{"title":"DLS","description":null,"products":[{"product_id":"wyatt-dynapro-nanostar-ii-dynamic-light-scattering-ins","title":"DynaPro NanoStar II Dynamic Light Scattering Instrument","description":"\u003cspan\u003e\u003cp align=\"center\"\u003e\u003cimg src=\"\/wp-content\/uploads\/2022\/01\/NanoStar_Hero_Display.jpg\" alt=\"DynaPro NanoStar, dls instrument, dynamic light scattering instrument\" title=\"DynaPro NanoStar II\" width=\"50%\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\u003c\/span\u003e\n\u003cp\u003eTraditional dynamic light scattering, just better.\u003c\/p\u003e\n\u003cp\u003eUnique cuvette-based DLS\u003c\/p\u003e\n\u003cp\u003eThe DynaPro NanoStar II is a unique cuvette-based DLS instrument used for the analysis of proteins, gene therapy vectors, viruses and virus-like particles, promiscuous inhibitors, micelles, liposomes, lipid and metallic nanoparticles, and more. To accommodate scarce and precious samples, specially designed quartz cuvettes afford robust, accurate measurements with as little as 2 µL of solution, while our proprietary disposable cuvettes provide comparable sensitivity with as little as 4 µL!\u003c\/p\u003e\n\u003chr class=\"no_line\" style=\"margin: 0 auto 10px auto\"\u003e\n\u003cp\u003eWalk-up operation with DYNAMICS Touch\u003csup\u003e™\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003eThe NanoStar is the only DLS instrument to provide a fully integrated, walk-up measurement experience. No need to boot up your lab PC, launch the DLS software, connect to the instrument and worry about where your data files are stored. DYNAMICS Touch is an intuitive—yet capable—DLS measurement app that resides right on the NanoStar. \nVia the full-size touch screen display, \u003ca href=\"https:\/\/www.wyatt.com\/products\/software\/dynamics-touch.html\"\u003eDYNAMICS Touch\u003c\/a\u003e guides you through the entire setup and measurement process. It tells you if the data quality is sufficient for confidence in the results, and displays them instantly. Data files and concise PDF reports can be stored on the instrument, transferred via the network or downloaded to a flash drive. You can even send the report to your phone!\u003c\/p\u003e\n\u003cp\u003eFull-featured analyses with DYNAMICS\u003csup\u003e™\u003c\/sup\u003e\u003c\/p\u003e\n\u003ca href=\"https:\/\/www.wyatt.com\/products\/software\/dynamics.html\"\u003eDYNAMICS\u003c\/a\u003e is our powerful PC-based, comprehensive software package for collecting, analyzing, and reporting batch dynamic and static light scattering data. It performs advanced analyses and compares multiple data files to identify trends and statistics. DYNAMICS can control the NanoStar and acquire data directly, or read in DYNAMICS Touch data files.\n\u003cp\u003eDYNAMICS is offered with a 21 CFR Part 11 compliant Security Pack option, enabling the use of the DynaPro NanoStar in a GMP environment for quality control or at-line process monitoring.\u003c\/p\u003e\n\u003cp\u003eSize and beyond\u003c\/p\u003e\n\u003cdiv class=\"column one-second\" style=\"padding-right:10px\"\u003e\n\u003cp\u003eCoupled with the versatile and user-friendly \u003ca href=\"https:\/\/www.wyatt.com\/products\/software\/dynamics.html\"\u003eDYNAMICS\u003csup\u003e™\u003c\/sup\u003e software\u003c\/a\u003e and \u003ca href=\"https:\/\/www.wyatt.com\/products\/software\/dynamics-touch.html\"\u003eDYNAMICS Touch\u003csup\u003e™\u003c\/sup\u003e\u003c\/a\u003e on-board app, the NanoStar may be utilized to measure not just size, size distributions, particle concentration and weight-average molar mass, but also solution properties relevant to sample stability: the second virial coefficient \n  (\u003ci\u003eA\u003c\/i\u003e\u003csub\u003e2\u003c\/sub\u003e or \u003ci\u003eB\u003c\/i\u003e\u003csub\u003e22\u003c\/sub\u003e), the diffusion interaction parameter (\u003ci\u003ek\u003c\/i\u003e\u003csub\u003eD\u003c\/sub\u003e), \u003ca href=\"https:\/\/www.wyatt.com\/solutions\/measuring-turbidity-opalescence.html\"\u003eturbidity or opalescence\u003c\/a\u003e and the temperature of protein melting or aggregation onset (\u003ci\u003eT\u003c\/i\u003e\u003csub\u003em\u003c\/sub\u003e, \u003ci\u003eT\u003c\/i\u003e\u003csub\u003eonset\u003c\/sub\u003e).\u003c\/p\u003e\n\u003cp\u003eCuvette, and yet...\u003c\/p\u003e\n\u003cp\u003e... still another feature unique to the NanoStar: the \u003ca href=\"https:\/\/store.wyatt.com\/shop\/udawn\/udawn3\/dls-compatibility-kit\/\"\u003eoptical fiber pickup\u003c\/a\u003e may be coupled to any of Wyatt's on-line MALS detectors - the \n  \u003ca href=\"https:\/\/www.wyatt.com\/products\/instruments\/dawn-multi-angle-light-scattering-detector.html\"\u003eDAWN\u003csup\u003e™\u003c\/sup\u003e\u003c\/a\u003e or \n  \u003ca href=\"https:\/\/www.wyatt.com\/products\/instruments\/minidawn-multi-angle-light-scattering-detector-sec-mals.html\"\u003eminiDAWN\u003csup\u003e™\u003c\/sup\u003e\u003c\/a\u003e - to add on-line DLS measurements in the same detection volume as \u003ca href=\"https:\/\/www.wyatt.com\/solutions\/techniques\/sec-mals-molar-mass-size-multi-angle-light-scattering.html\"\u003eSEC-MALS\u003c\/a\u003e or \u003ca href=\"https:\/\/www.wyatt.com\/solutions\/techniques\/fff-mals-characterization-of-nanoparticles-colloids-macromolecules.html\"\u003eFFF-MALS\u003c\/a\u003e measurements. \u003c\/p\u003e\n\u003cp\u003eCombining numerous benefits, the NanoStar is an unparalleled cuvette-based DLS detector. For higher productivity, consider the \n  \u003ca href=\"https:\/\/www.wyatt.com\/products\/instruments\/dynapro-dynamic-light-scattering-plate-reader.html\"\u003eDynaPro™\u003csup\u003e™\u003c\/sup\u003e Plate Reader\u003c\/a\u003e, the only commercially available DLS plate reader measuring \u003ci\u003ein situ\u003c\/i\u003e for high-throughput screening of thousands of conditions per day in industry-standard microwell plates.