{"title":"Gel Electrophoresis","description":"\u003cp\u003eSebia agarose gel electrophoresis for clinical laboratories in Israel — the HYDRASYS 2 SCAN FOCUSING system and HYDRAGEL kits: serum and urine protein electrophoresis (PROTEIN(E), β1-β2, HR, 5 PROTEINURIE), HYDRAGEL IF and BENCE JONES immunofixation, HYDRASHIFT daratumumab and isatuximab interference removal, CSF isofocusing for oligoclonal IgG bands, alpha-1 antitrypsin phenotyping and von Willebrand multimer analysis.\u003c\/p\u003e","products":[{"product_id":"hydrasys-2-scan-focusing-agarose-gel-electrophoresis-analyzer-1202","title":"HYDRASYS 2 SCAN FOCUSING Agarose Gel Electrophoresis Analyzer","description":"\u003cp\u003e\u003cstrong\u003eLarge menu with high quality results on gel electrophoresis.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eHYDRASYS 2 SCAN FOCUSING is the “all-in-one” analyser for gel electrophoresis. The system offers analytical solutions for a high level of performance, matching clinical diagnostic requirements.\u003c\/p\u003e \u003cp\u003eThe analyser carries out electrophoresis steps, from sample application to final reading. It is a fast and easy to operate instrument, offering a comprehensive test menu of more than 60 HYDRAGEL programs.\u003c\/p\u003e \u003cp\u003eHYDRASYS 2 SCAN FOCUSING when coupled with the ASSIST is designed to accomodate all workflow requirements; by automating sample preparation to ensure standardisation and traceability.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Quality Results:\u003c\/strong\u003e Have confidence when reporting your patients’ results with best-in-class gel electrophoresis assays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Functional Analyzer:\u003c\/strong\u003e Ability to migrate, stain, \u0026amp; scan gels on one system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowerful Software Solution:\u003c\/strong\u003e PHORESIS Core Software provides tools for interpretation, data \u0026amp; result management and networking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorkflow \u0026amp; Traceability:\u003c\/strong\u003e Automation and standardization of samples preparation with ASSIST.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Menu\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eSerum \u0026amp; Urine Protein Electrophoresis (SPE\/UPE)\u003c\/li\u003e \u003cli\u003eSerum \u0026amp; Urine Immunofixation (IFE, Bence Jones)\u003c\/li\u003e \u003cli\u003eHYDRASHIFT daratumumab\/isatuximab\u003c\/li\u003e \u003cli\u003eCSF and Alpha-1 Antitrypsin by Isofocusing\u003c\/li\u003e \u003cli\u003evon Willebrand Multimers\u003c\/li\u003e \u003cli\u003eIso-Enzymes, B2 transferrin, LDL\/HDL cholesterol, lipoproteins\u003c\/li\u003e \u003cli\u003eHemoglobin Electrophoresis\u003c\/li\u003e \u003cli\u003eAPO E by isofocusing for research use only\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eSample types: Serum, urine, plasma CSF, whole blood\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTest\u003c\/th\u003e\n\u003cth\u003eThroughput (tests\/hour)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cul\u003e \u003cli\u003eFrom 1 to 54 samples per gel\u003c\/li\u003e \u003cli\u003eUp to 3 gels simultaneously (migration, staining and reading)\u003c\/li\u003e \u003cli\u003eOptimized scan reading (precise quantification of all fractions)\u003c\/li\u003e \u003c\/ul\u003e  \u003cul\u003e \u003cli\u003eProteins: up to 108 tests\/hour\u003c\/li\u003e \u003cli\u003eImmunofixations: up to 17 tests\/hour with the IF program\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eReagent and consumables\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003e2 sizes of gel\u003c\/li\u003e \u003cli\u003eStaining reagents on board\u003c\/li\u003e \u003cli\u003eDisposable microporous applicators with 6, 7, 15 \u0026amp; 18 wells to be used to run 1 IF or up to 54 samples in protein electrophoresis\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eErgonomics\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eSmall footprint\u003c\/li\u003e \u003cli\u003ePeltier based temperature control device for fast and accurate temperature regulation\u003c\/li\u003e \u003cli\u003eSimple flexible programming through LCD touch screen interface\u003c\/li\u003e \u003cli\u003e\u0026gt; 60 optimized migration programs\u003c\/li\u003e \u003cli\u003e10 staining\/washing programs\u003c\/li\u003e \u003cli\u003eEasy maintenance\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e1202\u003c\/td\u003e\n\u003ctd\u003eHYDRASYS 2 SCAN FOCUSING\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"Default Title","offer_id":67629798260815,"sku":"1202","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/H2S_web.1.webp?v=1791284860"},{"product_id":"hydragel-protein-e-serum-urine-protein-electrophoresis-gel-kit-4100","title":"HYDRAGEL PROTEIN(E) Serum \u0026 Urine Protein Electrophoresis Gel Kit","description":"\u003cp\u003eSerum Protein Electrophoresis is a well-established technique routinely used in clinical laboratories to screen samples to detect protein abnormalities as monoclonal gammopathies (Multiple Myeloma, MGUS, Waldenström disease) or inflammatory pattern…\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGood gel serum proteins separation in 5 or 6 major proteins fractions:\u003c\/strong\u003e Albumin, Alpha-1, Alpha-2, Beta, Gamma or Albumin, Alpha-1, Alpha-2, Beta-1, Beta-2, Gamma.