{"title":"Analytical Instruments","description":null,"products":[{"product_id":"sensor-chip-cm5-29149604","title":"Sensor Chip CM5","description":"\u003cp\u003eBiacore Sensor Chip CM5 supports a range of immobilization chemistries to capture nucleic acids, peptides, antibodies, proteins, carbohydrates, or chemical compounds for interaction analysis from research to discovery, development \u0026amp; quality control.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFirst choice for immobilization via -NH2, -SH, -CHO, -OH, or -COOH groups.\u003c\/li\u003e\n\u003cli\u003eAttach proteins, antibodies, nucleic acids, carbohydrates, and small molecules (\u0026lt;1000 Da).\u003c\/li\u003e\n\u003cli\u003eCompatible with a wide range of applications from basic research to quality control.\u003c\/li\u003e\n\u003cli\u003eSuitable for ligand fishing and fragment-based drug discovery (FBDD).\u003c\/li\u003e\n\u003cli\u003eHigh immobilization capacity permits a broad range of capture densities.\u003c\/li\u003e\n\u003cli\u003eObtain real-time data on binding specificity, affinity, kinetics, concentration and more.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBiacore Sensor Chip CM5 Matrix\u003c\/p\u003e\n\n\u003cp\u003eThe CM5 sensor chip carries a matrix of carboxymethylated dextran covalently attached to a gold surface. Molecules can be covalently coupled to the sensor surface by exploiting available amine, thiol, aldehyde, or carboxyl functional groups on the ligand. The CM5 dextran matrix extends about 100 nm from the gold surface, and is flexible, allowing relatively free movement of attached ligands.\u003c\/p\u003e\n\n\u003cp\u003eAn exceptionally versatile chip for SPR interaction analysis\u003c\/p\u003e\n\n\u003cp\u003eSensor Chip CM5 is the most versatile and widely used dextran-based chip, suitable for most general-purpose surface plasmon resonance (SPR) applications. Carboxymethyl surface chemistry supports the study of many different types of ligands and binding partners–from small organic molecules, such as drug candidates, through to large molecular assemblies and even whole viruses. High binding capacity gives a high response, advantageous for capture assays and for interactions involving small molecules. High surface stability provides accuracy and precision, and allows repeated analysis on the same surface.\u003c\/p\u003e\n\n\u003cp\u003eApplication examples include:\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/dmm3bwsv3\/AssetStream.aspx?mediaformatid=10061\u0026amp;destinationid=10016\u0026amp;assetid=29958\"\u003eFBDD-based screening for novel drugs against Hepatitis C virus (HCV)\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/dmm3bwsv3\/AssetStream.aspx?mediaformatid=10061\u0026amp;destinationid=10016\u0026amp;assetid=27017\"\u003eSurface plasmon resonance-based determination of adenovirus concentration on Biacore T200\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003eSensor chip formats for Biacore systems\u003c\/p\u003e\n\n\u003cp\u003eBiacore sensor chips are available in two formats:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eS series sensor chips are for use with Biacore 1 series, Biacore 8 series, Biacore T200, Biacore S200 and Biacore 4000 SPR systems.\u003c\/li\u003e\n\t\u003cli\u003eSensor chips not designated with S series are designed for Biacore X100, and Biacore C SPR systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22064823.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ 1 sensor chip \/ Series S","offer_id":45982219698255,"sku":"29104988","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ 3 sensor chips \/ Series S","offer_id":45982219731023,"sku":"BR100530","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ 10 sensor chips \/ Series S","offer_id":45982219763791,"sku":"29149603","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore X100, Biacore C \/ 1 sensor chip \/ Classic","offer_id":45982219796559,"sku":"BR100399","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore X100, Biacore C \/ 3 sensor chips \/ Classic","offer_id":45982219829327,"sku":"BR100012","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore X100, Biacore C \/ 10 sensor chips \/ Classic","offer_id":45982219862095,"sku":"29149604","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-34616-original-png_5f79c42f-7462-4ee4-a296-3e85e873f53c.png?v=1785959156"},{"product_id":"sensor-chip-cm7-29147017","title":"Sensor Chip CM7","description":"\u003cp\u003eBiacore sensor chip with similar properties to Sensor Chip CM5, but for fragment and low molecular weight molecule samples with three times higher capacity.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor fragment and low molecular weight molecule samples.\u003c\/li\u003e\n\u003cli\u003eUse when achieving the required immobilization level is a challenge.\u003c\/li\u003e\n\u003cli\u003eSuitable for small molecule work and fragment-based screening.\u003c\/li\u003e\n\u003cli\u003eHigher binding capacity enables confident measurements of low molecular weight compounds.\u003c\/li\u003e\n\u003cli\u003eHigher signal-to-noise ratios improve screening data quality.\u003c\/li\u003e\n\u003cli\u003eImproves chances of success where immobilization levels are unfavorable, e.g. target protein has low concentration or is very sensitive to immobilization conditions required.\u003c\/li\u003e\n\u003cli\u003eAttach proteins, nucleic acids, carbohydrates, or small molecules.\u003c\/li\u003e\n\u003cli\u003eCouple to carboxyl groups on the sensor surface via -NH2, -SH, -CHO, -OH or -COOH.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSurface matrix\u003c\/p\u003e\n\n\u003cp\u003eCarboxymethylated dextran covalently attached to a gold surface. Molecules are covalently coupled to the sensor surface via amine, thiol, aldehyde, or carboxyl groups. Sensor Chip CM7 is similar to Sensor Chip CM5, but with a higher degree of carboxylation and a denser matrix, providing an approximately three times higher immobilization capacity. The surface is highly useful for more challenging applications, such as studies with small molecules and fragments. It is generally less suitable when working with large biomolecular analytes.\u003c\/p\u003e\n\n\u003cp\u003eSensor chip formats for Biacore systems\u003c\/p\u003e\n\n\u003cp\u003eBiacore sensor chips are available in two formats.\u003c\/p\u003e\n\n\u003cp\u003eSeries S sensor chips are for use with Biacore 1 series, Biacore 8 series, Biacore S200, Biacore T200, and Biacore 4000 SPR systems.\u003c\/p\u003e\n\n\u003cp\u003eSensor chips not designated with Series S are designed for Biacore X100 and Biacore C SPR systems.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-14465-pdf\"\u003eData file (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/28957862.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"1 sensor chip \/ Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ Series S","offer_id":45982219960399,"sku":"28953828","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"1 sensor chip \/ Biacore X100, Biacore C \/ Classic","offer_id":45982219993167,"sku":"28957332","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"3 sensor chips \/ Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ Series S","offer_id":45982220025935,"sku":"29147020","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"3 sensor chips \/ Biacore X100, Biacore C \/ Classic","offer_id":45982220058703,"sku":"29147017","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/sSmwH-rNNkapw2p8Eug4_w-original-png_80986ad7-2a61-4e0c-afd5-0a34a9e81acb.png?v=1785959161"},{"product_id":"sensor-chip-sa-br100032","title":"Sensor Chip SA","description":"\u003cp\u003eThis high-affinity streptavidin (SA) sensor chip immobilizes biotinylated molecules for surface plasmon resonance (SPR) interaction analysis on Biacore systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVersatile: immobilizes biotinylated peptides, proteins, nucleic acids, or carbohydrates\u003c\/li\u003e\n\u003cli\u003eReady-to-use: streptavidin is pre-immobilized, ready for fast, high-affinity ligand capture\u003c\/li\u003e\n\u003cli\u003eRobust: streptavidin-biotin is one of the strongest non-covalent interactions in nature\u003c\/li\u003e\n\u003cli\u003eNon-covalent: a convenient alternative for ligands refractory to covalent immobilization\u003c\/li\u003e\n\u003cli\u003eStandardized ligand orientation: controlled biotinylation enables oriented capture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eStreptavidin-biotin capture\u003c\/p\u003e\n\n\u003cp\u003eSensor Chip SA provides a surface of streptavidin covalently attached to a carboxymethyldextran matrix. Dissociation of biotinylated ligands from the surface of the chip is generally negligible during the course of a Biacore analysis because the affinity of streptavidin for biotin is extremely high, with an equilibrium dissociation constant of about 10-15 M. High binding capacity, reproducibility, and chemical resistance give excellent performance over a broad range of applications. The surface of \u003ca href=\"https:\/\/www.cytivalifesciences.com\/en\/us\/knowledge-center\/Sensor-chips\"\u003eSensor Chip\u003c\/a\u003e SA is resistant to 1-minute pulses of many agents commonly used in SPR sensor chip washing and regeneration protocols.\u003c\/p\u003e\n\n\u003cp\u003eBiacore Sensor Chip SA applications\u003c\/p\u003e\n\n\u003cp\u003eBiotin has become a popular molecular tag for capture and interaction studies because it is stable and rarely interferes with target activity or structure due to its small size. Biotin can be conveniently conjugated to a wide range of target molecules by chemical or enzymatic means. Applications for Sensor Chip SA are therefore broad. Examples include:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003e\u003ca href=\"\/solutions\/protein-research\/knowledge-center\/surface-plasmon-resonance\/characterizing-protac-ternary-complex-formation-using-biacore-spr-systems\"\u003echaracterizing PROTAC ternary complex formation\u003c\/a\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003ca href=\"https:\/\/www.jstage.jst.go.jp\/article\/analsci\/20\/4\/20_4_611\/_pdf\/-char\/en\" target=\"_blank\"\u003escreening of endocrine-disrupting chemicals\u003c\/a\u003e\u003c\/li\u003e\n\t\u003cli\u003e\u003ca href=\"https:\/\/www.jbc.org\/content\/281\/25\/17446.full.pdf\" target=\"_blank\"\u003eelucidating DNA- and RNA- mediated mechanisms of catechins in cancer prevention\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eSensor chip formats for Biacore systems\u003c\/p\u003e\n\n\u003cp\u003eBiacore sensor chips are available in two formats:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eSeries S sensor chips are for use with Biacore 1 series, Biacore 8 series, Biacore S200, Biacore T200, and Biacore 4000 SPR systems.