\u003c\/p\u003e\n\u003cp\u003eKey features\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDYNAMICS Touch on-board app for walk-up operation\u003c\/li\u003e\n\u003cli\u003e\n\u003ci\u003eR\u003c\/i\u003e\u003csub\u003eh\u003c\/sub\u003e from 0.2 nm - 1000 nm\u003c\/li\u003e\n\u003cli\u003eTemperature from -10 °C to +120 °C\u003c\/li\u003e\n\u003cli\u003eMolecular weight from 300 Da to 1 MDa\u003c\/li\u003e\n\u003cli\u003eTurbidity from 1 to 80 NTU\u003c\/li\u003e\n\u003cli\u003eSeparate, optimized SLS and DLS detection channels\u003c\/li\u003e\n\u003cli\u003eAuto-attenuation over five orders of magnitude\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVersatile, high-quality options\u003c\/p\u003e\n\u003cp\u003eMake measurements in super-high-quality quartz cuvettes with as little as 2 µL of sample, aqueous or organic solvents, over the entire, extended temperature range. This cuvette incorporates a solvent reservoir to prevent sample evaporation over high-temperature or extended analyses.\u003c\/p\u003e\n\u003cp\u003eOur proprietary disposable cuvettes nearly match the optical quality of quartz yet require only 4 µL of sample, aqueous or select polar solvents. For convenience, larger-volume \u003ca href=\"https:\/\/store.wyatt.com\/?product_cat=\u0026amp;post_type=product\u0026amp;s=cuvette\"\u003equartz\u003c\/a\u003e and disposable cuvettes are also available.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"column one-second\"\u003e\n\u003cp align=\"center\"\u003e\u003ca href=\"https:\/\/www.wyatt.com\/wp-content\/uploads\/2022\/01\/Dashboard-Page-Conc.jpg\" rel=\"lightbox\"\u003e\u003cimg alt=\"DYNAMICS Touch\" src=\"https:\/\/www.wyatt.com\/wp-content\/uploads\/2022\/01\/Dashboard-Page-Conc.jpg\" width=\"80%\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp align=\"center\" style=\"color:#075c97;font-size:14px\"\u003eClick to enlarge.\u003c\/p\u003e\n\u003cp align=\"center\"\u003e\u003cimg alt=\"Cuvettes\" src=\"https:\/\/www.wyatt.com\/wp-content\/uploads\/2021\/10\/Cuvettes.jpg\" style=\"padding-left:20px\" width=\"80%\"\u003e\u003c\/p\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003cp align=\"center\"\u003e\u003cimg alt=\"DYNAMICS Touch\" src=\"https:\/\/www.wyatt.com\/wp-content\/uploads\/2022\/01\/Over-Shoulder-Touch-Screen.jpg\" style=\"padding-left:20px\" width=\"80%\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize Range (Radius)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1000 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatic Scattering Molecular Weight Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 Da to 10 MDa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTurbidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 80 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParticle Concentration Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1x10 to 1x 10 (dependent on size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/mL of 14.4 kDa lysozyme in PBS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 °C to +120 °C Maximum ramp rate 15 °C\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Cells\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuartz cuvette: 2 μL or 45 μL, Disposable cuvette (cyclic olefin copolymer), generic 4 mL quartz\nand disposable cuvettes (with adapter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Sample Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 μL in quartz cuvette; 4 μL in disposable cuvette\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLaser Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e658 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLaser Power Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable 10% to 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScattering Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOptical Fiber\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Detectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLaser monitor for active stabilization; Forward monitor measures  transmitted light for turbidance and laser\/cell diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Acquisition Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 3600 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCorrelator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e512 channel, 100 nsec sampling time in a multi-tau layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57 cm (L) x 36 cm (W) x 20 cm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTBD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.wyatt.com\/products\/nanostar-brochure-request.html\" target=\"_blank\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Wyatt Technology","offers":[{"title":"Standalone \/ 2 µL \/ Active USB","offer_id":46488410292303,"sku":"WDN-0100","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Standalone \/ 2 µL \/ Disabled USB","offer_id":46488410325071,"sku":"WDN-0101","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Standalone \/ 45 µL \/ Active USB","offer_id":46488410357839,"sku":"WDN-0200","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Standalone \/ 45 µL \/ Disabled USB","offer_id":46488410390607,"sku":"WDN-0201","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Standalone \/ To be specified \/ To be specified","offer_id":46488410423375,"sku":"WDN","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"With MALS interface \/ 2 µL \/ Active USB","offer_id":46488410456143,"sku":"WDNM-0100","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"With MALS interface \/ 2 µL \/ Disabled USB","offer_id":46488410488911,"sku":"WDNM-0101","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"With MALS interface \/ 45 µL \/ Active USB","offer_id":46488410521679,"sku":"WDNM-0200","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"With MALS interface \/ 45 µL \/ Disabled USB","offer_id":46488410554447,"sku":"WDNM-0201","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"With MALS interface \/ To be specified \/ To be specified","offer_id":46488410587215,"sku":"WDNM","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/NanoStar_Hero_Display.jpg?v=1787675364"},{"product_id":"wyatt-dynapro-zetastar-dls-els-instrument","title":"DynaPro ZetaStar DLS \u0026 ELS Instrument","description":"\u003cbr\u003e\n\u003cp\u003eWalk-up or automated measurements of size,\nparticle concentration and zeta potential\u003c\/p\u003e\n\u003cp\u003eMulti-measurement capabilities in one instrument\u003c\/p\u003e\n\u003cp\u003eThe DynaPro\u003csup\u003e™\u003c\/sup\u003e ZetaStar combines dynamic, electrophoretic and static light scattering to characterize nanoparticle suspensions and macromolecular solutions. It is simple to use, but a powerful tool that quickly delivers size and polydispersity, zeta potential, particle concentration, molar mass, and turbidity\/opalescence for molecules that range in size from angstroms to microns. Analyze and quantify viral vectors, vesicles, lipid nanoparticles, inorganic nanoparticles, nanoemulsions, polymers, peptides, proteins, nucleic acids, and more. \u003c\/p\u003e\n\u003cp\u003eAutomated nanoparticle characterization\u003c\/p\u003e\n\u003cp\u003eThe DynaPro™ ZetaStar Instrument stands apart from other light scattering devices with its unique ability to fully automate size and zeta potential measurements. When paired to an HPLC autosampler, achieve precise, unattended analysis on up to 96 samples in a single run—saving time and reducing variability.\u003c\/p\u003e\n\u003cp\u003eWalk-up operation with DYNAMICS Touch\u003csup\u003e™\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003eDesigned for casual and non-expert users, \u003ca href=\"https:\/\/www.wyatt.com\/products\/software\/dynamics-touch.html\"\u003eDYNAMICS Touch\u003c\/a\u003e is an intuitive—yet capable—multi-measurement app that resides right on the ZetaStar. Via the touch screen display, DYNAMICS Touch guides measurement setup and data collection. Data quality indicators provide confidence in the results as well as insight to help improve future measurements. Results are instantly displayed on the ZetaStar, while data files and concise PDF reports can be stored on the instrument, transferred via the network or downloaded to a flash drive. You can even send the report to your phone!\u003c\/p\u003e\n\u003cp\u003eFull-featured analyses with DYNAMICS™\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.wyatt.com\/products\/software\/dynamics.html\"\u003eDYNAMICS\u003c\/a\u003e is our powerful PC-based, comprehensive software package for collecting, analyzing, and reporting dynamic, static and electrophoretic light scattering data. It performs advanced analyses and compares multiple data files to identify trends and compile statistics. DYNAMICS can control the ZetaStar and acquire data directly, run a series of automated experiments with an autosampler, or read in DYNAMICS Touch data files.\u003c\/p\u003e\n\u003cp\u003eDYNAMICS is offered with a 21 CFR Part 11 compliant Security Pack option, enabling the use of the ZetaStar in a GMP environment for quality control or at-line process monitoring.\u003c\/p\u003e\n\u003cdiv class=\"column one-second mobile-one\"\u003e\u003cdiv class=\"mcb-column-inner\"\u003e\n\u003cp style=\"color:#075c97;\"\u003eMore than just your typical zeta potential detector\u003c\/p\u003e\n\u003cp\u003eUnique among zeta potential detectors, the ZetaStar offers sensitive and robust DLS, ELS, and SLS measurements both in cuvettes and in automation using a flow cell.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eDLS\/ELS\u003c\/b\u003e: The ZetaStar performs simultaneous dynamic and electrophoretic light scattering (DLS\/ELS) to determine size, polydispersity and zeta potential. \u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDLS\/SLS\u003c\/b\u003e: Simultaneous dynamic and static light scattering (DLS\/SLS) enables size, polydispersity, particle concentration, molar mass and\/or turbidity measurements in as little as 2 µL. \u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAutomation\u003c\/b\u003e: The ZetaStar can be paired with an HPLC autosampler and pump to automate measurements of zeta potential and size for up to -96 samples at a time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConvenience\u003c\/b\u003e: DLS\/ELS and DLS\/SLS can also be carried out  in disposable cells to eliminate cuvette cleaning operations and potential sample carryover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLow volume\u003c\/b\u003e: DLS\/ELS can be performed with as little as  65 µL of solution, and DLS\/SLS with as little as 2 µL. \u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSpeed\u003c\/b\u003e: DLS\/ELS measurements can take just 15 seconds, and DLS\/SLS measurements even less.