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear band visualization:\u003c\/strong\u003e for qualitative and relative quantitative analysis for reliable interpretation of serum protein profile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete semi-automated:\u003c\/strong\u003e HYDRASYS 2 SCAN FOCUSING system including sample application, electrophoretic migration, staining, destaining and scanning connected to PHORESIS Software for interpretation, data \u0026amp; result management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh performance proteins Agarose Gel Electrophoresis separation.:\u003c\/strong\u003e by HYDRASYS 2 automation and standardization of samples preparation with ASSIST pipetting station.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eBased on zone electrophoresis separation on agarose gel.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eInternal sensitivity study demonstrated that a monoclonal protein can be detected in a serum at a concentration as low as 17 mg\/dL.\u003c\/li\u003e \u003cli\u003eAccording to the mobility of the monoclonal component and polyclonal background, the sensitivity may vary.\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eTests per gel\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4100\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 7 PROTEIN(E)\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4120\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 15 PROTEIN\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4140\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 30 PROTEIN\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4145\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 54 PROTEIN\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"7","offer_id":67629800292431,"sku":"4100","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"15","offer_id":67629800325199,"sku":"4120","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"30","offer_id":67629800357967,"sku":"4140","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"54","offer_id":67629800390735,"sku":"4145","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydragel-beta1-beta2-serum-urine-protein-electrophoresis-gel-kit-beta1-beta2-separation-4101","title":"HYDRAGEL β1-β2 Serum \u0026 Urine Protein Electrophoresis Gel Kit (β1\/β2 Separation)","description":"\u003cp\u003eSerum Protein Electrophoresis is a well-established technique routinely used in clinical laboratories to screen samples to detect protein abnormalities as monoclonal gammopathies (Multiple Myeloma, MGUS, Waldenström disease) or inflammatory pattern…\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGood gel serum proteins separation in 5 or 6 major proteins fractions:\u003c\/strong\u003e Albumin, Alpha-1, Alpha-2, Beta, Gamma or Albumin, Alpha-1, Alpha-2, Beta-1, Beta-2, Gamma.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear band visualization:\u003c\/strong\u003e for qualitative and relative quantitative analysis for reliable interpretation of serum protein profile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete semi-automated:\u003c\/strong\u003e HYDRASYS 2 SCAN FOCUSING system including sample application, electrophoretic migration, staining, destaining and scanning connected to PHORESIS Software for interpretation, data \u0026amp; result management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh performance proteins Agarose Gel Electrophoresis separation.:\u003c\/strong\u003e by HYDRASYS 2 automation and standardization of samples preparation with ASSIST pipetting station.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eBased on zone electrophoresis separation on agarose gel.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eInternal sensitivity study demonstrated that a monoclonal protein can be detected in a serum at a concentration as low as 17 mg\/dL.\u003c\/li\u003e \u003cli\u003eAccording to the mobility of the monoclonal component and polyclonal background, the sensitivity may vary.\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eTests per gel\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4101\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 7 B1-B2\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4121\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 15 B1-B2\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4141\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 30 B1-B2\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4146\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 54 B1-B2\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"7","offer_id":67629800456271,"sku":"4101","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"15","offer_id":67629800489039,"sku":"4121","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"30","offer_id":67629800521807,"sku":"4141","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"54","offer_id":67629800554575,"sku":"4146","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydragel-hr-high-resolution-protein-electrophoresis-gel-kit-4102","title":"HYDRAGEL HR High-Resolution Protein Electrophoresis Gel Kit","description":"\u003cp\u003e\u003cstrong\u003eProteinuria screening for renal disease.