\u003c\/li\u003e\n\t\u003cli\u003eSensor chips not designated with Series S are designed for Biacore X100 and Biacore C SPR systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22060734.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ 1 sensor chip \/ Series S","offer_id":45982220091471,"sku":"29104992","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ 3 sensor chips \/ Series S","offer_id":45982220124239,"sku":"BR100531","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ 10 sensor chips \/ Series S","offer_id":45982220157007,"sku":"29699621","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore X100, Biacore C \/ 1 sensor chip \/ Classic","offer_id":45982220189775,"sku":"BR100398","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore X100, Biacore C \/ 3 sensor chips \/ Classic","offer_id":45982220222543,"sku":"BR100032","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/oiYBNVMGTUWJOdTmX9pTgg-original-png_de766a0a-c5e4-420e-af05-cdaaaf024846.png?v=1785959162"},{"product_id":"sensor-chip-nta-br100034","title":"Sensor Chip NTA","description":"\u003cp\u003eBiacore Sensor Chip NTA captures histidine-tagged molecules by metal chelation for subsequent surface plasmon resonance (SPR) interaction analysis.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVersatile: captures many types of histidine-tagged molecules\u003c\/li\u003e\n\u003cli\u003eReady-to-use: NTA is pre-immobilized, ready for nickel loading and ligand capture\u003c\/li\u003e\n\u003cli\u003eConvenient: compatible NTA reagent kit provides nickel ion and regeneration solutions\u003c\/li\u003e\n\u003cli\u003eEasily regenerated: EDTA injection efficiently removes metal ions to regenerate the sensor\u003c\/li\u003e\n\u003cli\u003eChelation capture: simpler assay development, potential to standardize target orientation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eStable capture of histidine tagged recombinant proteins\u003c\/p\u003e\n\n\u003cp\u003eHistidine is the most widely used molecular tag today. Sensor Chip NTA can be used to capture many different types of poly-histidine-tagged proteins for subsequent SPR assays. Interaction of immobilized proteins with a wide range of analyte molecules can be studied, from low-molecular weight compounds to large proteins. For experiments where low molecular weight analytes are studied, Sensor Chip NTA is the first choice.\u003c\/p\u003e\n\n\u003cp\u003eHow Biacore Sensor Chip NTA chelation capture works\u003c\/p\u003e\n\n\u003cp\u003eSensor Chip NTA consists of carboxymethylated dextran with covalently immobilized nitrilotriacetic acid (NTA). The NTA molecule chelates metal ions such as nickel (Ni\u003csup\u003e2+\u003c\/sup\u003e), creating coordination sites that bind to poly-histidine tags on recombinant proteins and other biomolecules.\u003c\/p\u003e\n\n\u003cp\u003eThe advantages of capture versus covalent immobilization techniques\u003c\/p\u003e\n\n\u003cp\u003eNon-covalent capture of ligands, for example by metal ion chelation, has a number of advantages over covalent immobilization. Tagged proteins can be captured directly from crude cell extracts or culture medium, requiring little or no sample preparation. Since fresh ligand is captured for each cycle, the same chip surface can be used for analysis interactions involving different ligands. Regeneration conditions are generic and therefore the need for assay development is minimized. In addition, capture generates a directed structural orientation of the protein on the surface, potentially offering optimal site exposure.\u003c\/p\u003e\n\n\u003cp\u003eSensor Chip NTA for fragment-based drug discovery (FBDD)\u003c\/p\u003e\n\n\u003cp\u003eThe need for technologies to reliably detect and profile interactions involving very small compounds is increasing in areas such as fragment-based drug discovery (FBDD). Improvements in SPR instrument sensitivity have paved the way for application of chelation capture methods in FBDD. When Sensor Chip NTA is used for FBDD, target protein can readily be removed from the surface of the chip using a pulse of EDTA. In this way, the target protein is always fresh and will not decay.\u003c\/p\u003e\n\n\u003cp\u003eResearchers at SGC Karolinska laboratory used \u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/dmm3bwsv3\/AssetStream.aspx?mediaformatid=10061\u0026amp;destinationid=10016\u0026amp;assetid=15839\"\u003eSensor Chip NTA for PARP1 inhibitor screening\u003c\/a\u003e as part of a successful FBDD program in anticancer drug development. In assays performed using Biacore T200, it was possible for the group to differentiate potential inhibitors of target proteins based on their interaction profiles despite binding to highly similar active sites. In addition, the researchers found that Sensor Chip NTA had the advantage of allowing orientation of the immobilized target protein to be controlled and standardized.\u003c\/p\u003e\n\n\u003cp\u003eSensor chip formats for Biacore systems\u003c\/p\u003e\n\n\u003cp\u003eBiacore sensor chips are available in two formats:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eSeries S sensor chips are for use with Biacore 1 series, Biacore 8 series, Biacore T200, Biacore S200, and Biacore 4000 SPR systems.\u003c\/li\u003e\n\t\u003cli\u003eSensor chips not designated with Series S; are designed for Biacore X100 and Biacore C SPR systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22060737.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"1 sensor chip \/ Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ Series S Sensor Chip","offer_id":45982220320847,"sku":"28994951","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"1 sensor chip \/ Biacore X100, Biacore C \/ Classic","offer_id":45982220353615,"sku":"BR100407","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"3 sensor chips \/ Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ Series S Sensor Chip","offer_id":45982220386383,"sku":"BR100532","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"3 sensor chips \/ Biacore X100, Biacore C \/ Classic","offer_id":45982220419151,"sku":"BR100034","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/YQw_Qdk6u0KPXLqvFvw3fg-original-png_b8779d70-b329-4a79-9f69-7a654a4b96a3.png?v=1785959166"},{"product_id":"sensor-chip-protein-a-29127558","title":"Sensor Chip Protein A","description":"\u003cp\u003eBiacore sensor chip for orientation-specific binding of antibodies (predominantly human) through Fc-region.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWith MabSelect SuRe ligand on the surface.\u003c\/li\u003e\n\u003cli\u003eSite-directed capture of antibody: binds predominantly to the heavy chain within the Fc region and ensures antibodies are bound to the surface in a specific orientation.\u003c\/li\u003e\n\u003cli\u003eTime and effort savings: ready-to-use sensor chip eliminates the need to develop immobilization and regeneration conditions.\u003c\/li\u003e\n\u003cli\u003eConfidence in data: highly controlled development processes and manufacturing conditions ensure reproducible results.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSurface description\u003c\/p\u003e\n\n\u003cp\u003eCarboxymethylated dextran matrix with a recombinant Protein A variant covalently attached. The surface ligand is the same as is used for our MabSelect SuRe protein purification products.\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eBinds antibodies from several mammalian species, most notably human antibodies of the subclasses IgG1, IgG2, and IgG4.\u003c\/li\u003e\n\t\u003cli\u003eBinds only to the heavy chain within the Fc region, ensuring a specific orientation of the antibody on the surface.\u003c\/li\u003e\n\t\u003cli\u003eDoes not bind Fab fragments (unlike native Protein A).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e \u003c\/p\u003e\n\n\u003cp\u003eSensor chip formats for Biacore systems\u003c\/p\u003e\n\n\u003cp\u003eBiacore sensor chips are available in two formats.\u003c\/p\u003e\n\n\u003cp\u003eSeries S sensor chips are for use with Biacore 1 series, Biacore 8 series, Biacore S200, Biacore T200, and Biacore 4000 SPR systems.\u003c\/p\u003e\n\n\u003cp\u003eSensor chips not designated with series S are designed for Biacore X100, and Biacore C SPR systems.\u003c\/p\u003e\n\n\u003cp\u003eConvenient antibody analysis in Biacore systems\u003c\/p\u003e\n\n\u003cp\u003eSensor Chip Protein A is a sensor surface pre-immobilized with a recombinant Protein A variant binding antibodies for protein interaction analysis using Biacore systems. It is ready-to-use with high binding capacity offering a wide dynamic range and high convenience, reproducibility, and robustness. Sensor Chip Protein A is an excellent surface choice for antibody quantitation and characterization in biopharmaceutical late stage development and manufacturing QC.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-17548-pdf\"\u003eData file (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29138304.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ 1 sensor chip \/ Series S","offer_id":45982220484687,"sku":"29127555","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ 3 sensor chips \/ Series S","offer_id":45982220517455,"sku":"29127556","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore X100, Biacore C \/ 1 sensor chip \/ Classic","offer_id":45982220550223,"sku":"29127557","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore X100, Biacore C \/ 3 sensor chips \/ Classic","offer_id":45982220582991,"sku":"29127558","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/c1gVlUYI5EKZMsHDuEHoYA-original-png_2aa2eab3-90ef-49c4-9ff7-991680b21ee4.png?v=1785959167"},{"product_id":"sia-kit-au-br100405","title":"SIA kit Au","description":"\u003cp\u003eKit for designing unique surface chemistries. Contains 10 gold sensor surfaces and sensor chip supports, along with assembly kit and accessories.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesign customized surface chemistries using self-assembled monolayers (SAM) or other modifications.\u003c\/li\u003e\n\u003cli\u003eStudy interactions between surface materials and biomolecules.\u003c\/li\u003e\n\u003cli\u003eAllows the use of a wide variety of coating techniques, including those using harsh conditions that the chip carrier would not withstand.\u003c\/li\u003e\n\u003cli\u003eNot recommended for use with Biacore 4000.