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHigh salt\u003c\/b\u003e: ZetaStar can measure zeta potential in solutions representative of physiological conditions or formulation buffers with high sensitivity and no damage to fragile biological samples .\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"column one-second mobile-one\"\u003e\u003cdiv class=\"mcb-column-inner\"\u003e\n\u003cdiv style=\"padding:0px 30px 0px 30px\"\u003e\n\u003cp align=\"center\"\u003e\u003cimg alt=\"ZetaStar\" class=\"scale-with-grid\" src=\"https:\/\/www.wyatt.com\/wp-content\/uploads\/2023\/09\/DynaPro-ZetaStar-Hero-View.jpg\"\u003e\u003c\/p\u003e\n\u003cp align=\"center\"\u003e \u003cimg alt=\"zetastar\" src=\"https:\/\/www.wyatt.com\/wp-content\/uploads\/2023\/09\/ZetaStar-Properties-Panels-1000.jpg\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003chr class=\"no_line\" style=\"margin: 0 auto 0px auto\"\u003e\n\u003cdiv class=\"column one-second mobile-one\"\u003e\u003cdiv class=\"mcb-column-inner\"\u003e\n\u003cp\u003e\u003cb\u003eQuick and easy\u003c\/b\u003e: Coupled with the user-friendly on-board app, DYNAMICS Touch\u003csup\u003e™\u003c\/sup\u003e, quick and robust results are just a few clicks away. \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMaximum power\u003c\/b\u003e: Paired with the full power of PC-based DYNAMICS\u003csup\u003e™\u003c\/sup\u003e, the ZetaStar can determine extended solution properties including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eColloidal stability\u003c\/b\u003e: second virial coefficient (\u003ci\u003eA\u003c\/i\u003e\u003csub\u003e2\u003c\/sub\u003e or \u003ci\u003eB\u003c\/i\u003e\u003csub\u003e22\u003c\/sub\u003e) and  diffusion interaction parameter (\u003ci\u003ek\u003c\/i\u003e\u003csub\u003eD\u003c\/sub\u003e), turbidity or opalescence\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eThermal stability\u003c\/b\u003e: temperature of protein melting or aggregation onset (\u003ci\u003eT\u003c\/i\u003e\u003csub\u003em\u003c\/sub\u003e, \u003ci\u003eT\u003c\/i\u003e\u003csub\u003eonset\u003c\/sub\u003e, \u003ci\u003eT\u003c\/i\u003e\u003csub\u003eagg\u003c\/sub\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAccelerate degradation kinetics\u003c\/b\u003e: the evolution of size and molar mass with time at elevated temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMinimum downtime\u003c\/b\u003e: Constructed of a set of field-replaceable modules with no need for optical alignment, the ZetaStar need never leave your lab for maintenance. A Wyatt technician can make most repairs on-site.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"column one-second mobile-one\"\u003e\u003cdiv class=\"mcb-column-inner\"\u003e\n\u003cdiv style=\"padding:0px 30px 0px 30px\"\u003e\n\u003cp align=\"center\" style=\"padding-top:20px\"\u003e \u003cimg alt=\"zetastar\" src=\"https:\/\/www.wyatt.com\/wp-content\/uploads\/2023\/09\/zetastar-description.jpg\" width=\"100%\"\u003e \u003c\/p\u003e\n\u003cp align=\"left\" style=\"color:#075c97;font-size:14px;\"\u003eZetaStar features an intuitive onboard app, DYNAMICS Touch, which enables anyone to walk up to the instrument, insert a cuvette with sample and be guided through a measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003chr class=\"no_line\" style=\"margin: 0 auto 0px auto\"\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize Range (Radius)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 nm to 1 μm (cuvette); 0.2 nm to 400 nm (flow cell)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/mL lysozyme (DLS 90); 1 mg\/mL lysozyme (DLS backscattering)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 ºC to 120 ºC*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetection Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90º (sidescattering) \u0026amp; 163.5º (backscattering)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMolecular Weight Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 Da to 10 MDa**\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParticle Concentration Max Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e225 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParticle Concentration Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 10 particles\/mL (dependent on particle size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTurbidity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 100 NTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMolecular Weight Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/mL lysozyme\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLS Measurements Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10 ºC to 120 ºC*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSLS Measurements Detection Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90º\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 