{"title":"AST Readers \u0026 Instruments","description":"\u003cp\u003eInstruments for antimicrobial susceptibility testing (AST): automated rapid AST systems that report MICs directly from positive blood cultures, and antibiogram readers that incubate and read disk-diffusion plates. The panels, disks and reagents they run are listed under AST Panels, Disks \u0026amp; Reagents.\u003c\/p\u003e","products":[{"product_id":"quantamatrix-drast-rapid-antimicrobial-susceptibility-testing-system-qmdrastr02","title":"dRAST Rapid Antimicrobial Susceptibility Testing System","description":"\u003cp\u003edRAST provides MIC-based phenotypic antimicrobial susceptibility testing direct from positive blood culture in as low as 4 hours; reducing time to results by up to 2 days compared to conventional method. The rapid results allow for earlier optimization of antibiotics in critically-ill patients with bloodstream infections and sepsis.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDedicated to positive blood culture samples\u003c\/li\u003e\n\u003cli\u003eProvides phenotypic MIC in as low as 4 hours\u003c\/li\u003e\n\u003cli\u003eRandom access with up to 12 samples simultaneously (15 panel positions)\u003c\/li\u003e\n\u003cli\u003eExpert system on board with choice of guidelines\u003c\/li\u003e\n\u003cli\u003eEasy start with no McFarland required, no sample prep\u003c\/li\u003e\n\u003cli\u003e2 panels: 1 Gram Neg. + 1 Gram Pos.\u003c\/li\u003e\n\u003cli\u003eEasy to use, fast to operate\u003c\/li\u003e\n\u003cli\u003eNo daily maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003e2 days faster than conventional AST\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eConventional AST from blood can take at least three days or longer to produce results, as bacteria first has to be detected in blood and a pure isolate obtained before AST can proceed. dRAST, on the other hand, utilizes microfluidic technology and microscopic imaging technology that eliminates the need for pure isolate, to enable much faster results that can impact optimize antibiotic prescribing sooner.\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/www.quantamatrix.com\/wp-content\/uploads\/2022\/07\/Capture-de%CC%81cran-2022-07-12-a%CC%80-15.15.17-1024x195.png\" alt=\"dRAST time to result compared with conventional AST\" style=\"max-width:100%;height:auto\" loading=\"lazy\"\u003e\u003c\/p\u003e\u003ch2\u003eWorkflow\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eClinical workflow\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/www.quantamatrix.com\/wp-content\/uploads\/2022\/07\/drast_workflow_img2_en.jpeg\" alt=\"dRAST clinical workflow\" style=\"max-width:100%;height:auto\" loading=\"lazy\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTechnical workflow\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cimg src=\"https:\/\/www.quantamatrix.com\/wp-content\/uploads\/2022\/07\/drast_workflow_img-1024x358.png\" alt=\"dRAST technical workflow\" style=\"max-width:100%;height:auto\" loading=\"lazy\"\u003e\u003c\/p\u003e\u003ch2\u003eSoftware\u003c\/h2\u003e\u003cp\u003eUser-friendly interface\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSimple\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTouchscreen user interface (UI)\u003c\/li\u003e\n\u003cli\u003eIntuitive result reporting\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLis\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eBi-directional LIS connectivity\u003c\/li\u003e\n\u003cli\u003eCompatible with all major LIS\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFlexible\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRandom access and fully automated to improve workflow\u003c\/li\u003e\n\u003cli\u003eCustom expert rules to accommodate individual lab guidelines\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eExpert System\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIntegration with international and local guidelines (EUCAST, CLSI, and CA-SFM)\u003c\/li\u003e\n\u003cli\u003eReal-time display of raw data and interpreted results\u003c\/li\u003e\n\u003cli\u003eDisplay of MICs and SIR determination in a single screen\u003c\/li\u003e\n\u003cli\u003eActivated comments and rules for each sample, allowing the clinicians and infectious disease specialists to get all the relevant information\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eAntibiotic panels\u003c\/h2\u003e\u003cp\u003eGram-positive and Gram-negative panels using either CLSI or EUCAST recommended antimicrobials and breakpoints are available for dRAST.