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEasy assembly\u003c\/p\u003e\n\n\u003cp\u003eContains unmounted gold surfaces and separate sensor chip supports for easy assembly after surface coating. This allows the use of a wide variety of coating techniques, including those using harsh conditions that the chipcarrier would not withstand.\u003c\/p\u003e\n\n\u003cp\u003eKit includes\u003c\/p\u003e\n\n\u003cp\u003e10 sensor surfaces Au, 16 adhesive strips, and for each format 10 sensor chip supports, 1 protective sheath, and 1 assembly unit.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22057521.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"1 sensor chip","offer_id":45982220779599,"sku":"BR100405","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-41061-original-png_d67ef8bd-38b2-4ef9-89a1-7ea5ae86974c.png?v=1785959170"},{"product_id":"sensor-chip-l1-br100543","title":"Sensor Chip L1","description":"\u003cp\u003eBiacore sensor chip offering stable, high-capacity capture of vesicles and liposomes while maintaining the lipid bilayer.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse to incorporate a molecule into a lipid bilayer.\u003c\/li\u003e\n\u003cli\u003eFor rapid and reproducible capture of lipid membrane vesicles.\u003c\/li\u003e\n\u003cli\u003eNo anchoring molecules needed.\u003c\/li\u003e\n\u003cli\u003eBilayer structure maintained.\u003c\/li\u003e\n\u003cli\u003eSuitable for work with transmembrane proteins.\u003c\/li\u003e\n\u003cli\u003ePossible to combine covalent immobilization properties from the CM-family of sensor chips with a lipid anchor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMatrix\u003c\/p\u003e\n\n\u003cp\u003eLipophilic groups are covalently attached to carboxymethylated dextran, making the surface suitable for direct attachment of lipid membrane vesicles such as liposomes. After attachment, the lipid bilayer structure is retained, facilitating the study of interactions involving transmembrane receptors in membrane-like environments.\u003c\/p\u003e\n\n\u003cp\u003eSensor chip formats for Biacore systems\u003c\/p\u003e\n\n\u003cp\u003eBiacore sensor chips are available in two formats.\u003c\/p\u003e\n\n\u003cp\u003eSeries S sensor chips are for use with Biacore 1 series, Biacore 8 series, Biacore S200, Biacore T200, and Biacore 4000 SPR systems.\u003c\/p\u003e\n\n\u003cp\u003eSensor chips not designated with Series S are designed for Biacore X100, Biacore 3000 and Biacore C SPR systems.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22060714.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"1 sensor chip \/ Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ Series S Sensor Chip","offer_id":45982220812367,"sku":"29104993","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"3 sensor chips \/ Biacore X100, Biacore C \/ Classic","offer_id":45982220845135,"sku":"BR100543","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/wFb5MraUtk-TVum8dnBfFA-original-png_8958ea59-ce22-4087-8624-0dfde41a11cc.png?v=1785959173"},{"product_id":"sensor-chip-cm3-br100541","title":"Sensor Chip CM3","description":"\u003cp\u003eBiacore sensor chip with similar properties to Sensor Chip CM5, suited to large interaction partners and exploratory assay conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWith shorter dextran matrix and similar charge density to explore alternative assay conditions.\u003c\/li\u003e\n\u003cli\u003eUse when the interaction partner in solution is very large.\u003c\/li\u003e\n\u003cli\u003eImproves sensitivity when monitoring certain interactions.\u003c\/li\u003e\n\u003cli\u003eMaintains sensitivity by keeping large particles as close as possible to the surface.\u003c\/li\u003e\n\u003cli\u003eAttach proteins, nucleic acids, carbohydrates or small molecules.\u003c\/li\u003e\n\u003cli\u003eCouple to carboxyl groups on the sensor surface via -NH2, -SH, -CHO, -OH or -COOH.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMatrix\u003c\/p\u003e\n\n\u003cp\u003eThe shorter dextran chains of the CM3 allows the interaction to take place closer to the surface which can improve sensitivity when working with large molecules, molecular complexes, viruses or whole cells.\u003c\/p\u003e\n\n\u003cp\u003eSensor chip formats for Biacore systems\u003c\/p\u003e\n\n\u003cp\u003eBiacore sensor chips are available in two formats.\u003c\/p\u003e\n\n\u003cp\u003eSeries S sensor chips are for use with Biacore 1 series, Biacore 8 series, Biacore S200, Biacore T200, and Biacore 4000 SPR systems.\u003c\/p\u003e\n\n\u003cp\u003eSensor chips not designated with Series S are designed for Biacore X100 and Biacore C SPR systems.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22060728.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ 3 sensor chips \/ Series S","offer_id":45982221041743,"sku":"BR100536","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore X100, Biacore C \/ 3 sensor chips \/ Classic","offer_id":45982221074511,"sku":"BR100541","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/BnJqoqKU30Cd-Q6ybzam3g-original-png_1c3c1754-0739-40aa-b838-823fd8060e72.png?v=1785959177"},{"product_id":"sensor-chip-protein-l-29205137","title":"Sensor Chip Protein L","description":"\u003cp\u003eA Biacore Extend sensor chip for site-directed antibody capture. Suitable for study of a wide range of antibody fragments including Fabs and dAbs.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse for oriented capture of antibody fragments\u003c\/li\u003e\n\u003cli\u003eReady-to-use, eliminating the need to develop immobilization and regeneration conditions, saving time and effort.\u003c\/li\u003e\n\u003cli\u003eCaptures a wide range of antibody fragments, such as Fabs, single-chain variable fragments (scFv), kappa light chain subtypes 1, 3 and 4, and domain antibodies (dAbs).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSurface description\u003c\/p\u003e\n\n\u003cp\u003eCarboxymethylated dextran matrix pre-immobilized with a recombinant Protein L for antibodies and antibody fragments containing kappa light chain subtypes (1, 3 and 4) without interfering with its antigen-binding site.\u003c\/p\u003e\n\n\u003cp\u003eSuitable for the capture of a wider range of antibody classes\u003c\/p\u003e\n\n\u003cp\u003eProtein L is suitable for the capture of a wider range of antibody classes than both Protein A and Protein G, including IgG, IgM, IgA, IgE, and IgD.\u003c\/p\u003e\n\n\u003cp\u003eProtein L does not bind bovine immunoglobulins, which often contaminate serum supplements, and is therefore especially useful for quantifying antibodies and antibody fragments from serum based culture.\u003c\/p\u003e\n\n\u003cp\u003eSensor chip formats for Biacore systems\u003c\/p\u003e\n\n\u003cp\u003eBiacore sensor chips are available in two formats.\u003c\/p\u003e\n\n\u003cp\u003eS series sensor chips are for use with Biacore 1 series, Biacore 8 series, Biacore S200, Biacore T200, and Biacore 4000 SPR systems.\u003c\/p\u003e\n\n\u003cp\u003eSensor chips not designated with S series are designed for Biacore X100 and Biacore C SPR systems.\u003c\/p\u003e\n\n\u003cp\u003eResponding to customer needs faster with Biacore Extend\u003c\/p\u003e\n\n\u003cp\u003eSensor Chip Protein L is one of an expanding range of Biacore Extend products. These sensor chips provide researchers working in non-regulated environments with the convenience of a wider choice of consumables optimized for Biacore applications.\u003c\/p\u003e\n\n\u003cp\u003eWhat to expect from Biacore Extend product:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eOrdered as standard products.\u003c\/li\u003e\n\t\u003cli\u003eSame customer support system is used as for a regular product.\u003c\/li\u003e\n\t\u003cli\u003eQC performed, but no Certificate of Analysis\/Conformance issued.\u003c\/li\u003e\n\t\u003cli\u003eFor some products, lot-to-lot variation might be higher compared to a standard product.\n\t\u003cp\u003e \u003c\/p\u003e\n\n\t\u003cul\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29212797.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ 1 sensor chip \/ Series S","offer_id":45982220943439,"sku":"29205138","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore X100, Biacore C \/ 1 sensor chip \/ Classic","offer_id":45982220976207,"sku":"29205137","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-7547-original-png_933dc613-669e-4d61-822c-a0fdd60ca619.png?v=1785959177"},{"product_id":"sensor-chip-protein-g-29179316","title":"Sensor Chip Protein G","description":"\u003cp\u003eA Biacore Extend product used for oriented capture or binding of a wide range of mammalian and all human antibody subclasses.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBinds only to the heavy chain within the Fc region ensuring antibodies are bound to the surface in a specific orientation.\u003c\/li\u003e\n\u003cli\u003eReady to use, eliminating the need to develop immobilization and regeneration conditions, saving time and effort.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSurface description\u003c\/p\u003e\n\n\u003cp\u003eCarboxymethylated dextran matrix pre-immobilized with a recombinant Protein G - GammaBind G, Type 2.\u003c\/p\u003e\n\n\u003cp\u003eThe recombinant Protein G binds a broad range of IgG, such as human (including IgG3), rat, rabbit, mouse, guinea pig, goat, sheep, and cow.\u003c\/p\u003e\n\n\u003cp\u003eConvenience with high reproducibility and robustness\u003c\/p\u003e\n\n\u003cp\u003eSensor Chip Protein G combines convenience with high reproducibility and robustness in the analysis of interactions where antibodies are used as ligands.\u003c\/p\u003e\n\n\u003cp\u003eSensor chip formats for Biacore systems\u003c\/p\u003e\n\n\u003cp\u003eBiacore sensor chips are available in two formats.\u003c\/p\u003e\n\n\u003cp\u003eSeries S sensor chips are for use with Biacore 1 series, Biacore 8 series, Biacore S200, Biacore T200, and Biacore 4000 SPR systems.\u003c\/p\u003e\n\n\u003cp\u003eSensor chips not designated with Series S are designed for Biacore X100 and Biacore C SPR systems.\u003c\/p\u003e\n\n\u003cp\u003eResponding to customer needs faster with Biacore Extend\u003c\/p\u003e\n\n\u003cp\u003eSensor Chip Protein G is one of an expanding range of Biacore Extend products. These sensor chips provide researchers working in non regulated environments with the convenience of a wider choice of consumables optimized for Biacore applications.\u003c\/p\u003e\n\n\u003cp\u003eWhat to expect from Biacore Extend product:\u003cbr\u003e\n- Ordered as standard products.\u003cbr\u003e\n- Same customer support system is used as for a regular product.\u003cbr\u003e\n- QC performed, but no Certificate of Analysis\/Conformance issued.