quantification of only adapter-bound DNA molecules\u003c\/li\u003e\n\u003cli\u003eReduces variability in cluster density to improve sequencing results—use prior to sequencing to ensure optimal loading concentration\u003c\/li\u003e\n\u003cli\u003eComplete kit—includes qPCR primers and reagents, and DNA standards for absolute quantification using a standard curve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003eIllumina NGS library quantification by qPCR\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.takarabio.com\/documents\/Certificate%20of%20Analysis\/638325\/638325.pdf\"\u003eCertificate of Analysis (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.takarabio.com\/documents\/SDS\/ST0289\/ST0289-EGHS-EN.pdf\"\u003eSafety Data Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.takarabio.com\/documents\/User%20Manual\/Library%20Quantification%20Kit%20User%20Manual\/Library%20Quantification%20Kit%20User%20Manual_050919.pdf\"\u003eUser Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.takarabio.com\/documents\/Components%20List\/638324-050719.pdf\"\u003eLibrary Quantification Kit Components List\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Takara Bio","offers":[{"title":"50 Rxns","offer_id":45986088845391,"sku":"638325","price":1687.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/638325-DNA-Standards-for-Library-Quantification-product-600.jpg?v=1782803731"},{"product_id":"seqamp-cb-pcr-buffer-638526","title":"SeqAmp™ CB PCR Buffer","description":"\u003cp\u003eSeqAmp™ CB PCR Buffer is designed for improved compatibility with DNA purification using Agencourt AMPure beads after amplification with SeqAmp DNA Polymerase and works with SMARTer® next-generation sequencing kits.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.takarabio.com\/documents\/Certificate%20of%20Analysis\/638526\/638526.pdf\"\u003eCertificate of Analysis (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.takarabio.com\/documents\/SDS\/ST0664\/ST0664-EGHS-EN.pdf\"\u003eSafety Data Sheet (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.takarabio.com\/documents\/User%20Manual\/SeqAmp%20DNA%20Polymerase%20Protocol\/SeqAmp%20DNA%20Polymerase%20Protocol-At-A-Glance_073014.pdf\"\u003eUser Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Takara Bio","offers":[{"title":"50 Rxns","offer_id":45986089271375,"sku":"638526","price":217.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/638526-SeqAmp-CB-PCR-Buffer-product-600.jpg?v=1782803747"},{"product_id":"nextseq-1000-2000-recycling-tool-20050631","title":"NextSeq 1000\/2000 Recycling Tool","description":"\u003cp\u003eTool used to break down NextSeq 1000\/2000 cartridge into individual components for easy recycling\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\n\n\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eNextSeq 1000\/2000 reagents leverage XLEAP-SBS chemistry to enable a wide range of applications. These reagents offer:\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSequencing output of 10–540 Gb per run, providing adjustable output based on project needs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple flow cell configurations that offer flexibility to support new and emerging applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\n\n\n\u003cdiv\u003e\n\u003cdiv\u003e\n\n\n\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eSustainability and simplicity in one\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eEasy-to-use reagent cartridges deliver a streamlined workflow that reduces the chance for errors, lowers operating costs, improves recyclability, and minimizes waste. The fully-integrated cartridges include reagents, fluidics, and the waste holder, streamlining library loading and instrument use. \u003cbr\u003e\n\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eSimply prepare the reagent cartridge, insert the flow cell, load the library into the cartridge, and insert into the instrument. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\u003cdiv\u003e\n\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eInstruments\u003c\/th\u003e\n\u003ctd\u003e\n\u003ca href=\"https:\/\/www.illumina.com\/systems\/sequencing-platforms\/nextseq-1000-2000.html\"\u003eNextSeq 2000 System\u003c\/a\u003e, \n                    \n                    \u003ca href=\"https:\/\/www.illumina.com\/systems\/sequencing-platforms\/nextseq-1000-2000.html\"\u003eNextSeq 1000 System\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNucleic acid type\u003c\/th\u003e\n\u003ctd\u003eDNA, \n                    \n                    RNA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReagent type\u003c\/th\u003e\n\u003ctd\u003ePaired-end sequencing, \n                    Cluster generation, \n                    Sequencing by synthesis, \n                    \n                    Single-read sequencing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTechnology\u003c\/th\u003e\n\u003ctd\u003e\n                    Sequencing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv\u003e\n\u003cdiv\u003e\n\n\n\n\u003cdiv\u003e\n\u003cdiv\u003e\n\n\u003cp\u003eRequired products\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eUse XLEAP-SBS P1 reagents on both the NextSeq 1000 and NextSeq 2000 Systems. Maximum output: 60 Gb. Maximum single-end reads per run: 100M.