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCLSI panel: 17 Gram-positive , 19 Gram-negative antibiotics with multiple concentrations\u003c\/li\u003e\n\u003cli\u003eEUCAST panel: 18 Gram-positive , 17 Gram-negative antibiotics with multiple concentrations\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eClinical evidence\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003edRAST provides susceptibility test results with greater reliability at enhanced speed.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eAnalysis of susceptibility results generated by conventional testing methods took an average of 64.5 hours while results from dRAST direct from positive blood cultures only took 14.3 hours.\u003c\/p\u003e\u003cp\u003eSusceptibility result from dRAST is not only rapid but also reliable. Compared to Broth Micro-Dilution (BMD), the overall agreement for dRAST was 94.2% (49\/52) and 98.5% (66\/67) for patients with gram-positive and gram-negative bacteremia, respectively.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eKim et al., Journal of Medical Microbiology 2018; 67: 325-331\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRapid AST is critical for timely prescribing of optimal, targeted antimicrobials.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA prospective study demonstrated the superior impact of dRAST on the selection of optimal antimicrobial therapy for resistant strains compared to Gram staining or MALDI-TOF MS identification.\u003c\/p\u003e\u003cp\u003eThe proportion of optimal targeted treatment was similar between the Gram-staining and the MALDI-TOF MS groups. However, there was significant improvement for the dRAST group compared to the MALDI-TOF MS group. The dRAST group demonstrated a 32% higher rate of optimal, targeted antimicrobial therapy compared to MALDI-TOF and the rate of ineffective therapy was 26% lower.\u003c\/p\u003e\u003cp\u003eThe study demonstrated that result of rapid AST using dRAST contributes significantly more than that of bacterial ID to the administration of optimal targeted antimicrobial treatment.\u003c\/p\u003e\u003cp\u003e\u003cem\u003eKim et al., Journal of Antimicrobial Chemotherapy, Volume 74, Issue 8, August 2019, Pages 2255–2260\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRapid AST by dRAST enables successful implementation of antimicrobial stewardship even in the treatment of bacteremia in the immunosuppressed patients.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eRapid AST by dRAST enables successful implementation of antimicrobial stewardship even for immunosuppressed patients with bacteremia as well as those with underlying hematological disorders.\u003c\/p\u003e\u003cp\u003eDeploying dRAST into the diagnostic process allows more timely management of optimal, targeted treatment. In a recent study, time to initiation of optimal, targeted antimicrobials decreased by 14 hours in the dRAST group (39.0 hrs) compared to the conventional AST group (53.2 hrs).\u003c\/p\u003e\u003cp\u003eIn addition, the proportion of patients receiving optimal, targeted treatment at 48 hours from the first blood draw higher was higher in the dRAST group (66.1%) compared to the conventional AST group (48.3%). Also, the proportion of patients receiving broad-spectrum treatment at 48 hours was lower in the dRAST group (21.4%) compared to the conventional AST group (31.7%).\u003c\/p\u003e\u003cp\u003e\u003cem\u003eKim et al., Clin Microbiol Infect. Volume 27, Issue 1, 2021,Pages 69-75\u003c\/em\u003e\u003c\/p\u003e","brand":"QuantaMatrix","offers":[{"title":"Default Title","offer_id":67669176975439,"sku":"QMdRASTR02","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/drast_check_box_img_205fcba2-d23f-4dc5-ac71-c95bc4888175.jpg?v=1791735519"},{"product_id":"i2a-sirscan-discs-antibiotic-disc-dispensers-round-90-mm-square-120-mm-800226","title":"SIRscan Discs Antibiotic Disc Dispensers, Round 90 mm (6 Cartridges) \/ Square 120 mm (16 Cartridges)","description":"\u003cp\u003e\u003cstrong\u003eSIRscan Discs dispensers\u003c\/strong\u003e - SIRscan discs manual dispensers are designed to allow laboratory professionals to deposit antibiotic discs onto agar media in order to perform antibiograms in accordance with standardized methods. Only i2a SIRscan discs must be used with the dispenser. The cartridges can be used with i2a dispensers available in a 6-disc dispenser for 90 mm diameter round Petri dishes and a 16-disc dispenser for 120 x 120 mm square Petri dishes (SIRscan Discs IFU).\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSimplifies the positioning of the discs on the agar.