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUrine Protein Electrophoresis is a well-established technique routinely used in clinical laboratories to detect and quantify monoclonal components as Bence Jones proteins (Monoclonal Free Light Chains in urine) or other proteinuria disorder.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGood agarose gel urine proteins separation:\u003c\/strong\u003e in 5 zone proteins indicate by software (from Albumin, to Gamma).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear band visualization:\u003c\/strong\u003e for qualitative and relative quantitative analysis for reliable interpretation of proteinuria screening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete semi-automated:\u003c\/strong\u003e HYDRASYS 2 SCAN FOCUSING system including sample application, electrophoretic migration, staining, destaining and scanning connected to PHORESIS Software for interpretation, data \u0026amp; result management.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eBased on zone electrophoresis separation on agarose gel.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUrine\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eMonoclonal protein limit detection is about 0.017 g\/dL.\u003c\/li\u003e \u003cli\u003eAccording to the position of the monoclonal component and polyclonal background in the gamma zone, the detection limit may vary.\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eTests per gel\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4102\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 7 HR ACID VIOLET\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4122\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 15 HR\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"7","offer_id":67629800783951,"sku":"4102","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"15","offer_id":67629800816719,"sku":"4122","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydragel-5-proteinurie-urine-protein-electrophoresis-gel-kit-4115","title":"HYDRAGEL 5 PROTEINURIE Urine Protein Electrophoresis Gel Kit","description":"\u003cp\u003e\u003cstrong\u003eProteinuria screening for renal disease.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUrine Protein Electrophoresis is a well-established technique routinely used in clinical laboratories to detect and quantify monoclonal components as Bence Jones proteins (Monoclonal Free Light Chains in urine) or other proteinuria disorder.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGood agarose gel urine proteins separation:\u003c\/strong\u003e in 5 zone proteins indicate by software (from Albumin, to Gamma).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear band visualization:\u003c\/strong\u003e for qualitative and relative quantitative analysis for reliable interpretation of proteinuria screening.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete semi-automated:\u003c\/strong\u003e HYDRASYS 2 SCAN FOCUSING system including sample application, electrophoretic migration, staining, destaining and scanning connected to PHORESIS Software for interpretation, data \u0026amp; result management.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eBased on zone electrophoresis separation on agarose gel.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUrine\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eMonoclonal protein limit detection is about 0.017 g\/dL.\u003c\/li\u003e \u003cli\u003eAccording to the position of the monoclonal component and polyclonal background in the gamma zone, the detection limit may vary.\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e4115\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 5 PROTEINURIA\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"Default Title","offer_id":67629800849487,"sku":"4115","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydragel-if-serum-urine-immunofixation-gel-kit-4801","title":"HYDRAGEL IF Serum \u0026 Urine Immunofixation Gel Kit","description":"\u003cp\u003e\u003cstrong\u003eIdentification of monoclonal proteins by agarose gel electrophoresis.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eImmunofixation is an immunological method for detection and identification of monoclonal proteins in serum and urine. After the separation of serum and urine proteins according to their charge, the gel is incubated with different specific antisera. The gel is then processed in order to remove the antisera excess prior to the final staining step. The gel is interpreted visually to type all immunoglobulins.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGood performance:\u003c\/strong\u003e for proteins separation and identification of monoclonal component in serum and urine in agarose gel method.