250 mS\/cm***\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMobility Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e“No practical limit”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMobility Size Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 nm to 50 µm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMobility Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mg\/mL lysozyme\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eELS Measurements Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 ºC to 70 ºC*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eELS Measurements Detection Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10º\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFlow Cell\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePEEK, platinum, quartz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eZeta Disposable Cell\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCyclic olefin copolymer, polypropylene, 316 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDip Cell\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQuartz, platinum, polyurethane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDLS Disposable Cuvette\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCyclic olefin copolymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLaser Power Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable 10% to 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLaser Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e785 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eELS, SLS, and DLS detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdditional Detectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLaser monitor for active compensation; Forward monitor measures\ntransmitted light for turbidance and laser\/cell diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Acquisition Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 3600 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCorrelator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e512 channel, 100 nsec sampling time in a multi-tau layout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAuto Inject contact closure,\n2 analog inputs (16 bits, +\/- 10 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUSB\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 USB ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Panel Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e162.5 mm, 16-bit, high-resolution touch screen displays signal graphs, instrument settings, and diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e57 cm (L) x 36 cm (W) x 20 cm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.wyatt.com\/products\/zetastar-brochure-request.html\" target=\"_blank\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Wyatt Technology","offers":[{"title":"Standard","offer_id":46488398037071,"sku":"WDZ","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Active USB","offer_id":46488398069839,"sku":"WDZ-00","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Disabled USB","offer_id":46488398102607,"sku":"WDZ-01","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/DynaPro-ZetaStar-Hero-View.jpg?v=1787675366"},{"product_id":"wyatt-dynapro-plate-reader-iii","title":"DynaPro Plate Reader III","description":"\u003cspan\u003e\u003cp align=\"center\"\u003e\u003cimg src=\"https:\/\/www.wyatt.com\/wp-content\/uploads\/2025\/08\/PR4-Hero-1000.webp\" width=\"500px\"\u003e\u003c\/p\u003e\u003c\/span\u003e\n\u003cp\u003eHigh-throughput, automated, dynamic and static light scattering\u003c\/p\u003e\n\u003cp\u003eUpgrade to plates\u003c\/p\u003e\n\u003cp\u003eRevolutionize your performance by replacing your conventional, cuvette-based dynamic light scattering unit with the automated DynaPro Plate Reader. The DynaPro excels at high-throughput sizing and screening of pharmaceutical and nanoparticle formulations to enable novel workflows that simply would not be possible with other DLS instruments. Even if you need to run just a handful of samples, it's a great productivity booster. \u003c\/p\u003e\n\u003chr class=\"no_line\" style=\"margin: 0 auto 10px auto\"\u003e\n\u003cp\u003eWalk-up operation with DYNAMICS Touch\u003csup\u003e™\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003eThe DynaPro Plate Reader is the only plate-based DLS instrument with a fully integrated, walk-up measurement experience. DYNAMICS Touch is an intuitive—yet powerful—DLS measurement app for collecting, analyzing, and reporting dynamic and static light scattering data. Via the full-size touch screen display, \u003ca href=\"https:\/\/www.wyatt.com\/products\/software\/dynamics-touch.html\"\u003eDYNAMICS Touch\u003c\/a\u003e guides you through the entire setup and measurement process, expertise not required. It tells you if the data quality is sufficient for confidence in the results and displays them instantly, no matter how many wells you measure. Data files and concise PDF reports can be stored on the instrument or transferred via the network. You can even send the report to your phone!