\u003c\/li\u003e\n\u003cli\u003eHelps maintain consistent spacing between discs.\u003c\/li\u003e\n\u003cli\u003eApplies several discs in a single operation and limits the handling errors of individual discs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eCapacity\u003c\/th\u003e\n\u003cth\u003eFor culture dishes\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e800226\u003c\/td\u003e\n\u003ctd\u003eRound antibiotic disc dispenser\u003c\/td\u003e\n\u003ctd\u003eup to 6 antibiotic cartridges\u003c\/td\u003e\n\u003ctd\u003e90 mm round culture dishes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e800256\u003c\/td\u003e\n\u003ctd\u003eSquare antibiotic disc dispenser\u003c\/td\u003e\n\u003ctd\u003eup to 16 antibiotic cartridges\u003c\/td\u003e\n\u003ctd\u003e120 mm square culture dishes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupplied with\u003c\/td\u003e\n\u003ctd\u003eDispenser (round or square); Storage box with lid; Screwdriver; Desiccant; 6 or 12 piston height shims (depending on the model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare parts\u003c\/td\u003e\n\u003ctd\u003eRound dispenser box (ref. 300363); Square dispenser box (ref. 300376); Desiccant (ref. 310353)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eAfter use, store the dispenser with its desiccant in the storage box; change the desiccant at least once a week (ref. 310353). If stored in the fridge, keep 25 minutes at room temperature before use.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUse with\u003c\/td\u003e\n\u003ctd\u003ei2a SIRscan Discs cartridges only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLot traceability\u003c\/td\u003e\n\u003ctd\u003eDispenser management and antibiotic lot tracking in SIRxpert (manuals MU-1155 \/ MU-1897)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003ei2a (Montpellier, France)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulatory status\u003c\/td\u003e\n\u003ctd\u003eCE-marked in vitro diagnostic medical device (IVDR declaration CE-710704)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eStorage and handling\u003c\/h2\u003e\u003cp\u003eAfter use, store the dispenser with its desiccant in the storage box; change the desiccant at least once a week (ref. 310353). If stored in the fridge, keep 25 minutes at room temperature before use. Clean all parts with 70° denatured alcohol before first use; avoid shocks and vibrations.\u003c\/p\u003e\u003ch2\u003eOrdering\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003ePrice-list description\u003c\/th\u003e\n\u003cth\u003ePlate format\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e800226\u003c\/td\u003e\n\u003ctd\u003eAntibiotic discs dispenser for round plates 90 mm - 6 cartr\u003c\/td\u003e\n\u003ctd\u003eRound, 90 mm plates (6 cartridges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e800256\u003c\/td\u003e\n\u003ctd\u003eAntibiotic discs dispenser for Square Plates 120 mm - 16 ca\u003c\/td\u003e\n\u003ctd\u003eSquare, 120 mm plates (16 cartridges)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/i2a-diagnostics.fr\/wp-content\/plugins\/kg-myi2a\/myi2a-files\/EN\/MU-0210_EN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSIRscan Discs dispenser user manual (MU-0210, PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/i2a-diagnostics.fr\/wp-content\/plugins\/kg-myi2a\/myi2a-files\/EN\/CE-710704_EN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEU declaration of conformity IVDR, SIRscan Discs dispensers (CE-710704, PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/i2a-diagnostics.fr\/en\/produit\/sirscan-discs-2\/\" target=\"_blank\" rel=\"noopener\"\u003eSIRscan Discs product page (i2a-diagnostics.fr)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"i2a","offers":[{"title":"Round, 90 mm plates (6 cartridges)","offer_id":67669536931919,"sku":"800226","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Square, 120 mm plates (16 cartridges)","offer_id":67669536964687,"sku":"800256","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/i2a-sirscan-discs-dispensers.jpg?v=1791729234"},{"product_id":"i2a-sirscan-orion-automated-antibiogram-incubator-reader-kirby-bauer-p30d-s-orion","title":"SIRscan Orion Automated Antibiogram Incubator-Reader for Agar Disc Diffusion (Kirby-Bauer)","description":"\u003cp\u003e\u003cstrong\u003eSIRscan Orion\u003c\/strong\u003e - The only automated system capable of performing the incubation and reading of agar-based antibiograms (Kirby Bauer Method) automatically.