\u003cbr\u003e\n- For some products, lot-to-lot variation might be higher compared to a standard product.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29214397.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ 1 sensor chip \/ Series S","offer_id":45982221402191,"sku":"29179315","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore X100, Biacore C \/ 1 sensor chip \/ Classic","offer_id":45982221434959,"sku":"29179316","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-7061-original-png_815e8046-c129-409b-bf99-8d6eeaf5e857.png?v=1785959181"},{"product_id":"sensor-chip-peg-29245706","title":"Sensor Chip PEG","description":"\u003cp\u003eSensor chip that provides an excellent alternative for analytes that demonstrate unwanted binding to dextran-based surfaces.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReliable interaction data for multivalent and large molecules.\u003c\/li\u003e\n\u003cli\u003eUses standard immobilization (EDC\/NHS) chemistry.\u003c\/li\u003e\n\u003cli\u003eCouple to carboxyl groups on the sensor surface via -NH₂, -SH, -CHO, -OH, -COOH, or C(O)NHC(O) functional groups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSensor chip formats for Biacore systems\u003c\/p\u003e\n\n\u003cp\u003eBiacore sensor chips are available in two formats.\u003c\/p\u003e\n\n\u003cp\u003eSeries S sensor chips are for use with Biacore 1 series, Biacore 8 series, Biacore S200, Biacore T200, and Biacore 4000 SPR systems.\u003c\/p\u003e\n\n\u003cp\u003eSensor chips not designated with Series S are designed for Biacore X100, Biacore 3000 and Biacore C SPR systems.\u003c\/p\u003e\n\n\u003cp\u003eAvoid unwanted binding with PEG surface\u003c\/p\u003e\n\n\u003cp\u003eSensor Chip PEG is a polyethylene glycol (PEG)-based sensor chip that offers an alternative to dextran-based surfaces where unwanted binding of analyte can occur. The flat surface allows interactions closer to the surface, which is beneficial when the interaction partner in solution is multivalent or very large.\u003c\/p\u003e\n\n\u003cp\u003eThe protein-repelling property of PEG chains minimizes unwanted binding while the -COOH groups provide a functional attachment site for immobilization\/capture of molecules of interest.\u003c\/p\u003e\n\n\u003cp\u003eCoupling chemistry for a range of functional groups\u003c\/p\u003e\n\n\u003cp\u003eAmine coupling, utilizing EDC\/NHS chemistry, is the most common ligand immobilization approach. Thiol (-SH), aldehyde (-CHO), and maleimide (C[O]NHC[O]) coupling are also possible with this surface using the appropriate chemistry.\u003c\/p\u003e\n\n\u003cp\u003eResponding to customer needs faster with Biacore Extend\u003c\/p\u003e\n\n\u003cp\u003eSensor Chip PEG is one of an expanding range of Biacore Extend products. These sensor chips provide researchers working in nonregulated environments with the convenience of a wider choice of consumables optimized for Biacore applications.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29272453.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ 1 sensor chip \/ Series S","offer_id":45982221467727,"sku":"29239810","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore X100, Biacore C \/ 1 sensor chip \/ Classic","offer_id":45982221500495,"sku":"29245706","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-29775-original-png_8d5262de-483d-40a8-bcd9-27d4c3c09156.png?v=1785959181"},{"product_id":"sensor-chip-cm4-br100539","title":"Sensor Chip CM4","description":"\u003cp\u003eAn alternative to Sensor Chip CM5 with similar dextran matrix but lower charge for improved sensitivity for certain interactions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWith similar dextran matrix but lower charge.\u003c\/li\u003e\n\u003cli\u003eSuitable for exploring alternative assay conditions (e.g. addressing background binding).\u003c\/li\u003e\n\u003cli\u003eUse when sample contaminants have a high positive charge.\u003c\/li\u003e\n\u003cli\u003eSuitable for negatively charged proteins and nucleic acids.\u003c\/li\u003e\n\u003cli\u003eAttach proteins, nucleic acids, carbohydrates or small molecules.\u003c\/li\u003e\n\u003cli\u003eCouple to carboxyl groups on the sensor surface via -NH2, -SH, -CHO, -OH or -COOH.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMatrix\u003c\/p\u003e\n\n\u003cp\u003eSimilar to Sensor Chip CM5 but with a lower degree of carboxymethylation, which can improve sensitivity for certain interactions. Due to the reduced net negative charge, the surface is well suited for use with negatively charged molecules.\u003c\/p\u003e\n\n\u003cp\u003eSensor chip formats for Biacore systems\u003c\/p\u003e\n\n\u003cp\u003eBiacore sensor chips are available in two formats.\u003c\/p\u003e\n\n\u003cp\u003eSeries S sensor chips are for use with Biacore 1 series, Biacore 8 series, Biacore S200, Biacore T200, and Biacore 4000 SPR systems.\u003c\/p\u003e\n\n\u003cp\u003eSensor chips not designated with Series S are designed for Biacore X100 and Biacore C SPR systems.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22060704.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ 1 sensor chip \/ Series S","offer_id":45982221598799,"sku":"29104989","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ 3 sensor chips \/ Series S","offer_id":45982221631567,"sku":"BR100534","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore X100, Biacore C \/ 3 sensor chips \/ Classic","offer_id":45982221664335,"sku":"BR100539","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/snY6N9nk3USLQcVrq6ZENw-original-png_8da9ce5c-1a9f-45ca-b45b-09e4ea533013.png?v=1785959185"},{"product_id":"sensor-chip-c1-br100540","title":"Sensor Chip C1","description":"\u003cp\u003eBiacore sensor chip with carboxymethylated, matrix-free surface for covalent immobilization. Use when there is a need to avoid dextran on the surface.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse when the interaction partner in solution is multivalent or very large.\u003c\/li\u003e\n\u003cli\u003eMaintains sensitivity by keeping large particles as close as possible to the surface.\u003c\/li\u003e\n\u003cli\u003eReduces avidity effects with multivalent interaction partners.\u003c\/li\u003e\n\u003cli\u003eAttach proteins, nucleic acids, carbohydrates or small molecules.\u003c\/li\u003e\n\u003cli\u003eCouple to carboxyl groups on the sensor surface via -NH2, -SH, -CHO, -OH or -COOH.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\n\u003cp\u003eThe matrix-free surface of Sensor Chip C1 is carboxymethylated and has a low binding capacity. The flat surface allows interactions to take place closer to the surface. These features can be beneficial when working with multivalent interaction partners, large molecules, molecular complexes and particles. This surface is also useful for those few interactions that may be affected by the presence of dextran.\u003c\/p\u003e\n\n\u003cp\u003eSensor chip formats for Biacore systems\u003c\/p\u003e\n\n\u003cp\u003eBiacore sensor chips are available in two formats.\u003c\/p\u003e\n\n\u003cp\u003e“S series” sensor chips are for use with Biacore 8K+, Biacore 8K, Biacore S200, Biacore T200, and Biacore 4000 SPR systems.\u003c\/p\u003e\n\n\u003cp\u003eSensor chips not designated with “S series” are designed for Biacore X100 and Biacore C SPR systems.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22060707.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"1 sensor chip \/ Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ Series S","offer_id":45982221729871,"sku":"29104944","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"3 sensor chips \/ Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ Series S","offer_id":45982221762639,"sku":"BR100535","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"3 sensor chips \/ Biacore X100, Biacore C \/ Classic","offer_id":45982221795407,"sku":"BR100540","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/aa4BYC4mRUKXufMGiVxsMQ-original-png_c24e5d47-505c-41f6-bda1-51a130a3e199.png?v=1785959187"},{"product_id":"sensor-chip-au-br100542","title":"Sensor Chip Au","description":"\u003cp\u003eBiacore sensor chip with an untreated gold surface is used for the design and creation of unique surface chemistries.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor use with Biacore X100, Biacore 3000 and Biacore C SPR systems.\u003c\/li\u003e\n\u003cli\u003eFor most types of interaction analyses in Biacore systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDescription\u003c\/p\u003e\n\u003cp\u003eThe sensor chip is fixed to a polystyrene support sheath. Each cassette, consisting of a sensor chip and sheath assembly, is individually packed under a nitrogen atmosphere in a sealed pouch.\u003c\/p\u003e\n\u003cp\u003eNote\u003c\/p\u003e\n\u003cp\u003eFor \u003ci\u003ein vitro\u003c\/i\u003e use only.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22060721.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"3 sensor chips","offer_id":45982221828175,"sku":"BR100542","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/69c2a45ee6724ce6b5869640310fc044_c0068a0c-cd59-4882-b332-109d471ad662.png?v=1785956229"},{"product_id":"biacore-series-s-sensor-chip-prisma-29650264","title":"Biacore™ Series S Sensor Chip PrismA","description":"\u003cp\u003eUse this Biacore sensor chip with PrismA ligand to consistently optimize processes and to perform quality control of antibody concentration analysis. The sensor chip is pre-functionalized with the same recombinant protein A molecule used to capture antibodies in MabSelect PrismA™ resins. Well suited for biopharmaceutical process development, biomanufacturing, and QC.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSave time and effort with this ready-to-use sensor chip. The prefunctionalized PrismA ligand means you don't have to develop immobilization and regeneration conditions for your antibody concentration assay.\u003c\/li\u003e\n\u003cli\u003eUse one sensor surface to bind a wide variety of antibodies from mammalian species, including human in subclasses IgG1, IgG2, and IgG4. Binding mainly takes place between the constant heavy chain domains, CH2 and CH3, in the Fc region of the antibody.\u003c\/li\u003e\n\u003cli\u003eEnhance binding affinity – compared to Sensor Chip Protein A – for the VH3 sequence located on the variable heavy chain of the Fab region.\u003c\/li\u003e\n\u003cli\u003eEnsure that assays are robust, with reproducible high-affinity capture over more than 200 analysis cycles per channel.