\n\u003c\/p\u003e\u003cp\u003eComprehensive solution\u003c\/p\u003e\n\u003cp\u003eFor biotherapeutic development, the DynaPro Plate Reader is a comprehensive solution for stability evaluation. Measure aggregation, aggregate size distributions, changes in solution molecular weight, and propensity for aggregation: indicators of both thermal stability (T\u003csub\u003eonset\u003c\/sub\u003e, T\u003csub\u003em\u003c\/sub\u003e, T\u003csub\u003eagg\u003c\/sub\u003e) and colloidal stability (A\u003csub\u003e2\u003c\/sub\u003e\/B\u003csub\u003e22\u003c\/sub\u003e, k\u003csub\u003eD\u003c\/sub\u003e) may be quantified with plate-based DLS and SLS. Even viscosity of concentrated protein solutions can be screened across dozens of formulations in a single plate.\u003c\/p\u003e\n\u003cp\u003eFor nanoparticle formulation and process development, including  viral vectors, non-viral vectors and nano-drug delivery vehicles, the DynaPro adds particle concentration \/ physical titer to basic DLS measurements of size and polydispersity. Its automation is particularly valued to screen fractions during process development and then to quantify CQAs in quality control.\u003c\/p\u003e\n\u003chr class=\"no_line\" style=\"margin: 0 auto 10px auto\"\u003e\n\u003cp\u003eCompatible with DYNAMICS\u003csup\u003e™\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003eThe DynaPro Plate Reader is operated by \u003ca href=\"https:\/\/www.wyatt.com\/products\/software\/dynamics.html\"\u003eDYNAMICS\u003c\/a\u003e, our powerful software package for collecting, analyzing, and reporting automated batch dynamic and static light scattering data. \u003c\/p\u003e\n\u003cp\u003eDYNAMICS is offered with a 21 CFR Part 11 compliant Security Pack option, enabling the use of the DynaPro Plate Reader in a GMP environment.\u003c\/p\u003e\n\u003cp\u003eRevolutionize DLS\u003c\/p\u003e\n\u003cp\u003eThe DynaPro Plate Reader offers dynamic light scattering (DLS) and static light scattering (SLS) measurements of the size, molecular weight, concentration and interactions of proteins, nanoparticles and other macromolecules \u003ci\u003ein situ\u003c\/i\u003e in industry-standard microwell plates. No liquid handling occurs after dispensing into the plates, to maximize throughput and minimize sample carryover. This ground-breaking instrument provides rapid optimization of the formulation process for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.wyatt.com\/solutions\/applications\/biotherapeutics-biophysical-characterization-aggregation-quality.html\"\u003eBiotherapeutics\u003c\/a\u003e such as monoclonal antibodies and virus-like particles (VLPs)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.wyatt.com\/solutions\/applications\/nanoparticle-characterization-by-multi-angle-and-dynamic-light-scattering.html\"\u003eNanoparticle\u003c\/a\u003e drug delivery vehicles including liposomes and conjugated gold NPs\u003c\/li\u003e\n\u003cli\u003eViral and non-viral gene vectors like \u003ca href=\"https:\/\/www.wyatt.com\/GeneTherapy.html\"\u003eAAV, adenovirus, lentivirus\u003c\/a\u003e and \u003ca href=\"https:\/\/www.wyatt.com\/solutions\/lipid-nanoparticle-characterization.html\"\u003eLNP\u003c\/a\u003e\n\u003c\/li\u003e \u003c\/ul\u003e\n\u003cbr\u003e\n\u003cp\u003eA wealth of applications\u003c\/p\u003e\n\u003cp\u003eThe DynaPro Plate Reader provides unparalleled levels of ease-of-use, productivity, reproducibility, and flexibility in order to address additional demanding applications such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAssessing aggregation or oligomerization\u003c\/li\u003e\n\u003cli\u003eQuantifying AAV titer for multiple processes\u003c\/li\u003e\n\u003cli\u003eDetermining protein stability-indicating parameters such as thermal denaturation and colloidal stability\u003c\/li\u003e\n\u003cli\u003eOptimizing protein crystallization\u003c\/li\u003e\n\u003cli\u003eScreening high-concentration protein solutions for reversible association and viscosity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/wyattfiles.s3-us-west-2.amazonaws.com\/literature\/app-notes\/dls-plate\/WP5003-Automated-dynamic-and-static-light-scattering-in-microwell-plates.pdf\" target=\"_blank\"\u003eRead White Paper\u003c\/a\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eKey features\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure hydrodynamic radius from 0.5 nm to 1000 nm\u003c\/li\u003e\n\u003cli\u003eDetermine particle concentration for particles up to 320 nm in diameter\u003c\/li\u003e\n\u003cli\u003eSensitivity for size down to 0.125 mg\/mL lysozyme\u003c\/li\u003e\n\u003cli\u003eMeasure weight-average molar mass from 1 to 1000 kDa\u003c\/li\u003e\n\u003cli\u003eIndustry-standard microwell plates of 96, 384 or 1536 wells\u003c\/li\u003e\n\u003cli\u003eSample volume from 4 μL to 150 μL\u003c\/li\u003e\n\u003cli\u003eAll measurements made \u003ci\u003ein situ\u003c\/i\u003e in the wells\u003c\/li\u003e\n\u003cli\u003eTemperature ramps from 4 °C to 85 °C\u003c\/li\u003e\n\u003cli\u003eIntegrates with plate-based liquid handling robotics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Well Plate Formats\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96, 384 or 1536 *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize Range (Radius, R h )\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 to 1000 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Concentration @ 14 kDa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.125 mg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMolar Mass Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 