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear band visualisation:\u003c\/strong\u003e in serum and urine for quick identification of suspect monoclonal proteins IgG, IgA, IgM, Kappa (κ) or Lambda (λ) and free light chains involved in gammopathy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh quality, ready to use antisera:\u003c\/strong\u003e for optimal reaction performance and accurate monoclonal component identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete semi-automated:\u003c\/strong\u003e HYDRASYS 2 SCAN FOCUSING system including sample application, electrophoretic migration, immunofixation, staining, destaining and scanning connected to PHORESIS Software for data \u0026amp; result management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicate HYDRAGEL BENCE JONES kits:\u003c\/strong\u003e for detection of very small monoclonal components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest principle\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eThe HYDRAGEL IF assay is based on the principle of agarose gel electrophoresis followed by immunofixation.\u003c\/li\u003e \u003cli\u003eAfter the separation of serum or urine proteins according to their charge, the gel is incubated with different specific antisera for characterization of monoclonal component involved in the gammopathy.\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum \u0026amp; Urine\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eThe minimal detection limit for monoclonal immunoglobulins is about 120 mg\/L for gels stained with acid violet and about 250 mg\/L for gels stained with amidoblack.\u003c\/li\u003e \u003cli\u003eAccording to the mobility of the monoclonal component and polyclonal background, the sensitivity may vary.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eInternal sensitivity study demonstrated that a Bence Jones protein can be detected in a serum at a concentration:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eas low as 20 mg\/L with anti-free \u0026amp; bound light chains antisera\u003c\/li\u003e \u003cli\u003eas low as 50 mg\/L with anti-free light chains antisera\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eTests per gel\u003c\/th\u003e\n\u003cth\u003eMask\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4801\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 1 IF (MS)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eStandard Mask (SM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4301\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 1IF (VIOLET) (M.D)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eDynamic Mask (DM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4802\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 2 IF (MS)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eStandard Mask (SM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4302\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 2IF (VIOLET) (M.D)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eDynamic Mask (DM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4804\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 4IF ACID VIOLET (MS)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eStandard Mask (SM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4304\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 4IF (VIOLET) (M.D)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eDynamic Mask (DM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4809\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 9 IF (MS)\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003eStandard Mask (SM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4309\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 9IF (VIOLET) (M.D)\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003eDynamic Mask (DM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cem\u003e* SM: Standard Mask ** DM: Dynamic Mask\u003c\/em\u003e\u003c\/p\u003e","brand":"Sebia","offers":[{"title":"1 \/ Standard Mask (SM)","offer_id":67629801078863,"sku":"4801","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"1 \/ Dynamic Mask (DM)","offer_id":67629801111631,"sku":"4301","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"2 \/ Standard Mask (SM)","offer_id":67629801144399,"sku":"4802","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"2 \/ Dynamic Mask (DM)","offer_id":67629801177167,"sku":"4302","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"4 \/ Standard Mask (SM)","offer_id":67629801209935,"sku":"4804","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"4 \/ Dynamic Mask (DM)","offer_id":67629801242703,"sku":"4304","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"9 \/ Standard Mask (SM)","offer_id":67629801275471,"sku":"4809","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"9 \/ Dynamic Mask (DM)","offer_id":67629801308239,"sku":"4309","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydragel-bence-jones-urine-immunofixation-gel-kit-free-light-chains-4821","title":"HYDRAGEL BENCE JONES Urine Immunofixation Gel Kit (Free Light Chains)","description":"\u003cp\u003e\u003cstrong\u003eIdentification of monoclonal proteins by agarose gel electrophoresis.