\u003c\/li\u003e\n\u003cli\u003eHave confidence in your data. Results are reproducible, because sensor chips are developed and manufactured under highly controlled conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUse \u003ca href=\"\/solutions\/protein-research\/interaction-analysis-with-biacore-surface-plasmon-resonance-spr\/biacore-selection-tool\"\u003ethis tool\u003c\/a\u003e if you want to attach your own ligands for a Biacore™ SPR assay.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-49608-pdf\"\u003eData file (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29698719.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ 1 sensor chip \/ Series S","offer_id":45982278484047,"sku":"29650263","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ 3 sensor chips \/ Series S","offer_id":45982278516815,"sku":"29650264","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-49558-original-png_299f26ff-ad05-46e5-9a7a-3108ef316bf8.png?v=1785959784"},{"product_id":"series-s-sensor-chip-na-29699622","title":"Series S Sensor Chip NA","description":"\u003cp\u003eSeries S Sensor Chip NA is designed for high-affinity capture of biotinylated molecules with subsequent analysis of ligand-analyte binding in primarily low molecular weight applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduced nonspecific binding: Series S Sensor Chip NA is an alternative to test when nonspecific binding effects are experienced with Sensor Chip SA.\u003c\/li\u003e\n\u003cli\u003eNoncovalent: a convenient alternative for ligands sensitive to covalent immobilization.\u003c\/li\u003e\n\u003cli\u003eReady-to-use: pre-immobilized NeutrAvidin™ sensor chip eliminates need for preparation of coupling reagents and optimization of coupling conditions.\u003c\/li\u003e\n\u003cli\u003eVersatile: immobilize biotinylated peptides, proteins, or nucleic acids for oriented capture.\u003c\/li\u003e\n\u003cli\u003eRobust: reproducible high-affinity ligand capture and robust capacity for more than 200 cycles.\u003c\/li\u003e\n\u003cli\u003eFlexible: supports researchers with preference for NeutrAvidin ligand.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeutrAvidin capture of biotinylated molecules\u003c\/p\u003e\n\n\u003cp\u003eSeries S Sensor Chip NA provides a surface of NeutrAvidin covalently attached to a carboxymethylated dextran matrix, which enables immobilization of biotinylated molecules. High binding capacity, reproducibility, and chemical resistance give excellent performance.\u003c\/p\u003e\n\n\u003cp\u003eResponding to customer needs faster with Biacore Extend\u003c\/p\u003e\n\u003cp\u003eSensor Chip NA is one of an expanding range of Biacore Extend products. These sensor chips provide researchers working in nonregulated environments with the convenience of a wider choice of consumables optimized for Biacore applications.\u003c\/p\u003e\n\u003cp\u003eWhat to expect from Biacore Extend product:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOrdered as standard products.\u003c\/li\u003e\n\u003cli\u003eSame customer support system is used as for a regular product.\u003c\/li\u003e\n\u003cli\u003eQC performed, but no Certificate of Analysis\/Conformance issued.\u003c\/li\u003e\n\u003cli\u003eFor some products, lot-to-lot variation might be higher compared to a standard product.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29453996.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"1 sensor chip \/ Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ Series S","offer_id":45982290313295,"sku":"29407997","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"3 sensor chips \/ Biacore 1K, Biacore 1K+,  Biacore 1S+, Biacore 8K,  Biacore 8K+, Biacore T200, Biacore S200,  Biacore 4000 \/ Series S","offer_id":45982290346063,"sku":"29699622","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-46751-original-png_b2f95b7a-c0f4-46f0-b4d9-d2e1b56caa52.png?v=1785959971"},{"product_id":"biacore-cap-tag-capture-kit-29805821","title":"Biacore™ cap-tag capture kit","description":"\u003cp\u003eBiacore™ cap-tag capture kit simplifies kinetic and affinity analysis of protein interactions with minimal assay development. Attach your protein to Series S Sensor Chip CAP using a Biacore™ cap-tag, enabling reversible capture and easy regeneration for up to 150 cycles.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimple protein capture regardless of existing tag\u003c\/li\u003e\n\u003cli\u003eSave time and effort. No need to develop attachment or regeneration conditions.\u003c\/li\u003e\n\u003cli\u003eA reusable and cost-effective solution for protein interaction analysis\u003c\/li\u003e\n\u003cli\u003eEasy-to-follow instructions and predefined Biacore™ Insight software methods for your convenience\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis capture kit enables attachment of your target protein to a Biacore™ sensor chip by first conjugating a short oligonucleotide tag (Biacore™ cap-tag) to your protein. Biacore™ cap-tag binds to the complementary oligo on Series S Sensor Chip CAP.\u003c\/p\u003e\n\n\u003cp\u003eThe resulting Biacore™ cap-tag protein conjugate can be reversibly captured for protein interaction analysis in Biacore™ systems. After each analysis cycle, the surface is regenerated by removing the protein and any bound analyte, which allows fresh protein conjugate to be attached in subsequent cycles.\u003c\/p\u003e\n\n\u003cp\u003eBiacore cap-tag capture kit series s is sold as a combination of three different products containing all reagents required for conjugation and capture of Biacore cap-tag ligand conjugates:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli class=\"-font--body\"\u003eBiacore™ cap-tag conjugation kit that contains Biacore™ conjugation buffer, Biacore™ ligand activator, and Biacore™ cap-tag\u003c\/li\u003e\n\t\u003cli class=\"-font--body\"\u003eAmersham™ MicroSpin™ G-50 columns for buffer exchange and purification\u003c\/li\u003e\n\t\u003cli class=\"-font--body\"\u003eSeries S Sensor Chip CAP\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe capture kit should be used alongside:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli class=\"-font--body\"\u003eBiacore™ regeneration kit CAP, which contains stocks for preparing regeneration solution for Series S Sensor Chip CAP\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003ePlease note:\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli class=\"-font--body\"\u003e\u003cstrong\u003eIf ordering Biacore™ cap-tag capture kit series s you will also need to order Biacore™ regeneration kit CAP separately to regenerate your sensor chip.\u003c\/strong\u003e\u003c\/li\u003e\n\t\u003cli class=\"-font--body\"\u003e\n\u003cstrong\u003eAll products included in Biacore™ cap-tag capture kit can be purchased as standalone items, which provide flexibility for your assay set up. If you already have solutions or sensor chips, you can purchase any additional products needed below.\u003c\/strong\u003e\n\t\u003cul\u003e\n\t\t\u003cli class=\"-font--body\"\u003e\u003cstrong\u003eBiacore™ cap-tag conjugation kit and Biacore™ regeneration kit CAP can only be purchased on this page. You can add to cart in the production specification section below.\u003c\/strong\u003e\u003c\/li\u003e\n\t\t\u003cli class=\"-font--body\"\u003e\u003cstrong\u003e\u003ca href=\"\/shop\/molecular-and-immunodiagnostics\/pcr-cleanup-and-size-selection\/illustra-microspin-g-50-columns-p-00056\"\u003eAmersham™ MicroSpin™ G-50 columns for buffer exchange and purification\u003c\/a\u003e and \u003ca href=\"\/shop\/protein-analysis\/spr-label-free-analysis\/spr-consumables\/spr-sensor-chips\/series-s-sensor-chip-cap-p-55818\"\u003eSeries S Sensor Chip CAP\u003c\/a\u003e can be purchased on their standalone pages.\u003c\/strong\u003e\u003c\/li\u003e\n\t\u003c\/ul\u003e\n\t\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eComprehensive and detailed instructions guide you through the complete workflow from protein to evaluated kinetic data. We provide predefined run and evaluation methods for Biacore™ Insight software for added convenience.\u003c\/p\u003e\n\n\u003cp\u003eBiacore™ cap-tag capture kit series s is developed specifically for protein-protein interaction studies on Biacore™ 8 series, Biacore™ 1 series, Biacore™ T200, and Biacore™ S200 SPR systems, but can be used for other applications.\u003c\/p\u003e\n\n\u003cp\u003eBiacore™ cap-tag conjugation kit and Biacore™ regeneration kit CAP can be used with any Biacore™ system, but Biacore™ X100 and Biacore™ legacy system users will need to combine these with Sensor Chip CAP which is a component of Biotin CAPture kit (28920233).\u003c\/p\u003e\n\n\u003cp\u003eThe kit contains deoxyribo-oligonucleotides, which makes it unsuitable for use with DNA-binding proteins or enzymes that degrade DNA.\u003c\/p\u003e\n\n\u003cp\u003eNote: Certificate of conformance is available for Biacore™ cap-tag conjugation kit and Biacore™ regeneration kit CAP, but no certificate of analysis is provided.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/0H_eJ-4fQvOtgj0qE6Y-qA-pdf\"\u003eData file (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29752323_zh-cn.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"Biacore 1 series, Biacore 8 series, Biacore T200 and Biacore S200 SPR systems \/ 1 kit","offer_id":45982340120655,"sku":"29873737","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Any Biacore SPR system \/ 1 kit (29805821)","offer_id":45982340153423,"sku":"29805821","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Any Biacore SPR system \/ 1 kit (29805822)","offer_id":45982340186191,"sku":"29805822","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/GqQkDkNaRXa0O2MaT7xHbQ-original-png.png?v=1782742144"},{"product_id":"acetate-immobilization-buffers-br100351","title":"Acetate immobilization buffers","description":"\u003cp\u003eImmobilization buffers containing 10 mM sodium acetate. For most types of interaction analyses in Biacore™ SPR systems. For in vitro use only.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22056747.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"4.0","offer_id":45982342545487,"sku":"BR100349","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"4.5","offer_id":45982342578255,"sku":"BR100350","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"5.0","offer_id":45982342611023,"sku":"BR100351","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"5.5","offer_id":45982342643791,"sku":"BR100352","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-4499-original-png_15533417-9ce1-4435-b5da-9afaf1e703c4.png?v=1785960342"},{"product_id":"plastic-vials-29266981","title":"Plastic vials","description":"\u003cp\u003ePolypropylene (PP) vials in a range of sizes, for use with Biacore SPR systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAvailable in 7 mm O.D. (0.8 mL), 11 mm O.D. (1.5 mL) and 15 mm O.D. (4.0 mL) sizes.