\u003c\/p\u003e\n\u003cp\u003eUse XLEAP-SBS P2 reagents on both the NextSeq 1000 and NextSeq 2000 Systems. Maximum output: 240 Gb. Maximum single-end reads per run: 400M. \u003c\/p\u003e\n\u003cp\u003eUse XLEAP-SBS P3 reagents on the NextSeq 2000 System only. Maximum output: 360 Gb. Maximum single-end reads per run: 1.2B.\u003c\/p\u003e\n\u003cp\u003eUse XLEAP-SBS P4 reagents on the NextSeq 2000 System only. Maximum output: 540 Gb. Maximum single-end reads per run: 1.8B.\u003c\/p\u003e\n\u003cp\u003eThe NextSeq 1000\/2000 Index Primer Kit, Read Primer Kit, and Read and Index Primers are optional but required when both custom sequencing primers and Illumina primers are used in a run.* \u003c\/p\u003e\n\u003cp\u003ePhiX Control v3 is recommended for all runs, but is optional for well-balanced library types. \u003c\/p\u003e\n\u003cp\u003e*For Illumina DNA PCR-Free Prep, the XLEAP-SBS cartridge already contains the primers, whereas the standard SBS cartridge does not.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\n \/\n                  Results\n                \n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/nextseq-1000-2000-systems-faq-m-gl-00730\/nextseq-1000-2000-systems-faq-m-gl-00730.pdf\"\u003eNextSeq 1000 and NextSeq 2000 Systems FAQ\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/nextseq-1000-2000-std-sbs-reagent-specs-m-gl-02751\/nextseq-1000-2000-std-sbs-reagent-specs-m-gl-02751.pdf\"\u003eNextSeq 1000 and NextSeq 2000 Systems standard SBS reagent kit specifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/nextseq-1000-2000-xleap-sbs-infographic-m-gl-02284\/nextseq-1000-2000-xleap-sbs-infographic-m-gl-02284.pdf\"\u003eXLEAP-SBS chemistry on the NextSeq 1000 and NextSeq 2000 Systems infographic\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/mid-throughput-campaign-single-cell-flyer-m-gl-03811\/single-cell-flyer-m-gl-03811.pdf\"\u003eIllumina single-cell RNA sequencing flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/oncology-workflows-flyer-m-gl-03764\/oncology-workflows-flyer-m-gl-03764.pdf\"\u003eIllumina oncology workflows flyer\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/nextseq-600c-16s-rrna-application-note-m-gl-01146\/nextseq-600c-16s-rrna-application-note-m-gl-01146.pdf\"\u003e16S rRNA sequencing on NextSeq™ 1000 and NextSeq 2000 Systems\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/nextseq-1000-2000-metagenomics-app-note-m-gl-01147\/nextseq-1000-2000-metagenomics-app-note-m-gl-01147.pdf\"\u003eA shotgun metagenomics NGS workflow for assessing microbial populations in complex samples\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/nextseq-1000-2000-metagenomics-app-note-m-gl-01147\/nextseq-1000-2000-metagenomics-app-note-m-gl-01147-ptb.pdf\"\u003eBrazilian Portuguese\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSupport Documentation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/sequencing\/sequencing_instruments\/nextseq-1000-2000\/documentation.html\"\u003eNextSeq 1000\/2000 Sequencing System Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/sequencing\/sequencing_instruments\/nextseq-1000-2000.html\"\u003eAll NextSeq 1000\/2000 Sequencing System Support Resources Support\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Illumina","offers":[{"title":"Default Title","offer_id":46481903943759,"sku":"20050631","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/nextseq1k2k-flow-cells-p2-p4-web-graphic.png?v=1787578583"},{"product_id":"novaseq-xp-flow-cell-dock-20021663","title":"NovaSeq Xp Flow Cell Dock","description":"\u003cp\u003eIncludes one reusable flow cell holder for use with all NovaSeq flow cells, required for the optional NovaSeq Xp workflow.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe NovaSeq 6000 Xp Workflow supports a variety of applications, such as whole-genome sequencing (WGS), ultradeep exome sequencing, and single-cell sequencing. Improving upon the standard workflow, the NovaSeq 6000 Xp Workflow adds a level of flexibility and control to experimental planning and flow cell configuration on the NovaSeq 6000 System.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSupport Documentation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/sequencing\/sequencing_instruments\/novaseq-6000\/documentation.html\"\u003eNovaSeq 6000 Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/support.illumina.com\/sequencing\/sequencing_instruments\/novaseq-6000.html\"\u003eAll NovaSeq 6000 Support\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Illumina","offers":[{"title":"Default Title","offer_id":46481922752591,"sku":"20021663","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/3-seq-ruo-both_d22473e7-dbef-49fb-87c8-3512078d6688.png?v=1787578633"},{"product_id":"novaseq-library-tubes-accessory-pack-24-tubes-20014015","title":"NovaSeq Library Tubes Accessory Pack (24 tubes)","description":"\u003cp\u003eIncludes 24 NovaSeq 6000 Library Tubes.