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eImmunofixation is an immunological method for detection and identification of monoclonal proteins in serum and urine. After the separation of serum and urine proteins according to their charge, the gel is incubated with different specific antisera. The gel is then processed in order to remove the antisera excess prior to the final staining step. The gel is interpreted visually to type all immunoglobulins.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGood performance:\u003c\/strong\u003e for proteins separation and identification of monoclonal component in serum and urine in agarose gel method.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClear band visualisation:\u003c\/strong\u003e in serum and urine for quick identification of suspect monoclonal proteins IgG, IgA, IgM, Kappa (κ) or Lambda (λ) and free light chains involved in gammopathy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh quality, ready to use antisera:\u003c\/strong\u003e for optimal reaction performance and accurate monoclonal component identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete semi-automated:\u003c\/strong\u003e HYDRASYS 2 SCAN FOCUSING system including sample application, electrophoretic migration, immunofixation, staining, destaining and scanning connected to PHORESIS Software for data \u0026amp; result management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicate HYDRAGEL BENCE JONES kits:\u003c\/strong\u003e for detection of very small monoclonal components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest principle\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eThe HYDRAGEL IF assay is based on the principle of agarose gel electrophoresis followed by immunofixation.\u003c\/li\u003e \u003cli\u003eAfter the separation of serum or urine proteins according to their charge, the gel is incubated with different specific antisera for characterization of monoclonal component involved in the gammopathy.\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum \u0026amp; Urine\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cul\u003e \u003cli\u003eThe minimal detection limit for monoclonal immunoglobulins is about 120 mg\/L for gels stained with acid violet and about 250 mg\/L for gels stained with amidoblack.\u003c\/li\u003e \u003cli\u003eAccording to the mobility of the monoclonal component and polyclonal background, the sensitivity may vary.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eInternal sensitivity study demonstrated that a Bence Jones protein can be detected in a serum at a concentration:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eas low as 20 mg\/L with anti-free \u0026amp; bound light chains antisera\u003c\/li\u003e \u003cli\u003eas low as 50 mg\/L with anti-free light chains antisera\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eTests per gel\u003c\/th\u003e\n\u003cth\u003eMask\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4821\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 1 BENCE JONES (MS)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eStandard Mask (SM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4321\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 1 BENCE JONES (M.D)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eDynamic Mask (DM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4822\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 2 BENCE JONES (MS)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eStandard Mask (SM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4322\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 2 BENCE JONES (M.D)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003eDynamic Mask (DM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4824\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 4 BENCE JONES (MS)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eStandard Mask (SM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4324\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 4 BENCE JONES (M.D)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eDynamic Mask (DM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cem\u003e* SM: Standard Mask ** DM: Dynamic Mask\u003c\/em\u003e\u003c\/p\u003e","brand":"Sebia","offers":[{"title":"1 \/ Standard Mask (SM)","offer_id":67629801341007,"sku":"4821","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"1 \/ Dynamic Mask (DM)","offer_id":67629801373775,"sku":"4321","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"2 \/ Standard Mask (SM)","offer_id":67629801406543,"sku":"4822","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"2 \/ Dynamic Mask (DM)","offer_id":67629801439311,"sku":"4322","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"4 \/ Standard Mask (SM)","offer_id":67629801472079,"sku":"4824","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"4 \/ Dynamic Mask (DM)","offer_id":67629801504847,"sku":"4324","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydragel-csf-isofocusing-oligoclonal-igg-bands-kit-cns-local-igg-synthesis-4353","title":"HYDRAGEL CSF ISOFOCUSING Oligoclonal IgG Bands Kit (CNS Local IgG Synthesis)","description":"\u003cp\u003e\u003cstrong\u003eThe gold standard assay to objectively detect CNS local IgG synthesis in multiple sclerosis.