\u003c\/li\u003e\n\u003cli\u003e11 mm vials have a wide opening that allows a pipette to reach the bottom.\u003c\/li\u003e\n\u003cli\u003e15 mm vials in pack of 100; 11 mm vials in pack of 500, and 7 mm vials in pack of 1000.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"7 mm","offer_id":45982343856207,"sku":"BR100212","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"11 mm","offer_id":45982343888975,"sku":"BR100287","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"Ø 15 mm","offer_id":45982343921743,"sku":"29266981","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-30765-original-png_ea8fccc2-b682-4b0b-bc6e-f9e0407936f0.png?v=1785960349"},{"product_id":"biacore-x100-spr-system-br110073","title":"Biacore™ X100 SPR system","description":"\u003cp\u003eBiacore™ X100 is a key analysis tool to boost your understanding of protein function and biological mechanisms. The robust small-scale interaction analysis system produces reliable affinity, kinetics, and active concentration data.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKinetic data in less than an hour – Use of a capture kit eliminates assay development time and allows you to get final data faster.\u003c\/li\u003e\n\u003cli\u003eHighly sensitive instrument – allow you to study a variety of molecules including low molecular compounds, DNA, proteins, antibodies and viruses.\u003c\/li\u003e\n\u003cli\u003eDisplay of interactions over a range of temperatures in real-time – better mimic biological processes for deeper insight into molecular mechanism.\u003c\/li\u003e\n\u003cli\u003eStructured approach to assay development – guided workflows for specificity, affinity, kinetics analysis.\u003c\/li\u003e\n\u003cli\u003eReliable data analysis – Easy quality control tools help you to assess data quality and facilitate valid data interpretation.\u003c\/li\u003e\n\u003cli\u003eReliably monitor amount of an active protein – Biacore X100 Plus Package extends functionality and adding features such as concentration analysis without the need for calibration curve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-15563-pdf.%0A\"\u003eData file\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003eBiacore™ X100 workflow oriented software provides a structured approach to assay development, minimizes hands-on time, and generates reliable data without compromising flexibility for the best assay set up.\u003c\/p\u003e\n\n\u003cp\u003eCompare the Biacore™ X100 to Biacore™ 1 series models:\u003c\/p\u003e\n\n\u003cdiv class=\"table-responsive\"\u003e\n\u003ctable class=\"table table-bordered\"\u003e\n\t\u003cthead\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003cth\u003e \u003c\/th\u003e\n\t\t\t\u003cth\u003eBiacore™ X100\u003c\/th\u003e\n\t\t\t\u003cth\u003eBiacore™ 1 series\u003c\/th\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/thead\u003e\n\t\u003ctbody\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eKinetics\/affinity characterization\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eKinetics\/affinity screening\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eBiacore Single Cycle Kinetics (SCK)™\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eLMW interaction analysis\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eFragment screening\u003c\/td\u003e\n\t\t\t\u003ctd\u003e \u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eEpitope binning\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/yOAZOOe6T3mT1cacF9ZFxA-medium?v=0345bfc2\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eImmunogenicity\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/yOAZOOe6T3mT1cacF9ZFxA-medium?v=0345bfc2\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/yOAZOOe6T3mT1cacF9ZFxA-medium?v=0345bfc2\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eConcentration analysis\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eCalibration-free concentration analysis\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eParallel line analysis (PLA)\u003c\/td\u003e\n\t\t\t\u003ctd\u003e \u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eBuffer scouting using ABA command\u003c\/td\u003e\n\t\t\t\u003ctd\u003e \u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eMulti-complex analysis using Poly command ••\u003c\/td\u003e\n\t\t\t\u003ctd\u003e \u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eGxP support\u003c\/td\u003e\n\t\t\t\u003ctd\u003e \u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eBuilt-in knowledge library\u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\t\u003ctd\u003e \u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\t\u003ctr\u003e\n\t\t\t\u003ctd\u003eMethod queue\u003c\/td\u003e\n\t\t\t\u003ctd\u003e \u003c\/td\u003e\n\t\t\t\u003ctd\u003e\u003cimg alt=\"alt text\" class=\"center-block\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:20px;\"\u003e\u003c\/td\u003e\n\t\t\u003c\/tr\u003e\n\t\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\n\u003cp class=\"-font--minus-1\"\u003e\u003cimg alt=\"alt text\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/ef5bXR9VRmiCN2UTKzxBYw-medium?v=782d4889\" style=\"max-width:14px;\"\u003e Application may be performed using the indicated product.\u003cbr\u003e\n\u003cimg alt=\"alt text\" src=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/yOAZOOe6T3mT1cacF9ZFxA-medium?v=0345bfc2\" style=\"max-width:14px;\"\u003e Application may be performed, but with limitations in software and\/or hardware functionality.\u003c\/p\u003e\n\n\u003cp\u003eGet extended functionality with the Biacore™ X100 Plus package\u003c\/p\u003e\n\n\u003cp\u003eThe Biacore™ X100 Plus package adds additional functionality to the system:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli class=\"-font--body\"\u003eStudy interactions involving small molecules in organic solvents\u003c\/li\u003e\n\t\u003cli class=\"-font--body\"\u003eMeasure concentration based on specific binding\u003c\/li\u003e\n\t\u003cli class=\"-font--body\"\u003eAnalyze interactions over a range of temperatures\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThese features are enabled by an integrated in-line degasser that reduces bubble formation in the fluidic path. The Biacore™ X100 Plus package (product code 28956516) is available as an upgrade for existing Biacore X100 instruments or as a complete system package with the degasser pre-installed (product code BR100798)\u003c\/p\u003e\n\n\u003cp\u003eBiacore™ capture kits\u003c\/p\u003e\n\n\u003cp\u003eBiacore™ capture kits provide optimized assay protocols that minimize the need for assay development . Guided workflows and wizards include preprogrammed settings for capture kits and sensor chip surfaces. This further increases the convenience and ease of use, while ensuring efficient use of reagents\u003c\/p\u003e\n\n\u003cp\u003eRead more about the capture kits in the data file, \u003ca href=\"\/shop\/protein-analysis\/spr-label-free-analysis\/spr-consumables\/capture-reagents%0A\"\u003eand\/or visit product page\u003c\/a\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhat’s included\u003c\/p\u003e\n\n\u003cp\u003eThe Biacore™ X100 system package includes the instrument, CDs and product key to install software on two different computer\u003c\/p\u003e\n\n\u003cp\u003eThe Biacore™ X100 Plus system package includes the instrument with in-line degasser installed, CDs and product key for software installation on two different computers.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-15563-pdf\"\u003eData file (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"1 \/ System","offer_id":45982350475343,"sku":"BR110073","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-20502-original-png_49e1e5c9-8940-4f77-9e1c-aa223d94f310.png?v=1785960401"},{"product_id":"rubber-caps-type-4-br100555","title":"Rubber caps (type 4)","description":"\u003cp\u003ePenetrable caps for glass vials 9 mm and plastic vials 7 mm, airtight after penetration.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePenetrable cap made of Kraton™ G (SEBS).\u003c\/li\u003e\n\u003cli\u003eAirtight after penetration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"600 caps","offer_id":45982409916495,"sku":"BR100555","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-30774-original-png_f48c0523-44ef-419d-96fe-48b29e522213.png?v=1785960791"},{"product_id":"rubber-caps-type-3-br100502","title":"Rubber caps (type 3)","description":"\u003cp\u003ePenetrable, ventilated caps for glass vials 9 mm and plastic vials 7 mm, to be used with Biacore SPR systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePenetrable cap made of Kraton™ G (SEBS).\u003c\/li\u003e\n\u003cli\u003eAvailable in packs of 600.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"600 caps","offer_id":45982410014799,"sku":"BR100502","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-30773-original-png_0bd3eb7f-0014-4962-aa7b-97873e534fe0.png?v=1785960793"},{"product_id":"hbs-n-buffer-10-br100828","title":"HBS-N Buffer 10×","description":"\u003cp\u003eRunning buffer. Concentrated stock solution, yielding pH 7.4 when diluted 10X.\u003c\/p\u003e\n\u003cp\u003eFor use in all Biacore SPR systems.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22064820.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"4 x 50 mL","offer_id":45982410244175,"sku":"BR100828","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"1000 mL","offer_id":45982410276943,"sku":"BR100670","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/69c2a45ee6724ce6b5869640310fc044_c0068a0c-cd59-4882-b332-109d471ad662.png?v=1785956229"},{"product_id":"bianormalizing-solution-70-29207950","title":"BIAnormalizing solution (70%)","description":"\u003cp\u003eA glycerol solution to be used when performing normalization of the detector response Biacore 1 series, Biacore 8 series, Biacore S200, Biacore T200, and Biacore 4000 SPR systems.\u003c\/p\u003e","brand":"Cytiva","offers":[{"title":"90 mL","offer_id":45982410211407,"sku":"29207950","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-4656-original-png_60b2f9a8-6864-4b10-8ab6-d9503d934b78.png?v=1785960797"},{"product_id":"hbs-p-buffer-10-br100827","title":"HBS-P+ Buffer 10×","description":"\u003cp\u003eConcentrated stock solution containing 0.1 M HEPES, 1.5 M NaCl and 0.5% v\/v Surfactant P20. Will yield pH 7.4 when diluted 10X.\u003c\/p\u003e\n\u003cp\u003eSupports the recommendations for small molecule assays in Biacore systems. For all systems.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22064820.