Da to 1 MDa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Concentration @ 67 kDa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLaser Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e830 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLaser Power Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable 10% – 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Sample Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Acquisition Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 3600 seconds per well per read\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRead Time per Well\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 – 20 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCorrelator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e512 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOnboard Camera\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 megapixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet (TCP\/IP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 cm (L) x 36 cm (W) x 25 cm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.wyatt.com\/products\/plate-reader-brochure-request.html\" target=\"_blank\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Wyatt Technology","offers":[{"title":"Standard","offer_id":46488398200911,"sku":"WPR3","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Cat. WPR3-01","offer_id":46488398233679,"sku":"WPR3-01","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/PR4-Hero-1000.webp?v=1787675370"},{"product_id":"wyatt-dynapro-plate-reader-4","title":"DynaPro Plate Reader 4","description":"\u003cspan\u003e\u003cp align=\"center\"\u003e\u003cimg src=\"https:\/\/www.wyatt.com\/wp-content\/uploads\/2025\/08\/PR4-Hero-1000.webp\" width=\"500px\"\u003e\u003c\/p\u003e\u003c\/span\u003e\n\u003cp\u003eHigh-throughput, automated, dynamic and static light scattering\u003c\/p\u003e\n\u003cp\u003eUpgrade to plates\u003c\/p\u003e\n\u003cp\u003eRevolutionize your performance by replacing your conventional, cuvette-based dynamic light scattering unit with the automated DynaPro Plate Reader. The DynaPro excels at high-throughput sizing and screening of pharmaceutical and nanoparticle formulations to enable novel workflows that simply would not be possible with other DLS instruments. Even if you need to run just a handful of samples, it's a great productivity booster. \u003c\/p\u003e\n\u003chr class=\"no_line\" style=\"margin: 0 auto 10px auto\"\u003e\n\u003cp\u003eWalk-up operation with DYNAMICS Touch\u003csup\u003e™\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003eThe DynaPro Plate Reader is the only plate-based DLS instrument with a fully integrated, walk-up measurement experience. DYNAMICS Touch is an intuitive—yet powerful—DLS measurement app for collecting, analyzing, and reporting dynamic and static light scattering data. Via the full-size touch screen display, \u003ca href=\"https:\/\/www.wyatt.com\/products\/software\/dynamics-touch.html\"\u003eDYNAMICS Touch\u003c\/a\u003e guides you through the entire setup and measurement process, expertise not required. It tells you if the data quality is sufficient for confidence in the results and displays them instantly, no matter how many wells you measure. Data files and concise PDF reports can be stored on the instrument or transferred via the network. You can even send the report to your phone!\n\u003c\/p\u003e\u003cp\u003eComprehensive solution\u003c\/p\u003e\n\u003cp\u003eFor biotherapeutic development, the DynaPro Plate Reader is a comprehensive solution for stability evaluation. Measure aggregation, aggregate size distributions, changes in solution molecular weight, and propensity for aggregation: indicators of both thermal stability (T\u003csub\u003eonset\u003c\/sub\u003e, T\u003csub\u003em\u003c\/sub\u003e, T\u003csub\u003eagg\u003c\/sub\u003e) and colloidal stability (A\u003csub\u003e2\u003c\/sub\u003e\/B\u003csub\u003e22\u003c\/sub\u003e, k\u003csub\u003eD\u003c\/sub\u003e) may be quantified with plate-based DLS and SLS. Even viscosity of concentrated protein solutions can be screened across dozens of formulations in a single plate.\u003c\/p\u003e\n\u003cp\u003eFor nanoparticle formulation and process development, including  viral vectors, non-viral vectors and nano-drug delivery vehicles, the DynaPro adds particle concentration \/ physical titer to basic DLS measurements of size and polydispersity. Its automation is particularly valued to screen fractions during process development and then to quantify CQAs in quality control.\u003c\/p\u003e\n\u003chr class=\"no_line\" style=\"margin: 0 auto 10px auto\"\u003e\n\u003cp\u003eCompatible with DYNAMICS\u003csup\u003e™\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003eThe DynaPro Plate Reader is operated by \u003ca href=\"https:\/\/www.wyatt.com\/products\/software\/dynamics.html\"\u003eDYNAMICS\u003c\/a\u003e, our powerful software package for collecting, analyzing, and reporting automated batch dynamic and static light scattering data. \u003c\/p\u003e\n\u003cp\u003eDYNAMICS is offered with a 21 CFR Part 11 compliant Security Pack option, enabling the use of the DynaPro Plate Reader in a GMP environment.