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePresence of intrathecal IgG suggests inflammatory disease of the Central Nervous System, such as caused by multiple sclerosis (MS).\u003c\/p\u003e \u003cp\u003eThe HYDRAGEL CSF ISOFOCUSING kit used on the HYDRASYS 2 SCAN FOCUSING instrument provides qualitative detection and immunological characterization of IgG oligoclonal banding in human CSF (Cerebro Spinal Fluid) and serum. The semi-automated HYDRASYS instrument enables migration, immunofixation and direct detection on agarose gels, in order to obtain IgG profiles for qualitative analysis.\u003c\/p\u003e \u003cp\u003eThe main recommendations of European Consensus Report for Multiple Sclerosis diagnosis are:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eIsoelectrofocusing (IEF) on Agarose gel for immunoglobulins separation\u003c\/li\u003e \u003cli\u003eUse of non-concentrated CSF material\u003c\/li\u003e \u003cli\u003eSimultaneous analysis of the patient’s serum and CSF\u003c\/li\u003e \u003cli\u003eIdentical IgG concentration in paired CSF-serum samples\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eThe presence of CSF oligoclonal bands only, characterizing local IgG synthesis, tightly correlates with the diagnosis of Multiple Sclerosis. Their presence provides useful information when in agreement with the other clinical investigations.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccurate Diagnosis of inflammatory disease of the CNS:\u003c\/strong\u003e Sensitivity increased about a 100-fold compared to standard immunofixation thanks to the detection with enzyme labelled antibodies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Method:\u003c\/strong\u003e Clear oligoclonal band visualization for a reliable interpretation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFaster result:\u003c\/strong\u003e Simple step-by-step procedure without membrane transfer for 3 hours of turnaround time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance with international consensus:\u003c\/strong\u003e HYDRAGEL CSF ISOFOCUSING meets all requirements needed to objectively detect CNS local IgG synthesis in multiple sclerosis.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe HYDRAGEL CSF ISOFOCUSING assay is based on the principle of agarose gel isoelectrofocusing followed by immunofixation. The patient’s serum and CSF samples are analysed in parallel to compare the IgG distribution.\u003c\/p\u003e \u003cul\u003e \u003cli\u003ePrior to performing the test, it is mandatory to quantify the IgG’s in both liquids, in order to adjust the IgG concentration at the same level in CSF and serum.\u003c\/li\u003e \u003cli\u003eAfter the protein separation according to their isoelectric point, the gel is directly incubated with a peroxidase labelled anti-IgG antiserum, with no need for a membrane blotting step.\u003c\/li\u003e \u003cli\u003eThen, the gel is processed to remove unbound proteins before the enzymatic reaction.\u003c\/li\u003e \u003cli\u003eFinally, the gel is visually evaluated.\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum and CSF samples are performed in parallel for each patient to compare IgG distribution as recommended by the European consensus.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003e2 stages-protocol: Isoelectrofocalisation and Immunofixation for an optimized result\u003c\/li\u003e \u003cli\u003eEnhanced software with high voltage monitoring\u003c\/li\u003e \u003cli\u003eFull traceability and positive ID obtained by connecting the HYDRASYS instrument to the ASSIST pipetting station\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eTests per gel\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4353\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 3 CSF ISOFOCUSING\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4355\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 9 CSF ISOFOCUSING\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"3","offer_id":67629801734223,"sku":"4353","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"9","offer_id":67629801766991,"sku":"4355","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydragel-18-a1at-isofocusing-alpha-1-antitrypsin-phenotyping-kit-4357","title":"HYDRAGEL 18 A1AT ISOFOCUSING Alpha-1 Antitrypsin Phenotyping Kit","description":"\u003cp\u003e\u003cstrong\u003eThe gold standard assay for the alpha 1-antitrypsin (A1AT) phenotype testing.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe most common method to detect A1AT deficiency is protein phenotyping using isoelectric focusing.\u003c\/p\u003e \u003cp\u003eThe HYDRAGEL 18 A1AT ISOFOCUSING kit used on the HYDRASYS 2 SCAN FOCUSING instrument provides qualitative detection of the different phenotypes of the A1AT in human serum.\u003c\/p\u003e \u003cp\u003eThe semi-automated HYDRASYS 2 instrument enables migration, immunofixation and direct detection on agarose gels, to obtain A1AT profiles for qualitative analysis.\u003c\/p\u003e \u003cp\u003ePhenotyping results in conjunction with clinical findings and other laboratory assays aid in the diagnosis of Alpha 1-antitrypsin deficiency.