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"4 x 50 mL","offer_id":45982410604623,"sku":"BR100827","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"1000 mL","offer_id":45982410637391,"sku":"BR100671","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/69c2a45ee6724ce6b5869640310fc044_c0068a0c-cd59-4882-b332-109d471ad662.png?v=1785956229"},{"product_id":"hbs-ep-buffer-10-br100826","title":"HBS-EP+ Buffer 10×","description":"\u003cp\u003eGeneral purpose running buffer. Concentrated stock solution yielding pH 7.4 when diluted 10x.\u003c\/p\u003e\n\u003cp\u003eFor use with all Biacore SPR systems.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22064820.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"4 x 50 mL","offer_id":45982410735695,"sku":"BR100826","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"1000 mL","offer_id":45982410768463,"sku":"BR100669","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/AqqH1LmSRt6vr9LUdg5mig-original-png_5fcec71d-1ea4-47ef-b7e4-9f85344eb26e.png?v=1785960801"},{"product_id":"naoh-50-br100358","title":"NaOH 50","description":"\u003cp\u003eAqueous buffer containing 50 mM NaOH.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22056748.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"100 mL","offer_id":45982410866767,"sku":"BR100358","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-4643-original-png_e6cbd8fa-52d7-41c1-a93d-2d37cbca4dde.png?v=1785960801"},{"product_id":"96-well-septa-29192561","title":"96-well septa","description":"\u003cp\u003eSepta used to cover 96-well microplates in experiments where the injection needles enter each well more than once. For use with Biacore 1 series, Biacore 8 series, Biacore T200 and Biacore S200 SPR systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor use with 96-well or 96-deep-well microplates.\u003c\/li\u003e\n\u003cli\u003eCompatible with polystyrene and polypropylene.\u003c\/li\u003e\n\u003cli\u003eAvailable in packs of 10.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMinimize the risk of carry-over\u003c\/p\u003e\u003cp\u003eEach well is resealed and the needles are wiped off when elevated through the septa, ensuring high-quality data.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29235716.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"10 septa","offer_id":45982410997839,"sku":"29192561","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-3903-original-png_7504968a-591e-429a-816d-bb9e5266fb5b.png?v=1785960804"},{"product_id":"nsb-reducer-for-biacore-br100691","title":"NSB reducer for Biacore™","description":"\u003cp\u003eAdditive to reduce non-specific binding in dextran-based sensor surfaces when running complex sample matrices in Biacore systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReduces nonspecific binding to carboxymethyl dextran sensor surfaces.\u003c\/li\u003e\n\u003cli\u003eSufficient for approximately 650 samples.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22064829.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"10 mL","offer_id":45982411030607,"sku":"BR100691","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/69c2a45ee6724ce6b5869640310fc044_c0068a0c-cd59-4882-b332-109d471ad662.png?v=1785956229"},{"product_id":"biacore-test-solution-29717615","title":"Biacore™ test solution","description":"\u003cp\u003eA standard sucrose solution for checking system performance on Biacore 1 series, Biacore 8 series, Biacore X100, and Biacore C SPR systems. Note: this solution replaces BIAtest solution (HBS-EP).\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29226993.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"65 mL","offer_id":45982412308559,"sku":"29717615","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-4172-original-png_b9e3aa71-5a05-424e-b329-ba5fa48c04fe.png?v=1785960818"},{"product_id":"glycine-solution-br100356","title":"Glycine solution","description":"\u003cp\u003eCytiva’s Aqueous buffer solution contains 10 mM glycine-HCl. It’s used for the removal of bound analyte from Biacore™ SPR sensor surfaces. For in vitro use only.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22056748.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"1.5","offer_id":45982413258831,"sku":"BR100354","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"2.0","offer_id":45982413291599,"sku":"BR100355","price":0.0,"currency_code":"ILS","in_stock":true},{"title":"2.5","offer_id":45982413324367,"sku":"BR100356","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-4592-original-png_b65ef761-2d9c-4624-8249-da5fd8d57e28.png?v=1785960831"},{"product_id":"biacore-microplate-cover-br100420","title":"Biacore Microplate cover","description":"\u003cp\u003eCover for microplates, with aluminum foils to shade light-sensitive samples. For use with Biacore C SPR system.\u003c\/p\u003e","brand":"Cytiva","offers":[{"title":"1 cover","offer_id":45982413914191,"sku":"BR100420","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/69c2a45ee6724ce6b5869640310fc044_c0068a0c-cd59-4882-b332-109d471ad662.png?v=1785956229"},{"product_id":"nta-reagent-kit-28995043","title":"NTA Reagent Kit","description":"\u003cp\u003eReagents for Sensor Chip NTA, used for his capture in his-tagged molecules in biomolecular interaction analysis.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum convenience for his capture in Biacore systems.\u003c\/li\u003e\n\u003cli\u003eProvides ready-to-use solutions for use with sensor chip NTA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUse\u003c\/p\u003e \u003cp\u003eCapture of histidine-tagged molecules using sensor chip NTA requires loading of the surface with nickel ions. After analyte injection the sample cycle is finished by regeneration of the surface, which removes the captured molecule. For these purposes, NTA reagent kit contains ready-to-use nickel solution and regeneration solution.\u003c\/p\u003e \u003cp\u003eKit contents\u003c\/p\u003e \u003cp\u003e \u003c\/p\u003e \u003cul\u003e     \u003cli\u003e0.5 mM NiCl\u003csub\u003e2\u003c\/sub\u003e, 50 mL\u003c\/li\u003e     \u003cli\u003e350 mM EDTA,100 mL\u003c\/li\u003e \u003c\/ul\u003e \u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.cytivalifesciences.com\/api\/public\/content\/digi-16081-pdf\"\u003eData file (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/28997482.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"1 kit","offer_id":45982413979727,"sku":"28995043","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/69c2a45ee6724ce6b5869640310fc044_c0068a0c-cd59-4882-b332-109d471ad662.png?v=1785956229"},{"product_id":"microplates-br100503","title":"Microplates","description":"\u003cp\u003e96-well polystyrene microplates available in packs of 100 plates.\u003c\/p\u003e\n\u003cp\u003eThe polystyrene microplates are designed for use with Biacore™ 8K+, Biacore™ 8K, Biacore™ 4000, Biacore™ S200, Biacore™ T200, Biacore™ T100, Biacore™ 3000, and Biacore™ C SPR systems.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29235716.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"96","offer_id":45982414864463,"sku":"BR100503","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/69c2a45ee6724ce6b5869640310fc044_c0068a0c-cd59-4882-b332-109d471ad662.png?v=1785956229"},{"product_id":"pbs-buffer-10-br100672","title":"PBS Buffer 10×","description":"\u003cp\u003eRunning buffer. Concentrated stock solution, yielding pH 7.4 when diluted 10X and supplemented with 5% DMSO. (PBS buffer with DMSO is commonly used for small molecule assays.)\u003c\/p\u003e\n\u003cp\u003eFor use in all Biacore SPR systems.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22064821.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"1000 mL","offer_id":45982415061071,"sku":"BR100672","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/69c2a45ee6724ce6b5869640310fc044_c0068a0c-cd59-4882-b332-109d471ad662.png?v=1785956229"},{"product_id":"pbs-p-buffer-10-28995084","title":"PBS-P+ Buffer 10×","description":"\u003cp\u003ePhosphate buffered saline containing detergent, which is recommended as running buffer for small molecule analysis in Biacore systems. Concentrated stock solution, yielding pH 7.4 when diluted 10X and supplemented with 2% DMSO. PBS buffer with DMSO is commonly used for small molecule compound samples.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/28997887.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"1000 mL","offer_id":45982415290447,"sku":"28995084","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/69c2a45ee6724ce6b5869640310fc044_c0068a0c-cd59-4882-b332-109d471ad662.png?v=1785956229"},{"product_id":"biamaintenance-kit-29394521","title":"BIAmaintenance Kit","description":"\u003cp\u003eKit for conducting instrument maintenance for Biacore X100, Biacore C, and Biacore 3000 SPR systems. Includes Biacore test solution, BIAdesorb, BIAnormalizing solutions, and Sensor Chip Maintenance.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSufficient for 6 months normal usage\u003c\/li\u003e\n\u003cli\u003eHBS-EP+ buffer (BR100826 or BR100669B) should be ordered separately\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e  \u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29396778.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"1","offer_id":45982415847503,"sku":"29394521","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/69c2a45ee6724ce6b5869640310fc044_c0068a0c-cd59-4882-b332-109d471ad662.png?v=1785956229"},{"product_id":"caps-7-mm-br100213","title":"Caps, 7 mm","description":"\u003cp\u003eThin polyethylene snap caps\u003c\/p\u003e","brand":"Cytiva","offers":[{"title":"1000 caps","offer_id":45982416633935,"sku":"BR100213","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-30754-original-png_6a482aa6-ea39-4614-bef4-ec8aac950266.png?v=1785960872"},{"product_id":"surfactant-p20-for-biacore-br100054","title":"Surfactant P20 for Biacore™","description":"\u003cp\u003eBuffer additive recommended for inclusion in Biacore systems. Reduces adsorption of hydrophilic molecules to flow system surfaces.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eSupplied as a filtered 10% solution in water.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22051063.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"20 mL","offer_id":45982416568399,"sku":"BR100054","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-30777-original-png_eaed52a9-2400-40f2-a6fd-b050976d55a0.png?v=1785960872"},{"product_id":"desorb-kit-br100823","title":"Desorb kit","description":"\u003cp\u003eKit containing BIAdesorb solutions for cleaning the flow system of any Biacore system.