\u003c\/p\u003e\n\u003cp\u003eRevolutionize DLS\u003c\/p\u003e\n\u003cp\u003eThe DynaPro Plate Reader offers dynamic light scattering (DLS) and static light scattering (SLS) measurements of the size, molecular weight, concentration and interactions of proteins, nanoparticles and other macromolecules \u003ci\u003ein situ\u003c\/i\u003e in industry-standard microwell plates. No liquid handling occurs after dispensing into the plates, to maximize throughput and minimize sample carryover. This ground-breaking instrument provides rapid optimization of the formulation process for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.wyatt.com\/solutions\/applications\/biotherapeutics-biophysical-characterization-aggregation-quality.html\"\u003eBiotherapeutics\u003c\/a\u003e such as monoclonal antibodies and virus-like particles (VLPs)\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.wyatt.com\/solutions\/applications\/nanoparticle-characterization-by-multi-angle-and-dynamic-light-scattering.html\"\u003eNanoparticle\u003c\/a\u003e drug delivery vehicles including liposomes and conjugated gold NPs\u003c\/li\u003e\n\u003cli\u003eViral and non-viral gene vectors like \u003ca href=\"https:\/\/www.wyatt.com\/GeneTherapy.html\"\u003eAAV, adenovirus, lentivirus\u003c\/a\u003e and \u003ca href=\"https:\/\/www.wyatt.com\/solutions\/lipid-nanoparticle-characterization.html\"\u003eLNP\u003c\/a\u003e\n\u003c\/li\u003e \u003c\/ul\u003e\n\u003cbr\u003e\n\u003cp\u003eA wealth of applications\u003c\/p\u003e\n\u003cp\u003eThe DynaPro Plate Reader provides unparalleled levels of ease-of-use, productivity, reproducibility, and flexibility in order to address additional demanding applications such as:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAssessing aggregation or oligomerization\u003c\/li\u003e\n\u003cli\u003eQuantifying AAV titer for multiple processes\u003c\/li\u003e\n\u003cli\u003eDetermining protein stability-indicating parameters such as thermal denaturation and colloidal stability\u003c\/li\u003e\n\u003cli\u003eOptimizing protein crystallization\u003c\/li\u003e\n\u003cli\u003eScreening high-concentration protein solutions for reversible association and viscosity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/wyattfiles.s3-us-west-2.amazonaws.com\/literature\/app-notes\/dls-plate\/WP5003-Automated-dynamic-and-static-light-scattering-in-microwell-plates.pdf\" target=\"_blank\"\u003eRead White Paper\u003c\/a\u003e\u003c\/p\u003e\n\u003cbr\u003e\n\u003cp\u003eKey features\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure hydrodynamic radius from 0.5 nm to 1000 nm\u003c\/li\u003e\n\u003cli\u003eDetermine particle concentration for particles up to 320 nm in diameter\u003c\/li\u003e\n\u003cli\u003eSensitivity for size down to 0.125 mg\/mL lysozyme\u003c\/li\u003e\n\u003cli\u003eMeasure weight-average molar mass from 1 to 1000 kDa\u003c\/li\u003e\n\u003cli\u003eIndustry-standard microwell plates of 96, 384 or 1536 wells\u003c\/li\u003e\n\u003cli\u003eSample volume from 4 μL to 150 μL\u003c\/li\u003e\n\u003cli\u003eAll measurements made \u003ci\u003ein situ\u003c\/i\u003e in the wells\u003c\/li\u003e\n\u003cli\u003eTemperature ramps from 4 °C to 85 °C\u003c\/li\u003e\n\u003cli\u003eIntegrates with plate-based liquid handling robotics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Well Plate Formats\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e96, 384 or 1536 *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSize Range (Radius, R h )\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 to 1000 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Concentration @ 14 kDa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.125 mg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMolar Mass Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 Da to 1 MDa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Concentration @ 67 kDa\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLaser Wavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e830 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLaser Power Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable 10% – 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAttenuation Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Sample Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Acquisition Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 to 3600 seconds per well per read\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRead Time per Well\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 – 20 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCorrelator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e512 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOnboard Camera\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 megapixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet (TCP\/IP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60 cm (L) x 36 cm (W) x 25 cm (H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.wyatt.com\/products\/plate-reader-brochure-request.html\" target=\"_blank\"\u003eBrochure\u003c\/a\u003e\u003c\/p\u003e","brand":"Wyatt Technology","offers":[{"title":"Default Title","offer_id":46488398266447,"sku":"WPR4-01","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/PR4-Hero-1000.webp?v=1787675370"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/collections\/NanoStar_Hero_Display.jpg?v=1790860120","url":"https:\/\/www.danyel.co.il\/collections\/dls.oembed","provider":"danyel biotech","version":"1.0","type":"link"}