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccurate Diagnosis:\u003c\/strong\u003e 100% of concordance with another agarose gel isocelectric focusing and in agreement with the different phenotypes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Method:\u003c\/strong\u003e Clear band visualization for a reliable interpretation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast result:\u003c\/strong\u003e Simple step-by-step procedure without membrane transfer for 2.5 hours of turnaround time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesting is part of algorithms:\u003c\/strong\u003e HYDRAGEL 18 A1AT ISOFOCUSING is included in both screening and diagnostic algorithms to provide clinicians with phenotype of A1AT proteins secreted in blood circulation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe HYDRAGEL 18 A1AT ISOFOCUSING assay is based on the principle of agarose gel isoelectrofocusing followed by immunofixation.\u003c\/p\u003e \u003cul\u003e \u003cli\u003eAfter the protein separation according to their isoelectric point, the gel is directly incubated with a peroxidase labelled anti-A1AT antiserum with no need for a membrane blotting step.\u003c\/li\u003e \u003cli\u003eThen, the gel is processed in order to remove unbound proteins before the enzymatic reaction.\u003c\/li\u003e \u003cli\u003eFinally, the gel is visually evaluated.\u003c\/li\u003e \u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eHuman serum samples can be used with HYDRAGEL 18 A1AT ISOFOCUSING.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003e2 stages-protocol: Isoelectrofocalisation and Immunofixation for an optimized result\u003c\/li\u003e \u003cli\u003eA1AT controls (MM, MZ and MS) are included in each series of analysis to quickly identify M, S and Z phenotypes.\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e4357\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 18 A1AT ISOFOCUSING W\/O AS\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"Default Title","offer_id":67629801799759,"sku":"4357","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydragel-von-willebrand-multimers-gel-electrophoresis-kit-4359","title":"HYDRAGEL von WILLEBRAND MULTIMERS Gel Electrophoresis Kit","description":"\u003cp\u003e\u003cstrong\u003eMultimer assay simplified.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003evon Willebrand disease (vWD) is a genetic bleeding disorder caused by missing or defective von Willebrand factor (vWF).\u003cbr\u003e Since von Willebrand disease (vWD) is a complex disease, its diagnosis requires a large panel of tests for an accurate diagnosis and classification of vWD. Multimer analysis is an integral part of the diagnostic process and an essential information for the clinicians for an optimal patient management.\u003c\/p\u003e \u003cp\u003eHYDRAGEL von WILLEBRAND MULTIMERS kit is designed for the detection of abnormalities in the vWF multimers distribution related to a haemorrhagic diathesis. The test allows to assess the overall size distribution of von Willebrand factor multimers in human plasma using agarose gel electrophoresis and immunofixation, with the semi-automated HYDRASYS 2 instrument.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSemi-automated test:\u003c\/strong\u003e providing standardised and reproducible results.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimplified technique:\u003c\/strong\u003e making this test accessible to any laboratory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWithin-day results:\u003c\/strong\u003e compared to in house tests delivering results in 4-5 days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTraceability of the result:\u003c\/strong\u003e with densitometry-based interpretations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eHYDRAGEL von WILLEBRAND MULTIMERS allows separating small, intermediate, and large molecular weight multimers.\u003c\/p\u003e \u003cp\u003eThe assay is carried out in two stages:\u003c\/p\u003e \u003cul\u003e \u003cli\u003eSample pre-treatment followed by an electrophoresis done in SDS agarose gel to separate proteins according to their molecular weight,\u003c\/li\u003e \u003cli\u003edirect immunofixation of multimers in the gel using anti-human vWF antibody followed by immunoenzyme staining to visualize the different multimers.\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003eThe semi-automated HYDRASYS 2 SCAN FOCUSING instrument performs all the steps needed to obtain gels ready for visual and densitometry-based interpretations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePlasma samples\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e \u003cli\u003eExcellent reproducibility\u003c\/li\u003e \u003cli\u003eAll multimer sizes\u003c\/li\u003e \u003cli\u003eDensitometry helps for results interpretation\u003c\/li\u003e \u003cli\u003ePatient’s profile overlayed with a normal control\u003c\/li\u003e \u003c\/ul\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003cth\u003eTests per gel\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4359\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 5 VON WILLEBRAND MULT\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4360\u003c\/td\u003e\n\u003ctd\u003eHYDRAGEL 11 VON WILLEBRAND MULT\u003c\/td\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"5","offer_id":67629802094671,"sku":"4359","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"11","offer_id":67629802127439,"sku":"4360","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/zoom_gel_web_473x473_4a77dc63-6224-4249-b43f-a14bca1d52cc.png?v=1791291281"},{"product_id":"hydrashift-2-4-daratumumab-immunofixation-interference-kit-4639","title":"HYDRASHIFT 2\/4 daratumumab Immunofixation Interference Kit","description":"\u003cp\u003eHYDRASHIFT 2\/4 daratumumab removes the daratumumab interference from serum immunofixation, so the therapeutic monoclonal antibody is no longer mistaken for a residual M-protein in treated myeloma patients. 