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eCapacity sufficient for at least 2 months of normal use in Biacore 8 series systems and at least 6 months normal use in single-needle Biacore systems.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22064879.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"Default Title","offer_id":45982417059919,"sku":"BR100823","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/69c2a45ee6724ce6b5869640310fc044_c0068a0c-cd59-4882-b332-109d471ad662.png?v=1785956229"},{"product_id":"rubber-caps-type-2-br100411","title":"Rubber caps (type 2)","description":"\u003cp\u003ePenetrable, ventilated caps for glass vials 16 mm and plastic vials 11 mm, to be used with Biacore SPR systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePenetrable cap made of Kraton™ G (SEBS).\u003c\/li\u003e\n\u003cli\u003eAvailable in packs of 400.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"400 caps","offer_id":45982417158223,"sku":"BR100411","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-30772-original-png_b4d05a33-41c3-40d8-a4a2-83063fa89d91.png?v=1785960880"},{"product_id":"series-s-sensor-chip-cap-29805820","title":"Series S Sensor Chip CAP","description":"\u003cp\u003eSeries S Sensor Chip CAP enables reversible capture for biotinylated proteins when used alongside Biotin CAPture reagent or for multiple protein types when used in combination with Biacore™ cap-tag conjugation kit.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSimple protein capture regardless of tag when combined with Biacore™ cap-tag conjugation kit.\u003c\/li\u003e\n\u003cli\u003eSavings in time and effort, there is no need to develop attachment conditions. Just combine with Biotin CAPture reagent or Biacore™ cap-tag conjugation kit.\u003c\/li\u003e\n\u003cli\u003eA reusable and cost-effective solution. Regenerate at least 150 times using Biacore™ regeneration kit CAP.\u003c\/li\u003e\n\u003cli\u003eThe ideal choice when working with biotinylated or untagged ligands.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSeries S Sensor Chip CAP is a component of both Biotin CAPture Kit Series S and Biacore™ cap-tag capture kit. The sensor chip is available for standalone purchase for more flexibility in your workflows. The sensor chip consists of a carboxylmethyldextran surface preimmobilized with a short oligo-nucleotide which binds either Biotin CAPture reagent or Biacore™ cap-tag. The sensor chip can be regenerated using Biacore™ regeneration kit CAP at least 150 cycles.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29752324.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"Biacore 1 series, Biacore 8 series, Biacore T200 and Biacore S200 SPR systems \/ 1 sensor chip \/ Series S","offer_id":45982417944655,"sku":"29805820","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/9qpg7Zu0TZG7YfJMdWSBBQ-original-png_4d542032-7a06-4fce-9b78-c242913ee553.png?v=1785960892"},{"product_id":"pdea-thiol-coupling-reagent-br100058","title":"PDEA Thiol Coupling Reagent","description":"\u003cp\u003eReagent for performing ligand and\/or surface thiol couplings.\u003c\/p\u003e\n\u003cp\u003eReactive disulfide groups are introduced onto carboxyl groups of either the sensor chip matrix or the ligand. Sufficient for 18 ligand thiol immobilizations or 22 surface thiol immobilizations.\u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22051359.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"1 × 100 mg","offer_id":45982418403407,"sku":"BR100058","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/69c2a45ee6724ce6b5869640310fc044_c0068a0c-cd59-4882-b332-109d471ad662.png?v=1785956229"},{"product_id":"plastic-vials-and-caps-br100214","title":"Plastic vials and caps","description":"\u003cp\u003ePlastic polypropylene vials for storage, with screw-top caps and O-ring seals, 11 mm O.D. (2.0 mL) for use with Biacore systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2.0 ml polypropylene screw top vials, screw caps with O-ring seal.\u003c\/li\u003e\n\u003cli\u003eThe screw caps are only to be used for storage, not to be used in the instrument.\u003c\/li\u003e\n\u003cli\u003ePack of 500 each vials and screw caps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor use with Biacore systems.\u003c\/p\u003e","brand":"Cytiva","offers":[{"title":"500 vials and caps","offer_id":45982418665551,"sku":"BR100214","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-30768-original-png_eb45074c-9e76-4038-a424-7956cc8bfa06.png?v=1785960901"},{"product_id":"rubber-caps-type-5-br100655","title":"Rubber caps (type 5)","description":"\u003cp\u003ePenetrable, ventilated caps for plastic vials 15 mm, to be used with Biacore SPR systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePenetrable cap made of Kraton™ G (SEBS).\u003c\/li\u003e\n\u003cli\u003eAvailable in packs of 400.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"400 caps","offer_id":45982418698319,"sku":"BR100655","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-30775-original-png_7bea286f-b1df-45a8-b1db-69ded63c952d.png?v=1785960902"},{"product_id":"rubber-caps-br100286","title":"Rubber caps","description":"\u003cp\u003ePenetrable caps for glass and plastic vials 16 mm and 11 mm, to be used with Biacore systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePenetrable cap made of Kraton™ G (SEBS).\u003c\/li\u003e\n\u003cli\u003eAirtight after penetration.\u003c\/li\u003e\n\u003cli\u003eAvailable in packs of 400.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"400 caps","offer_id":45982419320911,"sku":"BR100286","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-30776-original-png_cc24bf9f-0e7f-4795-822d-47aa7bc23095.png?v=1785960918"},{"product_id":"biacore-maintenance-kit-type-2-29394519","title":"Biacore maintenance kit (type 2)","description":"\u003cul\u003e\n\u003cli\u003eSufficient for six months of normal use.\u003c\/li\u003e\n\u003cli\u003eAdditional HBS-N buffer should be ordered separately (product code (BR-1006-70).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/29396777.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"1","offer_id":45982419517519,"sku":"29394519","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/69c2a45ee6724ce6b5869640310fc044_c0068a0c-cd59-4882-b332-109d471ad662.png?v=1785956229"},{"product_id":"microplate-and-foil-96-well-br100383","title":"Microplate and foil 96-well","description":"\u003cp\u003ePacks of polystyrene (PS) microplates with 96 wells, supplied with aluminum foils for coverage. For Biacore C.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003ePack contains 50 polystyrene microplates and aluminum foils.\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"50 plates and foils","offer_id":45982419615823,"sku":"BR100383","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/digi-30753-original-png_9da89bd8-a9c4-4809-8f04-60354b298e99.png?v=1785960921"},{"product_id":"amine-coupling-kit-br100050","title":"Amine coupling kit","description":"\u003cp\u003eReagents for covalent immobilization of molecules carrying a primary amine group.\u003c\/p\u003e\n\u003cp\u003eThe kit contains reagents sufficient for approximately 80 immobilizations. Reagents in the kit are:\u003c\/p\u003e\n\n\u003cul\u003e\n\t\u003cli\u003eN-Hydroxysuccinimide (NHS), 115 mg\u003c\/li\u003e\n\t\u003cli\u003e1-Ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC), 750 mg\u003c\/li\u003e\n\t\u003cli\u003e1 M Ethanolamine hydrochloride-NaOH pH 8.5, 10.5 mL\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eFor use with all Biacore™ SPR systems, excluding Biacore™ 4000. \u003c\/p\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22051062.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"1 kit","offer_id":45982420598863,"sku":"BR100050","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/IAR1_MmoR56HO63BLk3tDA-original-png_24b63999-74f0-40ea-9016-cd8b17c90e04.png?v=1785960931"},{"product_id":"mouse-antibody-capture-kit-br100838","title":"Mouse antibody capture kit","description":"\u003cp\u003eReagents for the capture of mouse antibodies as ligands in various biomolecular interaction analyses.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBinds all IgG subclasses (IgG1, IgG2a, IgG2b, and IgG3), IgA, and IgM.\u003c\/li\u003e\n\u003cli\u003eVery stable binding with no or very low dissociation of captured antibodies.\u003c\/li\u003e\n\u003cli\u003eSufficient for 10 immobilizations and 1000 regenerations.\u003c\/li\u003e\n\u003cli\u003eFor component volumes larger than the standard mouse antibody capture kit, see the Mouse antibody capture kit Type 2 version.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIntended use\u003c\/p\u003e\u003cp\u003eMouse antibody capture kit is intended for capture of mouse antibodies as ligands in various biomolecular interaction analyses. Anti-mouse IgG is suitable for immobilization on carboxyl derivatized surfaces using amine coupling kit and the included immobilization buffer, while the regeneration solution is used for regeneration of the surface.\u003c\/p\u003e\u003cp\u003eAnti-mouse antibody description\u003c\/p\u003e\u003cp\u003eAnti-mouse IgG consists of polyclonal rabbit anti-mouse immunoglobulin antibodies reacting with all IgG subclasses (IgG1, IgG2a, IgG2b and IgG3), IgA and IgM. Reaction with other mouse immunoglobulin classes is not investigated, but the antibodies are likely to react with these via their light chains.\u003c\/p\u003e\u003cp\u003eCross-reactivity\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eHuman immunoglobulins \u0026lt; 0.5%\u003c\/li\u003e\n\u003cli\u003eFetal calf serum \u0026lt; 0.1%\u003c\/li\u003e\n\u003cli\u003eGoat and ox immunoglobulins \u0026lt; 1%\u003c\/li\u003e\n\u003cli\u003eGuinea pig and swine immunoglobulins, approx. 5%\u003c\/li\u003e\n\u003cli\u003eRat immunoglobulins, approx. 25%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eDocuments\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/d3.cytivalifesciences.com\/prod\/IFU\/22064897.pdf\"\u003eInstructions for use (PDF)\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Cytiva","offers":[{"title":"1 kit","offer_id":45982421057615,"sku":"BR100838","price":0.0,"currency_code":"ILS","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/files\/69c2a45ee6724ce6b5869640310fc044_c0068a0c-cd59-4882-b332-109d471ad662.png?v=1785956229"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0712\/0748\/5519\/collections\/DAWN-Hero-Neon-9-19_750f996d-46f1-4899-8c15-6957f150ad34.jpg?v=1790860266","url":"https:\/\/www.danyel.co.il\/collections\/analytical-instruments.oembed","provider":"danyel biotech","version":"1.0","type":"link"}