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReading Parameters\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReading of all germs in all types of media*.\u003c\/li\u003e\n\u003cli\u003eHigh-resolution colour camera.\u003c\/li\u003e\n\u003cli\u003eDetection of double zones and weak growths.\u003c\/li\u003e\n\u003cli\u003eAutomatic backup of all images.\u003c\/li\u003e\n\u003cli\u003eDisplayed image remains unaltered.\u003c\/li\u003e\n\u003cli\u003ePerforms 100% of the laboratory's antibiograms* (Kirby Bauer Method).\u003c\/li\u003e\n\u003cli\u003eContinuous reading.\u003c\/li\u003e\n\u003cli\u003eRate = 60 boxes\/h.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eExpertise and Validation\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAutomatic or deferred reading of results.\u003c\/li\u003e\n\u003cli\u003eAutomatic sending of results validated by the expert reader.\u003c\/li\u003e\n\u003cli\u003ePossible validation from a remote workstation: visual control.\u003c\/li\u003e\n\u003cli\u003eWorkflow management: dashboard.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLoading\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRemovable racks.\u003c\/li\u003e\n\u003cli\u003e4 racks of 11 plates each.\u003c\/li\u003e\n\u003cli\u003eContinuous loading option.\u003c\/li\u003e\n\u003cli\u003eIntegrated control screen.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eIncubation\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAutomatic incubation.\u003c\/li\u003e\n\u003cli\u003eElectronically regulated temperature.\u003c\/li\u003e\n\u003cli\u003eResult times:\u003c\/li\u003e\n\u003cli\u003eMHR SIR: 6 to 8 hours.\u003c\/li\u003e\n\u003cli\u003eMH\/ISO: 14 to 18 hours.\u003c\/li\u003e\n\u003cli\u003eTemperature management and monitoring.\u003c\/li\u003e\n\u003cli\u003e4 independent compartments.\u003c\/li\u003e\n\u003cli\u003eSeparate and ventilated boxes.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSafe and Secure\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eControlled access.\u003c\/li\u003e\n\u003cli\u003eArchives with remote access.\u003c\/li\u003e\n\u003cli\u003eDetection of symbols and automatic management of i2a disc batch numbers.\u003c\/li\u003e\n\u003cli\u003eUniversal expert system for the validation of ID\/ATG results.\u003c\/li\u003e\n\u003cli\u003eAdvanced traceability.\u003c\/li\u003e\n\u003cli\u003eImages archiving.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e* Refer to the current recommendations.\u003c\/p\u003e\u003ch2\u003eSoftware\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSIRxpert\u003c\/strong\u003e - microbiology middleware: universal open system for the interpretative reading of antibiograms.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eA comprehensive and user-friendly interface.\u003c\/li\u003e\n\u003cli\u003eManagement of raw AST results.\u003c\/li\u003e\n\u003cli\u003eAutomated expertise and interpretation of AST.\u003c\/li\u003e\n\u003cli\u003eValidation control (result consistency).\u003c\/li\u003e\n\u003cli\u003eAutomatic export and import to the LIS or other systems (SIRxpert interface option).\u003c\/li\u003e\n\u003cli\u003eFully configurable and customizable.\u003c\/li\u003e\n\u003cli\u003eOptional epidemiology module.\u003c\/li\u003e\n\u003cli\u003eMonitoring of international standards (CLSI, EUCAST, CASFM).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlates read\u003c\/td\u003e\n\u003ctd\u003eRound 90 mm, Round 140 mm (150 mm with lid), Square 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem components\u003c\/td\u003e\n\u003ctd\u003eSIRscan Orion reader\/incubator with a 4-rack incubator; 24\" touchscreen; PC; Webcam for assistance; SIRxpert Antibiogram software; SIRxpert Antibiotic Susceptibility Testing Flow software; SIRxpert Bidirectional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003eBarcode printer; Barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptions\u003c\/td\u003e\n\u003ctd\u003eSupport table; Articulated arm for screen, mouse, keyboard and barcode reader; SIRxpert Abbreviations (when using i2a discs); SIRxpert batch traceability (when using i2a discs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncubator\u003c\/td\u003e\n\u003ctd\u003e4 racks of 11 plates each, 4 independent temperature-regulated compartments, continuous loading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThroughput\u003c\/td\u003e\n\u003ctd\u003e60 plates per hour\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime to result\u003c\/td\u003e\n\u003ctd\u003eMHR-SIR: 6 to 8 hours; MH \/ ISO: 14 to 18 