20 tests per kit, run on HYDRASYS.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnique shift technology:\u003c\/strong\u003e HYDRASHIFT daratumumab and HYDRASHIFT isatuximab avoid daratumumab or isatuximab interference on HYDRAGEL IF tests.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrust in the results:\u003c\/strong\u003e HYDRASHIFT reduce the risk of incorrect IF interpretation to improve therapy monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy to implement:\u003c\/strong\u003e Fully integrated into IF protocol without sample pre-treatment for a standardized process compliant to IMWG guidelines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFollow IMWG guidelines:\u003c\/strong\u003e Process compliant to IMWG guidelines to assess response to treatment in patient with Multiple Myeloma.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eHYDRASHIFT is an immunofixation procedure performed on HYDRAGEL IF 2\/4 gel and based on the creation of a mAb\/ anti mAb immune complex shift mAb drug (daratumumab or isatuximab) in alpha zone.\u003c\/p\u003e \u003cp\u003eThis complex is visible in the IgG and kappa immunofixation tracks. A negative HYDRASHIFT result demonstrates the absence of endogenous M-protein.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cp\u003eThe limit of immune complex visualized is 0.3 g\/L.\u003c\/p\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e4639\u003c\/td\u003e\n\u003ctd\u003eHYDRASHIFT 2\/4 DARATUMUMAB (20)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"Default Title","offer_id":67629802160207,"sku":"4639","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/hydrahisft_visuel_web1.webp?v=1791284904"},{"product_id":"hydrashift-2-4-isatuximab-immunofixation-interference-kit-4642","title":"HYDRASHIFT 2\/4 isatuximab Immunofixation Interference Kit","description":"\u003cp\u003eHYDRASHIFT 2\/4 isatuximab removes the isatuximab interference from serum immunofixation, so the therapeutic monoclonal antibody is no longer mistaken for a residual M-protein in treated myeloma patients. 40 tests per kit, run on HYDRASYS.\u003c\/p\u003e\u003ch2\u003eKey Benefits\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnique shift technology:\u003c\/strong\u003e HYDRASHIFT daratumumab and HYDRASHIFT isatuximab avoid daratumumab or isatuximab interference on HYDRAGEL IF tests.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrust in the results:\u003c\/strong\u003e HYDRASHIFT reduce the risk of incorrect IF interpretation to improve therapy monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy to implement:\u003c\/strong\u003e Fully integrated into IF protocol without sample pre-treatment for a standardized process compliant to IMWG guidelines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFollow IMWG guidelines:\u003c\/strong\u003e Process compliant to IMWG guidelines to assess response to treatment in patient with Multiple Myeloma.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eMain Characteristics\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eTest Principle\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eHYDRASHIFT is an immunofixation procedure performed on HYDRAGEL IF 2\/4 gel and based on the creation of a mAb\/ anti mAb immune complex shift mAb drug (daratumumab or isatuximab) in alpha zone.\u003c\/p\u003e \u003cp\u003eThis complex is visible in the IgG and kappa immunofixation tracks. A negative HYDRASHIFT result demonstrates the absence of endogenous M-protein.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eSerum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePerformances\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e \u003cp\u003eThe limit of immune complex visualized is 0.3 g\/L.\u003c\/p\u003e\u003ch2\u003eOrdering Information\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCat. No.\u003c\/th\u003e\n\u003cth\u003eProduct\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003e4642\u003c\/td\u003e\n\u003ctd\u003eHYDRASHIFT 2\/4 ISATUXIMAB (40)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Sebia","offers":[{"title":"Default Title","offer_id":67629802356815,"sku":"4642","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/hydrahisft_visuel_web1.webp?v=1791284904"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/collections\/zoom_gel_web_473x473_56a6ced8-ade5-4d2a-8a03-aef855316a94.png?v=1791291222","url":"https:\/\/www.danyel.co.il\/collections\/gel-electrophoresis.oembed","provider":"danyel biotech","version":"1.0","type":"link"}