\u003c\/p\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\n\n\n\u003cdiv\u003e\n\u003cdiv\u003e\n\n\n\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eNovaSeq 6000 Reagent Kits enable tunable output and proven performance for a broad range of applications on the NovaSeq 6000 system. These kits offer:\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eReady-to-use reagent cartridges for streamlined operation \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVarious read lengths to easily adjust output and sample throughput \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMultiple flow cell configurations to support an extensive output range\u003cbr\u003e\n\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\n\n\n\u003cdiv\u003e\n\u003cdiv\u003e\n\n\n\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eIncrease lab efficiency\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eImprovements to the NovaSeq 6000 Reagent Kits include an enhanced reagent chemistry to streamline the workflow and accommodate more complex indexing strategies, an extended reagent shelf life of six months to provide project planning flexibility, and radio-frequency identification (RFID) to ensure reagent traceability and compatibility.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\n\n\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eFlow cell configurations\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eSP and S1 provide the fastest run times and are ideal for smaller batch sizes or in situations where rapid turnaround time is required.\u003c\/p\u003e\n\u003cp\u003eS2 offers a quick, powerful, and cost-effective option for high-throughput applications.\u003c\/p\u003e\n\u003cp\u003eS4 delivers high throughput while enabling cost-effective sequencing across a range of applications and depth of coverage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\n\n\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eAdditional benefits\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eNovaSeq 6000 Reagent Kits v1.5 also provide an improved Q30 quality score compared to the v1.0 reagents, support for unique molecular identifiers (UMIs), and support for whole-genome sequencing with Illumina DNA PCR-Free Library Prep. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina-marketing\/documents\/products\/appnotes\/novaseq-wgs-app-note-770-2017-015.pdf\"\u003eHuman Whole-Genome Sequencing with the NovaSeq 6000 Sequencing System\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina-marketing\/documents\/products\/appnotes\/illumina-dna-pcr-free-wgs-app-note-770-2020-006.pdf\"\u003eHigh-performance whole-genome sequencing with Illumina DNA PCR-Free Prep, Tagmentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina-marketing\/documents\/products\/appnotes\/illumina-dna-pcr-free-wgs-app-note-770-2020-006-chs.pdf\"\u003eChinese (Simplified)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/science-docs.illumina.com\/documents\/Instruments\/novaseq-6000-spec-sheet-html-770-2016-025\/Content\/Source\/Instruments\/NovaSeq\/novaseq-6000-spec-sheet-770-2016-025\/novaseq-system-spec-sheet-html-770-2016-025.html\"\u003eThe NovaSeq 6000 System Specification Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/novaseq-shotgun-metagenomics-app-note-m-na-00010\/novaseq-shotgun-metagenomics-app-note-m-na-00010.pdf\"\u003eShotgun metagenomics with Illumina DNA Prep on the NovaSeq 6000 System\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/ilmn-nanostring-geomx-app-note-m-gl-00223\/illmn-nanostring-geomx-app-note-m-gl-00223.pdf\"\u003eHigh-resolution, high-throughput spatial transcriptomics of complex tissues\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/10x-gene-expression-tech-note-m-gl-00777\/10x-gene-expression-tech-note-m-gl-00777.pdf\"\u003eExplore the transcriptome with single-cell resolution\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.illumina.com\/content\/dam\/illumina\/gcs\/assembled-assets\/marketing-literature\/novaseq-lane-edge-tech-note-m-amr-00104\/novaseq-lane-edge-tech-note-m-amr-00104.pdf\"\u003eImpact of NovaSeq flow cell lane edge integrity on sequencing performance\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSupport Documentation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/support.illumina.com\/sequencing\/sequencing_kits\/novaseq-5000-6000-reagent-kit\/documentation.html\"\u003eNovaSeq 6000 System Documentation\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"http:\/\/support.illumina.com\/sequencing\/sequencing_kits\/novaseq-5000-6000-reagent-kit.html\"\u003eAll NovaSeq 6000 System Support\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Illumina","offers":[{"title":"Default Title","offer_id":46481923965007,"sku":"20014015","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/novaseq-reagent-1-5-web-graphic.png?v=1787578637"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/collections\/7-accessories_4772f70e-9d44-438a-a97d-eccf6344b3bf.png?v=1790863710","url":"https:\/\/www.danyel.co.il\/collections\/ngs-accessories-consumables.oembed","provider":"danyel biotech","version":"1.0","type":"link"}