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e1063 W x 1124 H x 763 D mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e196.4 kg (empty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC, 50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003e350 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e1364 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise level\u003c\/td\u003e\n\u003ctd\u003e55 dB max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation category \/ pollution degree\u003c\/td\u003e\n\u003ctd\u003eII \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003ei2a (Montpellier, France)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulatory status\u003c\/td\u003e\n\u003ctd\u003eCE-marked in vitro diagnostic medical device (IVDR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eOrdering\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003ePrice-list description\u003c\/th\u003e\n\u003cth\u003ePackage\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eP30D-S-ORION\u003c\/td\u003e\n\u003ctd\u003eSIRscan ORION Package\u003c\/td\u003e\n\u003ctd\u003eStandard package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP30D-N-ORION\u003c\/td\u003e\n\u003ctd\u003eSIRscan ORION Nude Package\u003c\/td\u003e\n\u003ctd\u003eNude package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/i2a-diagnostics.fr\/wp-content\/uploads\/2026\/06\/SIRscan_ORION_EN_HD-MKT-BSIRO1EN-B.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSIRscan Orion brochure (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/i2a-diagnostics.fr\/wp-content\/plugins\/kg-myi2a\/myi2a-files\/EN\/MU-1894_EN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSIRscan Orion user manual (MU-1894, PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/i2a-diagnostics.fr\/wp-content\/plugins\/kg-myi2a\/myi2a-files\/EN\/CE-2440_EN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEU declaration of conformity IVDR, SIRscan Orion (CE-2440, PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=IpDMzXEigZM\" target=\"_blank\" rel=\"noopener\"\u003eSIRscan Orion video (YouTube)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/i2a-diagnostics.fr\/en\/produit\/sirscan-orion-en\/\" target=\"_blank\" rel=\"noopener\"\u003eSIRscan Orion product page (i2a-diagnostics.fr)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"i2a","offers":[{"title":"Standard package","offer_id":67669537062991,"sku":"P30D-S-ORION","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Nude package","offer_id":67669537095759,"sku":"P30D-N-ORION","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/i2a-sirscan-orion-render.png?v=1791729234"},{"product_id":"i2a-sirscan-lynx-semi-automatic-antibiogram-reader-kirby-bauer-p40d-s-lynx","title":"SIRscan Lynx Semi-Automatic Antibiogram Reader for Agar Disc Diffusion (Kirby-Bauer)","description":"\u003cp\u003e\u003cstrong\u003eSIRscan Lynx\u003c\/strong\u003e - Semi-automatic reader of antibiograms in agar media (Kirby Bauer Method)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReading Parameters\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReading of all germs on all types of media*\u003c\/li\u003e\n\u003cli\u003eHigh-definition colour camera\u003c\/li\u003e\n\u003cli\u003eDetection of double zones and fine growth\u003c\/li\u003e\n\u003cli\u003eDisplayed image not modified\u003c\/li\u003e\n\u003cli\u003eAutomatic backup of all images\u003c\/li\u003e\n\u003cli\u003ePerforms 100% of the laboratory's antibiograms*\u003c\/li\u003e\n\u003cli\u003eContinuous reading\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eExpertise and Validation\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAutomatic reading and possible deferred expertise\u003c\/li\u003e\n\u003cli\u003eAutomatic sending of results validated by the expert\u003c\/li\u003e\n\u003cli\u003eValidation possible on a remote workstation: visual control\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEquipment and Technology\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eHD colour camera\u003c\/li\u003e\n\u003cli\u003eNUC Micro-PC\u003c\/li\u003e\n\u003cli\u003e24\" HD screen\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSafe\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eControlled access\u003c\/li\u003e\n\u003cli\u003eUser action traceability\u003c\/li\u003e\n\u003cli\u003eArchives with remote access\u003c\/li\u003e\n\u003cli\u003eUniversal expert system for ID\/AST result validation\u003c\/li\u003e\n\u003cli\u003eDetection of symbols and automatic management of i2a disk batch numbers\u003c\/li\u003e\n\u003cli\u003eArchived images\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e* Refer to the current recommendations.\u003c\/p\u003e\u003ch2\u003eSoftware\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eSIRxpert\u003c\/strong\u003e - microbiology middleware: universal open system for the interpretative reading of antibiograms.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eA comprehensive and user-friendly interface\u003c\/li\u003e\n\u003cli\u003eManagement of raw AST results\u003c\/li\u003e\n\u003cli\u003eAutomated expertise and interpretation of AST\u003c\/li\u003e\n\u003cli\u003eValidation control (results consistency)\u003c\/li\u003e\n\u003cli\u003eAutomatic export and import to LIS or other devices (SIRxpert interface option)\u003c\/li\u003e\n\u003cli\u003eFully configurable and customizable\u003c\/li\u003e\n\u003cli\u003eOptional epidemiology module\u003c\/li\u003e\n\u003cli\u003eMonitoring of international standards (CLSI, EUCAST, CASFM)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlates read\u003c\/td\u003e\n\u003ctd\u003ePlate 55 mm, Round 90 mm, Round 140 mm, Square 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem components\u003c\/td\u003e\n\u003ctd\u003eSIRscan Lynx reader with a drawer; 24\" screen; PC; SIRxpert Antibiogram module; SIRxpert Bidirectional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003eBarcode printer; Barcode scanner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptions\u003c\/td\u003e\n\u003ctd\u003eSIRxpert Abbreviations (when using i2a discs); SIRxpert batch traceability (when using i2a discs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReader\u003c\/td\u003e\n\u003ctd\u003eDrawer-loaded semi-automatic reader with HD colour camera and LED lighting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e19 to 26 °C, indoor use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e210 W x 420 H x 540 D mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMains voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC, 50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003e30 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat dissipation\u003c\/td\u003e\n\u003ctd\u003e341 Btu\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation category \/ pollution degree\u003c\/td\u003e\n\u003ctd\u003eII \/ 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003ei2a (Montpellier, France)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulatory status\u003c\/td\u003e\n\u003ctd\u003eCE-marked in vitro diagnostic medical device (IVDR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch2\u003eOrdering\u003c\/h2\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003ePrice-list description\u003c\/th\u003e\n\u003cth\u003ePackage\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eP40D-S-LYNX\u003c\/td\u003e\n\u003ctd\u003eSIRscan LYNX - AST Reader\u003c\/td\u003e\n\u003ctd\u003eStandard package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eP40D-N-LYNX\u003c\/td\u003e\n\u003ctd\u003eSIRscan LYNX Nude Package including:\u003c\/td\u003e\n\u003ctd\u003eNude package\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2\u003eDocuments\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/i2a-diagnostics.fr\/wp-content\/plugins\/kg-myi2a\/myi2a-files\/EN\/MU-2049_EN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSIRscan Lynx user manual (MU-2049, PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/i2a-diagnostics.fr\/wp-content\/plugins\/kg-myi2a\/myi2a-files\/EN\/CE-2441_EN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEU declaration of conformity IVDR, SIRscan Lynx (CE-2441, PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.youtube.com\/watch?v=A5IQOZw4Zds\" target=\"_blank\" rel=\"noopener\"\u003eSIRscan Lynx video (YouTube)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/i2a-diagnostics.fr\/en\/produit\/sirscan-lynx-en\/\" target=\"_blank\" rel=\"noopener\"\u003eSIRscan Lynx product page (i2a-diagnostics.fr)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"i2a","offers":[{"title":"Standard package","offer_id":67669537128527,"sku":"P40D-S-LYNX","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Nude package","offer_id":67669537161295,"sku":"P40D-N-LYNX","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/SIRscan_Lynx-scaled.png?v=1791730457"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/collections\/drast_check_box_img.jpg?v=1791723624","url":"https:\/\/www.danyel.co.il\/collections\/ast-systems-readers.oembed","provider":"danyel biotech","version":"1.0","type":"link"}